Shopping Cart

No products in the cart.

ICC IBC 2015

$72.50

International Building Code

Published By Publication Date Number of Pages
ICC 2015 733
Guaranteed Safe Checkout
Category:

If you have any questions, feel free to reach out to our online customer service team by clicking on the bottom right corner. We’re here to assist you 24/7.
Email:[email protected]

The scope of the International Building Code® (IBC®) includes all buildings except detached one- and two-family dwellings and townhouses up to three stories.

PDF Catalog

PDF Pages PDF Title
1 2015 INTERNATIONAL BUILDING CODE
2 2015 IBC® INTERNATIONAL BUILDING CODE® TITLE PAGE
3 COPYRIGHT
4 PREFACE
10 EFFECTIVE USE OF THE INTERNATIONAL BUILDING CODE
20 LEGISLATION
22 TABLE OF CONTENTS
30 CHAPTER 1: SCOPE AND ADMINISTRATION
PART 1—SCOPE AND APPLICATION
SECTION 101 GENERAL
SECTION 102 APPLICABILITY
31 PART 2—ADMINISTRATION AND ENFORCEMENT
SECTION 103 DEPARTMENT OF BUILDING SAFETY
SECTION 104 DUTIES AND POWERS OF BUILDING OFFICIAL
33 SECTION 105 PERMITS
35 SECTION 106 FLOOR AND ROOF DESIGN LOADS
SECTION 107 SUBMITTAL DOCUMENTS
36 SECTION 108 TEMPORARY STRUCTURES AND USES
SECTION 109 FEES
37 SECTION 110 INSPECTIONS
38 SECTION 111 CERTIFICATE OF OCCUPANCY
SECTION 112 SERVICE UTILITIES
SECTION 113 BOARD OF APPEALS
39 SECTION 114 VIOLATIONS
SECTION 115 STOP WORK ORDER
SECTION 116 UNSAFE STRUCTURES AND EQUIPMENT
40 CHAPTER 2: DEFINITIONS
SECTION 201 GENERAL
SECTION 202 DEFINITIONS
70 CHAPTER 3: USE AND OCCUPANCY CLASSIFICATION
SECTION 301 GENERAL
SECTION 302 CLASSIFICATION
SECTION 303 ASSEMBLY GROUP A
71 SECTION 304 BUSINESS GROUP B
SECTION 305 EDUCATIONAL GROUP E
SECTION 306 FACTORY GROUP F
72 SECTION 307 HIGH-HAZARD GROUP H
74 TABLE 307.1(1) MAXIMUM ALLOWABLE QUANTITY PER CONTROL AREA OF HAZARDOUS MATERIALS POSING A PHYSICAL HAZARD
75 TABLE 307.1(1)—continued MAXIMUM ALLOWABLE QUANTITY PER CONTROL AREA OF HAZARDOUS MATERIALS POSING A PHYSICAL HAZARD
76 TABLE 307.1(2) MAXIMUM ALLOWABLE QUANTITY PER CONTROL AREA OF HAZARDOUS MATERIAL POSING A HEALTH HAZARD
77 SECTION 308 INSTITUTIONAL GROUP I
78 SECTION 309 MERCANTILE GROUP M
SECTION 310 RESIDENTIAL GROUP R
79 SECTION 311 STORAGE GROUP S
80 SECTION 312 UTILITY AND MISCELLANEOUS GROUP U
82 CHAPTER 4: SPECIAL DETAILED REQUIREMENTS BASEDON USE AND OCCUPANCY
SECTION 401 SCOPE
SECTION 402 COVERED MALL AND OPEN MALL BUILDINGS
85 EQUATION 4-1
86 SECTION 403: HIGH-RISE BUILDINGS
87 TABLE 403.2.4 MINIMUM BOND STRENGTH
89 SECTION 404 ATRIUMS
90 SECTION 405 UNDERGROUND BUILDINGS
91 SECTION 406 MOTOR-VEHICLE-RELATED OCCUPANCIES
93 TABLE 406.5.4 OPEN PARKING GARAGES AREA AND HEIGHT
95 SECTION 407 GROUP I-2
98 SECTION 408 GROUP I-3
100 SECTION 409 MOTION PICTURE PROJECTION ROOMS
101 SECTION 410 STAGES, PLATFORMS AND TECHNICAL PRODUCTION AREAS
103 SECTION 411 SPECIAL AMUSEMENT BUILDINGS
SECTION 412 AIRCRAFT-RELATED OCCUPANCIES
104 TABLE 412.3.1 HEIGHT LIMITATIONS FOR AIRPORT TRAFFIC CONTROL TOWERS
105 TABLE 412.4.6 HANGAR FIRE SUPPRESSION REQUIREMENTS
106 TABLE 412.7 AIRCRAFT MANUFACTURING EXIT ACCESS TRAVEL DISTANCE
SECTION 413 COMBUSTIBLE STORAGE
107 SECTION 414 HAZARDOUS MATERIALS
TABLE 414.2.2 DESIGN AND NUMBER OF CONTROL AREAS
108 TABLE 414.2.5(1) MAXIMUM ALLOWABLE QUANTITY PER INDOOR AND OUTDOOR CONTROL AREA IN GROUP M AND S OCCUPANCIES NONFLAMMABLE SOLIDS AND NONFLAMMABLE AND NONCOMBUSTIBLE LIQUIDS
109 TABLE 414.2.5(2) MAXIMUM ALLOWABLE QUANTITY OF FLAMMABLE AND COMBUSTIBLE LIQUIDS IN WHOLESALE AND RETAIL SALES OCCUPANCIES PER CONTROL AREA
110 TABLE 414.5.1 EXPLOSION CONTROL REQUIREMENTS
SECTION 415 GROUPS H-1, H-2, H-3, H-4 AND H-5
112 TABLE 415.6.2 DETACHED BUILDING REQUIRED
115 TABLE 415.11.1.1.1 QUANTITY LIMITS FOR HAZARDOUS MATERIALS IN A SINGLE FABRICATION AREA IN GROUP H-5a
120 SECTION 416 APPLICATION OF FLAMMABLE FINISHES
SECTION 417 DRYING ROOMS
