BSI 23/30476551 DC:2023 Edition
$24.66
BS EN IEC 63510-1. Household appliances network and grid connectivity – Part 1. General requirements, generic data modelling and neutral messages (fast track)
Published By | Publication Date | Number of Pages |
BSI | 2023 | 164 |
PDF Catalog
PDF Pages | PDF Title |
---|---|
7 | European foreword (to be replaced with IEC IS foreword) |
8 | Introduction |
9 | 1 Scope 2 Normative references 3 Terms and definitions |
13 | 4 Process and requirements to enable interoperability 4.1 Introduction 4.2 Process |
14 | Figure 1 — SGAM Framework (from [9]) Figure 2 — Process used in this document |
15 | 4.3 Architecture Figure 3 — Application of EN 50631 series for the local and IoT/Cloud based operating modes |
16 | Figure 4 — Applicability of resources to different scenarios Figure 5 — Applicability of EN 50631 |
17 | Figure 6 — Planned application of EN 50631 using SPINE and SHIP 5 Reader’s guide 5.1 Finding the right information 5.2 Reading the tables |
18 | Table 1 — Presence indication description 5.3 Reading the graphics 5.3.1 Flowcharts Table 2 — Explanation of symbols used in flowcharts 5.3.2 Sequence diagram Figure 7 — Example communication sequence diagram |
19 | 6 User Stories 6.1 Introduction Figure 8 — The different layers of operation classes 6.2 User stories 6.2.1 General 6.2.1.1 Epic 0 6.2.2 Appliance Energy Flexibility 6.2.2.1 General 6.2.2.2 Epic 1 |
20 | 6.2.2.3 Epic 2 6.2.2.3.1 General 6.2.2.3.2 Story 2.1 6.2.2.3.3 Story 2.2 6.2.2.3.4 Story 2.3 6.2.2.3.5 Story 2.4 6.2.2.4 Epic 3 6.2.2.4.1 General 6.2.2.4.2 Story 3.1 6.2.2.4.3 Story 3.2 6.2.2.4.4 Story 3.3 6.2.2.4.5 Story 3.4 6.2.2.4.6 Story 3.5 |
21 | 6.2.2.5 Epic 4 6.2.2.5.1 General 6.2.2.5.2 Story 4.1 6.2.2.5.3 Story 4.2 6.2.2.6 Epic 5 6.2.2.6.1 General 6.2.2.6.2 Story 5.1 6.2.2.6.3 Story 5.2 6.2.2.6.4 Story 5.3 6.2.2.7 Epic 6 6.2.2.7.1 General 6.2.2.7.2 Story 6.1 6.2.2.7.3 Story 6.2 |
22 | 6.2.3 Remote Control of a Smart Appliance 6.2.3.1 General 6.2.3.2 Epic 7 6.2.3.2.1 General 6.2.3.2.2 Story 7.1 6.2.3.2.3 Story 7.2 6.2.3.2.4 Story 7.3 6.2.4 Remote Monitoring of a Smart Appliance 6.2.4.1 General |
23 | 6.2.4.2 Epic 8 6.2.4.2.1 General 6.2.4.2.2 Story 8.1 6.2.4.2.3 Story 8.2 6.2.4.2.4 Story 8.3 6.2.4.2.5 Story 8.4 6.2.4.2.6 Story 8.5 6.2.5 Manual Operation of a Smart Appliance 6.2.5.1 General 6.2.5.2 Story 9.0 7 Use cases 7.1 Introduction |
24 | 7.2 User Stories and Use Cases Table 3 — Mapping of User Stories, Use Cases, and Use Case Functions |
25 | 7.3 Flexible Start for White Goods 7.3.1 General Figure 9 — Energy management with smart appliance and CCM User Story as an example Power sequence, basic properties Figure 10 — Power sequence: P(t) (power-over-time) modelling with slots and time constraints |
26 | Figure 11 — Further possible properties of a scheduled power sequence Schedule phases and states |
27 | 7.3.2 Actors 7.3.2.1 General 7.3.2.2 CCM |
28 | 7.3.2.3 Smart Appliance 7.3.3 Scenario overview Figure 12 — Scenario overview for Flexible Start for White Goods 7.3.4 Scenario support requirements |
29 | Table 4 — Flexible Start for White Goods scenario implementation requirements for Actors 7.3.5 Scenario flow |
30 | Figure 13 — Workflow of this Use Case |
31 | 7.3.6 Scenario details 7.3.6.1 Scenario 1 – Announcement of plan 7.3.6.1.1 Description 7.3.6.1.2 Conditions 7.3.6.2 Scenario 2 – Shift preferred power sequence 7.3.6.2.1 Description 7.3.6.2.2 Conditions 7.3.6.3 Scenario 3 – Select alternative power sequence 7.3.6.3.1 Description |
