BS EN IEC 60794-3-40:2022
$167.15
Optical fibre cables – Outdoor cables. Family specification for cables for storm and sanitary sewers
Published By | Publication Date | Number of Pages |
BSI | 2022 | 38 |
This part of IEC 60794 is a family specification that covers sewer cables and conduits for installation by blowing and/ or pulling in man accessible and non-man accessible storm and sanitary sewers. Systems built with components covered by this standard are subject to the requirements of sectional specification IEC 60794-3. Sewer cable and conduit constructions have to meet the different requirements of the sewer operating companies and/or associations regarding chemical, environmental, operational, cleaning and in general maintenance conditions. Preferential applications, describing sewer cable characteristics versus methods of installation is reported in Annex A and Annex B for non-man accessible sewers. Clause 5 describes characteristics of sewer cables and conduits for installation by blowing, pulling or other means in storm and sanitary sewers. Detail specifications may be prepared on the basis of this family specification. The parameters specified in this standard may be affected by measurement uncertainty arising either from measurement errors or calibration errors due to lack of suitable standards. Acceptance criteria should be interpreted with respect to this consideration. The number of fibres tested is representative of the sewer cable and should be agreed between the customer and the supplier.
PDF Catalog
PDF Pages | PDF Title |
---|---|
2 | undefined |
5 | Annex ZA (normative)Normative references to international publicationswith their corresponding European publications |
7 | English CONTENTS |
9 | FOREWORD |
11 | 1 Scope 2 Normative references |
12 | 3 Terms, definitions, symbols and abbreviated terms 4 General requirements 4.1 Optical fibres 4.2 Cable element 4.3 Optical fibre cable and conduit construction 4.3.1 General |
13 | 4.3.2 Conduits 4.3.3 Sewer cables 4.3.4 Rodent protection 5 Details of family requirements and test conditions for optical fibre cable and conduit 5.1 Cable for installation within conduits (previously fixed to the sewer wall) 5.2 Cable for direct installation into the sewer duct 5.3 Conduit construction |
14 | 5.4 Operating conditions 5.5 Mechanical and environmental tests 5.5.1 Conduits Tables Table 1 – Conduit tests applicable |
17 | 5.5.2 Cable for installation within conduits (previously fixed to the sewer wall) |
18 | Table 2 – Optical fibre cable – Tests applicable |
22 | 5.5.3 Cables for direct installation into the sewer duct |
23 | Table 3 – Tests applicable |
29 | Annex A (informative)Blank detail specification – Sewer cables description A.1 Conduit description Table A.1 – Conduit description |
30 | A.2 Cable for installation within conduits (previously fixed to the sewer wall) Table A.2 – Sewer optical fibre cable description – Within conduits |
31 | A.3 Cables for direct installation into the sewer duct Table A.3 – Sewer optical fibre cable description – Direct installation |
32 | Annex B (informative)Cables for non-man accessible sewers Table B.1 – Characteristics for optical fibre cables within non-man accessible sewers |
33 | Annex C (informative)Examples of conduits and sewer cables C.1 Loose tube cables for installation within conduits C.1.1 Dielectric sewer cables C.1.2 Sewer cable installed within a conduit Figures Figure C.1 – Dielectric optical fibre sewer cable Figure C.2 – Dielectric optical fibre sewer cable |
34 | C.2 Loose tube cables for direct installation into the sewer duct C.2.1 Cables to be screwed to the sewer inner wall Figure C.3 – Optical fibre sewer cable within a conduit Figure C.4 – Optical fibre sewer cable for direct installation –Peripheral strength members |
35 | C.2.2 Cables for spanning between manholes, similarly to aerial cables Figure C.5 – Optical fibre sewer cable for direct installation –Steel wire armouring Figure C.6 – Optical fibre sewer cable for spanning –Peripheral strength members Figure C.7 – Optical fibre sewer cable for spanning –Steel wire armouring |
36 | C.2.3 Cables for laying on the ground of the sewer Figure C.8 – Optical fibre sewer cable for laying – Aluminium tape Figure C.9 – Optical fibre sewer cable for laying – Corrugated steel Figure C.10 – Optical fibre sewer cable for laying – 2-layer-steel wire armouring |
37 | Bibliography |