Shopping Cart

No products in the cart.

BS EN 61082-1:2015

$215.11

Preparation of documents used in electrotechnology – Rules

Published By Publication Date Number of Pages
BSI 2015 112
Guaranteed Safe Checkout
Category:

If you have any questions, feel free to reach out to our online customer service team by clicking on the bottom right corner. Weā€™re here to assist you 24/7.
Email:[email protected]

This part of IEC 61082 establishes general rules and guidelines for the presentation of information in documents, and specific rules for diagrams, drawings and tables used in electrotechnology.

Excluded from this part of IEC 61082 are rules and guidelines for all kind of audio or video or tactile presentations.

This horizontal standard is primarily intended for use by technical committees in the preparation of standards in accordance with the principles laid down in IEC Guide 108 .

One of the responsibilities of a technical committee is, wherever applicable, to make use of horizontal standards in the preparation of its publications. The contents of this horizontal standard will not apply unless specifically referred to or included in the relevant publications.

PDF Catalog

PDF Pages PDF Title
7 English
CONTENTS
13 INTRODUCTION
Figures
Figure 1 ā€“ Overview of standards related to the presentation of information in documents
14 1 Scope
2 Normative references
15 3 Terms and definitions
16 3.1 Basic terms
17 3.2 Terms related to the forms of presentation of information
18 3.3 Terms related to specific document kinds
19 4 Documentation principles
4.1 General considerations
4.2 Structure of documentation
20 4.3 Presentation of information
FigureĀ 2 ā€“ Documents generated from information stored in a database
21 4.4 Document identification and designation
5 Rules for presentation of information
5.1 Legibility
FigureĀ 3 ā€“ Documents prepared and stored in a database
22 5.2 Text orientation
5.3 Colours, shading and patterns
5.4 Paper page sizes
FigureĀ 4 ā€“ Viewing directions of a document
23 5.5 Paper page reproduction
5.6 Page identification
FigureĀ 5 ā€“ Examples of documents with document and page identifications
24 5.7 Page layout
5.7.1 General
FigureĀ 6 ā€“ Example of documents with multiple document identifiers
25 5.7.2 Identification area
5.7.3 Content area
FigureĀ 7 ā€“ Examples of pages with defined identification areas
27 FigureĀ 8 ā€“ Example of a reference grid
28 5.8 Cross-references
29 5.9 Hyperlinks
5.10 Line widths
FigureĀ 9 ā€“ Examples of the application of cross-references
30 5.11 Text fonts
5.12 Symbols
5.12.1 Choice of symbols
FigureĀ 10 ā€“ Example of the use of symbols for fibre optics
31 5.12.2 Symbol size
FigureĀ 11 ā€“ Example of replacing a symbol with a general symbol
FigureĀ 12 ā€“ Example of enlarging a symbol
32 5.12.3 Orientation of symbols
5.13 Scales
5.14 Pictorial presentation
5.15 Quantities, units, values and colour codes
5.16 Presentation of ranges and set of elements
FigureĀ 13 ā€“ Turning and/or mirroring of symbol S00055 in IECĀ 60617
34 5.17 Dimension lines
5.18 Leader lines and reference lines
FigureĀ 14 ā€“ Terminators of dimension lines (from ISOĀ 129)
FigureĀ 15 ā€“ Examples of leader lines (from ISOĀ 128-22)
FigureĀ 16 ā€“ Example of the use of leader lines to connecting lines
35 5.19 Explanatory notes and markings
5.20 Designation of objects
5.20.1 General
5.20.2 Reference designations
FigureĀ 17 ā€“ Example of an explanatory note
36 5.20.3 Simplified presentation
FigureĀ 18 ā€“ Presentation of reference designations and sets of reference designations
FigureĀ 19 ā€“ The common initial portion of reference designations
37 5.20.4 Cable core designations
5.21 Terminal designations
5.22 Signal designations
6 Document kinds
FigureĀ 20 ā€“ Examples of cable core designations
38 7 Diagrams
7.1 General
7.1.1 Flow of energy, signal, etc.
7.1.2 Symbols
FigureĀ 21 ā€“ Example of functional grouping and signal flow directions; a control system
39 FigureĀ 22 ā€“ Example of symbols and different location of connections
FigureĀ 23 ā€“ Simplified presentation
40 FigureĀ 24 ā€“ Simplified presentation of parallel connected identical objects
FigureĀ 25 ā€“ Simplified presentation of serial connected identical objects
41 7.1.3 Connecting lines
FigureĀ 26 ā€“ Example of cross-references related to detached presentations
FigureĀ 27 ā€“ Example for technical data associated with a symbol
FigureĀ 28 ā€“ Example of technical data shown inside a symbol