32 | 7.3.6.3.2 Conditions 7.3.6.4 Scenario 4 – Configure current power sequence 7.3.6.4.1 Description 7.3.6.4.2 Conditions |
33 | 7.3.7 Scenarios and Use Case Functions (UCFs) Table 5 — Flexible Start for White Goods: Scenarios and primary Use Case Functions (UCFs) 7.3.8 Dependencies to other Use Cases 7.3.9 Assumptions and Prerequisites 7.4 Incentive Table-based Power Consumption Management 7.4.1 Actors 7.4.1.1 General 7.4.1.2 Energy Consumer 7.4.1.3 CCM 7.4.2 Scenario Overview |
34 | Figure 14 — Scenario Overview 7.4.3 Scenario support requirements Table 6 — Scenario implementation requirements for Actors 7.4.4 Scenario Flow |
35 | Figure 15 — Workflow of this Use Case 7.4.5 Scenario Details 7.4.5.1 Scenario 1 – Announcement of negotiation options 7.4.5.1.1 Description Table 7 — Scenario 1 – Negotiation options |
36 | 7.4.5.1.2 Conditions 7.4.5.2 Scenario 2 – Negotiation of Committed Data 7.4.5.2.1 Description 7.4.5.2.1.1 General |
37 | Figure 16 — Overview of Scenario 2 activity 7.4.5.2.1.2 Activity begin ① |
38 | Figure 17 — Activity begin diagram of Scenario 2 7.4.5.2.1.3 Activity branch “Update of Committed Power Plan” ② |
39 | Figure 18 — Activity branch “Update of Committed Power Plan” diagram of Scenario 2 7.4.5.2.1.4 Activity branch “Autonomous operation” ③ |
40 | Figure 19 — Activity branch “Autonomous operation” diagram of Scenario 2 7.4.5.2.2 Conditions |
41 | 7.4.5.3 Scenario 3 – Negotiation of Preliminary Data 7.4.5.3.1 Description 7.4.5.3.1.1 General Figure 20 — Overview of Scenario 3 activity 7.4.5.3.1.2 Activity begin ① |
42 | Figure 21 — Activity begin diagram of Scenario 3 7.4.5.3.1.3 Activity branch “Update of Preliminary Power Plan” ② |
43 | Figure 22 — Activity branch “Update of Preliminary Power Plan” diagram of Scenario 3 |
44 | 7.4.5.3.1.4 Activity branch “Disable simulation phase” ③ Figure 23 — Activity branch “Disable simulation phase” diagram of Scenario 3 7.4.5.3.1.5 Abortion of simulation phase 7.4.5.3.2 Conditions |
45 | 7.4.5.4 Scenario 4 – Unsolicited Update of Committed Incentive Table 7.4.5.4.1 Description 7.4.5.4.2 Conditions 7.4.5.5 Scenario 5 – Unsolicited Update of Committed Power Plan 7.4.5.5.1 Description 7.4.5.5.2 Conditions |
46 | 7.4.6 Scenarios and Use Case Functions (UCFs) Table 8 — Scenarios and primary Use Case Functions (UCFs) 7.4.7 Dependencies to other Use Cases 7.4.7.1 “Monitoring of Power Consumption” 7.4.8 Assumptions and Prerequisites 7.5 Install/Remove Device 7.5.1 General 7.5.2 Actors 7.5.2.1 General |
47 | 7.5.2.2 CCM 7.5.2.3 Device 7.5.2.4 User 7.5.3 Scenario Overview Figure 24 — Install/Remove Device Scenario overview 7.5.4 Scenario support requirements Table 9 — Install/Remove Device Scenario implementation requirements for Actors 7.5.5 Scenario Flow |
48 | Figure 25 — Scenario Flow for Install/Remove Device 7.5.6 Scenario details 7.5.6.1 Scenario 1 – Install Smart Appliance – Registration process 7.5.6.1.1 Description 7.5.6.1.2 Conditions 7.5.6.2 Scenario 2 – Remove Smart Appliance 7.5.6.2.1 Description 7.5.6.2.2 Conditions 7.5.7 Scenarios and Use Case Functions (UCFs) |
49 | Table 10 — Scenarios and primary Use Case Functions (UCFs) 7.5.8 Dependencies to other Use Cases 7.5.9 Assumptions and Prerequisites 7.6 Limitation of Power Consumption 7.6.1 General |
50 | Figure 26 — High-Level Use Case functionality overview Table 11 — Controllable System power limitation behaviour |
51 | 7.6.2 Actors 7.6.2.1 General 7.6.2.2 CCM 7.6.2.3 Controllable System 7.6.3 Scenario Overview Figure 27 — Scenario Overview for Limitation of Power Consumption 7.6.4 Scenario support requirements |