SECTION 418 ORGANIC COATINGS
SECTION 419 LIVE/WORK UNITS
121 SECTION 420 GROUPS I-1, R-1, R-2, R-3 AND R-4
122 SECTION 421 HYDROGEN FUEL GAS ROOMS
SECTION 422 AMBULATORY CARE FACIILITIES
123 SECTION 423 STORM SHELTERS
SECTION 424 CHILDREN’S PLAY STRUCTURES
124 SECTION 425 HYPERBARIC FACILITIES
SECTION [F] 426 COMBUSTIBLE DUSTS, GRAIN PROCESSING AND STORAGE
126 CHAPTER 5: GENERAL BUILDING HEIGHTS AND AREAS
SECTION 501 GENERAL
SECTION 502 DEFINITIONS
SECTION 503 GENERAL BUILDING HEIGHT AND AREA LIMITATIONS
SECTION 504 BUILDING HEIGHT AND NUMBER OF STORIES
127 TABLE 504.3a ALLOWABLE BUILDING HEIGHT IN FEET ABOVE GRADE PLANE
SECTION 505 MEZZANINES AND EQUIPMENT PLATFORMS
128 TABLE 504.4a, b ALLOWABLE NUMBER OF STORIES ABOVE GRADE PLANE
129 TABLE 504.4a, b—continued ALLOWABLE NUMBER OF STORIES ABOVE GRADE PLANE
130 SECTION 506 BUILDING AREA
EQUATION 5-1
131 TABLE 506.2a, b ALLOWABLE AREA FACTOR (At = NS, S1, S13R, or SM, as applicable) IN SQUARE FEET
132 TABLE 506.2a, b—continued ALLOWABLE AREA FACTOR (At = NS, S1, S13R, or SM, as applicable) IN SQUARE FEET
133 TABLE 506.2a,b—continued ALLOWABLE AREA FACTOR (At = NS, S1, S13R, or SM, as applicable) IN SQUARE FEET
EQUATION 5-2
EQUATION 5-3
134 EQUATION 5-4
EQUATION 5-5
SECTION 507 UNLIMITED AREA BUILDINGS
136 SECTION 508 MIXED USE AND OCCUPANCY
137 TABLE 508.4 REQUIRED SEPARATION OF OCCUPANCIES (HOURS)
SECTION 509 INCIDENTAL USES
138 TABLE 509 INCIDENTAL USES
139 SECTION 510 SPECIAL PROVISIONS
142 CHAPTER 6: TYPES OF CONSTRUCTION
SECTION 601 GENERAL
TABLE 601 FIRE-RESISTANCE RATING REQUIREMENTS FOR BUILDING ELEMENTS (HOURS)
SECTION 602 CONSTRUCTION CLASSIFICATION
143 TABLE 602 FIRE-RESISTANCE RATING REQUIREMENTS FOR EXTERIOR WALLS BASED ON FIRE SEPARATION DISTANCE
TABLE 602.4 WOOD MEMBER SIZE EQUIVALENCIES
144 SECTION 603 COMBUSTIBLE MATERIAL IN TYPES I AND II CONSTRUCTION
146 CHAPTER 7: FIRE AND SMOKE PROTECTION FEATURES
SECTION 701 GENERAL
SECTION 702 DEFINITIONS
SECTION 703 FIRE-RESISTANCE RATINGS AND FIRE TESTS
147 SECTION 704 FIRE-RESISTANCE RATING OF STRUCTURAL MEMBERS
149 SECTION 705 EXTERIOR WALLS
TABLE 705.2 MINIMUM DISTANCE OF PROJECTION
150 EQUATION 7-1
151 FIGURE 705.7 EQUIVALENT OPENING FACTOR
EQUATION 7-2
152 TABLE 705.8 MAXIMUM AREA OF EXTERIOR WALL OPENINGS BASED ON FIRE SEPARATION DISTANCE AND DEGREE OF OPENING PROTECTION
153 SECTION 706 FIRE WALLS
154 TABLE 706.4 FIRE WALL FIRE-RESISTANCE RATINGS
156 SECTION 707 FIRE BARRIERS
TABLE 707.3.10 FIRE-RESISTANCE RATING REQUIREMENTS FOR FIRE BARRIER ASSEMBLIES OR HORIZONTAL ASSEMBLIES BETWEEN FIRE AREAS
157 SECTION 708 FIRE PARTITIONS
158 SECTION 709 SMOKE BARRIERS
159 SECTION 710 SMOKE PARTITIONS
SECTION 711 HORIZONTAL ASSEMBLIES
160 SECTION 712 VERTICAL OPENINGS
161 SECTION 713 SHAFT ENCLOSURES
163 SECTION 714 PENETRATIONS
166 SECTION 715 FIRE-RESISTANT JOINT SYSTEMS
SECTION 716 OPENING PROTECTIVES
167 TABLE 716.3 MARKING FIRE-RATED GLAZING ASSEMBLIES
169 TABLE 716.5 OPENING FIRE PROTECTION ASSEMBLIES, RATINGS AND MARKINGS
170 TABLE 716.5—continued OPENING FIRE PROTECTION ASSEMBLIES, RATINGS AND MARKINGS
172 TABLE 716.6 FIRE WINDOW ASSEMBLY FIRE PROTECTION RATINGS
SECTION 717 DUCTS AND AIR TRANSFER OPENINGS
173 TABLE 717.3.2.1 FIRE DAMPER RATING
177 SECTION 718 CONCEALED SPACES
179 SECTION 719 FIRE-RESISTANCE REQUIREMENTS FOR PLASTER
SECTION 720 THERMAL- AND SOUND-INSULATING MATERIALS
180 SECTION 721 PRESCRIPTIVE FIRE RESISTANCE
181 SECTION 722 CALCULATED FIRE RESISTANCE
TABLE 722.2.1.1 MINIMUM EQUIVALENT THICKNESS OF CAST-IN-PLACE OR PRECAST CONCRETE WALLS, LOAD-BEARING ORNONLOAD-BEARING
182 TABLE 721.1(1) MINIMUM PROTECTION OF STRUCTURAL PARTS BASED ON TIME PERIODS FOR VARIOUS NONCOMBUSTIBLE INSULATING MATERIALSm
183 TABLE 721.1(1)—continued MINIMUM PROTECTION OF STRUCTURAL PARTS BASED ON TIME PERIODS FOR VARIOUS NONCOMBUSTIBLE INSULATING MATERIALSm
