Shopping Cart

No products in the cart.

ASME AG 1 2015

$98.04

ASME AG-1 – 2015: Code on Nuclear Air and Gas Treatment

Published By Publication Date Number of Pages
ASME 2015
Guaranteed Safe Checkout
Category:

If you have any questions, feel free to reach out to our online customer service team by clicking on the bottom right corner. We’re here to assist you 24/7.
Email:[email protected]

Provides requirements for the performance, design, construction, acceptance testing, and quality assurance of equipment used as components in nuclear safety-related air and gas treatment systems in nuclear facilities.

PDF Catalog

PDF Pages PDF Title
4 CONTENTS
13 FOREWORD
14 COMMITTEE ROSTER
17 ORGANIZATION OF ASME AG-1
19 SUMMARY OF CHANGES
22 Division I General Requirements
23 SECTION AA COMMON ARTICLES
ARTICLE AA-1000 INTRODUCTION
28 ARTICLE AA-2000 REFERENCED DOCUMENTS
30 ARTICLE AA-3000 MATERIALS
31 Tables
TABLE AA-3100 ALLOWABLE MATERIALS
36 ARTICLE AA-4000 STRUCTURAL DESIGN
37 TABLE AA-4212 LOAD CONDITIONS
38 TABLE AA-4231 DEFLECTION LIMITS
40 TABLE AA-4321 PLATE- AND SHELL-TYPE COMPONENTS: PRIMARY STRESS ALLOWABLES
41 TABLE AA-4323 LINEAR-TYPE SYSTEMS: PRIMARY STRESS ALLOWABLES
44 Figures
FIG. AA-4355.3 SINE BEAT FREQUENCY AND AMPLITUDE
45 FIG. AA-4355.4 SINE AMPLITUDE DECAY RATE
46 FIG. AA-4356.4-1 RESPONSE SPECTRUM OF COMPOSITE EXCITATION
47 FIG. AA-4356.4-2 OSCILLATIONS PER BEAT
50 ARTICLE AA-5000 INSPECTION AND TESTING
52 ARTICLE AA-6000 FABRICATION, JOINING, WELDING, BRAZING,PROTECTIVE COATING, AND INSTALLATION
56 FIG. AA-6324.2 ACCEPTABLE AND UNACCEPTABLE WELD PROFILES
64 ARTICLE AA-7000 PACKAGING, SHIPPING, RECEIVING, STORAGE,AND HANDLING
66 ARTICLE AA-8000 QUALITY ASSURANCE
67 FIG. AA-8130 HIERARCHY OF RESPONSIBILITY
68 ARTICLE AA-9000 NAMEPLATES AND STAMPING
69 ARTICLE AA-10000 REPAIR AND REPLACEMENT OF COMPONENTS
71 TABLE AA-10530 LIFETIME REPAIR AND REPLACEMENT RECORDS
TABLE AA-10540 NONPERMANENT REPAIR AND REPLACEMENT RECORDS
72 NONMANDATORY APPENDIX AA-A DESIGN AND QUALIFICATION BY ANALYSIS
89 NONMANDATORY APPENDIX AA-B SEISMIC QUALIFICATION BY TESTING
94 NONMANDATORY APPENDIX AA-C QUALIFICATION BY A COMBINATION OFANALYSIS AND TESTING
98 Division II Ventilation Air Cleaning and Ventilation Air Conditioning
99 SECTION BA FANS AND BLOWERS
ARTICLE BA-1000 INTRODUCTION
101 ARTICLE BA-2000 REFERENCED DOCUMENTS
102 ARTICLE BA-3000 MATERIALS
103 ARTICLE BA-4000 DESIGN
105 TABLE