52 | Table 12 — Limitation of Power Consumption Scenario implementation requirements for Actors 7.6.5 Scenario Flow 7.6.6 Scenario details 7.6.6.1 Scenario 1 – Control active power limit 7.6.6.1.1 Description Table 13 — Scenario 1 – Control active power limit – Data point list 7.6.6.1.2 Conditions |
53 | 7.6.6.2 Scenario 2 – Failsafe values 7.6.6.2.1 Description Table 14 — Scenario 2 – Failsafe values – Data point list 7.6.6.2.2 Conditions |
54 | 7.6.6.3 Scenario 3 – Heartbeat 7.6.6.3.1 Description Table 15 — Scenario 3 – Heartbeat – Data point list 7.6.6.3.2 Conditions 7.6.6.4 Scenario 4 – Constraints 7.6.6.4.1 Description |
55 | Table 16 — Scenario 4 – Constraints – Data point list 7.6.6.4.2 Conditions 7.6.7 Scenarios and Use Case Functions (UCFs) Table 17 — Limitation of Power Consumption scenarios and primary Use Case Functions (UCFs) 7.6.8 Dependencies to other Use Cases 7.6.8.1 “Monitoring of Power Consumption” |
56 | 7.6.9 Further information and rules 7.6.9.1 Rules regarding the usage of time-related information 7.6.9.2 Sign conventions 7.6.10 Assumptions and Prerequisites 7.7 Limit Consumption to own Production 7.8 Manual Operation 7.8.1 General |
57 | 7.8.2 Actors 7.8.2.1 General 7.8.2.2 CCM 7.8.2.3 Device 7.8.2.4 User 7.8.3 Scenario Overview 7.8.4 Dependencies to other Use Cases 7.8.5 Assumptions and Prerequisites 7.9 Monitoring and Control of Smart Grid Ready Conditions 7.9.1 General |
58 | Figure 28 — High-Level Use Case functionality overview |
59 | 7.9.2 Actors 7.9.2.1 Heat Pump 7.9.2.2 CCM 7.9.3 Scenario overview Figure 29 — Scenario overview 7.9.4 Scenario support requirements |
60 | Table 18 — Scenario implementation requirement for Actors 7.9.5 Scenario flow 7.9.6 Scenario details 7.9.6.1 Scenario 1 – Monitor SG-Ready condition 7.9.6.1.1 Description 7.9.6.1.2 Conditions 7.9.6.2 Scenario 2 – Control SG-Ready condition 7.9.6.2.1 Description 7.9.6.2.2 Conditions |
61 | 7.9.7 Scenarios and Use Case Functions Table 19 — Scenarios and Use Case Functions 7.9.8 Dependencies to other Use Cases 7.9.9 Assumptions and Prerequisites 7.10 Monitoring of Power Consumption 7.10.1 General |
62 | Figure 30 — High-Level Use Case functionality overview 7.10.2 Actors 7.10.2.1 CCM 7.10.2.2 Monitored Unit 7.10.3 Scenario Overview |
63 | Figure 31 — Scenario overview 7.10.4 Scenario Support Requirements Table 20 — Scenario implementation requirements for Actors |
64 | 7.10.5 Scenario Flow 7.10.6 Scenario details 7.10.6.1 Scenario 1 – Monitor power 7.10.6.1.1 Description Table 21 — Scenario 1 – Monitor power consumption – Data point list 7.10.6.1.2 Conditions 7.10.6.2 Scenario 2 – Monitor energy 7.10.6.2.1 Description Table 22 — Scenario 2 – Monitor consumed energy – Data point list |
65 | 7.10.6.2.2 Conditions 7.10.6.3 Scenario 3 – Monitor current 7.10.6.3.1 Description Table 23 — Scenario 3 – Monitor current – Data point list 7.10.6.3.2 Conditions 7.10.6.4 Scenario 4 – Monitor voltage 7.10.6.4.1 Description |
66 | Table 24 — Scenario 4 – Monitor voltage – Data point list 7.10.6.4.2 Conditions 7.10.6.5 Scenario 5 – Monitor frequency 7.10.6.5.1 Description Table 25 — Scenario 3 – Monitor frequency – Data point list 7.10.6.5.2 Conditions 7.10.7 Scenarios and Use Case Functions (UCFs) |
67 | Table 26 — Scenarios and UCFs 7.10.8 Dependencies to other Use Cases 7.10.9 Assumptions and Prerequisites 7.11 Optimization of Self Consumption by Heat Pump Compressor Flexibility 7.11.1 General Figure 32 — High-Level Use Case functionality overview |
