Shopping Cart

No products in the cart.

BS EN 60172:2015 – TC:2020 Edition

$186.33

Tracked Changes. Test procedure for the determination of the temperature index of enamelled and tape wrapped winding wires

Published By Publication Date Number of Pages
BSI 2020 76
Guaranteed Safe Checkout
Categories: ,

If you have any questions, feel free to reach out to our online customer service team by clicking on the bottom right corner. We’re here to assist you 24/7.
Email:[email protected]

IEC 60172:2015 specifies, in accordance with the provisions of IEC 60216-1, a method for evaluating the temperature index of enamelled wire, varnished or unvarnished with an impregnating agent, and of tape wrapped round and rectangular wire, in air at atmospheric pressure by periodically monitoring changes in response to AC proof voltage tests. This procedure does not apply to fibre-insulated wire or wire covered with tapes containing inorganic fibres. This fourth edition cancels and replaces the third edition published in 1987, Amendment 1:1997 and Amendment 2:2010. This edition constitutes a technical revision. This edition includes the following significant technical changes with respect to the previous edition: – Revision of Clause 1, Scope, to incorporate appropriate text from former Clause 2, Object; – Deletion of Clause 2, Object, by placement of its text into existing clauses; – New Clause 2, Normative references; – Revision of 5.1.1, 5.3 and 5.4 with corrections to Amendment 2 to the third edition; – Revision of Clause 7 as to clarify which specimens comply with Table 3 and Table 4; – Revision of figures with high-resolution photos and graphs. Keywords: enamelled wire, tape wrapped round and rectangular wire, AC proof voltage tests

PDF Catalog

PDF Pages PDF Title
50 English
CONTENTS
52 FOREWORD
54 1 Scope
2 Normative references
3 Terms and definitions
55 4 Summary of procedure
5 Test specimens
5.1 Preparation
5.1.1 Enamelled round wire with a nominal conductor diameter of 0,224 mm up to and including 2,65 mm
56 Figures
Figure 1 – Device used to form enamelled round wire test specimen
Figure 2 – Spacer
Tables
Table 1 – Force and number of twists for specimens
57 Figure 3 – Twist forming jig
Figure 4 – Test specimen set up in forming jig
58 5.1.2 Tape wrapped round wire and enamelled or tape wrapped rectangular wire
Figure 5 – Test specimen formed with loop cut
Table 2 – Proof voltage for round enamelled wire
59 Figure 6 – Jig for bending large magnet wire, dielectric test specimen
60 5.2 Varnish impregnation
Figure 7 – Forming jig and test specimen
61 5.3 Notes on number of test specimens
5.4 Specimen holder
5.4.1 For specimens according to 5.1.1
Figure 8 – Specimen holder
62 5.4.2 For specimens according to 5.1.2
6 Temperature exposure
Figure 9 – Specimen holder and electrical connection fixture
63 Table 3 – Recommended exposure times in days per cycle
64 7 Test voltage and its application
8 Calculations
8.1 Specimen failure time
Table 4 – Proof voltage for tape-wrapped round and for enamelled or tape-wrapped rectangular wire
65 8.2 Time to failure
8.3 Linearity of data
8.4 Calculating and plotting thermal endurance and temperature index
66 9 Report
Figure 10 – Thermal endurance graph – Temperature index
67 Annex A (normative) Method for calculation of the regression line
69 Table A.1 – Commonly used test temperatures in degrees Celsius and the corresponding kelvins with its reciprocal and reciprocal squared values
70 Table A.2 – Sample calculation
71 Figure A.1 – Plot of regression line based on sample calculation (Table A.2)
72 Annex B (normative) Correlation coefficient
74 Bibliography
BS EN 60172:2015 - TC
$186.33