BS EN 61243-1:2005+A1:2010:2011 Edition

$198.66

Live working. Voltage detectors – Capacitive type to be used for voltages exceeding 1 kV a.c.

Published By Publication Date Number of Pages
BSI 2011 62
Guaranteed Safe Checkout
Categories: ,

If you have any questions, feel free to reach out to our online customer service team by clicking on the bottom right corner. We’re here to assist you 24/7.
Email:[email protected]

This part of IEC 61243 is applicable to portable voltage detectors, with or without built-in power sources, to be used on electrical systems for voltages of 1 kV to 765 kV a.c., and frequencies of 50 Hz and/or 60 Hz.

This part applies only to voltage detectors of capacitive type used in contact with the part to be tested, as a complete device including its insulating element or as a separate device, adaptable to an insulating stick which, as a separate tool, is not covered by this standard (see 4.4.1 for general design).

Other types of voltage detectors are not covered by this part of the standard.

Some restrictions on their use are applicable in the case of factory-assembled switchgear and on overhead systems of electrified railways (see Annex B, instructions for use).

NOTE Except where otherwise specified, all the voltages defined in this standard refer to values of phase-to-phase voltages of three-phase systems. In other systems, the applicable phase-to-phase or phase-to-earth (ground) voltages should be used to determine the operating voltage.

PDF Catalog

PDF Pages PDF Title
7 Scope
Normative references
8 Terms and definitions
12 Requirements
General requirements
Safety
Indication
13 Functional requirements
Clear indication
Threshold voltage
Continuous indication
Clear perceptibility
14 Visual indication
Audible indication
Temperature and humidity dependence of the indication
Frequency dependence
Response time
Power source dependability
15 Testing element
Non-response to d.c. voltage
Time rating
Electrical requirements
Insulating material
Protection against bridging
Resistance against sparking
Mechanical requirements
16 Design
General design
Category
Dimensions, construction
17 Grip force and deflection
Vibration resistance
Drop resistance
Shock resistance
Markings
18 Instructions for use
Specific requirements
For insulating element of a voltage detector as a complete d
Dielectric strength
Leakage current
For indicator casing of voltage detector as a separate devic
Tests
General
19 Tests under wet conditions
Type test
20 Routine test
Sampling test
Test methods
Function tests
Clear indication
General
Measurement of threshold voltage
21 Influence of in-phase interference field
23 Influence of interference voltage
Clear perceptibility of visual indication
24 Clear perceptibility of audible indication
25 Frequency dependence
Response time
Power source dependability
26 Check of testing element
Non-response to d.c. voltage
Time rating
27 Dielectric tests
Protection against bridging for indoor/outdoor type voltage
For voltage detector ( 245kV
Surface stress test
28 Radial and surface stress test
For voltage detector > 245 kV
Surface stress test
Radial and surface stress test
29 Protection against bridging for outdoor type voltage detecto
30 Spark resistance
31 Mechanical tests
Visual and dimensional inspection
Visual inspection
Dimensional inspection
Grip force and deflection (only applicable for voltage detec
Vibration resistance
32 Drop resistance
Shock resistance
Climatic dependence
33 Durability of markings
Specific tests
Leakage current for voltage detector as a complete device
34 Leakage current under dry conditions
Leakage current under wet conditions (for outdoor type only)
35 Quality assurance plan and acceptance test
General
Records
BS EN 61243-1:2005+A1:2010