Shopping Cart

No products in the cart.

BS EN 12101-6:2022 – TC

$258.95

Tracked Changes. Smoke and heat control systems – Specification for pressure differential systems. Kits

Published By Publication Date Number of Pages
BSI 2022 226
Guaranteed Safe Checkout
Categories: ,

If you have any questions, feel free to reach out to our online customer service team by clicking on the bottom right corner. We’re here to assist you 24/7.
Email:[email protected]

This document applies to pressure differential system kits and components, positioned on the market and intended to operate as part of a pressure differential system. The purpose of a pressure differential system is to prevent protected spaces from smoke spread by using pressure difference and airflow. This document specifies characteristics and test methods for components and kits for pressure differential systems to produce and control the required pressure differential and airflow between protected and unprotected space.

PDF Catalog

PDF Pages PDF Title
1 30462306
157 A-30390431
158 undefined
165 1 Scope
2 Normative references
3 Terms, definitions, symbols and abbreviated terms
3.1 Terms, definitions and abbreviated terms
167 3.2 Symbols
168 4 Characteristics
4.1 General
169 4.2 Nominal activation conditions/sensitivity
4.2.1 Kit
4.2.2 Components
4.2.2.1 Natural smoke and heat exhaust ventilators
4.2.2.2 Pressure control dampers (e.g. barometric dampers, motorized control dampers)
4.2.2.3 Fans
170 4.2.2.4 Smoke control ducts
4.2.2.5 Smoke control dampers
4.2.2.6 Hot gas control dampers
4.3 Response delay (response time)
4.3.1 Kit
4.3.1.1 General
4.3.1.2 Initial response time
4.3.1.3 Response time of door opening and door closing
4.3.2 Components
4.3.2.1 General
4.3.2.2 Natural smoke and heat exhaust ventilators
4.3.2.3 Pressure control dampers (e.g. barometric dampers, motorized control dampers)
171 4.3.2.4 Fans
4.3.2.5 Smoke control ducts
4.3.2.6 Smoke control dampers
4.3.2.7 Hot gas control dampers
4.4 Operational reliability
4.4.1 Kit
4.4.2 Components
4.4.2.1 Natural smoke and heat exhaust ventilators
4.4.2.2 Pressure control dampers (e.g. barometric dampers, motorized control dampers)
4.4.2.3 Fans
172 4.4.2.4 Smoke control ducts
4.4.2.5 Smoke control dampers
4.4.2.6 Hot gas control dampers
4.5 Effectiveness of smoke/hot gas extraction (air release/powered air release)
4.5.1 Kit
4.5.2 Components
4.5.2.1 Natural smoke and heat exhaust ventilators
4.5.2.2 Pressure control dampers (e.g. barometric dampers, motorized control dampers)
4.5.2.3 Fans
4.5.2.4 Smoke control ducts
4.5.2.5 Smoke control dampers
173 4.5.2.6 Hot gas control dampers
4.6 Performance parameters under fire conditions
4.6.1 Kit
4.6.2 Components
4.6.2.1 Natural smoke and heat exhaust ventilators
4.6.2.2 Pressure control dampers (e.g. barometric dampers, motorized control dampers)
4.6.2.3 Fans
4.6.2.4 Smoke control ducts
4.6.2.5 Smoke control dampers
4.6.2.6 Hot gas control dampers
4.7 Pressurization performance
4.7.1 Kit
174 4.7.2 Components
4.7.2.1 Natural smoke and heat exhaust ventilators
4.7.2.2 Pressure control dampers (e.g. barometric dampers, motorized control dampers)
4.7.2.3 Fans
4.7.2.4 Smoke control ducts
4.7.2.5 Smoke control dampers
4.7.2.6 Hot gas control dampers
4.8 Fire resistance – Integrity (E)
4.8.1 Kit
4.8.2 Components
4.8.2.1 Natural smoke and heat exhaust ventilators
4.8.2.2 Pressure control dampers (e.g. barometric dampers, motorized control dampers)
4.8.2.3 Fans
175 4.8.2.4 Smoke control ducts
4.8.2.5 Smoke control dampers
4.8.2.6 Hot gas control dampers
4.9 Fire resistance – Insulation (I)
4.9.1 Kit
4.9.2 Components
4.9.2.1 Natural smoke and heat exhaust ventilators
4.9.2.2 Pressure control dampers (e.g. barometric dampers, motorized control dampers)
4.9.2.3 Fans
4.9.2.4 Smoke control ducts
176 4.9.2.5 Smoke control dampers
4.9.2.6 Hot gas control dampers
4.10 Fire resistance – Smoke leakage (S)
4.10.1 Kit
4.10.2 Components
4.10.2.1 Natural smoke and heat exhaust ventilators
4.10.2.2 Pressure control dampers (e.g. barometric dampers, motorized control dampers)
