BSI 23/30435543 DC 2023
$24.66
BS EN IEC 63380-1. Local Charging station management systems and Local Energy Management Systems network connectivity and information exchange – Part 1. General Requirements, Use Cases and abstract Messages
Published By | Publication Date | Number of Pages |
BSI | 2023 | 166 |
PDF Catalog
PDF Pages | PDF Title |
---|---|
16 | FOREWORD |
18 | INTRODUCTION |
19 | 1 Scope 2 Normative references |
20 | 3 Terms, definitions, and abbreviated terms 3.1 Terms and definitions |
21 | 3.2 Abbreviated terms 4 Scenarios and User Stories 4.1 Introduction |
22 | 4.2 User Stories |
24 | 4.3 Stakeholders 4.4 Use Case Actors 4.4.1 Charging Station 4.4.2 Energy Management System (EMS) |
25 | 4.4.3 Electric Vehicle (EV) |
26 | 4.5 Mapping of User Stories to Use Cases 5 Technical Use Cases 5.1 Reader’s guide 5.1.1 General 5.1.2 Requirements wording |
27 | 5.1.3 Reading the graphics 5.2 Charging Station Commissioning and Configuration 5.2.1 Introduction 5.2.2 Scenario Overview |
28 | 5.2.3 Scenario Support Requirements 5.2.4 Scenario flow 5.2.5 Scenario Details 5.2.5.1 Scenario 1 – Charging station sends manufacturer information 5.2.5.1.1 Description 5.2.5.1.2 Conditions |
29 | 5.2.5.2 Scenario 2 – Charging station sends error state 5.2.5.2.1 Description 5.2.5.2.2 Conditions 5.2.6 Scenarios and Use Case Functions |
30 | 5.2.7 Dependencies to other Use Cases 5.2.8 Additional Information 5.3 Coordinated EV Charging 5.3.1 Introduction |
32 | 5.3.2 Scenario Overview 5.3.3 Scenario support requirements |
34 | 5.3.4 Scenario flow |
35 | 5.3.5 Scenario details 5.3.5.1 Scenario 1 – EV via charging station sends charging energy demand to EMS 5.3.5.1.1 Description 5.3.5.1.2 Conditions |
36 | 5.3.5.2 Scenario 2 – EMS sends maximum power limitation curve to EV 5.3.5.2.1 Description |
37 | 5.3.5.2.2 Conditions 5.3.5.3 Scenario 3 – EMS sends incentive table to EV 5.3.5.3.1 Description |
39 | 5.3.5.3.2 Conditions |
40 | 5.3.5.4 Scenario 4 – EV via charging station sends charging plan curve to EMS 5.3.5.4.1 Description 5.3.5.4.2 Conditions |
41 | 5.3.5.5 Scenario 5 – EMS with the role of overload protection send heartbeat 5.3.5.5.1 Description 5.3.5.5.2 Conditions 5.3.5.6 Scenario 6 – EMS with the role of delivering incentives send heartbeat 5.3.5.6.1 Description |
42 | 5.3.5.6.2 Conditions 5.3.5.7 Scenario 7 – EMS with the role of overload protection sends error state 5.3.5.7.1 Description 5.3.5.7.2 Conditions 5.3.5.8 Scenario 8 – EMS with the role of delivering incentives sends error state 5.3.5.8.1 Description 5.3.5.8.2 Conditions |
43 | 5.3.6 Scenarios and Use Case Functions 5.3.7 Dependencies to other Use Cases 5.3.7.1 “EV Commissioning and Configuration” 5.3.7.1.1 “Scenario 1 – EV connected” 5.3.7.1.2 “Scenario 6 – EV via charging station sends charging power limits” 5.3.7.1.3 “Scenario 7 – EV sleep mode” |
44 | 5.3.7.1.4 “Scenario 8 – EV disconnected” 5.3.7.2 “EV Charging Electricity Measurement” 5.3.7.3 “Overload Protection by EV Charging Current Curtailment” 5.3.8 Additional Information 5.4 EV Charging Electricity Measurement 5.4.1 Introduction |
45 | 5.4.2 Scenario Overview 5.4.3 Scenario Support Requirements 5.4.4 Scenario flow 5.4.5 Scenario Details 5.4.5.1 Scenario 1 – Measure EV charging current 5.4.5.1.1 Description |
46 | 5.4.5.1.2 Conditions 5.4.5.2 Scenario 2 – Measure EV charging power 5.4.5.2.1 Description 5.4.5.2.2 Conditions |
