ASHRAE Guideline 2-2005 Engineering Analysis of Experimental Data
Published By | Publication Date | Number of Pages |
ASHRAE | 2005 | 30 |
PDF Catalog
PDF Pages | PDF Title |
---|---|
4 | ForEwOrd ForEwOrd |
10 | Figure 7-1 Stationary data set including an outlier at a part- load ratio of 40%. Figure 7-1 Stationary data set including an outlier at a part- load ratio of 40%. Figure 7-2 Time-dependent data set with single outlier near hour 15 (3:00 p.m.). Figure 7-2 Time-dependent data set with single outlier near hour 15 (3:00 p.m.). |
11 | TABLE 7-1 Chauvenet’s Criterion for Rejecting Outliers TABLE 7-1 Chauvenet’s Criterion for Rejecting Outliers |
13 | Figure 8-1 Example of heat transfer data. Figure 8-1 Example of heat transfer data. Figure 8-2 Example of heat transfer data including first- order curve fit for all data in the flow rate range from 10 to 50 gpm [0.63 – 3.2 l/s]. Figure 8-2 Example of heat transfer data including first- order curve fit for all data in the flow rate range from 10 to 50 gpm [0.63 – 3.2 l/s]. |
14 | Figure 8-3 Example of heat transfer data including second- order curve fit for all data in the flow rate range from 10 to 100 gpm [0.63 to 6.3 l/s]. Figure 8-3 Example of heat transfer data including second- order curve fit for all data in the flow rate range from 10 to 100 gpm [0.63 to 6.3 l/s]. |
15 | Figure 8-5 Overall or histogram plot of the residuals that resulted from the quadratic curve fit shown in Figure 8-3. Figure 8-5 Overall or histogram plot of the residuals that resulted from the quadratic curve fit shown in Figure 8-3. Figure 8-6 Residuals plotted in order of observation. Figure 8-6 Residuals plotted in order of observation. |
16 | Figure 8-7a Residuals exhibitng acceptable behavior. Figure 8-7a Residuals exhibitng acceptable behavior. |
17 | ANNEX A UNCERTAINTY ANALYSIS/PROPAGATION OF ERROR ANNEX A UNCERTAINTY ANALYSIS/PROPAGATION OF ERROR |
22 | Annex B HVAC&R SYSTEM Examples Annex B HVAC&R SYSTEM Examples |
24 | Figure B-1 Preliminary uncertainty analysis of chiller COP. Figure B-1 Preliminary uncertainty analysis of chiller COP. Figure B-2 Illustration of a mixing valve. Figure B-2 Illustration of a mixing valve. |
25 | Figure B-3 Illustration of a simple heat exchanger. Figure B-3 Illustration of a simple heat exchanger. Figure B-4 “Measured” hot-side and cold-side heat exchanger loads including respective uncertainties as a range. Figure B-4 “Measured” hot-side and cold-side heat exchanger loads including respective uncertainties as a range. TABLE B-1 Parameters and Uncertainties Used in the Example Heat Exchanger TABLE B-1 Parameters and Uncertainties Used in the Example Heat Exchanger |
26 | Annex C Reporting of Results Annex C Reporting of Results |
27 | TABLE C-1 Precision and Bias for Tests on a 10.16-cm-Thick Layer of Expanded Polystyrene Foam TABLE C-1 Precision and Bias for Tests on a 10.16-cm-Thick Layer of Expanded Polystyrene Foam Figure C-1 Thermal resistance vs. mean temperature for a 10.16-cm-thick layer of expanded polystyrene foam. Figure C-1 Thermal resistance vs. mean temperature for a 10.16-cm-thick layer of expanded polystyrene foam. |
28 | annex d bibliography annex d bibliography |