42 FigureĀ 29 ā€“ Symbols representing joining of connecting lines
FigureĀ 30 ā€“ Symbol representing the interconnection of crossing connecting lines
FigureĀ 31 ā€“ Examples of the joining of connecting lines
43 FigureĀ 32 ā€“ Example of the joining of connecting lines with indication of where the physical wire goes
FigureĀ 33 ā€“ Example of the joining of connecting lines where the connecting lines represent bundles of wires
44 FigureĀ 34 ā€“Different presentation methods for wireless interconnections
FigureĀ 35 ā€“ Example of presentations of mechanical links
45 FigureĀ 36 ā€“ Example for avoiding bends and cross-overs
FigureĀ 37 ā€“ Spacing of lines
46 FigureĀ 38 ā€“ Examples for technical data associated with connecting lines
47 7.1.4 Representation of binary logic circuits
FigureĀ 39 ā€“ Presentation of bundles
FigureĀ 40 ā€“ Indication of sequence within bundles
48 FigureĀ 41 ā€“ Illustration of the terms ā€œstatesā€ and ā€œlevelsā€
49 FigureĀ 42 ā€“ Detail of a circuit diagram using positive logic convention
FigureĀ 43 ā€“ Detail of a circuit diagram using direct logic polarity convention
50 7.1.5 Boundary frames
7.1.6 Presentation of reference designations
FigureĀ 44 ā€“ Boundary frame with a reference to another document
51 FigureĀ 45 ā€“ Location of reference designations at a symbol
FigureĀ 46 ā€“ Examples of reference designations associated with connecting lines
52 FigureĀ 47 ā€“ Presentation of reference designations at a boundary frame
53 FigureĀ 48 ā€“ Presentation of reference designations including different aspect
FigureĀ 49 ā€“ Presentation of reference designation sets at a boundary frame
54 FigureĀ 50 ā€“ Presentation of reference designation
FigureĀ 51 ā€“ Presentation of reference designations excluded from concatenation
55 7.1.7 Presentation of terminal designations
7.1.8 Presentation of signal designations
FigureĀ 52 ā€“ Examples for the presentation of terminal designations
FigureĀ 53 ā€“ Examples of signal designations associated with connecting lines
56 7.1.9 Method of presentation of multi-phase circuits
FigureĀ 54 ā€“ Examples of reference and signal designations ass. with connecting lines
FigureĀ 55 ā€“ Presentation of signal designations
57 7.1.10 Emphasizing of circuits
7.2 Overview diagrams
FigureĀ 56 ā€“ Example for a multi-phase circuit
58 FigureĀ 57 ā€“ Overview diagram for a material handling plant
59 FigureĀ 58 ā€“ Overview diagram for one conveyer belt function
FigureĀ 59 ā€“ Overview diagram process plant
60 FigureĀ 60 ā€“ Overview diagram of an electrical plant
61 7.3 Function diagrams
7.3.1 General
7.3.2 Equivalent-circuit diagrams
7.3.3 Logic-function diagram
FigureĀ 61 ā€“ Signal flow in a function diagram
FigureĀ 62 ā€“ Example of an equivalent-circuit diagram
62 7.4 Circuit diagrams
7.4.1 General
7.4.2 Layout
FigureĀ 63 ā€“ Minimized use of logic negations
63 7.4.3 Methods for representation of components
FigureĀ 64 ā€“ Lining-up of symbols
FigureĀ 65 ā€“ Grouping of symbols for functionally related components
64 FigureĀ 66 ā€“ Attached presentation of symbols
65 FigureĀ 67 ā€“ Detached presentation of symbols
66 FigureĀ 68 ā€“ Example of the use of inset tables
67 FigureĀ 69 ā€“ Example of presentation of internal connection
FigureĀ 70 ā€“ Repeated presentation of a symbol for a quadruple multiplexer
68 7.4.4 Representation of components with movable parts
FigureĀ 71 ā€“ Simplified repeated presentation of a symbol for a quadruple multiplexer
69 FigureĀ 72 ā€“ Symbol of a five-position switch supplemented with a graph
FigureĀ 73 ā€“ Examples of pilot switch
FigureĀ 74 ā€“ Symbol of a pilot switch supplemented with a note
70 7.4.5 Representation of supply circuits
FigureĀ 75 ā€“ Orientation of contact symbols
FigureĀ 76 ā€“ Representation of a.c. supply circuits
71 7.4.6 Representation of binary logic elements
FigureĀ 77 ā€“ Representation of d.c. supply circuits
FigureĀ 78 ā€“ Examples of use of logic polarity indication
FigureĀ 79 ā€“ Examples of mismatched polarity indications
72 7.4.7 Symbols with a large number of terminals
7.4.8 Wired functions (wired-AND, wired-OR)
FigureĀ 80 ā€“ Example of a split presentation of a symbol
73 7.5 Connection diagrams
7.5.1 General
Table 1 ā€“ Possible distributed logic connections
74 7.5.2 Representation of devices, units or assemblies
FigureĀ 81 ā€“ Example of a connection diagram
75 7.5.3 Representation of terminals
7.5.4 Representation of cables and its constituent cores
