1.1 This practice is intended for determining volatile organic compound (VOC) emissions from materials and products (building materials, material systems, furniture, consumer products, etc.) and equipment (printers, photocopiers, air cleaners, etc.) under environmental and product usage conditions that are typical of those found in office and residential buildings.
1.2 This practice is for identifying VOCs emitted and determining their emission rates over a period of time.
1.3 This practice describes the design, construction, performance evaluation, and use of full-scale chambers for VOC emission testing.
1.4 While this practice is limited to the measurement of VOC emissions, many of the general principles and procedures (such as methods for evaluating the general performance of the chamber system) may also be useful for the determination of other chemical emissions (for example, ozone, nitrogen dioxide). Determination of aerosol and particle emissions is beyond the scope of this document.
PDF Catalog
PDF Pages | PDF Title |
---|---|
1 | Scope Referenced Documents |
2 | Terminology Summary of Practice Significance and Use |
3 | Principles |
5 | Facilities and Equipment |
7 | FIG. 1 FIG. 2 |
10 | Performance Evaluation |
11 | TABLE 1 |
16 | Collection and Preparation of the Test Specimen Test Procedure |
17 | Data Analysis and Interpretation |
18 | Report of the Test Results |
19 | Quality Control and Quality Assurance Keywords TABLE 2 |
20 | REFERENCES |