TABLE BA-4162MAXIMUM ALLOWABLE DISPLACEMENT
109 ARTICLE BA-5000 INSPECTION AND TESTING
111 ARTICLE BA-6000 FABRICATION AND INSTALLATION OFCENTRIFUGAL AND AXIAL FANS
112 ARTICLE BA-7000 PACKAGING, SHIPPING, RECEIVING, STORAGE,AND HANDLING
113 ARTICLE BA-8000 QUALITY ASSURANCE
114 ARTICLE BA-9000 NAMEPLATES AND OPERATING ANDMAINTENANCE MANUALS
115 NONMANDATORY APPENDIX BA-A FAN SYSTEM CONSIDERATIONS
117 NONMANDATORY APPENDIX BA-B DIVISION OF RESPONSIBILITY
119 SECTION DA DAMPERS AND LOUVERS
ARTICLE DA-1000 INTRODUCTION
122 ARTICLE DA-2000 REFERENCED DOCUMENTS
123 ARTICLE DA-3000 MATERIALS
125 ARTICLE DA-4000 DESIGN
132 ARTICLE DA-5000 INSPECTION AND TESTING
134 ARTICLE DA-6000 FABRICATION, FINISHING, AND INSTALLATION
135 ARTICLE DA-7000 PACKAGING, SHIPPING, AND STORAGE
136 ARTICLE DA-8000 QUALITY ASSURANCE
137 ARTICLE DA-9000 NAMEPLATES, STAMPINGS, AND MANUALS
138 MANDATORY APPENDIX DA-I SEAT AND FRAME LEAKAGE
139 MANDATORY APPENDIX DA-II DAMPER AND LOUVER CONFIGURATIONS
145 NONMANDATORY APPENDIX DA-A DIVISION OF RESPONSIBILITY
147 SECTION SA DUCTWORK
ARTICLE SA-1000 INTRODUCTION
149 Figure
FIG. SA-1120 DUCTWORK AND DUCTWORK SUPPORT Ð INTERFACE BOUNDARY
150 ARTICLE SA-2000 REFERENCED DOCUMENTS
151 ARTICLE SA-3000 MATERIALS
152 ARTICLE SA-4000 DESIGN
158 ARTICLE SA-5000 INSPECTION AND TESTING
161 ARTICLE SA-6000 FABRICATION AND INSTALLATION
163 Tables
TABLE SA-6410-1 RECTANGULAR DUCTS: MAXIMUM ALLOWABLE TOLERANCES
164 TABLE SA-6410-2 CIRCULAR DUCTS: MAXIMUM ALLOWABLE TOLERANCES
165 TABLE SA-6410-3 FLATNESS OF SURFACE: MAXIMUM ALLOWABLE WAVINESS TOLERANCE
166 ARTICLE SA-7000 PACKAGING, SHIPPING, RECEIVING, STORAGE,AND HANDLING
168 ARTICLE SA-8000 QUALITY ASSURANCE
169 ARTICLE SA-9000 NAMEPLATES AND STAMPING
170 NONMANDATORY APPENDIX SA-A DIVISION OF RESPONSIBILITY
172 NONMANDATORY APPENDIX SA-B PROCEDURES TO DETERMINE ALLOWABLE LEAKAGE FOR DUCTWORK
188 NONMANDATORY APPENDIX SA-C ADDITIONAL GUIDELINES FOR DUCT DESIGN AND CONSTRUCTION
190 SECTION HA HOUSINGS
ARTICLE HA-1000 INTRODUCTION
191 Figures
FIG. HA-1120-1 HOUSING, AIR CLEANING UNIT: WALK-IN TYPE
FIG. HA-1120-2 HOUSING, AIR CLEANING UNIT: SIDE-ACCESS TYPE
192 FIG. HA-1120-3 HOUSING, AIR CONDITIONING UNIT: WALK-IN TYPE
193 ARTICLE HA-2000 REFERENCED DOCUMENTS
194 ARTICLE HA-3000 MATERIALS
196 ARTICLE HA-4000 DESIGN
197 Table
TABLE HA-4212 LOAD COMBINATIONS
203 ARTICLE HA-5000 INSPECTION AND TESTING
206 ARTICLE HA-6000 FABRICATION