47 | 5.4.5.3 Scenario 3 – Measure EV charged energy 5.4.5.3.1 Description 5.4.5.3.2 Conditions 5.4.6 Scenarios and Use Case Functions 5.4.7 Dependencies to other Use Cases 5.4.7.1 “EV Commissioning and Configuration” 5.4.7.1.1 “Scenario 1 – EV connected” |
48 | 5.4.7.1.2 “Scenario 3 – EV via charging station sends support of asymmetric charging” 5.4.8 Additional Information 5.5 EV Charging Summary 5.5.1 Introduction 5.5.2 Scenario Overview 5.5.3 Scenario Support Requirements |
49 | 5.5.4 Scenario flow 5.5.5 Scenario Details 5.5.5.1 Scenario 1 – EMS sends Charging Session Summary to charging station 5.5.5.1.1 Description 5.5.5.1.2 Conditions |
50 | 5.5.6 Scenarios and Use Case Functions 5.5.7 Dependencies to other Use Cases 5.5.7.1 “EV Commissioning and Configuration” 5.5.7.1.1 “Scenario 1 – EV connected” 5.5.7.1.2 “Scenario 8 – EV disconnected” 5.5.7.2 “Measurement of Electricity During EV Charging” 5.5.8 Additional Information 5.6 EV Commissioning and Configuration 5.6.1 Introduction |
51 | 5.6.2 Scenario Overview 5.6.3 Scenario Support Requirements |
52 | 5.6.4 Scenario flow 5.6.5 Scenario Details 5.6.5.1 Scenario 1 – EV connected 5.6.5.1.1 Description 5.6.5.1.2 Conditions |
53 | 5.6.5.2 Scenario 2 – EV via charging station sends communication standard 5.6.5.2.1 Description 5.6.5.2.2 Conditions 5.6.5.3 Scenario 3 – EV via charging station sends support of asymmetric charging 5.6.5.3.1 Description |
54 | 5.6.5.3.2 Conditions 5.6.5.4 Scenario 4 – EV via charging station sends identification 5.6.5.4.1 Description 5.6.5.4.2 Conditions |
55 | 5.6.5.5 Scenario 5 – EV via charging station sends manufacturer information 5.6.5.5.1 Description 5.6.5.5.2 Conditions |
56 | 5.6.5.6 Scenario 6 – EV via charging station sends charging power limits 5.6.5.6.1 Description 5.6.5.6.2 Conditions 5.6.5.7 Scenario 7 – EV sleep mode 5.6.5.7.1 Description 5.6.5.7.2 Conditions |
57 | 5.6.5.8 Scenario 8 – EV disconnected 5.6.5.8.1 Description 5.6.5.8.2 Conditions 5.6.6 Scenarios and Use Case Functions |
58 | 5.6.7 Dependencies to other Use Cases 5.6.8 Additional Information 5.7 EV State of Charge 5.7.1 Introduction 5.7.2 Scenario Overview 5.7.3 Scenario Support Requirements |
59 | 5.7.4 Scenario flow 5.7.5 Scenario Details 5.7.5.1 Scenario 1 – Monitor EV’s state of charge 5.7.5.1.1 Description 5.7.5.1.2 Conditions 5.7.6 Scenarios and Use Case Functions 5.7.7 Dependencies to other Use Cases 5.7.8 Additional Information 5.8 Limitation of Active Power Consumption 5.8.1 Introduction |
60 | 5.8.2 Detailed background information and rules |
61 | 5.8.2.1 Charging station power limitation 5.8.2.2 Initial state |
62 | 5.8.2.3 unlimited/controlled state 5.8.2.4 Limited state |
63 | 5.8.2.5 Failsafe state |
64 | 5.8.3 State machine 5.8.3.1 Defined states |
65 | 5.8.3.2 Possible transitions |
66 | 5.8.4 Scenario Overview 5.8.5 Scenario Support Requirements 5.8.6 Scenario flow 5.8.7 Scenario Details 5.8.7.1 Scenario 1 – Control active power consumption 5.8.7.1.1 Description |
67 | 5.8.7.1.2 Conditions 5.8.7.2 Scenario 2 – Failsafe values 5.8.7.2.1 Description |
68 | 5.8.7.2.2 Conditions |
69 | 5.8.7.3 Scenario 3 – Heartbeat 5.8.7.3.1 Description 5.8.7.3.2 Conditions 5.8.7.4 Scenario 4 – Constraints 5.8.7.4.1 Description |
70 | 5.8.7.4.2 Conditions 5.8.8 Scenarios and Use Case Functions 5.8.9 Dependencies to other Use Cases 5.8.9.1 Monitoring of Active Power Consumption |