4.10.2.3 Fans
4.10.2.4 Smoke control ducts
4.10.2.5 Smoke control dampers
4.10.2.6 Hot gas control dampers
177 4.11 Fire resistance – Mechanical stability
4.11.1 Kit
4.11.2 Components
4.11.2.1 Natural smoke and heat exhaust ventilators
4.11.2.2 Pressure control dampers (e.g. barometric dampers, motorized control dampers)
4.11.2.3 Fans
4.11.2.4 Smoke control ducts
4.11.2.5 Smoke control dampers
4.11.2.6 Hot gas control dampers
4.12 Fire resistance – Maintenance of cross section
4.12.1 Kit
178 4.12.2 Components
4.12.2.1 Natural smoke and heat exhaust ventilators
4.12.2.2 Pressure control dampers (e.g. barometric dampers, motorized control dampers)
4.12.2.3 Fans
4.12.2.4 Smoke control ducts
4.12.2.5 Smoke control dampers
4.12.2.6 Hot gas control dampers
4.13 Durability
4.13.1 Kit
4.13.2 Components
4.13.2.1 Natural smoke and heat exhaust ventilators
179 4.13.2.2 Pressure control dampers (e.g. barometric dampers, motorized control dampers)
4.13.2.3 Fans
4.13.2.4 Smoke control ducts
4.13.2.5 Smoke control dampers
4.13.2.6 Hot gas control dampers
5 Test methods
5.1 General
5.1.1 Kits
180 5.1.2 Families
5.1.3 Substitution of components from different families
5.2 Nominal activation conditions/sensitivity
5.2.1 Kit
5.2.2 Components
5.2.2.1 Natural smoke and heat exhaust ventilators
5.2.2.2 Pressure control dampers (e.g. barometric dampers, motorized control dampers)
5.2.2.3 Fans
181 5.2.2.4 Smoke control ducts
5.2.2.5 Smoke control dampers
5.2.2.6 Hot gas control dampers
5.3 Response delay (response time)
5.3.1 Kit
5.3.2 Components
5.3.2.1 Natural smoke and heat exhaust ventilators
5.3.2.2 Pressure control dampers (e.g. barometric dampers, motorized control dampers)
5.3.2.3 Fans
5.3.2.4 Smoke control ducts
5.3.2.5 Smoke control dampers
5.3.2.6 Hot gas control dampers
182 5.4 Operational reliability
5.4.1 Kit
5.4.1.1 Test rig
5.4.1.2 Requirements for test equipment
183 5.4.1.3 Test rig for pressurization
184 5.4.1.4 Test rig for PDS (pressurization with powered air release)
5.4.1.5 Description of the tests
185 5.4.1.6 Description of the subtests
5.4.1.7 Test cycle sequence
186 5.4.1.8 Functionality test (FU) n
5.4.1.9 Durability test (DU)
187 5.4.1.10 Oscillating test (OSC)
188 5.4.1.11 Description of test data
189 5.4.1.12 Performance classes
5.4.1.13 Testing procedure for modified performance parameters
5.4.1.14 Test criteria
191 5.4.1.15 Test report
192 5.4.2 Components
5.4.2.1 Natural smoke and heat exhaust ventilators
5.4.2.2 Pressure control dampers (e.g. barometric dampers, motorized control dampers)
5.4.2.3 Fans
5.4.2.4 Smoke control ducts
5.4.2.5 Smoke control dampers
5.4.2.6 Hot gas control dampers
5.5 Effectiveness of smoke/hot gas extraction
5.5.1 Kit
5.5.2 Components
5.5.2.1 Natural smoke and heat exhaust ventilators
5.5.2.2 Pressure control dampers (e.g. barometric dampers, motorized control dampers)
5.5.2.3 Fans
193 5.5.2.4 Smoke control ducts
5.5.2.5 Smoke control dampers
5.5.2.6 Hot gas control dampers
5.6 Performance parameters under fire conditions
5.6.1 Kit
5.6.2 Components
5.6.2.1 Natural smoke and heat exhaust ventilators
5.6.2.2 Pressure control dampers (e.g. barometric dampers, motorized control dampers)
5.6.2.3 Fans
5.6.2.4 Smoke control ducts
5.6.2.5 Smoke control dampers
5.6.2.6 Hot gas control dampers
5.7 Pressurization performance
5.7.1 Kit
194 5.7.2 Components
5.7.2.1 Natural smoke and heat exhaust ventilators
5.7.2.2 Pressure control dampers (e.g. barometric dampers, motorized control dampers)
5.7.2.3 Fans
5.7.2.4 Smoke control ducts
5.7.2.5 Smoke control dampers
5.7.2.6 Hot gas control dampers
5.8 Fire resistance – Integrity (E)
5.8.1 Kit
5.8.2 Components
5.8.2.1 Natural smoke and heat exhaust ventilators
5.8.2.2 Pressure control dampers (e.g. barometric dampers, motorized control dampers)
5.8.2.3 Fans
195 5.8.2.4 Smoke control ducts
5.8.2.5 Smoke control dampers
5.8.2.6 Hot gas control dampers
5.9 Fire resistance – Insulation (I)
5.9.1 Kit
5.9.2 Components
5.9.2.1 Natural smoke and heat exhaust ventilators
5.9.2.2 Pressure control dampers (e.g. barometric dampers, motorized control dampers)