208 ARTICLE HA-7000 PACKAGING, SHIPPING, RECEIVING, STORAGE,AND HANDLING
209 ARTICLE HA-8000 QUALITY ASSURANCE
210 ARTICLE HA-9000 NAMEPLATES AND STAMPING
211 NONMANDATORY APPENDIX HA-A DIVISION OF RESPONSIBILITY
212 NONMANDATORY APPENDIX HA-B ADDITIONAL GUIDELINES FOR HOUSING DESIGN AND CONSTRUCTION
214 NONMANDATORY APPENDIX HA-C MANIFOLD DESIGN GUIDELINES
223 NONMANDATORY APPENDIX HA-D PERFORMANCE TEST FOR QUALIFICATION OFSAMPLING MANIFOLDS
226 SECTION RA REFRIGERATION EQUIPMENT
ARTICLE RA-1000 INTRODUCTION
227 ARTICLE RA-2000 REFERENCED DOCUMENTS
228 ARTICLE RA-3000 MATERIALS
230 ARTICLE RA-4000 DESIGN REQUIREMENTS
234 ARTICLE RA-5000 INSPECTION, RATING, AND TESTING
237 ARTICLE RA-6000 FABRICATION AND INSTALLATION
239 ARTICLE RA-7000 PACKAGING, SHIPPING, STORAGE, AND HANDLING
241 ARTICLE RA-8000 QUALITY ASSURANCE
242 ARTICLE RA-9000 NAMEPLATES, STAMPING, AND RECORDS
243 Forms
FORM RA-1 MANUFACTURER’S DATA REPORT FOR SECTION RA NON-ASME NUCLEAR VESSELS1 (CUSTOMARY)
245 FORM RA-M1 MANUFACTURER’S DATA REPORT FOR SECTION RA NON-ASME NUCLEAR VESSELS1 (SI)
247 FORM RA-2 CENTRIFUGAL COMPRESSOR TEST RECORD
248 FORM RA-2a CENTRIFUGAL COMPRESSOR OIL PUMP PRESSURE TEST
249 FORM RA-2b CENTRIFUGAL COMPRESSOR PRESSURE TEST RECORD
250 FORM RA-3 RECIPROCATING SCROLL/SCREW COMPRESSOR TESTRECORD
251 FORM RA-3a RECIPROCATING SCROLL/SCREW COMPRESSOR PRESSURETEST RECORD
252 FORM RA-4 ELECTRICAL TEST RECORD Ð CONTROLS AND CONTROL PANELS
253 FORM RA-5 PERFORMANCE TEST RECORD (CUSTOMARY)
255 FORM RA-M5 PERFORMANCE TEST RECORD (SI)
257 MANDATORY APPENDIX RA-I PERFORMANCE TESTING OF CHILLED WATER REFRIGERATION UNIT (CUSTOMARY)
261 MANDATORY APPENDIX RA-MI PERFORMANCE TESTING OF CHILLED WATER REFRIGERATION UNIT (SI)
265 MANDATORY APPENDIX RA-II MANDATORY LIST OF INSTRUMENTATION FUNCTIONS AND CONTROL FUNCTIONS
266 NONMANDATORY APPENDIX RA-A DIVISION OF RESPONSIBILITY
269 NONMANDATORY APPENDIX RA-B TYPICAL EXTERNAL INTERFACE DIAGRAMS
270 SECTION CA CONDITIONING EQUIPMENT
ARTICLE CA-1000 INTRODUCTION
272 ARTICLE CA-2000 REFERENCED DOCUMENTS
273 ARTICLE CA-3000 MATERIALS
275 ARTICLE CA-4000 DESIGN
276 Tables
TABLE CA-4122 MAXIMUM WATER VELOCITIES IN WATER COILS
285 ARTICLE CA-5000 INSPECTION AND TESTING
288 ARTICLE CA-6000 FABRICATION AND INSTALLATION
290 ARTICLE CA-7000 PACKAGING, SHIPPING, STORAGE, AND HANDLING
291 ARTICLE CA-8000 QUALITY ASSURANCE
292 TABLE CA-8120-1 LIFETIME QUALITY ASSURANCE RECORDS
TABLE CA-8120-2 NONPERMANENT QUALITY ASSURANCE RECORDS