71 | 5.8.10 Further information and rules 5.8.10.1 Sign conventions 5.8.11 Additional Information 5.9 Monitoring of Active Power Consumption 5.9.1 Introduction |
72 | 5.9.2 Scenario Overview 5.9.3 Scenario Support Requirements |
73 | 5.9.4 Scenario flow 5.9.5 Scenario Details 5.9.5.1 Scenario 1 – Monitor power 5.9.5.1.1 Description 5.9.5.1.2 Conditions 5.9.5.2 Scenario 2 – Monitor energy 5.9.5.2.1.1 Description |
74 | 5.9.5.2.1.2 Conditions 5.9.5.3 Scenario 3 – Monitor current 5.9.5.3.1 Description 5.9.5.3.2 Conditions |
75 | 5.9.5.4 Scenario 4 – Monitor voltage 5.9.5.4.1 Description 5.9.5.4.2 Conditions 5.9.5.5 Scenario 5 – Monitor frequency 5.9.5.5.1 Description |
76 | 5.9.5.5.2 Conditions 5.9.6 Scenarios and Use Case Functions 5.9.7 Dependencies to other Use Cases 5.9.8 Additional Information 5.10 Optimization of Self-Consumption during EV Charging 5.10.1 Introduction |
77 | 5.10.2 Scenario Overview 5.10.3 Scenario Support Requirements 5.10.4 Scenario flow 5.10.5 Scenario Details 5.10.5.1 Scenario 1 – EMS informs EV about self-produced current 5.10.5.1.1 Description |
78 | 5.10.5.1.2 Conditions 5.10.5.2 Scenario 2 – EV checks EMS availability 5.10.5.2.1 Description |
79 | 5.10.5.2.2 Conditions 5.10.5.3 Scenario 3 – EMS sends error state 5.10.5.3.1 Description 5.10.5.3.2 Conditions 5.10.6 Dependencies to other Use Cases 5.10.6.1 “Charging Station Commissioning and Configuration” 5.10.6.1.1 “Scenario 2 – Charging station sends error state” |
80 | 5.10.6.2 “EV Charging Electricity Measurement” 5.10.6.3 “EV Commissioning and Configuration” 5.10.6.3.1 “Scenario 1 – EV connected” 5.10.6.3.2 “Scenario 6 – EV via charging station sends charging power limits” 5.10.6.3.3 “Scenario 8 – EV disconnected” 5.10.7 Additional Information 5.11 Overload Protection by EV Charging Current Curtailment 5.11.1 Introduction |
81 | 5.11.2 Derivation of the time limits for the involved units: 5.11.3 Further Information: |
82 | 5.11.4 Scenario Overview 5.11.5 Scenario Support Requirements 5.11.6 Scenario flow 5.11.7 Scenario Details 5.11.7.1 Scenario 1 – EMS curtails charging current of EV 5.11.7.1.1 Description |
83 | 5.11.7.1.2 Conditions |
84 | 5.11.7.2 Scenario 2 – EV via charging station checks EMS availability 5.11.7.2.1 Description 5.11.7.2.2 Conditions 5.11.7.3 Scenario 3 – EMS sends error state 5.11.7.3.1 Description 5.11.7.3.2 Conditions |
85 | 5.11.8 Scenarios and Use Case Functions 5.11.9 Dependencies to other Use Cases 5.11.9.1 “Charging Station Commissioning and Configuration” 5.11.9.1.1 “Scenario 2 – Charging station sends error state” 5.11.9.2 “EV Charging Electricity Measurement” 5.11.9.3 “EV Commissioning and Configuration” 5.11.9.3.1 “Scenario 1 – EV connected” 5.11.9.3.2 “Scenario 6 – EV via charging station sends charging power limits” |
86 | 5.11.9.3.3 “Scenario 8 – EV disconnected” 5.11.10 Additional Information 5.12 Basic EV Charging/Discharging 5.12.1 Introduction 5.12.2 Scenario Overview |
87 | 5.12.3 Scenario Support Requirements 5.12.4 Scenario flow 5.12.5 Scenario Details 5.12.5.1 Scenario 1 – EMS checks charge/discharge availability status 5.12.5.1.1 Description |
88 | 5.12.5.1.2 Conditions 5.12.5.2 Scenario 2 – EMS monitors EV’s state of charge 5.12.5.2.1 Description 5.12.5.2.2 Conditions |