5.9.2.3 Fans
5.9.2.4 Smoke control ducts
5.9.2.5 Smoke control dampers
5.9.2.6 Hot gas control dampers
5.10 Fire resistance – Smoke leakage (S)
5.10.1 Kit
196 5.10.2 Components
5.10.2.1 Natural smoke and heat exhaust ventilators
5.10.2.2 Pressure control dampers (e.g. barometric dampers, motorized control dampers)
5.10.2.3 Fans
5.10.2.4 Smoke control ducts
5.10.2.5 Smoke control dampers
5.10.2.6 Hot gas control dampers
5.11 Fire resistance – Mechanical stability
5.11.1 Kit
5.11.2 Components
5.11.2.1 Natural smoke and heat exhaust ventilators
5.11.2.2 Pressure control dampers (e.g. barometric dampers, motorized control dampers)
5.11.2.3 Fans
197 5.11.2.4 Smoke control ducts
5.11.2.5 Smoke control dampers
5.11.2.6 Hot gas control dampers
5.12 Fire resistance – Maintenance of cross section
5.12.1 Kit
5.12.2 Components
5.12.2.1 Natural smoke and heat exhaust ventilators
5.12.2.2 Pressure control dampers (e.g. barometric dampers, motorized control dampers)
5.12.2.3 Fans
5.12.2.4 Smoke control ducts
5.12.2.5 Smoke control dampers
5.12.2.6 Hot gas control dampers
5.13 Durability
5.13.1 Kit
198 5.13.2 Components
5.13.2.1 Natural smoke and heat exhaust ventilators
5.13.2.2 Pressure control dampers (e.g. barometric dampers, motorized control dampers)
5.13.2.3 Fans
5.13.2.4 Smoke control ducts
5.13.2.5 Smoke control dampers
5.13.2.6 Hot gas control dampers
6 Verification of performance
6.1 Type testing
6.1.1 General
199 6.1.2 Test samples, testing and compliance criteria
200 6.1.3 Test reports
6.2 Factory production control (FPC)
6.2.1 General
201 6.2.2 Requirements
6.2.2.1 General
202 6.2.2.2 Equipment
6.2.2.3 Raw materials and components
6.2.2.4 Traceability and marking
6.2.2.5 Controls during manufacturing process
6.2.2.6 Product testing and evaluation
6.2.2.7 Non-complying products
203 6.2.2.8 Corrective action
6.2.2.9 Handling, storage and packaging
6.2.3 Product specific requirements
204 7 Marking, labelling and packaging
205 Annex A (normative)Pressure differential kit types (pressurization)
A.1 General
A.2 Kit 1
A.2.1 Kit 1: Components
A.2.2 Kit 1: Key component(s):
207 A.2.3 Kit 1: Family
208 A.2.4 Kit 1: Selection of test specimen
209 A.3 Kit 2
A.3.1 Kit 2: Components
A.3.2 Kit 2: Key component(s):
210 A.3.3 Kit 2: Family
211 A.3.4 Kit 2: Selection of test specimen
212 A.4 Kit 3
A.4.1 Kit 3: Components
A.4.2 Kit 3: Key components
213 A.4.3 Kit 3: Family
A.4.3.1 The following characteristics and product properties shall be identical within a family:
214 A.4.3.2 Characteristics which may differ within a family under consideration of the fulfilled criteria of the tested sample:
A.4.4 Kit 3: Selection of test specimen
A.4.4.1 Option 1: Without calculation
A.4.4.2 Option 2: By calculation
215 A.4.5 Test
A.4.6 Other fundamental requirements
216 A.5 Fundamental kit X
A.5.1 Fundamental kit X: Components
A.5.2 Fundamental kit X: Key components
217 A.5.3 Kit X: Family
A.5.4 Kit X: Selection of test specimen
218 Annex B (normative)Test method for hot gas control damper at elevated temperature
B.1 Hot gas control damper
B.1.1 General
B.1.2 Classification
B.1.3 Test arrangement
219 B.1.4 System under test
B.1.5 Installation
B.2 Test procedure
B.2.1 General
B.2.2 Ambient conditions
220 B.2.3 General conditions for the elevated and high temperature tests
B.2.4 Furnace thermocouples
221 B.2.5 Heat up period for fire test with elevated temperatures
B.2.6 Elevated temperatures for classes HG 200 to HG 600
B.2.7 High temperature test for HG 842
222 Annex C (normative)Test required for powered smoke and heat exhaust ventilators with frequency inverter and operated with variable speed at elevated temperature
C.1 Mechanical smoke and heat exhaust ventilator (fan)
C.1.1 General
C.1.2 General cycle test
C.1.3 Preparation of fire test
C.1.4 Warm-up period
C.1.5 Fire test
224 Annex D (normative)Installation and maintenance document
D.1 Product, installation and maintenance documentation
D.1.1 Product specification
D.1.2 Installation information
D.1.3 Maintenance information
BS EN 12101-6:2022 - TC
$258.95