184 TABLE 721.1(1)—continued MINIMUM PROTECTION OF STRUCTURAL PARTS BASED ON TIME PERIODS FOR VARIOUS NONCOMBUSTIBLE INSULATING MATERIALSm
185 TABLE 721.1(1) —continued MINIMUM PROTECTION OF STRUCTURAL PARTS BASED ON TIME PERIODS FOR VARIOUS NONCOMBUSTIBLE INSULATING MATERIALSm
186 TABLE 721.1(2) RATED FIRE-RESISTANCE PERIODS FOR VARIOUS WALLS AND PARTITIONS
187 TABLE 721.1(2)—continued RATED FIRE-RESISTANCE PERIODS FOR VARIOUS WALLS AND PARTITIONS
188 TABLE 721.1(2) —continued RATED FIRE-RESISTANCE PERIODS FOR VARIOUS WALLS AND PARTITIONS
189 TABLE 721.1(2)—continued RATED FIRE-RESISTANCE PERIODS FOR VARIOUS WALLS AND PARTITIONS
190 TABLE 721.1(2)—continued RATED FIRE-RESISTANCE PERIODS FOR VARIOUS WALLS AND PARTITION
191 TABLE 721.1(2)—continued RATED FIRE-RESISTANCE PERIODS FOR VARIOUS WALLS AND PARTITIONS
192 TABLE 721.1(2)—continued RATED FIRE-RESISTANCE PERIODS FOR VARIOUS WALLS AND PARTITIONS
193 TABLE 721.1(2)—continued RATED FIRE-RESISTANCE PERIODS FOR VARIOUS WALLS AND PARTITIONS
194 TABLE 721.1(2)—continued RATED FIRE-RESISTANCE PERIODS FOR VARIOUS WALLS AND PARTITIONS
TABLE 721.1(3) MINIMUM PROTECTION FOR FLOOR AND ROOF SYSTEMS
195 TABLE 721.1(3)—continued MINIMUM PROTECTION FOR FLOOR AND ROOF SYSTEMS
196 TABLE 721.1(3)—continued MINIMUM PROTECTION FOR FLOOR AND ROOF SYSTEMS
197 TABLE 721.1(3) —continued MINIMUM PROTECTION FOR FLOOR AND ROOF SYSTEMS
198 TABLE 721.1(3) —continued MINIMUM PROTECTION FOR FLOOR AND ROOF SYSTEM
199 TABLE 721.1(3)—continued MINIMUM PROTECTION FOR FLOOR AND ROOF SYSTEMS
200 TABLE 721.1(3)—continued MINIMUM PROTECTION FOR FLOOR AND ROOF SYSTEMS
201 TABLE 721.1(3)—continued MINIMUM PROTECTION FOR FLOOR AND ROOF SYSTEM
202 TABLE 721.1(3)—continued MINIMUM PROTECTION FOR FLOOR AND ROOF SYSTEMS
203 TABLE 721.1(3)—continued MINIMUM PROTECTION FOR FLOOR AND ROOF SYSTEM
204 TABLE 721.1(3)—continued MINIMUM PROTECTION FOR FLOOR AND ROOF SYSTEMS
205 EQUATION 7-3
EQUATION 7-4
FIGURE 722.2.1.2 FIRE-RESISTANCE RATINGS OF TWO-WYTHE CONCRETE WALLS
206 TABLE 722.2.1.2(1) VALUES OF Rn0.59 FOR USE IN EQUATION 7-4
TABLE 722.2.1.2(2) FIRE-RESISTANCE RATINGS BASED ON R0.59
FIGURE 722.2.1.3.1 CERAMIC FIBER JOINT PROTECTION
207 TABLE 722.2.1.4(1) MULTIPLYING FACTOR FOR FINISHES ON NONFIRE-EXPOSED SIDE OF WALL
TABLE 722.2.1.4(2) TIME ASSIGNED TO FINISH MATERIALS ON FIRE-EXPOSED SIDE OF WALL
208 TABLE 722.2.2.1 MINIMUM SLAB THICKNESS (inches)
FIGURE 722.2.2.1.2 DETERMINATION OF SLAB THICKNESS FOR SLOPING SOFFITS
EQUATION 7-5
FIGURE 722.2.2.1.3 SLABS WITH RIBBED OR UNDULATING SOFFITS
209 FIGURE 722.2.2.2 FIRE-RESISTANCE RATINGS FOR TWO-COURSE CONCRETE FLOORS
FIGURE 722.2.2.3(1) FIRE-RESISTANCE RATINGS FOR CONCRETE ROOF ASSEMBLIES
210 FIGURE 722.2.2.3(2) FIRE-RESISTANCE RATINGS FOR CONCRETE ROOF ASSEMBLIES
TABLE 722.2.4 MINIMUM DIMENSION OF CONCRETE COLUMNS (inches)
TABLE 722.2.3(1) COVER THICKNESS FOR REINFORCED CONCRETE FLOOR OR ROOF SLABS (inches)
TABLE 722.2.3(2) COVER THICKNESS FOR PRESTRESSED CONCRETE FLOOR OR ROOF SLABS (inches)
211 TABLE 722.2.3(3) MINIMUM COVER FOR MAIN REINFORCING BARS OF REINFORCED CONCRETE BEAMSc (APPLICABLE TO ALL TYPES OF STRUCTURAL CONCRETE)
TABLE 722.2.3(4) MINIMUM COVER FOR PRESTRESSED CONCRETE BEAMS 8 INCHES OR GREATER IN WIDT
TABLE 722.2.3(5) MINIMUM COVER FOR PRESTRESSED CONCRETE BEAMS OF ALL WIDTHS
212 EQUATION 7-6
TABLE 722.3.2 MINIMUM EQUIVALENT THICKNESS (inches) OF BEARING OR NONBEARING CONCRETE MASONRY WALLS
213 EQUATION 7-7
TABLE 722.3.4 MINIMUM COVER OF LONGITUDINAL REINFORCEMENT INFIRE-RESISTANCE-RATED REINFORCED CONCRETE MASONRY LINTELS (inches)
TABLE 722.3.5 MINIMUM DIMENSION OF CONCRETE MASONRY COLUMNS (inches
EQUATION 7-8
214 EQUATION 7-9
TABLE 722.4.1(1) FIRE-RESISTANCE PERIODS OF CLAY MASONRY WALLS
TABLE 722.4.1(2) FIRE-RESISTANCE RATINGS FOR BEARING STEEL FRAME BRICK VENEER WALLS OR PARTITIONS
