BS EN IEC 60076-22-3:2019
$142.49
Power transformers – Power transformer and reactor fittings. Insulating liquid to air heat exchangers
Published By | Publication Date | Number of Pages |
BSI | 2019 | 28 |
This part of IEC 60076 applies to liquid to air heat exchangers, using forced air and forced liquid circuits, used on liquid immersed power transformers according to IEC 60076-1 and reactors according to IEC 60076-6 with and without conservator for indoor or outdoor installation. It outlines the service conditions and the mechanical and electrical requirements that are common to this equipment.
It also outlines the operation requirements specific to this equipment as well as the preferred dimensions relevant for interchangeability and the type and routine tests to be performed.
PDF Catalog
PDF Pages | PDF Title |
---|---|
2 | undefined |
5 | Annex ZA(normative)Normative references to international publicationswith their corresponding European publications |
7 | English CONTENTS |
9 | FOREWORD |
11 | INTRODUCTION |
12 | 1 Scope 2 Normative references 3 Terms and definitions |
13 | 4 General requirements 4.1 Service conditions 4.2 Degree of protection of electrical components (IP) 4.3 Corrosion protection 4.3.1 External (atmosphere) 4.3.2 Insulating liquid side 4.4 Insulating liquid characteristics |
14 | 5 Design and characteristics 5.1 Main components and characteristics 5.1.1 Headers 5.1.2 Tube sheets 5.1.3 Tube bundle 5.1.4 Turbulators 5.1.5 Passes 5.1.6 Standard design and cooling arrangement 5.2 General characteristics 5.2.1 Rating plate information |
15 | 5.2.2 Rated cooling capacity 5.2.3 Information to be provided with enquiry and order |
16 | 5.2.4 Mechanical design |
17 | 5.2.5 Preparation for transport and storage Table 1 – Mandatory fittings |
18 | 6 Tests 6.1 General requirements for tests 6.1.1 General 6.1.2 List of tests 6.2 Routine tests 6.2.1 Tightness tests |
19 | 6.2.2 Visual inspection 6.2.3 Functional test 6.2.4 Cleanliness 6.2.5 External painting 6.3 Type tests – Rated values test |
20 | Annex A (informative)Design details of heat exchangers A.1 Dimensions and designs A.1.1 General A.1.2 Schematic design of cooling unit (without oil pump) Figures Figure A.1 – Schematic design of cooling unit (without oil pump) |
21 | A.1.3 Versions of flange arrangement Figure A.2 – Versions of flange arrangement |
22 | A.2 Constructional materials – Common selection of materials |
23 | Annex B (informative)Performance of heat exchangers B.1 General B.2 Performance of heat exchangers Figure B.1 – General diagram for cooling temperatures |
24 | B.3 Variation of cooling capacity as function of average oil temperature rise Figure B.2 – Variation of cooling capacity as function of average oil temperature rise |
25 | B.4 Variation of cooling capacity for modified flow quantities B.4.1 Variation of cooling capacity as function of air flow quantity Figure B.3 – Variation of cooling capacity as function of air flow quantity |
26 | B.4.2 Variation of cooling capacity as function of oil flow quantity Figure B.4 – Variation of cooling capacity as function of oil flow quantity |
27 | Bibliography |