AAMI 11140 4 2007 RA 2015
$115.49
ANSI/AAMI/ISO 11140-4:2007/(R)2015 – Sterilization of health care products – Chemical indicators – Part 4: Class 2 indicators as an alternative to Bowie and Dick test for detection of steam penetration
Published By | Publication Date | Number of Pages |
AAMI | 2007 | 48 |
Specifies performance for a Class 2 indicator to be used as an alternative to the Bowie and Dick test for steam sterilizers for wrapped health care goods (instruments, etc. and porous loads)
PDF Catalog
PDF Pages | PDF Title |
---|---|
1 | ANSI/AAMI/ISO 11140-4:2007/(R)2015, Sterilization of health care products – Chemical indicators – Part 4: Class 2 indicators as an alternative to Bowie and Dick test for detection of steam penetration |
2 | Objectives and uses of AAMI standards and recommended practices |
3 | Title page |
4 | AAMI Standard Copyright information |
5 | Contents |
6 | Glossary of equivalent standards |
8 | Committee representation |
10 | Background of AAMI adoption of ISO 11140-4:2007 |
11 | Foreword |
12 | Introduction |
13 | 1 Scope 2 Normative references |
14 | 3 Terms and definitions |
15 | 4 General requirements |
16 | 5 Indicator system format 6 Performance requirements |
18 | 7 Packaging and labeling |
20 | 8 Quality assurance |
21 | Annex A Determination of indicator strength during and after steam sterilization A.1 Apparatus A.2 Procedure |
23 | Annex B Standard test cycles |
24 | B.2 Cycle 2: Air removal by trans-atmospheric pulsing |
25 | B.3 Cycle 3: Air removal by super-atmospheric pulsing |
26 | B.4 Acceptance limits during steam admission |
28 | Annex C Estimation of visual difference between color of the substrate and of the changed or unchanged indicator system by determination of relative reflectance density C.1 Principle C.2 Apparatus |
29 | C.3 Test method C.3.1 Sample conditioning C.3.2 Procedure |
30 | C.4 Test report |
32 | Annex D Determination of uniform color change on exposure to saturated steam D.1 Apparatus D.2 Procedure |
33 | Annex E Determination of equivalence of the alternative indicator to the Bowie and Dick test E.1 Principle E.2 Apparatus E.3 Procedure |
35 | Annex F Determination of reproducibility of fail conditions created in a standard test pack by air injection, air leak and retained air systems F.1 General F.2 Criteria for acceptability of test cycles F.2.1 General F.2.2 Reference fault condition |
36 | F.2.3 No fault condition |
37 | F.3 Statistical evaluation of reproducibility |
39 | Annex G Determination of indicator color change on exposure to dry heat G.1 Apparatus G.2 Procedure G.2.1 General |
40 | Annex H Determination of shelf life of product |
41 | Annex I Accelerated aging of test samples |
42 | Annex J Steam exposure apparatus and steam for test purposes J.1 General J.2 Instrumentation J.2.1 General J.2.2 Indicator, controller, and recorder sensors J.2.3 Calibration |
43 | J.3 Cycle control J.3.1 Steam control J.3.2 Air detector J.3.3 Signals J.4 Operating cycle stages and control limits required J.4.1 Cycle stages J.4.2 Control limits |
44 | J.5 Steam supply |
45 | Annex K Standard test pack |
46 | Annex L Air injection system |
48 | Bibliography |