293 ARTICLE CA-9000 NAMEPLATES AND RECORDS
295 MANDATORY APPENDIX CA-I MANUFACTURER’S DATA REPORTS
299 MANDATORY APPENDIX CA-II FACTORY TESTING OF EVAPORATIVE COOLERS AND AIR WASHERS
305 NONMANDATORY APPENDIX CA-A DIVISION OF RESPONSIBILITY
307 NONMANDATORY APPENDIX CA-B DESIGN RECOMMENDATIONS
310 SECTION FA MOISTURE SEPARATORS
ARTICLE FA-1000 INTRODUCTION
311 ARTICLE FA-2000 REFERENCED DOCUMENTS
312 ARTICLE FA-3000 MATERIALS
313 ARTICLE FA-4000 DESIGN
314 Figure
FIG. FA-4100-1 TYPICAL MOISTURE SEPARATION CONFIGURATION
315 Table
TABLE FA-4200-1 MOISTURE SEPARATOR PERFORMANCE SPECIFICATIONS
316 ARTICLE FA-5000 INSPECTION AND TESTING
318 ARTICLE FA-6000 FABRICATION
319 ARTICLE FA-7000 PACKAGING, SHIPPING, AND STORAGE
320 ARTICLE FA-8000 QUALITY ASSURANCE
321 ARTICLE FA-9000 NAMEPLATES
322 NONMANDATORY APPENDIX FA-A DIVISION OF RESPONSIBILITY
323 SECTION FB MEDIUM EFFICIENCY FILTERS
ARTICLE FB-1000 INTRODUCTION
324 ARTICLE FB-2000 REFERENCED DOCUMENTS
325 ARTICLE FB-3000 MATERIALS
326 ARTICLE FB-4000 DESIGN
327 ARTICLE FB-5000 INSPECTION AND TESTING
328 ARTICLE FB-6000 FABRICATION
329 ARTICLE FB-7000 PACKAGING, SHIPPING, RECEIVING, STORAGE, AND HANDLING
330 ARTICLE FB-8000 QUALITY ASSURANCE
331 ARTICLE FB-9000 LABELS AND MARKING
332 NONMANDATORY APPENDIX FB-A DIVISION OF RESPONSIBILITY
333 SECTION FC HEPA FILTERS
ARTICLE FC-1000 INTRODUCTION
334 ARTICLE FC-2000 REFERENCED DOCUMENTS
335 ARTICLE FC-3000 MATERIALS
337 ARTICLE FC-4000 DESIGN
Tables
TABLE FC-4110 NOMINAL SIZES AND RATINGS
338 Figures
FIG. FC-4110-1 TYPE A, C, or D METAL-CASED, GASKET-SEALED FILTER
FIG. FC-4110-2 TYPE A WOOD CASE SEPARATOR FILTER
339 FIG. FC-4110-3 TYPE B MINIPLEAT FILTER
FIG. FC-4110-4 TYPE C SEPARATORLESS FILTER
340 FIG. FC-4110-5 TYPE D THREAD SEPARATOR FILTER
341 FIG. FC-4142-1 GEL SEAL FILTER CORNER – ISOMETRIC
343 ARTICLE FC-5000 INSPECTION AND TESTING
344 TABLE FC-5100-1 TEST GROUPS AND SEQUENCE
TABLE FC-5120-1 ACCEPTABLE TEST
345 TABLE FC-5140-1 TEST CONDITIONS AND REQUIREMENTS
346 ARTICLE FC-6000 FABRICATION
347 ARTICLE FC-7000 PACKAGING, SHIPPING, AND STORAGE
348 ARTICLE FC-8000 QUALITY ASSURANCE
349 ARTICLE FC-9000 NAMEPLATES
350 MANDATORY APPENDIX FC-I FILTER MEDIA: FIRE-RESISTANT, HIGH EFFICIENCY
359 NONMANDATORY APPENDIX FC-A DIVISION OF RESPONSIBILITY
360 SECTION FD TYPE II ADSORBER CELLS
ARTICLE FD-1000 INTRODUCTION
361 ARTICLE FD-2000 REFERENCED DOCUMENTS
362 ARTICLE FD-3000 MATERIALS
364 ARTICLE FD-4000 DESIGN
