Shopping Cart

No products in the cart.

BS EN 50193-2-1:2016

$142.49

Electric instantaneous water heaters – Methods for measuring the performance. Multifunctional electric instantaneous water heaters

Published By Publication Date Number of Pages
BSI 2016 32
Guaranteed Safe Checkout
Categories: ,

If you have any questions, feel free to reach out to our online customer service team by clicking on the bottom right corner. We’re here to assist you 24/7.
Email:[email protected]

This European Standard applies to electrical instantaneous water heaters designed to operate as multifunctional appliances with electric rated power >2 kW. This European Standard specifies tests for the assessment of the performance.

PDF Catalog

PDF Pages PDF Title
6 European foreword
7 1 Scope
2 Normative references
3 Terms and definitions
8 Figure 101
9 101 Symbols and units
Table 101 – Symbols and units
4 General test conditions
10 4.4 Test setup
4.101 Time constants (measuring time)
4.102 Test setup
4.102.1 Measurement setup
4.102.2 Set points
4.102.3 Measurement of flow pressure and flow rate
4.102.4 Temperature measurement
5 Energy efficiency
6.101 Performance tests
6.101.1 General
6.101.2 Determination of flow rates
6.101.2.1 Introduction
11 6.101.2.2 Electronically controlled or regulated appliances
Table 102 – Nominal values for electronically controlled or regulated appliances
6.101.2.3 Hydraulically controlled appliances
12 Table 103 – Nominal values for hydraulically controlled appliances
6.101.2.4 Determination of the flow rate as a function of the pressure difference
Table 104 – Flow pressure and flow rate for multi point appliances
Table 105 – Flow pressure and flow rate for single point appliances
6.101.3 Pressure difference on activation of the heating capacity
6.101.3.1 Introduction
6.101.3.2 Electronically controlled or regulated appliances
Table 106 – Pressure difference and flow rate
6.101.3.3 Hydraulically controlled appliances
13 Table 107 – Pressure difference and flow rate
6.101.4 Behaviour at switch-on of the appliance
6.101.4.1 Introduction
6.101.4.2 Electronically controlled or regulated appliances
Table 108 – Behaviour at switch-on of the appliance at different temperature selector settings
14 6.101.4.3 Hydraulically controlled appliances
Table 109 – Behaviour at switch-on of the appliance at different settings
6.101.5 Behaviour following the change of the flow rate
6.101.5.1 Introduction
6.101.5.2 Electronically controlled or regulated appliances
15 Table 110 – Behaviour following the change of the flow rate at different temperature selector settings
6.101.5.3 Hydraulically controlled appliances
16 Table 111 – Behaviour following the change of the flow rate at different settings
6.101.6 Behaviour following interruption of the flow
6.101.6.1 Introduction
6.101.6.2 Electronically controlled or regulated appliances
17 Table 112 – Behaviour following interruption of the flow
6.101.6.3 Hydraulically controlled appliances
Table 113 – Behaviour following interruption of the flow
6.101.7 Behaviour at constant temperature setting
6.101.7.1 Introduction
6.101.7.2 Electronically controlled or regulated appliances
18 Table 114 – Behaviour at constant temperature setting
6.101.7.3 Hydraulically controlled appliances
6.101.8 Behaviour following the change of the temperature selector setting
6.101.8.1 Introduction
6.101.8.2 Electronically controlled appliances
19 Table 115 – Behaviour following the change of the temperature selector setting at a flow rate of 50 %
Table 116 – Behaviour following the change of the temperature selector setting at a flow rate of 100 %
6.101.8.3 Hydraulically controlled appliances
6.101.9 Behaviour at voltage limits
20 Table 117 – Behaviour at voltage limits
7.101 Additional tests for electronic instantaneous water heaters
7.101.1 General
7.101.2 Behaviour of the outlet temperature at decreasing water inlet temperature
Table 118 – Behaviour of the outlet temperature at decreasing water inlet temperature
21 7.101.3 Behavior of the outlet temperature at changing water inlet temperature
Table 119 – Behaviour of the outlet temperature following the increase of the water inlet temperature
22 Annex A (normative) Load pattern
23 Annex B (normative) Test setup
24 Figure B.103 – Test setup
25 Figure B.104 – Damping device (Detail 4)
Figure B.105 – Water connection part (Detail 5)
26 Figure B.106 – Water connection part (Detail 6)
27 Annex ZZA (informative) Relationship between this European Standard and the energy labelling requirements of Commission Delegated Regulation (EU) No 812/2013 aimed to be covered
Table ZZA.1 – Correspondence between this European Standard and Commission Delegated Regulation (EU) No 812/2013 of 18 February 2013 supplementing Directive 2010/30/EU of the European Parliament and of the Council with regard to energy labelling of wa…
28 Annex ZZB (informative) Relationship between this European Standard and the ecodesign requirements of Commission Regulation (EU) No 814/2013 aimed to be covered
Table ZZB.1 – Correspondence between this European Standard and Commission Regulation (EU) No 814/2013 of 2 August 2013 implementing Directive 2009/125/EC of the European Parliament and of the Council with regard to ecodesign requirements for water he…
29 Bibliography
BS EN 50193-2-1:2016