68 | 7.11.2 User Story as an example 7.11.3 Detailed background information 7.11.3.1 Overview (informative) Figure 33 — Single electricity meter Figure 34 — Multiple electricity meters |
69 | Figure 35 — PV generation and consumption Figure 36 — Excess and surplus power |
70 | 7.11.4 Actors 7.11.4.1 CCM 7.11.4.2 Heat Pump Compressor 7.11.5 Scenario Overview |
71 | Figure 37 — Scenario overview for Optimization of Self Consumption by Heat Pump Compressor Flexibility 7.11.6 Scenario Support Requirements Table 27 — High-Level Use Case “Optimization of Self Consumption by Heat Pump Compressor Flexibility” scenarios 7.11.7 Scenario Flow |
72 | Figure 38 — Workflow of “phase A” of Scenarios 1, 2 |
73 | Figure 39 — Workflow of “phase B” of Scenarios 1, 2 |
74 | 7.11.8 Scenario Details 7.11.8.1 Scenario 1 – Monitor heat pump compressor’s power consumption flexibility 7.11.8.1.1 Description |
75 | 7.11.8.1.2 Conditions 7.11.8.2 Scenario 2 – Control heat pump compressor’s power consumption flexibility 7.11.8.2.1 Description |
76 | 7.11.8.2.2 Conditions 7.11.9 Scenarios and Use Case Functions (UCFs) Table 28 — Heat Pump Flexibility: Scenarios and primary Use Case Functions (UCFs) 7.11.10 Dependencies to other Use Cases 7.11.11 Assumptions and Prerequisites |
77 | 8 Use Case Function (UCF) details 8.1 General 8.2 Concepts Table 29 — Definition of Data Types for UCFs |
78 | 8.3 UCF_AC_Measurement 8.3.1 Generic Description 8.3.1.1 General Figure 40 — Message sequence of UCF_AC_Measurement |
79 | 8.3.1.2 Measurement 8.3.1.2.1 General 8.3.1.2.2 Measurement: Power 8.3.1.2.2.1 Measurement Description Table 30 — Generic Information content for Measurement Description at Actor Device for Power (for “Monitoring of Power Consumption”) |
80 | 8.3.1.2.2.2 Measurement Constraints Table 31 — Generic Information content for Measurement Constraints at Actor Device for Power 8.3.1.2.2.3 Measurement Data Table 32 — Generic Information content for Measurement Data at Actor Device for Power |
81 | 8.3.1.2.3 Measurement: Energy 8.3.1.2.3.1 Measurement Description Table 33 — Generic Information content for Measurement Description at Actor Device for Energy (for “Monitoring of Power Consumption”) 8.3.1.2.3.2 Measurement Constraints Table 34 — Generic Information content for Measurement Constraints at Actor Device for Energy (for “Monitoring of Power Consumption”) |
82 | 8.3.1.2.3.3 Measurement Data Table 35 — Generic Information content for Measurement Data at Actor Device for Energy (for “Monitoring of Power Consumption”) |
83 | 8.3.1.2.4 Measurement: Current 8.3.1.2.4.1 Measurement Description Table 36 — Generic Information content for Measurement Description at Actor Device for Current 8.3.1.2.4.2 Measurement Constraints Table 37 — Generic Information content for Measurement Constraints at Actor Device for Current |
84 | 8.3.1.2.4.3 Measurement Data Table 38 — Generic Information content for Measurement Data at Actor Device for Current 8.3.1.2.5 Measurement: Voltage 8.3.1.2.5.1 Measurement Description Table 39 — Generic Information content for Measurement Description at Actor Device for Voltage |
85 | 8.3.1.2.5.2 Measurement Constraints Table 40 — Generic Information content for Measurement Constraints at Actor Device for Voltage 8.3.1.2.5.3 Measurement Data Table 41 — Generic Information content for Measurement Data at Actor Device for Voltage |
86 | 8.3.1.2.6 Measurement: Frequency 8.3.1.2.6.1 Measurement Description Table 42 — Generic Information content for Measurement Description at Actor Device for Frequency 8.3.1.2.6.2 Measurement Constraints Table 43 — Generic Information content for Measurement Constraints at Actor Device for Frequency |
