BS EN 50491-11:2015
$189.07
General requirements for Home and Building Electronic Systems (HBES) and Building Automation and Control Systems (BACS) – Smart Metering. Application Specifications. Simple External Consumer Display
Published By | Publication Date | Number of Pages |
BSI | 2015 | 50 |
This European Standard specifies a data model to abstract the metering world towards a simple external consumer display. The data model, as described by means of functional blocks contained in this European Standard, lays down the format of metering data accessible by a simple external consumer display. This data interface would be typically part of the meter communication functions and be accessed by a simple external consumer display via the H1 interface of the CEN/CLC/ETSI TR 50572 between the display and the meter communication functions. The data interface specified in this document may also be accessed by the LNAP or NNAP through the C or M interface, after which the data could be accessed by HBES devices through the H2 and H3 interface. In other words, in this way the same data model can be used both on the H1 as well as the H2 and H3 interface. The document specifies neither the communication mechanisms used on the data interface, nor the applied data privacy and security mechanisms nor the ergonomics of the simple external consumer displays, where national regulations may apply. The document does also not specify the communication protocol used between the meters and the meter communication functions. However, it takes into account the existing European standards like the EN 13757 series (in particular EN 13757-3:2013 and its Annex O) and the EN 62056 series for the definition of the data model.
PDF Catalog
PDF Pages | PDF Title |
---|---|
6 | Foreword |
7 | Introduction |
8 | 1 Scope 2 Normative References 3 Terms, definitions and abbreviations 3.1 Terms and definitions |
9 | 3.2 Abbreviations |
10 | 4 General reference model |
12 | 5 Requirements for the Data interface 5.1 General |
13 | 5.2 Minimization of data transmission 5.3 Data consistency 5.4 Filtering of message types and data points |
14 | 6 Conformity and Testing 7 Metering Functional Blocks of MDC 7.1 MDC Heat Meter (M_HEATM) 7.1.1 Aims and objectives 7.1.2 Functional specification 7.1.3 Constraints |
15 | 7.1.4 Data Point Overview |
17 | 7.2 MDC Heat Cost Allocator (M_HCA) 7.2.1 Aims and objectives 7.2.2 Functional specification 7.2.3 Constraints |
18 | 7.2.4 Data Point Overview |
19 | 7.3 MDC Water Meter (M_WATERM) 7.3.1 Aims and objectives 7.3.2 Functional specification 7.3.3 Constraints |
20 | 7.3.4 Data Point Overview |
21 | 7.4 MDC Generic Meter (M_GENERICM) 7.4.1 Aims and objectives 7.4.2 Functional specification |
22 | 7.4.3 Constraints 7.4.4 Data Point Overview |
23 | 7.5 MDC Gas Meter (M_GASM) 7.5.1 Aims and objectives 7.5.2 Functional specification |
24 | 7.5.3 Constraints 7.5.4 Data Point Overview |
25 | 7.6 MDC Electricity Meter (M_ELECM) 7.6.1 Aims and objectives 7.6.2 Functional specification |
26 | 7.6.3 Constraints 7.6.4 Data Point Overview |
28 | 7.7 MDC Breaker (M_BREAKERM) 7.7.1 Aims and objectives 7.7.2 Functional Specification 7.7.3 Constraints 7.7.4 Datapoint description |
29 | 7.8 MDC Valve (M_VALVEM) 7.8.1 Aims and objectives 7.8.2 Functional Specification |
30 | 7.8.3 Constraints 7.8.4 Datapoint description |
31 | 8 Metering Data model 8.1 Introduction 8.2 Boolean Value |
32 | 8.3 1-octet unsigned counter value 8.4 Datapoint Types 2-Octet Float Value” |
33 | 8.5 2-octet unsigned counter value 8.6 4-Octet Signed unsigned counter Value 8.7 4 Octet signed time period |
34 | 8.8 Datapoint Type “MeteringValue” 8.8.1 General 8.8.2 Coding General |
35 | 8.8.3 Coding VallnfField |
36 | 8.8.4 Coding Status 8.8.5 Recommended display format for metering data |
37 | 8.9 DPT Active Energy |
38 | 8.10 DPT for tariff information 8.11 DPT_Currency |
39 | 8.12 DPTs for Price Information 8.13 Format of DPT_DateTime 8.13.1 Coding |
40 | 8.13.2 Remarks to the coding of DPT_DateTime 8.13.2.1 Remarks to the field Year in DPT_DateTime 8.13.2.2 Remarks to the field Hour in DPT_DateTime |
41 | 8.13.2.3 Remarks to the field Fault in DPT_DateTime 8.13.2.4 Remarks to the field Standard Summer Time in DPT_DateTime 8.13.2.5 Remarks to the field No Day of the Week in DPT_DateTime 8.13.2.6 Remarks to the field Quality of Clock in DPT_DateTime |
43 | 8.14 Datapoint Type DPT_Metering_DeviceType |
44 | 8.15 Datapoint Type Character Set |
45 | 8.16 Datapoint Type DPT_VarString_8859_1 8.17 DPT_Gas_Measurement_Condition |
46 | 8.18 Datapoint Type DPT_Meter_BreakerValve_State 8.19 Datapoint Type DPT_Meter_Mode |
47 | 8.20 Datapoint Type DPT_Power_Threshold_Status 8.21 Datapoint Type DPT_Battery_Status |
48 | Bibliography |