ASTM-F2471:2008 Edition(Redline)

$23.40

F2471-08 Standard Practice for Installation of Thick Poured Lightweight Cellular Concrete Underlayments and Preparation of the Surface to Receive Resilient Flooring (Redline)

Published By Publication Date Number of Pages
ASTM 2008 4
Guaranteed Safe Checkout
Categories: ,

If you have any questions, feel free to reach out to our online customer service team by clicking on the bottom right corner. We’re here to assist you 24/7.
Email:[email protected]

Significance and Use

This practice provides minimum recommendations for the installation of thick poured lightweight cellular concrete floor underlayments suitable to receive resilient floor coverings. This practice establishes the proper preparation, installation and quality control for thick poured lightweight cellular concrete floor underlayments.

Actual requirements for thick poured lightweight cellular concrete underlayments are generally included as part of project plans or specifications and may vary from the recommendations set forth in this practice. Project plans or specifications, or both, shall supersede the recommendations set forth in this practice.

1. Scope

1.1 This practice covers the installation and preparation of the thick poured lightweight cellular concrete underlayments over wood structural panel subfloors in commercial structures or over concrete floors in commercial structures and the preparation of the thick poured lightweight cellular concrete underlayment surface prior to the installation of resilient flooring in commercial buildings.

1.2 This practice points out the factors that are required to be controlled while installing thick poured lightweight cellular concrete underlayment as a base for resilient flooring.

1.3 This practice does not cover the structural adequacy of the wood structural panel subfloor or concrete subfloor. The structural integrity of assemblies is governed by local building codes.

1.4 This practice does not supercede the thick poured lightweight cellular concrete underlayment manufacturers’, adhesive manufacturers’ or resilient flooring manufacturers’ written instructions. Consult the individual manufacturer for specific recommendations.

1.5 Thick poured lightweight cellular concrete underlayments are not suitable for use on concrete slabs on ground due to potential moisture problems arising from moisture intrusion, unless an adequate vapor retarder or vapor barrier is present directly beneath the concrete subfloor.

1.6 The values stated in inch-pound units are to be regarded as standard. The values stated in parentheses are mathematical conversions to SI Units, which are provided for information only.

1.7 This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety and health practices and determine the applicability of regulatory limitations prior to use.

2. Referenced Documents (purchase separately) The documents listed below are referenced within the subject standard but are not provided as part of the standard.

ASTM Standards

C330 Specification for Lightweight Aggregates for Structural Concrete F141 Terminology Relating to Resilient Floor Coverings F710 Practice for Preparing Concrete Floors to Receive Resilient Flooring F1482 Practice for Installation and Preparation of Panel Type Underlayments to Receive Resilient Flooring F2170 Test Method for Determining Relative Humidity in Concrete Floor Slabs Using in situ Probes

Keywords

cellular; concrete; flooring; practice; resilient; sound mat; thick poured lightweight cellular concrete; underlayment; Cellular concrete; Concrete flooring; Resilient flooring; Thick poured lightweight cellular concrete; Underlayment products/applications;

ICS Code

ICS Number Code 91.100.30 (Concrete and concrete products)

DOI: 10.1520/F2471-08 ASTM International is a member of CrossRef.

Citing ASTM Standards

[Back to Top]

ASTM-F2471
$23.40