215 TABLE 722.4.1(3) VALUES OF Rn 0.59
TABLE 722.4.1(4) COEFFICIENTS FOR PLASTER, pl a
TABLE 722.4.1(5) REINFORCED MASONRY LINTELS
TABLE 722.4.1(6) REINFORCED CLAY MASONRY COLUMNS
EQUATION 7-10
EQUATION 7-11
216 FIGURE 722.5.1(1) DETERMINATION OF THE HEATED PERIMETER OF STRUCTURAL STEEL COLUMNS
EQUATION 7-12
FIGURE 722.5.1(2) GYPSUM-PROTECTED STRUCTURAL STEEL COLUMNS WITH SHEET STEEL COLUMN COVERS
217 FIGURE 722.5.1(3) GYPSUM-PROTECTED STRUCTURAL STEEL COLUMNS WITH STEEL STUD/SCREW ATTACHMENT SYSTEM
FIGURE 722.5.1(4) FIRE RESISTANCE OF STRUCTURALSTEEL COLUMNS PROTECTED WITH VARIOUS THICKNESSES OF TYPE X GYPSUM WALLBOARD
FIGURE 722.5.1(5) WIDE FLANGE STRUCTURAL STEEL COLUMNS WITH SPRAYED FIRE-RESISTANT MATERIALS
218 FIGURE 722.5.1(6) CONCRETE PROTECTED STRUCTURAL STEEL COLUMNS
FIGURE 722.5.1(7) CONCRETE OR CLAY MASONRY PROTECTED STRUCTURAL STEEL COLUMNS
EQUATION 7-13
219 EQUATION 7-14
EQUATION 7-15
EQUATION 7-16
220 FIGURE 722.5.2 DETERMINATION OF THE HEATED PERIMETER OF STRUCTURAL STEEL BEAMS AND GIRDERS
EQUATION 7-17
221 TABLE 722.5.1(1) W/D RATIOS FOR STEEL COLUMNS
TABLE 722.5.1(2) PROPERTIES OF CONCRETE
222 TABLE 722.5.1(3) THERMAL CONDUCTIVITY OF CONCRETE OR CLAY MASONRY UNITS
TABLE 722.5.1(4) WEIGHT-TO-HEATED-PERIMETER RATIOS (W/D) FOR TYPICAL WIDE FLANGE BEAM AND GIRDER SHAPES
223 TABLE 722.5.1(4)—continued WEIGHT-TO-HEATED-PERIMETER RATIOS (W/D) FOR TYPICAL WIDE FLANGE BEAM AND GIRDER SHAPES
224 TABLE 722.5.1(4)—continued WEIGHT-TO-HEATED-PERIMETER RATIOS (W/D) FOR TYPICAL WIDE FLANGE BEAM AND GIRDER SHAPES
225 TABLE 722.5.1(5) FIRE RESISTANCE OF CONCRETE MASONRY PROTECTED STEEL COLUMNS
226 TABLE 722.5.1(5)—continued FIRE RESISTANCE OF CONCRETE MASONRY PROTECTED STEEL COLUMNS
227 TABLE 722.5.1(6) FIRE RESISTANCE OF CLAY MASONRY PROTECTED STEEL COLUMNS
228 TABLE 722.5.1(7) MINIMUM COVER (inch) FOR STEEL COLUMNS ENCASED IN NORMAL-WEIGHT CONCRETEa [FIGURE 722.5.1(6)(c)]
TABLE 722.5.1(8) MINIMUM COVER (inch) FOR STEEL COLUMNS ENCASED INSTRUCTURAL LIGHTWEIGHT CONCRETEa [FIGURE 722.5.1(6)(c)]
229 TABLE 722.5.1(9) MINIMUM COVER (inch) FOR STEEL COLUMNS IN NORMAL-WEIGHT PRECAST COVERSa [FIGURE 722.5.1(6)(a)]
TABLE 722.5.1(10) MINIMUM COVER (inch) FOR STEEL COLUMNS IN STRUCTURAL LIGHTWEIGHT PRECAST COVERSa [FIGURE 722.5.1(6)(a)]
230 TABLE 722.6.2(1) TIME ASSIGNED TO WALLBOARD MEMBRANESa, b, c, d
231 TABLE 722.6.2(2) TIME ASSIGNED FOR CONTRIBUTION OF WOOD FRAME a, b, c
TABLE 722.6.2(3) MEMBRANEa ON EXTERIOR FACE OF WOOD STUD WALLS
TABLE 722.6.2(4) FLOORING OR ROOFING OVER WOOD FRAMINGa
TABLE 722.6.2(5) TIME ASSIGNED FOR ADDITIONAL PROTECTION
232 CHAPTER 8: INTERIOR FINISHES
SECTION 801 GENERAL
SECTION 802 DEFINITIONS
SECTION 803 WALL AND CEILING FINISHES
234 TABLE 803.11 INTERIOR WALL AND CEILING FINISH REQUIREMENTS BY OCCUPANCYk
235 SECTION 804 INTERIOR FLOOR FINISH
SECTION 805 COMBUSTIBLE MATERIALS IN TYPES I AND II CONSTRUCTION
SECTION 806 DECORATIVE MATERIALS AND TRIM
236 SECTION 807 INSULATION
SECTION 808 ACOUSTICAL CEILING SYSTEMS
238 CHAPTER 9: FIRE PROTECTION SYSTEMS
SECTION 901 GENERAL
SECTION 902 DEFINITIONS
239 SECTION 903 AUTOMATIC SPRINKLER SYSTEMS
241 TABLE 903.2.5.2 GROUP H-5 SPRINKLER DESIGN CRITERIA
243 TABLE 903.2.11.6 ADDITIONAL REQUIRED SUPPRESSION SYSTEMS
245 SECTION 904 ALTERNATIVE AUTOMATIC FIRE-EXTINGUISHING SYSTEMS
248 SECTION 905 STANDPIPE SYSTEMS
250 SECTION 906 PORTABLE FIRE EXTINGUISHERS
251 TABLE 906.1 ADDITIONAL REQUIRED PORTABLE FIRE EXTINGUISHERS IN THE INTERNATIONAL FIRE CODE
TABLE 906.3(1) FIRE EXTINGUISHERS FOR CLASS A FIRE HAZARDS
TABLE 906.3(2) FIRE EXTINGUISHERS FOR FLAMMABLE OR COMBUSTIBLE LIQUIDS WITH DEPTHS LESS THAN OR EQUAL TO 0.25 INCH
252 SECTION 907 FIRE ALARM AND DETECTION SYSTEMS
262 TABLE 907.5.2.3.2 VISIBLE ALARMS
263 SECTION 908 EMERGENCY ALARM SYSTEMS
264 SECTION 909 SMOKE CONTROL SYSTEMS
265 EQUATION 9-1
266 EQUATION 9-3