365 Figure
FIG. FD-4100 TYPE II ADSORBER CELL
367 ARTICLE FD-5000 INSPECTION AND TESTING
368 Tables
TABLE FD-5332 DETECTOR SENSITIVITY FOR LEAK TEST
369 ARTICLE FD-6000 FABRICATION
TABLE FD-6100 CELL DIMENSIONS AND TOLERANCES
370 ARTICLE FD-7000 PACKAGING AND SHIPPING
371 ARTICLE FD-8000 QUALITY ASSURANCE
372 ARTICLE FD-9000 NAMEPLATES AND CERTIFICATION
373 MANDATORY APPENDIX FD-I CALCULATION OF RESIDENCE TIME OF ADSORBER CELLS
374 MANDATORY APPENDIX FD-II SAMPLE CANISTERS
381 NONMANDATORY APPENDIX FD-A DIVISION OF RESPONSIBILITY
382 SECTION FE TYPE III ADSORBERS
ARTICLE FE-1000 INTRODUCTION
384 ARTICLE FE-2000 REFERENCED DOCUMENTS
385 ARTICLE FE-3000 MATERIALS
386 ARTICLE FE-4000 DESIGN
387 Figure
FIG. FE-4110 HORIZONTAL SECTION OF TYPE III ADSORBER BED
391 ARTICLE FE-5000 INSPECTION AND TESTING
393 ARTICLE FE-6000 FABRICATION AND INSTALLATION
394 ARTICLE FE-7000 PACKAGING AND SHIPPING
395 ARTICLE FE-8000 QUALITY ASSURANCE
396 ARTICLE FE-9000 NAMEPLATES
397 MANDATORY APPENDIX FE-I RESIDENCE TIME CALCULATION
398 MANDATORY APPENDIX FE-II SCREEN WAVINESS INSPECTION TEST
401 MANDATORY APPENDIX FE-III ADSORBER FILLING QUALIFICATION TEST PROCEDURE
407 MANDATORY APPENDIX FE-IV TYPE III ADSORBER QUALIFICATION TEST PROCEDURE
414 MANDATORY APPENDIX FE-V SAMPLE CANISTERS
419 NONMANDATORY APPENDIX FE-A VISUAL INSPECTION RECOMMENDATIONS FOR TYPE III ADSORBERS
420 NONMANDATORY APPENDIX FE-B DIVISION OF RESPONSIBILITY
421 SECTION FF ADSORBENT MEDIA
ARTICLE FF-1000 INTRODUCTION
423 ARTICLE FF-2000 REFERENCED DOCUMENTS
424 ARTICLE FF-3000 MATERIALS
425 ARTICLE FF-4000 DESIGN
426 ARTICLE FF-5000 INSPECTION AND TESTING
428 ARTICLE FF-6000 FABRICATION
429 ARTICLE FF-7000 PACKAGING AND SHIPPING
430 ARTICLE FF-8000 QUALITY ASSURANCE
431 ARTICLE FF-9000 NAMEPLATE AND CERTIFICATION
432 NONMANDATORY APPENDIX FF-A DIVISION OF RESPONSIBILITY
433 SECTION FG MOUNTING FRAMES FOR AIR-CLEANING EQUIPMENT
ARTICLE FG-1000 INTRODUCTION
434 ARTICLE FG-2000 REFERENCED DOCUMENTS
435 ARTICLE FG-3000 MATERIALS
436 ARTICLE FG-4000 DESIGN
437 Figures
FIG. FG-4110-1 TYPICAL FILTER MOUNTING FRAME
438 FIG. FG-4120-1 TYPICAL TYPE II ADSORBER MOUNTING FRAME
439 FIG. FG-4140-1 TYPICAL MOISTURE SEPARATOR MOUNTING FRAME
442 ARTICLE FG-5000 INSPECTION AND TESTING
444 ARTICLE FG-6000 FABRICATION
445 ARTICLE FG-7000 PACKAGING AND SHIPPING
446 ARTICLE FG-8000 QUALITY ASSURANCE
447 ARTICLE FG-9000 NAMEPLATES
448 NONMANDATORY APPENDIX FG-A DIVISION OF RESPONSIBILITY
