D4766-98(2003) Standard Test Method for Vinyl Chloride in Workplace Atmospheres (Charcoal Tube Method)

Published By Publication Date Number of Pages
ASTM 2003 7
Guaranteed Safe Checkout
Categories: ,

If you have any questions, feel free to reach out to our online customer service team by clicking on the bottom right corner. We’re here to assist you 24/7.
Email:[email protected]

1.1 This test method describes the determination of vinyl chloride monomer (VCM) in workplace atmospheres using a modified charcoal tube method (see Practice D3686).

1.2 This procedure is compatible with low flow rate personal sampling equipment. It can be used for personnel or stationary monitoring. It cannot determine instantaneous fluctuations in concentration to detect maximum values. Alternative on-site procedures, such as gas chromatography or infrared spectrometry, must be used to measure fast-changing concentrations.

1.3 The range of this test method is from the limit of detection of approximately 0.01 to 100 ppm.

1.4 The sampling method provides a time-weighted average sample.

1.5 This standard does not purport to address all of the safety problems, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety and health practices and determine the applicability of regulatory limitations prior to use. For more specific precautionary statements, see Section 9 and Notes 2 and 4.

PDF Catalog

PDF Pages PDF Title
1 Scope
Referenced Documents
Terminology
Summary of Test Method
Significance and Use
2 Interferences
Apparatus
TABLE 1
3 Reagents
Safety Precautions
Calibration and Standardization
TABLE 2
4 Procedure
Calculations
5 Precision
Keywords
A1. ADSORPTION/DESORPTION EFFICIENCY
A1.1
A1.2
A1.3
A1.4
A1.5
A1.6
A1.7
A1.8
6 A1.9
A2. BREAKTHROUGH VOLUME
A2.1
A2.2
A2.3
A2.4
A2.5
A2.6
A2.7
REFERENCES