272 SECTION 910 SMOKE AND HEAT REMOVAL
EQUATION 9-4
273 EQUATION 9-5
SECTION 911 FIRE COMMAND CENTER
274 SECTION 912 FIRE DEPARTMENT CONNECTIONS
275 SECTION 913 FIRE PUMPS
SECTION 914 EMERGENCY RESPONDER SAFETY FEATURES
276 SECTION 915 CARBON MONOXIDE DETECTION
277 SECTION 916 EMERGENCY RESPONDER RADIO COVERAGE
278 CHAPTER 10: MEANS OF EGRESS
SECTION 1001 ADMINISTRATION
SECTION 1002 DEFINITIONS
279 SECTION 1003 GENERAL MEANS OF EGRESS
280 SECTION 1004 OCCUPANT LOAD
TABLE 1004.1.2 MAXIMUM FLOOR AREA ALLOWANCES PER OCCUPANT
281 SECTION 1005 MEANS OF EGRESS SIZING
282 SECTION 1006 NUMBER OF EXITS AND EXIT ACCESS DOORWAYS
283 TABLE 1006.2.1 SPACES WITH ONE EXIT OR EXIT ACCESS DOORWAY
284 TABLE 1006.3.1 MINIMUM NUMBER OF EXITS OR ACCESS TO EXITS PER STORY
TABLE 1006.3.2(1) STORIES WITH ONE EXIT OR ACCESS TO ONE EXIT FOR R-2 OCCUPANCIES
285 1006.3.2(2) STORIES WITH ONE EXIT OR ACCESS TO ONE EXIT FOR OTHER OCCUPANCIES
SECTION 1007 EXIT AND EXIT ACCESS DOORWAY CONFIGURATION
286 SECTION 1008 MEANS OF EGRESS ILLUMINATION
SECTION 1009 ACCESSIBLE MEANS OF EGRESS
289 SECTION 1010 DOORS, GATES AND TURNSTILES
291 TABLE 1010.1.4.1(1) MAXIMUM DOOR SPEED MANUAL REVOLVING DOORS
TABLE 1010.1.4(2) MAXIMUM DOOR SPEED AUTOMATIC OR POWER-OPERATED REVOLVING DOORS
297 SECTION 1011 STAIRWAYS
300 SECTION 1012 RAMPS
301 SECTION 1013 EXIT SIGNS
302 SECTION 1014 HANDRAILS
303 SECTION 1015 GUARDS
305 SECTION 1016 EXIT ACCESS
306 SECTION 1017 EXIT ACCESS TRAVEL DISTANCE
TABLE 1017.2 EXIT ACCESS TRAVEL DISTANCEa
SECTION 1018 AISLES
307 SECTION 1019 EXIT ACCESS STAIRWAYS AND RAMPS
SECTION 1020 CORRIDORS
308 TABLE 1020.1 CORRIDOR FIRE-RESISTANCE RATING
TABLE 1020.2 MINIMUM CORRIDOR WIDTH
309 SECTION 1021 EGRESS BALCONIES
SECTION 1022 EXITS
SECTION 1023 INTERIOR EXIT STAIRWAYS AND RAMPS
311 SECTION 1024 EXIT PASSAGEWAYS
312 SECTION 1025 LUMINOUS EGRESS PATH MARKINGS
313 SECTION 1026 HORIZONTAL EXITS
314 SECTION 1027 EXTERIOR EXIT STAIRWAYS AND RAMPS
315 SECTION 1028 EXIT DISCHARGE
316 SECTION 1029 ASSEMBLY
317 TABLE 1029.6.2 CAPACITY FOR AISLES FOR SMOKE-PROTECTED ASSEMBLY
320 TABLE 1029.12.2.1 SMOKE-PROTECTED ASSEMBLY AISLE ACCESSWAYS
322 SECTION 1030 EMERGENCY ESCAPE AND RESCUE
324 CHAPTER 11: ACCESSIBILITY
SECTION 1101 GENERAL
SECTION 1102 DEFINITIONS
SECTION 1103 SCOPING REQUIREMENTS
325 SECTION 1104 ACCESSIBLE ROUTE
326 SECTION 1105 ACCESSIBLE ENTRANCES
SECTION 1106 PARKING AND PASSENGER LOADING FACILITIES
327 TABLE 1106.1 ACCESSIBLE PARKING SPACES
SECTION 1107 DWELLING UNITS AND SLEEPING UNITS
329 TABLE 1107.6.1.1 ACCESSIBLE DWELLING UNITS AND SLEEPING UNITS
331 SECTION 1108 SPECIAL OCCUPANCIES
332 TABLE 1108.2.2.1 ACCESSIBLE WHEELCHAIR SPACES
TABLE 1108.2.7.1 RECEIVERS FOR ASSISTIVE LISTENING SYSTEMS
333 TABLE 1108.3 ACCESSIBLE SELF-SERVICE STORAGE FACILITIES
334 SECTION 1109 OTHER FEATURES AND FACILITIES
336 TABLE 1109.12.2 ACCESSIBLE CHECK-OUT AISLES
337 SECTION 1110 RECREATIONAL FACILITIES
338 TABLE 1110.4.9.1 BOAT SLIPS
339 SECTION 1111 SIGNAGE
340 CHAPTER 12: INTERIOR ENVIRONMENT
SECTION 1201 GENERAL
SECTION 1202 DEFINITIONS
SECTION 1203 VENTILATION
341 TABLE 1203.3 INSULATION FOR CONDENSATION CONTROL
342 SECTION 1204 TEMPERATURE CONTROL
SECTION 1205 LIGHTING
343 SECTION 1206 YARDS OR COURTS
SECTION 1207 SOUND TRANSMISSION
SECTION 1208 INTERIOR SPACE DIMENSIONS
344 SECTION 1209 ACCESS TO UNOCCUPIED SPACES
SECTION 1210 TOILET AND BATHROOM REQUIREMENTS
346 CHAPTER 13: ENERGY EFFICIENCY
SECTION 1301 GENERAL
348 CHAPTER 14: EXTERIOR WALLS
SECTION 1401 GENERAL
SECTION 1402 DEFINITIONS
SECTION 1403 PERFORMANCE REQUIREMENTS
349 SECTION 1404 MATERIALS
350 SECTION 1405 INSTALLATION OF WALL COVERINGS
TABLE 1405.2 MINIMUM THICKNESS OF WEATHER COVERINGS
351 TABLE 1405.3.2 CLASS III VAPOR RETARDERS
355 SECTION 1406 COMBUSTIBLE MATERIALS ON THE EXTERIOR SIDE OF EXTERIOR WALLS