451 SECTION FH OTHER ADSORBERS
ARTICLE FH-1000 INTRODUCTION
452 ARTICLE FH-2000 REFERENCED DOCUMENTS
453 ARTICLE FH-3000 MATERIALS
455 ARTICLE FH-4000 DESIGN
456 Figures
FIG. FH-4000-1 TYPE IV “V” ADSORBERS MODEL (FLUID SEAL VERSION)
457 FIG. FH-4000-1A TYPE IV “V” BED ADSORBERS MODEL (GASKETED VERSION)
458 FIG. FH-4000-2 TYPE IV “V” ADSORBERS MODEL, EXPLODED VIEW
459 FIG. FH-4000-3 TYPE IV “U” BED ADSORBERS MODEL (GASKETED VERSION)
460 ARTICLE FH-5000 INSPECTION AND TESTING
462 ARTICLE FH-6000 FABRICATION
Table
TABLE FH-6100 DIMENSIONAL REQUIREMENTS
463 ARTICLE FH-7000 PACKAGING AND SHIPPING
464 ARTICLE FH-8000 QUALITY ASSURANCE
465 ARTICLE FH-9000 NAMEPLATES AND CERTIFICATION
466 NONMANDATORY APPENDIX FH-A DIVISION OF RESPONSIBILITY
467 SECTION FI METAL MEDIA FILTERS
468 SECTION FJ LOW EFFICIENCY FILTERS
ARTICLE FJ-1000 INTRODUCTION
469 ARTICLE FJ-2000 REFERENCED DOCUMENTS
470 ARTICLE FJ-3000 MATERIALS
471 ARTICLE FJ-4000 DESIGN
472 ARTICLE FJ-5000 INSPECTION AND TESTING
473 ARTICLE FJ-6000 FABRICATION
474 ARTICLE FJ-7000 PACKAGING, SHIPPING, RECEIVING, STORAGE, AND HANDLING
475 ARTICLE FJ-8000 QUALITY ASSURANCE
476 ARTICLE FJ-9000 LABELS AND MARKINGS
477 NONMANDATORY APPENDIX FJ-A DIVISION OF RESPONSIBILITY
478 SECTION FK SPECIAL HEPA FILTERS
ARTICLE FK-1000 INTRODUCTION
480 ARTICLE FK-2000 REFERENCED DOCUMENTS
481 ARTICLE FK-3000 MATERIALS
483 ARTICLE FK-4000 DESIGN
Tables
TABLE FK-4000-1 TYPE 1 RADIAL FLOW HEPA FILTER – NOMINAL RATING
484 Figures
FIG. FK-4100-1 TYPE 1 RADIAL FLOW HEPA FILTER (INTERNAL GASKET), MIDSECTION VIEW
485 FIG. FK-4100-2 TYPE 1 RADIAL FLOW HEPA FILTER (INTERNAL GELATINOUS SEAL), MIDSECTION VIEW
486 FIG. FK-4100-3 TYPE 1 RADIAL FLOW HEPA FILTER (EXTERNAL GASKET), MIDSECTION VIEW
487 FIG. FK-4100-4 TYPE 1 RADIAL FLOW HEPA FILTER (EXTERNAL GELATINOUS SEAL), MIDSECTION VIEW
488 FIG. FK-4100-5 TYPE 2 AXIAL FLOW CIRCULAR HEPA FILTER
TABLE FK-4000-2 TYPE 2 AXIAL FLOW CIRCULAR HEPA FILTER – NOMINAL RATING
489 FIG. FK-4100-6 TYPE 2 AXIAL FLOW CIRCULAR HEPA FILTER
492 TABLE FK-4000-3 PERFORMANCE REQUIREMENTS
493 ARTICLE FK-5000 QUALIFICATION, INSPECTION, AND PRODUCTIONTESTING
494 TABLE FK-5000-1 TEST GROUPS AND SEQUENCE – TYPE 1 RADIAL FLOW HEPA FILTERS
495 TABLE FK-5000-2 TEST GROUPS AND SEQUENCE – TYPE 2 AXIAL FLOW CIRCULAR HEPA FILTERS
498 TABLE FK-5000-3 TEST GROUPS AND SEQUENCE – TYPE 4 AXIAL FLOW RECTANGULAR HEPA FILTERS
499 TABLE FK-5000-4 TEST CONDITIONS AND REQUIREMENTS