89 | 5.12.5.3 Scenario 3 – EMS starts charging/discharging 5.12.5.3.1 Description 5.12.5.3.2 Conditions 5.12.5.4 Scenario 4 – EMS controls charging/discharging 5.12.5.4.1 Description 5.12.5.4.2 Conditions |
90 | 5.12.5.5 Scenario 5 – EV charging/discharging completed 5.12.5.5.1 Description 5.12.5.5.2 Conditions 5.12.6 Scenarios and Use Case Functions |
91 | 5.12.7 Dependencies to other Use Cases 5.12.7.1 “EV Commissioning and Configuration” 5.12.7.1.1 “Scenario 1 – EV connected” 5.12.7.1.2 “Scenario 6 – EV via charging station sends charging power limits” 5.12.7.1.3 “Scenario 8 – EV disconnected” 5.12.8 Additional Information 5.13 Dynamic Bidirectional EV Charging 5.13.1 Introduction |
92 | 5.13.2 Dynamic mode |
93 | 5.13.3 Scenario Overview 5.13.4 Scenario Support Requirements 5.13.5 Scenario flow |
94 | 5.13.6 Scenarios and Use Case Functions 5.13.6.1 Scenario 1 – Control active power setpoint 5.13.6.1.1 Description |
95 | 5.13.6.1.2 Conditions 5.13.6.2 Scenario 2 – Monitor energy requests 5.13.6.2.1 Description |
97 | 5.13.6.2.2 Conditions 5.13.6.3 Scenario 3 – Monitor constraints 5.13.6.3.1 Description 5.13.6.3.2 Conditions |
98 | 5.13.6.4 Scenario 4 – Configuration parameters 5.13.6.4.1 Description 5.13.6.4.2 Conditions 5.13.7 Scenarios and Use Case Functions 5.13.8 Dependencies to other Use Cases 5.13.8.1 “Monitoring of Power Consumption” |
99 | 5.13.8.2 “Limitation of Power Consumption” 5.13.9 Further information and rules 5.13.9.1 Sign conventions 5.13.10 Additional Information 6 Generic Use Case Functions (UCF) 6.1 Concepts |
100 | 6.2 UCF_AC_Measurement 6.2.1 Generic Description |
101 | 6.2.1.1 Measurement 6.2.1.1.1 Measurement: Power 6.2.1.1.1.1 Measurement Description |
102 | 6.2.1.1.1.2 Measurement Constraints 6.2.1.1.1.3 Measurement Data |
103 | 6.2.1.1.2 Measurement: Energy 6.2.1.1.2.1 Measurement Description 6.2.1.1.2.2 Measurement Constraints |
104 | 6.2.1.1.2.3 Measurement Data |
105 | 6.2.1.1.3 Measurement: Current 6.2.1.1.3.1 Measurement Description 6.2.1.1.3.2 Measurement Constraints 6.2.1.1.3.3 Measurement Data |
106 | 6.2.1.1.4 Measurement: Voltage 6.2.1.1.4.1 Measurement Description 6.2.1.1.4.2 Measurement Constraints 6.2.1.1.4.3 Measurement Data |
107 | 6.2.1.1.5 Measurement: Frequency 6.2.1.1.5.1 Measurement Description 6.2.1.1.5.2 Measurement Constraints |
108 | 6.2.1.1.5.3 Measurement Data 6.2.1.2 Electrical Connection Data 6.2.1.2.1 Electrical Connection: Power 6.2.1.2.1.1 Electrical Connection Description 6.2.1.2.1.2 Electrical Connection Parameters |
110 | 6.2.1.2.2 Electrical Connection: Energy 6.2.1.2.2.1 Electrical Connection Description 6.2.1.2.2.2 Electrical Connection Parameters |
111 | 6.2.1.2.3 Electrical Connection: Current 6.2.1.2.3.1 Electrical Connection Description 6.2.1.2.3.2 Electrical Connection Parameters |
112 | 6.2.1.2.4 Electrical Connection: Voltage 6.2.1.2.4.1 Electrical Connection Description 6.2.1.2.4.2 Electrical Connection Parameters |
113 | 6.2.1.2.5 Electrical Connection: Frequency 6.2.1.2.5.1 Electrical Connection Description 6.2.1.2.5.2 Electrical Connection Parameters 6.2.2 Additional Information 6.3 UCF_Characteristics 6.3.1 Generic Description |
114 | 6.3.1.1 Characteristics |
115 | 6.3.1.2 Additional Information 6.4 UCF_Charging_Power_Limits 6.4.1 Generic Description |
116 | 6.4.1.1 Electrical Connection Parameters 6.4.1.2 Electrical Connection Permitted Values 6.4.2 Additional Information 6.5 UCF_Consumption_Curve 6.5.1 Generic Description |
