{"id":253416,"date":"2024-10-19T16:44:22","date_gmt":"2024-10-19T16:44:22","guid":{"rendered":"https:\/\/pdfstandards.shop\/product\/uncategorized\/bs-en-500692018-tc\/"},"modified":"2024-10-25T12:05:37","modified_gmt":"2024-10-25T12:05:37","slug":"bs-en-500692018-tc","status":"publish","type":"product","link":"https:\/\/pdfstandards.shop\/product\/publishers\/bsi\/bs-en-500692018-tc\/","title":{"rendered":"BS EN 50069:2018 – TC"},"content":{"rendered":"
This document applies to welded composite enclosures of cast and wrought aluminium alloy pressurized with dry air, inert gases (e.g. sulphur hexafluoride or nitrogen or a mixture of such gases), used in indoor and outdoor installations of high-voltage switchgear and controlgear with rated voltages above 1 kV, where the gas is used principally for its dielectric and\/or arc-quenching properties with rated voltages: – above 1 kV and up to and including 52 kV concerning gas-filled compartments with design pressure higher than 300 kPa relative pressure (gauge); – above 52 kV concerning all gas-filled compartments. The enclosures comprise parts of electrical equipment not necessarily limited to the following examples: – circuit-breakers; – switch-disconnectors; – disconnectors; – earthing switches; – current transformers; – voltage transformers; – surge arrestors; – busbars and connections; – etc. The scope also covers enclosures of pressurized components such as the centre chamber of live tank switchgear, gas-insulated current transformers, etc.<\/p>\n
PDF Pages<\/th>\n | PDF Title<\/th>\n<\/tr>\n | ||||||
---|---|---|---|---|---|---|---|
32<\/td>\n | undefined <\/td>\n<\/tr>\n | ||||||
34<\/td>\n | Blank Page <\/td>\n<\/tr>\n | ||||||
38<\/td>\n | 1 Scope 2 Normative references <\/td>\n<\/tr>\n | ||||||
39<\/td>\n | 3 Terms and definitions <\/td>\n<\/tr>\n | ||||||
42<\/td>\n | 4 Quality assurance 5 Normal and special service conditions 6 Materials 6.1 Selection of material <\/td>\n<\/tr>\n | ||||||
44<\/td>\n | 6.2 Chemical analysis <\/td>\n<\/tr>\n | ||||||
45<\/td>\n | 7 Design 7.1 General 7.2 Calculation methods 7.3 Inspection and access openings 8 Manufacture and workmanship 9 Repair of welding defects 10 Inspection, testing and certification 10.1 Type tests 10.2 Inspection and routine tests <\/td>\n<\/tr>\n | ||||||
46<\/td>\n | 10.3 Welding procedure specifications 10.4 Welder performance tests 10.5 Non-destructive testing 10.6 Design specification, drawings and data sheets 10.7 Certificate 10.8 Stamping 10.9 Final inspection 11 Pressure relief devices <\/td>\n<\/tr>\n | ||||||
47<\/td>\n | Annex A (informative)A-deviation <\/td>\n<\/tr>\n<\/table>\n","protected":false},"excerpt":{"rendered":" Tracked Changes. High-voltage switchgear and controlgear. Gas-filled welded composite enclosures of cast and wrought aluminium alloys<\/b><\/p>\n |