ASTM-E2303 2003

$40.63

E2303-03 Standard Guide for Absorbed-Dose Mapping in Radiation Processing Facilities

Published By Publication Date Number of Pages
ASTM 2003 9
Guaranteed Safe Checkout
Category:

If you have any questions, feel free to reach out to our online customer service team by clicking on the bottom right corner. We’re here to assist you 24/7.
Email:[email protected]

1.1 This document provides guidance in determining absorbed-dose distributions in products, materials or substances irradiated in gamma, X-ray (bremsstrahlung) and electron beam facilities.

Note 1For irradiation of food and the radiation sterilization of health care products, other specific ISO and ISO/ASTM standards containing dose mapping requirements exist. For food irradiation, see ISO/ASTM 51204, Practice for Dosimetry in Gamma Irradiation Facilities for Food Processing and ISO/ASTM 51431, Practice for Dosimetry in Electron and Bremsstrahlung Irradiation Facilities for Food Processing. For the radiation sterilization of health care products, see ISO 11137: 1995, Sterilization of Health Care Products Requirements for Validation and Routine Control Radiation Sterilization. In those areas covered by ISO 11137, that standard takes precedence. ISO/ASTM Practice 51608, ISO/ASTM Practice 51649, and ISO/ASTM Practice 51702 also contain dose mapping requirements.

1.2 Methods of analyzing the dose map data are described. Examples are provided of statistical methods that may be used to analyze dose map data.

1.3 Dose mapping for bulk flow processing and fluid streams is not discussed.

1.4 Dosimetry is only one component of a total quality program for an irradiation facility. Other controls besides dosimetry may be required for specific applications such as medical device sterilization and food preservation.

1.5 This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety and health practices and determine the applicability of regulatory requirements prior to use.

PDF Catalog

PDF Pages PDF Title
1 Scope
Referenced Documents
2 Terminology
Significance and Use
3 Prerequisites
Dose Mapping
4 FIG. 1
5 Analysis of Dose Map Data
Measurement Uncertainty
6 Documentation Accumulation
Keywords
X1. DETERMINING ZONES OF EQUIVALENT DOSE AND ESTABLISHING ZONES OF MAXIMUM AND MINIMUM DOSE EXTREMES
X1.1 Defining Statistically Equivalent Dose Zones
X1.2 Estimating Statistical Uncertainty within Zones
X1.3 Statistical Uncertainty within Zones Using Mean and Standard Deviation
7 FIG. X1.1
8 X1.4 Identifying Equivalent Zones Using Parametric Statistics
X1.5 Identifying Equivalent Zones with Non-Parametric Statistics
9 X2. ESTIMATING A DOSE EXTREME FROM A REFERENCE ZONE
X2.1