356 TABLE 1406.2.1.1.2 MINIMUM FIRE SEPARATION FOR COMBUSTIBLE EXTERIOR WALL COVERINGS
SECTION 1407 METAL COMPOSITE MATERIALS (MCM)
358 TABLE 1407.11.3.4 AREA LIMITATION AND SEPARATION REQUIREMENTS FOR MCM PANELS
359 SECTION 1408 EXTERIOR INSULATION AND FINISH SYSTEMS (EIFS)
SECTION 1409 HIGH-PRESSURE DECORATIVE EXTERIOR-GRADE COMPACT LAMINATES (HPL)
360 SECTION 1410 PLASTIC COMPOSITE DECKING
362 CHAPTER 15: ROOF ASSEMBLIES AND ROOFTOP STRUCTURES
SECTION 1501 GENERAL
SECTION 1502 DEFINITIONS
SECTION 1503 WEATHER PROTECTION
363 SECTION 1504 PERFORMANCE REQUIREMENTS
TABLE 1504.1.1 CLASSIFICATION OF ASPHALT SHINGLES
364 TABLE 1504.8 MAXIMUM ALLOWABLE MEAN ROOF HEIGHT PERMITTED FOR BUILDINGS WITH AGGREGATE ON THE ROOF IN AREAS OUTSIDE A HURRICANE-PRONE REGION
SECTION 1505 FIRE CLASSIFICATION
TABLE 1505.1a, b MINIMUM ROOF COVERING CLASSIFICATION FOR TYPES OF CONSTRUCTION
365 SECTION 1506 MATERIALS
SECTION 1507 REQUIREMENTS FOR ROOF COVERINGS
367 TABLE 1507.2.9.2 VALLEY LINING MATERIAL
368 TABLE 1507.3.7 CLAY AND CONCRETE TILE ATTACHMENTa
369 TABLE 1507.4.3(1) METAL ROOF COVERINGS
TABLE 1507.4.3(2) MINIMUM CORROSION RESISTANCE
371 TABLE 1507.7.6 SLATE SHINGLE HEADLAP
372 TABLE 1507.8.5 WOOD SHINGLE MATERIAL REQUIREMENTS
TABLE 1507.8.7 WOOD SHINGLE WEATHER EXPOSURE AND ROOF SLOPE
373 TABLE 1507.8 WOOD SHINGLE AND SHAKE INSTALLATION
374 TABLE 1507.9.6 WOOD SHAKE MATERIAL REQUIREMENTS
375 TABLE 1507.9.8 WOOD SHAKE WEATHER EXPOSURE AND ROOF SLOPE
TABLE 1507.10.2 BUILT-UP ROOFING MATERIAL STANDARDS
376 TABLE 1507.14.3 PROTECTIVE COATING MATERIAL STANDARDS
377 SECTION 1508 ROOF INSULATION
TABLE 1508.2 MATERIAL STANDARDS FOR ROOF INSULATION
SECTION 1509 RADIANT BARRIERS INSTALLED ABOVE DECK
SECTION 1510 ROOFTOP STRUCTURES
380 SECTION 1511 REROOFING
SECTION 1512 PHOTOVOLTAIC PANELS AND MODULES
382 CHAPTER 16: STRUCTURAL DESIGN
SECTION 1601 GENERAL
SECTION 1602 DEFINITIONS AND NOTATIONS
SECTION 1603 CONSTRUCTION DOCUMENTS
383 SECTION 1604 GENERAL DESIGN REQUIREMENTS
384 TABLE 1604.3 DEFLECTION LIMITS
386 TABLE 1604.5 RISK CATEGORY OF BUILDINGS AND OTHER STRUCTURE
SECTION 1605 LOAD COMBINATIONS
387 EQUATION 16-1
EQUATION 16-2
EQUATION 16-3
EQUATION 16-4
EQUATION 16-5
EQUATION 16-6
EQUATION 16-7
EQUATION 16-8
EQUATION 16-9
EQUATION 16-10
EQUATION 16-11
EQUATION 16-12
EQUATION 16-13
EQUATION 16-14
EQUATION 16-15
EQUATION 16-16
388 EQUATION 16-17
EQUATION 16-18
EQUATION 16-19
EQUATION 16-20
EQUATION 16-21
EQUATION 16-22
SECTION 1606 DEAD LOADS
SECTION 1607 LIVE LOADS
389 TABLE 1607.1 MINIMUM UNIFORMLY DISTRIBUTED LIVE LOADS, L0, AND MINIMUM CONCENTRATED LIVE LOAD
TABLE 1607.1—continued MINIMUM UNIFORMLY DISTRIBUTED LIVE LOADS, L0, AND MINIMUM CONCENTRATED LIVE LOADSg
390 TABLE 1607.1—continued MINIMUM UNIFORMLY DISTRIBUTED LIVE LOADS, L0, AND MINIMUM CONCENTRATED LIVE LOADSg
TABLE 1607.1—continued MINIMUM UNIFORMLY DISTRIBUTED LIVE LOADS, Lo, AND MINIMUM CONCENTRATED LIVE LOADSg
392 EQUATION 16-23
TABLE 1607.10.1 LIVE LOAD ELEMENT FACTOR
393 EQUATION 16-24
EQUATION 16-25
EQUATION 16-26
EQUATION 16-27
EQUATION 16-28
EQUATION 16-29
EQUATION 16-30
EQUATION 16-31
EQUATION 16-32
395 SECTION 1608 SNOW LOADS
TABLE 1608.2 GROUND SNOW LOADS, pg, FOR ALASKAN LOCATIONS
SECTION 1609 WIND LOADS
396 TABLE 1609.1.2 WIND-BORNE DEBRIS PROTECTION FASTENING SCHEDULE FOR WOOD STRUCTURAL PANELSa
397 FIGURE 1608.2 GROUND SNOW LOADS, pg, FOR THE UNITED STATES (psf)
398 FIGURE 1608.2—continued GROUND SNOW LOADS, pg, FOR THE UNITED STATES (psf)
399 FIGURE 1609.3(1) ULTIMATE DESIGN WIND SPEEDS, vult, FOR RISK CATEGORY II BUILDINGS AND OTHER STRUCTURES
400 FIGURE 1609.3(2) ULTIMATE DESIGN WIND SPEEDS, vult, FOR RISK CATEGORY III AND IV BUILDINGS AND OTHER STRUCTURES
401 FIGURE 1609.3(3) ULTIMATE DESIGN WIND SPEEDS, vult, FOR RISK CATEGORY I BUILDINGS AND OTHER STRUCTURES
402 EQUATION 16-33
TABLE 1609.3.1 WIND SPEED CONVERSIONSa