87 | 8.3.1.2.6.3 Measurement Data Table 44 — Generic Information content for Measurement Data at Actor Device for Frequency 8.3.1.3 Electrical Connection Data 8.3.1.3.1 General 8.3.1.3.2 Electrical Connection: Power 8.3.1.3.2.1 Electrical Connection Description |
88 | Table 45 — Generic Information content for Electrical Connection Description at Actor Device – Power 8.3.1.3.2.2 Electrical Connection Parameters Description Table 46 — Generic Information content for Electrical Connection Parameters for phase-specific power measurements at Actor Device (for “Monitoring of Power Consumption”) |
89 | Table 47 — Generic Information content for Electrical Parameters for non-phase-specific power measurements at Actor Device (for “Monitoring of Power Consumption”) 8.3.1.3.3 Electrical Connection: Energy 8.3.1.3.3.1 Electrical Connection Description Table 48 — Generic Information content for Electrical Connection Description at Actor Device – Energy |
90 | 8.3.1.3.3.2 Electrical Connection Parameters Description Table 49 — Generic Information content for Electrical Connection Parameters at Actor Device – Energy 8.3.1.3.4 Electrical Connection: Current 8.3.1.3.4.1 Electrical Connection Description Table 50 — Generic Information content for Electrical Connection Description at Actor Device – Current |
91 | 8.3.1.3.4.2 Electrical Connection Parameters Table 51 — Generic Information content for Electrical Connection Parameters at Actor Device – Current 8.3.1.3.5 Electrical Connection: Voltage 8.3.1.3.5.1 Electrical Connection Description Table 52 — Generic Information content for Electrical Connection Description at Actor Device – Voltage (for “Monitoring of Power Consumption”) |
92 | 8.3.1.3.5.2 Electrical Connection Parameters Table 53 — Generic Information content for Electrical Connection Parameters at Actor Device – Voltage 8.3.1.3.6 Electrical Connection: Frequency 8.3.1.3.6.1 Electrical Connection Description |
93 | Table 54 — Generic Information content for Electrical Connection Description at Actor Device – Frequency 8.3.1.3.6.2 Electrical Connection Parameters Table 55 — Generic Information content for Electrical Connection Parameters at Actor Device – Frequency 8.3.2 Additional Information 8.4 UCF_Characteristics 8.4.1 Generic Description 8.4.1.1 General |
94 | Figure 41 — Message sequence of UCF_Characteristics |
95 | 8.4.1.2 Characteristics Table 56 — Generic Information content for Characteristics at Actor Device 8.4.2 Additional Information 8.5 UCF_Configure_Current_Power_Sequence 8.5.1 Generic Description 8.5.1.1 General |
96 | Figure 42 — Message sequence of UCF_Configure_Current_Power_Sequence 8.5.1.2 Pause/Resume/Stop Current Power Sequence |
97 | Table 57 — Information content for Pause/Resume/Stop at Actor CCM 8.5.1.3 Additional Information 8.5.2 Additional Information 8.6 UCF_Consumption_Curve 8.6.1 Generic Description 8.6.1.1 General |
98 | Figure 43 — Messaging sequence for UCF_Consumption_Curve 8.6.1.2 Consumption Curve 8.6.1.2.1 General |
99 | 8.6.1.2.2 Time Series Description Table 59 — Information content for Time Series Description at Actor Device (Scenario 2+5) |
100 | Table 60 — Information content for Time Series Description at Actor Device (Scenario 3) |
101 | 8.6.1.2.3 Time Series Data Table 61 — Information content for Time Series Data at Actor Device (Scenario 2, 3+5) |
102 | 8.6.2 Additional Information 8.7 UCF_Device_Configuration 8.7.1 Generic Description 8.7.1.1 General |
