ASTM-F773M 2003

$40.63

F773M-96(2003) Practice for Measuring Dose Rate Response of Linear Integrated Circuits [Metric]

Published By Publication Date Number of Pages
ASTM 2003 5
Guaranteed Safe Checkout
Categories: ,

If you have any questions, feel free to reach out to our online customer service team by clicking on the bottom right corner. We’re here to assist you 24/7.
Email:[email protected]

ASTM F773M-96-Reapproved2003

Historical Standard: Practice for Measuring Dose Rate Response of Linear Integrated Circuits [Metric]

ASTM F773M

Scope

1.1 This practice covers the measurement of the response of linear integrated circuits, under given operating conditions, to pulsed ionizing radiation. The response may be either transient or more lasting, such as latchup. The radiation source is either a flash X-ray machine (FXR) or an electron linear accelerator (LINAC).

1.2 The precision of the measurement depends on the homogeneity of the radiation field and on the precision of the radiation dosimetry and the recording instrumentation.

1.3 The test may be considered to be destructive either for further tests or for other purposes if the total radiation dose exceeds some predetermined level or if the part should latch up. Because this level depends both on the kind of integrated circuit and on the application, a specific value must be agreed upon by the parties to the test. (See 6.10.)

1.4 Setup, calibration, and test circuit evaluation procedures are included in this practice.

1.5 Procedures for lot qualification and sampling are not included in this practice.

1.6 Because response varies with different device types, the dose rate range for any specific test is not given in this practice but must be agreed upon by the parties to the test.

1.7 This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety and health practices and determine the applicability of regulatory limitations prior to use.

Keywords

circuit response; dose rate; integrated circuit; ionizing radiaion; linear circuts; linear integrated circuits; pulsed radiation; transient response

ICS Code

ICS Number Code 17.220.20 (Measurement of electrical and magnetic quantities)

DOI: 10.1520/F0773M-96R03

PDF Catalog