117 | 6.5.1.1 Consumption Curve |
118 | 6.5.1.1.1 Time Series Description |
119 | 6.5.1.1.2 Time Series Constraints (Recommended) 6.5.1.1.3 Time Series Data |
123 | 6.5.2 Additional Information 6.6 UCF_Device_Configuration 6.6.1 Generic Description |
124 | 6.6.1.1 Device Configuration 6.6.1.1.1 Key Value Description 6.6.1.2 Device Configuration Data |
125 | 6.6.1.3 Write Device Configuration Data 6.6.1.3.1 Key Value Data |
126 | 6.6.2 Additional information 6.7 UCF_Device_State 6.7.1 Generic Description |
127 | 6.7.1.1 Device State |
128 | 6.7.2 Additional Information 6.8 UCF_EV_Connected 6.8.1 Generic Description 6.8.1.1 Information Content 6.8.2 Additional Information 6.9 UCF_Heartbeat 6.9.1 Generic Description |
129 | 6.9.1.1 Heartbeat 6.9.2 Additional Information |
130 | 6.10 UCF_Identification 6.10.1 Generic Description 6.10.1.1 Identification |
131 | 6.10.2 Additional Information 6.11 UCF_Incentive_Table 6.11.1 Generic Description |
132 | 6.11.1.1 Incentive Table 6.11.1.1.1 Incentive Table Description |
135 | 6.11.1.1.2 Incentive Table Constraints |
136 | 6.11.1.1.3 Incentive Table Data |
138 | 6.11.1.2 Write Incentive Table 6.11.1.2.1 Incentive Table Description |
141 | 6.11.1.2.2 Incentive Table Data |
143 | 6.11.2 Additional Information 6.12 UCF_Load_Control 6.12.1 Generic Description |
144 | 6.12.1.1 Load Constraints 6.12.1.1.1 Load Control Limit Description |
145 | 6.12.1.1.2 Load Limit Data 6.12.1.1.3 Electrical Connection Description 6.12.1.1.4 Electrical Connection Permitted Values |
146 | 6.12.1.2 Load Control 6.12.1.2.1 Write Load Limit Data 6.12.2 Additional Information |
147 | 6.13 UCF_Manufacturer_Information 6.13.1 Generic Description |
148 | 6.13.1.1 Manufacturer Data 6.13.2 Additional Information 6.14 UCF_Maximum_Power_Limitation_Curve 6.14.1 Generic Description |
149 | 6.14.1.1 Maximum Power Limitation Curve |
150 | 6.14.1.1.1 Time Series Description 6.14.1.1.2 Time Series Constraints |
151 | 6.14.1.1.3 Time Series Data |
152 | 6.14.1.2 Update Maximum Power Limitation Curve 6.14.1.2.1 Time Series Data 6.14.2 Additional Information 6.15 UCF_Measurement 6.15.1 Generic Description |
153 | 6.15.1.1 Measurement 6.15.1.1.1 Measurement Description |
154 | 6.15.1.1.2 Measurement Constraints 6.15.1.1.3 Measurement Data 6.15.2 Additional Information 6.16 UCF_Power_Limit 6.16.1 Generic Description |
155 | 6.16.1.1 Current Active Power Limit 6.16.1.1.1 Active Power Limit Description |
156 | 6.16.1.1.2 Active Power Limit Data |
157 | 6.16.1.2 Send Active Power Limit 6.16.1.2.1 Active Power Limit Data 6.16.2 Additional Information 6.17 UCF_Operation_Mode 6.17.1 Generic Description |
158 | 6.17.1.1 Current Operation Mode 6.17.1.1.1 Operation Mode Description 6.17.1.2 Send Operation Mode 6.17.1.2.1 Operation Mode Description |
159 | 6.17.2 Additional information 6.18 UCF_Session_Summary 6.18.1 Generic Description |
160 | 6.18.1.1 Session Summary 6.18.1.1.1 Session Summary Description |
161 | 6.18.1.1.2 Charging Summary Constraints 6.18.1.2 Session Summary Write 6.18.1.2.1 Charging Summary Data |
163 | 6.18.2 Additional Information 6.19 UCF_Setpoint 6.19.1 Generic Description |
164 | 6.19.1.1 Setpoint 6.19.1.1.1 Setpoint Description 6.19.1.1.2 Setpoint Constraints 6.19.1.1.3 Setpoint Data |
165 | 6.19.2 Additional information |
166 | Bibliography |