501 ARTICLE FK-6000 FABRICATION
502 ARTICLE FK-7000 PACKAGING, SHIPPING, AND STORAGE
503 ARTICLE FK-8000 QUALITY ASSURANCE
504 ARTICLE FK-9000 NAMEPLATES
505 NONMANDATORY APPENDIX FK-ADETERMINATION OF HEPA FILTER SERVICE LIFE
506 NONMANDATORY APPENDIX FK-BDIVISION OF RESPONSIBILITY
507 SECTION FL DEEP BED SAND FILTERS
ARTICLE FL-1000 INTRODUCTION
509 ARTICLE FL-2000 REFERENCED DOCUMENTS
510 ARTICLE FL-3000 MATERIALS
512 ARTICLE FL-4000 DESIGN
513 Figures
FIG. FL-4120-1 TYPICAL DBS FILTER CROSS SECTION, DOE-HDBK-1169-2003
515 ARTICLE FL-5000 INSPECTION AND TESTING
519 ARTICLE FL-6000 FABRICATION/FIELD CONSTRUCTION
521 ARTICLE FL-7000 PACKAGING, SHIPPING, RECEIVING,STORAGE, AND HANDLING
522 ARTICLE FL-8000 QUALITY ASSURANCE
523 ARTICLE FL-9000 LABELS AND MARKINGS
524 MANDATORY APPENDIX FL-I AIR-AEROSOL MIXING TEST PROCEDURAL GUIDELINES
528 MANDATORY APPENDIX FL-II DEEP BED SAND FILTER IN-PLACELEAK TEST PROCEDURAL GUIDELINES
531 NONMANDATORY APPENDIX FL-A DIVISION OF RESPONSIBILITY
532 NONMANDATORY APPENDIX FL-B GUIDELINES FOR DEEP BED SAND FILTERS
540 SECTION FM HIGH-STRENGTH HEPA FILTERS
541 SECTION IA INSTRUMENTATION AND CONTROLS
ARTICLE IA-1000 INTRODUCTION
543 ARTICLE IA-2000 REFERENCED DOCUMENTS
545 ARTICLE IA-3000 MATERIALS
546 Table
TABLE IA-3100 ALLOWABLE MATERIALS
547 ARTICLE IA-4000 DESIGN REQUIREMENTS
553 ARTICLE IA-5000 INSPECTION AND TESTING
555 ARTICLE IA-6000 PANEL FABRICATION AND ASSEMBLY
557 ARTICLE IA-7000 PACKAGING, SHIPPING, RECEIVING, STORAGE, AND HANDLING
558 ARTICLE IA-8000 QUALITY ASSURANCE
559 ARTICLE IA-9000 NAMEPLATES
560 NONMANDATORY APPENDIX IA-A DIVISION OF RESPONSIBILITY
562 NONMANDATORY APPENDIX IA-B SAMPLE CHECKLIST FOR VISUAL EXAMINATION OF CONTROL PANELS/ENCLOSURES, INSTRUMENTS, AND CONTROL DEVICES
563 NONMANDATORY APPENDIX IA-C INSTRUMENTATION FOR NUCLEAR AIR AND GAS TREATMENT SYSTEMS
566 Division III Process Gas Treatment
567 SECTION GA PRESSURE VESSELS, PIPING, HEAT EXCHANGERS, AND VALVES
568 SECTION GB NOBLE GAS HOLD-UP EQUIPMENT
569 SECTION GC GAS COMPRESSORS AND EXHAUSTERS
ARTICLE GC-1000 INTRODUCTION
571 ARTICLE GC-2000 REFERENCED DOCUMENTS
572 ARTICLE GC-3000 MATERIALS
573 ARTICLE GC-4000 DESIGN
579 ARTICLE GC-5000 INSPECTION AND TESTING
581 ARTICLE GC-6000 FABRICATION AND INSTALLATION
582 ARTICLE GC-7000 PACKAGING, SHIPPING, RECEIVING, AND STORAGE
583 ARTICLE GC-8000 QUALITY ASSURANCE
584 ARTICLE GC-9000 NAMEPLATES AND OPERATING AND MAINTENANCE MANUALS
