BSI PD CLC/TR 62453-61:2009:2010 Edition
$167.15
Field device tool interface (FDT) specification – Device type manager (DTM). Styleguide for common object model
Published By | Publication Date | Number of Pages |
BSI | 2010 | 38 |
IEC/TR 62453-61, which is a technical report, explains the guidelines and rules for the implementation of a Device Type Manager (DTM) with regard to the user interface and its functions. These guidelines and rules are part of the FDT specification and are intended to ensure that all users are provided with clear and consistent user interface functions and features across DTM devices in a system.
PDF Catalog
PDF Pages | PDF Title |
---|---|
6 | CONTENTS |
8 | INTRODUCTION Figures FigureĀ 1 ā Part 61 of the IECĀ 62453 series |
9 | 1 Scope 2 Normative references 3 Terms, definitions, symbols, abbreviated terms and conventions 3.1 Terms and definitions 3.2 Symbols and abbreviated terms |
10 | 3.3 Conventions 4 Principles for designing DTM user interfaces |
11 | 5 Benefits from the FDT userās point of view |
12 | FigureĀ 2 ā Standard User Interface (SUI) |
13 | 6 Functions of a DTM 6.1 General 6.2 Function āMain operationā FigureĀ 3 ā Advanced User Interface (AUI) |
14 | 6.3 Functions āOnline Parameterizeā and āOffline Parameterizeā 7 DTM user interface 7.1 Objective 7.2 General behavior |
15 | 7.3 Microsoft Active Accessibility 7.4 Appearance |
16 | FigureĀ 4 ā Areas of an SUI |
17 | FigureĀ 5 ā Areas of an AUI |
18 | Tableaux TableĀ 1 ā Contents of Identification Area |
19 | TableĀ 2 ā Contents of Action Area |
20 | TableĀ 3 ā Contents of Status Bar TableĀ 4 ā Possible connection states |
21 | TableĀ 5 ā Possible data source states TableĀ 6 ā Possible states of the instance data set TableĀ 7 ā Possible device diagnostic states (see [1]) |
22 | 7.5 Parameter handling |
23 | FigureĀ 6 ā State diagram: Continuous Check |
24 | FigureĀ 7 ā State diagram: One Time Check FigureĀ 8 ā Parameter value and associated information |
25 | TableĀ 8 ā Possible states of parameters |
26 | 8 Representation of DTM functions TableĀ 9 ā Display of inadmissible or wrong data |
27 | TableĀ 10 ā Representation of functions |
29 | 9 DTM behavior 9.1 Close of user interface with modified parameter values 9.2 Data set |
30 | 9.3 Online parameterization / data source: device 9.4 Offline parameterization / data source: data set |
31 | 9.5 Error handling 9.6 Communication |
32 | 9.7 Access rights 9.8 Localization 9.9 Documentation TableĀ 11 ā Relation between user roles and parameter classes |
33 | 9.10 Installation and un-installation TableĀ 12 ā Installation and un-installation |
35 | Bibliography |