7.5.5 Representation of conductors
FigureĀ 82 ā€“ Example of presentation of termination of a multi-core cable
76 FigureĀ 83 ā€“ Example of cable connections
77 7.5.6 Simplified presentation
FigureĀ 84 ā€“ Example of connection diagram for a sub-rack
78 8 Drawings
8.1 General
8.2 Requirements on base documents
FigureĀ 85 ā€“ Example of simplified presentation of a connection diagram
80 8.3 Arrangement drawings
FigureĀ 86 ā€“ Example of the use of a base document
FigureĀ 87 ā€“ Presentation of technical data
81 FigureĀ 88 ā€“ Examples of the use of symbols for indication mounting methods
82 FigureĀ 89 ā€“ An arrangement drawing the mounting panel of a cubicle
83 9 Tables
9.1 General
9.2 Presentation of reference designations
FigureĀ 90 ā€“ An arrangement drawing of an industrial plant
84 9.3 Connection tables
FigureĀ 91 ā€“ Example setting the common initial portion in the table header
FigureĀ 92 ā€“ Example omitting the common initial portion on successive lines
85 FigureĀ 93 ā€“ Example of a terminal-oriented connection table
FigureĀ 94 ā€“ Example of a connection table with remote end designations
86 10 Charts, graphs
10.1 General
10.2 Function charts
10.3 Sequence charts and time sequence charts
FigureĀ 95 ā€“ Example of a connection-oriented connection table
87 11 Structured documentation
11.1 General
FigureĀ 96 ā€“ Example of a time sequence chart
88 11.2 Presentation of occurrences of an object type in diagrams
11.2.1 General
11.2.2 Using an instance diagram
11.2.3 Using a single symbol
FigureĀ 97 ā€“ Example of an instance diagram of a motor starter
FigureĀ 98 ā€“ A symbol for a motor starter
89 FigureĀ 99 ā€“ Example of a document in table form describing the relations between external terminals of a motor starter to the internal terminals of its components
FigureĀ 100 ā€“ A symbol for the motor starter, for single-line presentations
90 11.3 Referencing
FigureĀ 101 ā€“ Example of a document in table form describing the relations between external terminals of a motor starter to the internal terminals of its components
91 FigureĀ 102 ā€“ Referencing in accordance with IECĀ 62023
92 11.4 Document metadata
12 CAx conformance requirements
FigureĀ 103 ā€“ Direct referencing
94 Annex A (normative) Construction of a symbol for an object which does not have a symbol in IEC 60617
A.1 General rules
A.2 Example ā€“ Miniature circuit-breaker
Figure A.1 ā€“ The general symbols for an object in IECĀ 60617
95 Figure A.2 ā€“ Miniature circuit-breaker shown with the symbol for a circuit-breaker
Figure A.3 ā€“ Miniature circuit-breaker shown with the general symbol for a switch qualified with the symbol for automatic tripping
96 Figure A.4 ā€“ Miniature circuit-breaker shown with the symbol for a circuit-breaker qualified with the symbol for automatic tripping
Figure A.5 ā€“ Miniature circuit-breaker shown with the general symbol for a switch qualified with the symbols for thermal and electromagnetic effects
Figure A.6 ā€“ Miniature circuit-breaker shown with the symbol for a circuit-breaker qualified with the symbol for thermal and electromagnetic effects
97 A.3 Example ā€“ miniature circuit-breaker with an RCD (Residual Current Device)
Figure A.7 ā€“ Symbol for a miniature circuit-breaker with an RCD, version 1
Figure A.8 ā€“ Symbol for a miniature circuit-breaker with an RCD, version 2
98 A.4 Example ā€“ RCD (residual current device) / RCM (residual monitoring device)
Figure A.9 ā€“ Symbol for a miniature circuit-breaker with an RCD, version 3
Figure A.10 ā€“ Example of a symbol for an RCD
Figure A.11 ā€“ Example of a symbol for an RCM
99 A.5 Example ā€“ PLC
Figure A.12 ā€“ Symbols for a PLC
100 Figure A.13 ā€“ A circuit diagram with a symbol of a PLC
101 Annex B (informative) Document management information and title blocks
B.1 Presentation of document management information
Tables
Table B.1 ā€“ Metadata element names
102 B.2 Example of the layout of a title block
Figure B.1 ā€“ Example of the arrangement of information in a title block
Figure B.2 ā€“ Example of a filled-in title block
103 B.3 Examples of the location of identification areas
Figure B.3 ā€“ Examples of locations of identification areas and possible title blocks
104 Annex C (informative) Document kind designations and content of information
105 Table C.1 ā€“ Recommended document kind designations (1 of 2)
107 Table C.2 ā€“ Current document kind designations and replacements (1 of 2)
109 Bibliography
BS EN 61082-1:2015
$215.11