IEC 62442-1:2011 defines a measurement and calculation method of the total input power for controlgear – lamp circuits when operating with their associated fluorescent lamp(s). The calculation method for the efficiency of the lamp controlgear is also defined. This International Standard applies to electrical controlgear lamp circuits consisting only of the controlgear and the lamp(s). It is intended for use on a.c. supplies up to 1 000 V at 50 Hz or 60 Hz.

PDF Catalog

PDF Pages PDF Title
6 English

CONTENTS
7 1 Scope
2 Normative references
8 3 Terms and definitions
10 4 General
4.1 Applicability
4.2 Declaration of ballast lumen factor
4.3 Dimmable controlgear
4.4 Multi-wattage and/or multi-lamp controlgear
4.5 Accuracy of measurement
4.6 Sampling of controlgear for testing
11 4.7 Number of samples
4.8 Conditioning of lamps
4.9 Test voltages and frequencies
5 Method of measurement and calculation of total input power of controlgear –lamp circuits and the efficiency of controlgear
5.1 Correction for ballast lumen factor
5.2 Method of measurement
Table 1 – Typical nominal electricity supply details for some regions
12 5.3 Measurement and calculation of the total input power of magnetic wire wound controlgear – lamp circuits
5.4 Calculation of the efficiency of magnetic wire wound controlgear
5.5 Measurement and calculation of the total input power of electronic controlgear –lamp circuits
14 5.6 Calculation of the efficiency of electronic controlgear
5.7 Measuring the standby power
Figures

Figure 1 – Configuration of lamp and photocell sensor
15 Annex A (normative)
Energy performance measurement setup
Figure A.1 – Measurement of magnetic wire wound controlgear – lamp circuits
16 Figure A.2 – Measurement of a.c. supplied electroniccontrolgear – lamp circuits
Figure A.3 – Test setup for measuring standby power
17 Figure A.4 – Side view of light output measurement system
Figure A.5 – Top view of light output measurement system
19 Annex B (informative)
Application of the reference ballast whenassessing lamps in electronic operation
20 Bibliography