585 MANDATORY APPENDIX GC-I SHAFT LEAKAGE
586 MANDATORY APPENDIX GC-II SYSTEM CONSIDERATIONS
588 NONMANDATORY APPENDIX GC-A DIVISION OF RESPONSIBILITY
590 SECTION GD OTHER RADIONUCLIDE EQUIPMENT
591 SECTION GE HYDROGEN RECOMBINERS
592 SECTION GF GAS SAMPLING
593 SECTION GG SCRUBBERS
594 SECTION GH CYCLONES
595 SECTION GI MEMBRANES
596 SECTION GJ FILTERS
597 SECTION GK MIST ELIMINATORS
598 SECTION GL ELASTOMERIC PRECIPITATORS
599 SECTION GM ADSORBENT MEDIA
600 Division IV Testing Procedures
601 SECTION TA FIELD TESTING OF AIR TREATMENT SYSTEMS
ARTICLE TA-1000 INTRODUCTION
603 ARTICLE TA-2000 REFERENCED DOCUMENTS
604 ARTICLE TA-3000 GENERAL INSPECTION AND TEST REQUIREMENTS
605 Tables
TABLE TA-3200 INSTRUMENT ACCURACY REQUIREMENTS
608 ARTICLE TA-4000 FIELD ACCEPTANCE TESTS
609 TABLE TA-4110 FAN ACCEPTANCE TESTS
610 TABLE TA-4210 DAMPER ACCEPTANCE TESTS
611 TABLE TA-4310 DUCT, HOUSING, AND FRAME ACCEPTANCE TESTS
612 TABLE TA-4410 REFRIGERATION EQUIPMENT ACCEPTANCE TESTS
614 TABLE TA-4510 CONDITIONING EQUIPMENT ACCEPTANCE TESTS
616 TABLE TA-4610 MOISTURE SEPARATOR, PREFILTER, AND HEPA FILTER ACCEPTANCE TESTS
617 TABLE TA-4710 TYPES II, III, AND IV ADSORBER BANK ACCEPTANCE TESTS
620 ARTICLE TA-5000 CORRECTIVE ACTION REQUIREMENTS
621 ARTICLE TA-6000 QUALITY ASSURANCE
622 MANDATORY APPENDIX TA-I VISUAL INSPECTION CHECKLIST
624 MANDATORY APPENDIX TA-II STRUCTURAL CAPABILITYTEST PROCEDURAL GUIDELINES
629 MANDATORY APPENDIX TA-III DUCT AND HOUSING LEAK TEST PROCEDURAL GUIDELINES
634 MANDATORY APPENDIX TA-IV AIRFLOW DISTRIBUTION TEST PROCEDURAL GUIDELINES
638 MANDATORY APPENDIX TA-V AIR-AEROSOL MIXING TEST PROCEDURAL GUIDELINES
642 MANDATORY APPENDIX TA-VI HEPA FILTER BANK IN-PLACE LEAK TEST PROCEDURAL GUIDELINES
646 MANDATORY APPENDIX TA-VII ADSORBER BANK IN-PLACE LEAK TEST PROCEDURAL GUIDELINES
650 MANDATORY APPENDIX TA-VIII REFRIGERANT PIPING AND COIL SYSTEM LEAK TEST PROCEDURAL GUIDELINES
654 NONMANDATORY APPENDIX TA-A MOUNTING FRAME PRESSURE LEAK TEST PROCEDURAL GUIDELINES
658 NONMANDATORY APPENDIX TA-B CORRECTIVE ACTION GUIDANCE
659 NONMANDATORY APPENDIX TA-C CHALLENGE GAS AND AEROSOL SUBSTITUTE SELECTION CRITERIA
660 SECTION TB FIELD TESTING OF GAS-PROCESSING SYSTEMS
662 MANDATORY APPENDIX I PREPARATION OF TECHNICAL INQUIRIES TO THE COMMITTEE ON NUCLEAR AIR AND GAS TREATMENT
664 NONMANDATORY APPENDIX A FORMAT GUIDE FOR TECHNICAL INQUIRIES
666 ASME AG-1 INTERPRETATIONS
ASME AG 1 2015
$98.04