403 EQUATION 16-34
404 EQUATION 16-35
SECTION 1610 SOIL LATERAL LOADS
405 TABLE 1609.6.2 NET PRESSURE COEFFICIENTS
406 TABLE 1609.6.2—continued NET PRESSURE COEFFICIENTS
407 TABLE 1609.6.2—continued NET PRESSURE COEFFICIENTS
408 TABLE 1609.6.2—continued NET PRESSURE COEFFICIENTS
TABLE 1610.1 LATERAL SOIL LOAD
409 SECTION 1611 RAIN LOADS
EQUATION 16-36
SECTION 1612 FLOOD LOADS
410 FIGURE 1611.1 100-YEAR, 1-HOUR RAINFALL (INCHES) WESTERN UNITED STATES
411 FIGURE 1611.1—continued 100-YEAR, 1-HOUR RAINFALL (INCHES) CENTRAL UNITED STATES
412 FIGURE 1611.1—continued 100-YEAR, 1-HOUR RAINFALL (INCHES) EASTERN UNITED STATES
413 FIGURE 1611.1—continued 100-YEAR, 1-HOUR RAINFALL (INCHES) ALASKA
414 FIGURE 1611.1—continued 100-YEAR, 1-HOUR RAINFALL (INCHES) HAWAII
415 SECTION 1613 EARTHQUAKE LOADS
416 EQUATION 16-37
EQUATION 16-38
EQUATION 16-39
EQUATION 16-40
TABLE 1613.3.3(1) VALUES OF SITE COEFFICIENT
TABLE 1613.3.3(2) VALUES OF SITE COEFFICIENT
417 FIGURE 1613.3.1(1) RISK-TARGETED MAXIMUM CONSIDERED EARTHQUAKE (MCER) GROUND MOTION RESPONSE ACCELERATIONS FOR THE CONTERMINOUS UNITED STATES OF 0.2-SECOND SPECTRAL RESPONSE ACCELERATION (5% OF CRITICAL DAMPING), SITE CLASS B
418 FIGURE 1613.3.1(1)—continued RISK-TARGETED MAXIMUM CONSIDERED EARTHQUAKE (MCER) GROUND MOTION RESPONSE ACCELERATIONS FOR THE CONTERMINOUS UNITED STATES OF 0.2-SECOND SPECTRAL RESPONSE ACCELERATION (5% OF CRITICAL DAMPING), SITE CLASS B
419 FIGURE 1613.3.1(2) RISK-TARGETED MAXIMUM CONSIDERED EARTHQUAKE (MCER) GROUND MOTION RESPONSE ACCELERATIONS FOR THE CONTERMINOUS UNITED STATES OF 1-SECOND SPECTRAL RESPONSE ACCELERATION (5% OF CRITICAL DAMPING), SITE CLASS B
420 FIGURE 1613.3.1(2)—continued RISK-TARGETED MAXIMUM CONSIDERED EARTHQUAKE (MCER) GROUND MOTION RESPONSE ACCELERATIONS FOR THE CONTERMINOUS UNITED STATES OF 1-SECOND SPECTRAL RESPONSE ACCELERATION (5% OF CRITICAL DAMPING), SITE CLASS B
421 FIGURE 1613.3.1(3) RISK-TARGETED MAXIMUM CONSIDERED EARTHQUAKE (MCER) GROUND MOTION RESPONSE ACCELERATIONS FOR HAWAII OF 0.2- AND 1-SECOND SPECTRAL RESPONSE ACCELERATION (5% OF CRITICAL DAMPING), SITE CLASS B
422 FIGURE 1613.3.1(4) RISK-TARGETED MAXIMUM CONSIDERED EARTHQUAKE (MCER) GROUND MOTION RESPONSE ACCELERATIONS FOR ALASKA OF 0.2-SECOND SPECTRAL RESPONSE ACCELERATION (5% OF CRITICAL DAMPING), SITE CLASS B
423 FIGURE 1613.3.1(5) RISK-TARGETED MAXIMUM CONSIDERED EARTHQUAKE (MCER) GROUND MOTION RESPONSE ACCELERATIONS FOR ALASKA OF 1.0-SECOND SPECTRAL RESPONSE ACCELERATION (5% OF CRITICAL DAMPING), SITE CLASS B
424 FIGURE 1613.3.1(6) RISK-TARGETED MAXIMUM CONSIDERED EARTHQUAKE (MCER) GROUND MOTION RESPONSE ACCELERATIONS FOR PUERTO RICO AND THE UNITED STATES VIRGIN ISLANDS OF 0.2- AND 1-SECOND SPECTRAL RESPONSE ACCELERATION (5% OF CRITICAL DAMPING), SITE CLASS B
425 FIGURE 1613.3.1(7) RISK-TARGETED MAXIMUM CONSIDERED EARTHQUAKE (MCER) GROUND MOTION RESPONSE ACCELERATIONS FOR GUAM AND THE NORTHERN MARIANA ISLANDS OF 0.2- AND 1-SECOND SPECTRAL RESPONSE ACCELERATION (5% OF CRITICAL DAMPING), SITE CLASS B
426 FIGURE 1613.3.1(8) RISK-TARGETED MAXIMUM CONSIDERED EARTHQUAKE (MCER) GROUND MOTION RESPONSE ACCELERATIONS FOR AMERICAN SAMOA OF 0.2- AND 1-SECOND SPECTRAL RESPONSE ACCELERATION (5% OF CRITICAL DAMPING), SITE CLASS B
427 TABLE 1613.3.5(1) SEISMIC DESIGN CATEGORY BASED ON SHORT-PERIOD (0.2 second) RESPONSE ACCELERATION
TABLE 1613.3.5(2) SEISMIC DESIGN CATEGORY BASED ON 1-SECOND PERIOD RESPONSE ACCELERATION
428 SECTION 1614 ATMOSPHERIC ICE LOADS
SECTION 1615 STRUCTURAL INTEGRITY
429 EQUATION 16-41
EQUATION 16-42
430 FIGURE 1615.4 LONGITUDINAL, PERIMETER, TRANSVERSE AND VERTICAL TIES
432 CHAPTER 17: SPECIAL INSPECTIONS AND TESTS
SECTION 1701 GENERAL
SECTION 1702 DEFINITIONS
SECTION 1703 APPROVALS
433 SECTION 1704 SPECIAL INSPECTIONS AND TESTS, CONTRACTOR RESPONSIBILITY AND STRUCTURAL OBSERVATION