103 | Figure 44 — Message sequence of UCF_Device_Configuration 8.7.1.2 Device Configuration Data 8.7.1.2.1 Key Value Description Table 62 — Generic Information content for Device Configuration Data at Actor Controllable System – Failsafe Power Limits |
104 | Table 63 — Generic Information content for Device Configuration Data at Actor Controllable System – Failsafe Duration Minimum Table 64 — Generic Information content for Device Configuration Data at Actor Energy Consumer – Incentives Simulation Cycles Max Table 65 — Generic Information content for Device Configuration Data at Actor Energy Consumer – Incentives Simulation Concurrent |
105 | Table 66 — Generic Information content for Device Configuration Data at Actor Energy Consumer – Incentives Timeout Incentive Request, Incentives Wait Incentive Writeable 8.7.1.2.2 Key Value Data Table 67 — Generic Information content for Device Configuration Data at Actor Controllable System – Failsafe Power Limits Table 68 — Generic Information content for Device Configuration Data at Actor Grid Connection Point – PV Curtailment Limit Factor, Actor Energy Consumer – Incentives Simulation Cycles Max |
106 | Table 69 — Generic Information content for Device Configuration Data at Actor Actor Energy Consumer – Incentives Simulation Concurrent Table 70 — Generic Information content for Device Configuration Data at Actor Controllable System – Failsafe Duration Minimum Table 71 — Generic Information content for Device Configuration Data at Actor Energy Consumer – Incentives Timeout Incentive Request, Incentives Wait Incentive Writeable 8.7.1.3 Write Device Configuration Data 8.7.1.3.1 General |
107 | 8.7.1.3.2 Key Value Description Table 72 — Generic Information content for Device Configuration Data at Actor Controllable System – Failsafe Power Limit Table 73 — Generic Information content for Device Configuration Data at Actor Controllable System – Failsafe Duration Minimum 8.7.1.3.3 Key Value Data Table 74 — Generic Information content for Device Configuration Data at Actor Controllable System – Failsafe Power Limits |
108 | Table 75 — Generic Information content for Device Configuration Data at Actor Controllable System – Failsafe Duration Minimum 8.7.2 Additional Information 8.8 UCF_Device_Connected 8.8.1 Generic Description 8.8.1.1 General Figure 45 — Communication sequence diagram for UCF_Device_Connected |
109 | 8.8.1.2 Information Content 8.8.2 Additional Information 8.9 UCF_Heartbeat 8.9.1 Generic Description 8.9.1.1 General Figure 46 — Runtime messaging sequence for UCF_Heartbeat |
110 | 8.9.1.2 Heartbeat Table 76 — Information content for Heartbeat at Actor CCM or Device 8.9.2 Additional Information 8.10 UCF_Incentive_Table 8.10.1 Generic Description 8.10.1.1 General Figure 47 — MESSAGING SEQUENCE FOR UCF_INCENTIVE_TABLE |
111 | 8.10.1.2 Incentive Table 8.10.1.2.1 General 8.10.1.2.2 Incentive Table Description Table 77 — Information content for Incentive Table Description at Actor Device (Scenario 2+4) |
115 | Table 78 — Information content for Incentive Table Description at Actor Device (Scenario 3) |
117 | 8.10.1.2.3 Incentive Table Constraints Table 79 — Information content for Incentive Table Constraints at Actor Device (Scenario 2, 3+4) |
118 | 8.10.1.2.4 Incentive Table Data Table 80 — Information content for Incentive Table Data at Actor Device (Scenario 2+4) |
120 | Table 81 — Information content for Incentive Table Data at Actor Device (Scenario 3) |
122 | 8.10.1.3 Write Incentive Table 8.10.1.3.1 Incentive Table Description Table 82 — Information content for Incentive Table Description at Actor Device (Scenario 2+4) |
125 | Table 83 — Information content for Incentive Table Description at Actor Device (Scenario 3) |
128 | 8.10.1.3.2 Incentive Table Data Table 84 — Information content for Incentive Table Data at Actor Device (Scenario 2+4) |
131 | Table 85 — Information content for Incentive Table Data at Actor Device (Scenario 3) |
133 | 8.10.2 Additional Information 8.11 UCF_Overrun 8.11.1 Generic Description 8.11.1.1 General Figure 48 — Sequence diagram for UCF_Overrun 8.11.1.2 Overrun 8.11.1.2.1 System Function Description 8.11.1.2.2 System Function Data |
134 | 8.11.1.2.3 Overrun Description Table 86 — Information Content of Overrun Description 8.11.1.2.4 Overrun Data Table 87 — Information Content of HVAC Overrun Data 8.11.2 Additional Information |
135 | 8.12 UCF_Plan_With_Power_Sequences 8.12.1 Generic Description 8.12.1.1 General Figure 49 — Message sequence of UCF_Plan_With_Power_Sequences 8.12.1.2 Power Plan |
136 | Table 88 — Information content for Power Plan for Use Case “Flexible Start for White Goods” at Actor Device |
139 | Table 89 — Details for “Power Sequence” references of Table 88 without “completed” for (*P1) (see (*S1)) |
140 | Table 90 — Information content for Power Plan for Use Case “Optimization of Self-Consumption by Heat Pump Flexibility” at Actor Device |
142 | 8.12.1.3 States |
143 | Figure 50 — Valid state transitions of a Device Table 91 — Description of state transitions of a power sequence |
144 | 8.12.2 Additional Information 8.13 UCF_Power_Limit 8.13.1 Generic Description 8.13.1.1 General Figure 51 — Generic Message sequence of UCF_Power_Limit |
145 | 8.13.1.2 Current Active Power Limit, Send Active Power Limit 8.13.1.2.1 Active Power Limit Description Table 92 — Generic Information content for Active Power Limit Description at Actors Device and CCM 8.13.1.2.2 Active Power Limit Data Table 93 — Generic Information content for Active Power Limit Data at Actor Device |
146 | 8.13.1.2.3 Active Power Limit Data Table 94 — Generic Information content for Active Power Limit Data at Actor CCM 8.13.2 Additional Information 8.14 UCF_Report_Status_Of_Power_Sequence 8.14.1 Generic Description 8.14.1.1 General |
147 | Figure 52 — Message sequence of UCF_Report_Status_Of_Power_Sequence 8.14.1.2 Status of Power Sequence |
148 | Table 95 — Information content for Status of Power Sequence at Actor Device |
150 | 8.14.2 Additional Information 8.15 UCF_Select_Power_Sequence 8.15.1 Generic Description 8.15.1.1 General Figure 53 — Message sequence of UCF_Select_Power_Sequence |
151 | 8.15.1.2 Select Interaction |
152 | Table 96 — Information content for UCF_Select_Power_Sequence at Actor CCM 8.15.1.3 Additional Information |
153 | 8.15.2 Additional Information 8.16 UCF_Shift_Preferred_Power_Sequence 8.16.1 Generic Description 8.16.1.1 General Figure 54 — Message sequence of UCF_Shift_Preferred_Power_Sequence 8.16.1.2 Shift Interaction |
154 | Table 97 — Information content for UCF_Shift_Preferred_Power_Sequence at Actor CCM 8.16.2 Additional Information 8.17 UCF_System_Function 8.17.1 Generic Description 8.17.1.1 General |
155 | Figure 55 — Sequence diagram for UCF_HVAC_System_Function 8.17.1.2 System Function 8.17.1.2.1 System Function Description Table 98 — Information Content of System Function Description |
156 | 8.17.1.2.2 System Function Operation Mode Relation 8.17.1.2.3 Operation Mode Description 8.17.1.2.4 System Function Data 8.17.2 Additional Information 9 Glossary of definitions for UCFs Table 99 — Definitions for Elements |
164 | Bibliography |