435 SECTION 1705 REQUIRED SPECIAL INSPECTIONS AND TESTS
436 TABLE 1705.2.3 REQUIRED SPECIAL INSPECTIONS OF OPEN-WEB STEEL JOISTS AND JOIST GIRDERS
437 TABLE 1705.3 REQUIRED SPECIAL INSPECTIONS AND TESTS OF CONCRETE CONSTRUCTION
438 TABLE 1705.6 REQUIRED SPECIAL INSPECTIONS AND TESTS OF SOILS
TABLE 1705.7 REQUIRED SPECIAL INSPECTIONS AND TESTS OF DRIVEN DEEP FOUNDATION ELEMENTS
439 TABLE 1705.8 REQUIRED SPECIAL INSPECTIONS AND TESTS OF CAST-IN-PLACE DEEP FOUNDATION ELEMENTS
443 SECTION 1706 DESIGN STRENGTHS OF MATERIALS
SECTION 1707 ALTERNATIVE TEST PROCEDURE
SECTION 1708 IN-SITU LOAD TESTS
444 SECTION 1709 PRECONSTRUCTION LOAD TESTS
446 CHAPTER 18: SOILS AND FOUNDATIONS
SECTION 1801 GENERAL
SECTION 1802 DEFINITIONS
SECTION 1803 GEOTECHNICAL INVESTIGATIONS
448 SECTION 1804 EXCAVATION, GRADING AND FILL
449 SECTION 1805 DAMPPROOFING AND WATERPROOFING
450 SECTION 1806 PRESUMPTIVE LOAD-BEARING VALUES OF SOILS
451 TABLE 1806.2 PRESUMPTIVE LOAD-BEARING VALUES
SECTION 1807 FOUNDATION WALLS, RETAINING WALLS AND EMBEDDED POSTS AND POLES
452 TABLE 1807.1.6.2 CONCRETE FOUNDATION WALLSb,
453 TABLE 1807.1.6.3(1) PLAIN MASONRY FOUNDATION WALLSa,
454 TABLE 1807.1.6.3(2) 8-INCH MASONRY FOUNDATION WALLS WITH REINFORCEMENT WHERE d ³ 5 INCHES
455 TABLE 1807.1.6.3(3) 10-INCH MASONRY FOUNDATION WALLS WITH REINFORCEMENT WHERE d ³ 6.75 INCHES
456 EQUATION 18-1
TABLE 1807.1.6.3(4) 12-INCH MASONRY FOUNDATION WALLS WITH REINFORCEMENT WHERE d ³ 8.75 INCHESa, b,
457 EQUATION 18-2
EQUATION 18-3
SECTION 1808 FOUNDATIONS
458 FIGURE 1808.7.1 FOUNDATION CLEARANCES FROM SLOPES
459 TABLE 1808.8.1 MINIMUM SPECIFIED COMPRESSIVE STRENGTH f’c OF CONCRETE OR GROUT
TABLE 1808.8.2 MINIMUM CONCRETE COVER
460 SECTION 1809 SHALLOW FOUNDATIONS
TABLE 1809.7 PRESCRIPTIVE FOOTINGS SUPPORTING WALLS OF LIGHT-FRAME CONSTRUCTIONa
461 SECTION 1810 DEEP FOUNDATIONS
464 TABLE 1810.3.2.6 ALLOWABLE STRESSES FOR MATERIALS USED IN DEEP FOUNDATION ELEMENTS
466 EQUATION 18-4
468 EQUAITON 18-5
EQUATION 18-6
EQUATION 18-7
EQUATION 18-8
469 EQUATION 18-9
EQUATION 18-10
EQUATION 18-11
476 CHAPTER 19: CONCRETE
SECTION 1901 GENERAL
SECTION 1902 DEFINITIONS
SECTION 1903 SPECIFICATIONS FOR TESTS AND MATERIALS
SECTION 1904 DURABILITY REQUIREMENTS
477 SECTION 1905 MODIFICATIONS TO ACI 318
479 SECTION 1906 STRUCTURAL PLAIN CONCRETE
SECTION 1907 MINIMUM SLAB PROVISIONS
480 SECTION 1908 SHOTCRETE
482 CHAPTER 20: ALUMINUM
SECTION 2001 GENERAL
SECTION 2002 MATERIALS
484 CHAPTER 21: MASONRY
SECTION 2101 GENERAL
SECTION 2102 DEFINITIONS AND NOTATIONS
485 SECTION 2103 MASONRY CONSTRUCTION MATERIALS
TABLE 2103.2.3 CERAMIC TILE MORTAR COMPOSITIONS
486 SECTION 2104 CONSTRUCTION
SECTION 2105 QUALITY ASSURANCE
SECTION 2106 SEISMIC DESIGN
SECTION 2107 ALLOWABLE STRESS DESIGN
EQUATION 21-1
487 SECTION 2108 STRENGTH DESIGN OF MASONRY
SECTION 2109 EMPIRICAL DESIGN OF MASONRY
TABLE 2109.2.1 ALLOWABLE STRESS GROSS CROSS-SECTIONAL AREA FOR DRY-STACKED, SURFACE-BONDED CONCRETE MASONRY WALLS
488 EQUATION 21-2
TABLE 2109.3.3.1 ALLOWABLE SHEAR ON BOLTS IN ADOBE MASONRY
489 SECTION 2110 GLASS UNIT MASONRY
SECTION 2111 MASONRY FIREPLACES
491 FIGURE 2111.12 ILLUSTRATION OF EXCEPTION TO FIREPLACE CLEARANCE PROVISION
SECTION 2112 MASONRY HEATERS
492 SECTION 2113 MASONRY CHIMNEYS
495 FIGURE 2113.16 FLUE SIZES FOR MASONRY CHIMNEYS
496 TABLE 2113.16(1) NET CROSS-SECTIONAL AREA OF ROUND FLUE SIZESa
TABLE 2113.16(2) NET CROSS-SECTIONAL AREA OF SQUARE AND RECTANGULAR FLUE SIZES
FIGURE 2113.19 ILLUSTRATION OF EXCEPTION THREE CHIMNEY CLEARANCE PROVISION
498 CHAPTER 22: STEEL
SECTION 2201 GENERAL
SECTION 2202 DEFINITIONS
SECTION 2203 IDENTIFICATION AND PROTECTION OF STEEL FOR STRUCTURAL PURPOSES
SECTION 2204 CONNECTIONS
SECTION 2205 STRUCTURAL STEEL
499 SECTION 2206 COMPOSITE STRUCTURAL STEEL AND CONCRETE STRUCTURES
SECTION 2207 STEEL JOISTS
500 SECTION 2208 STEEL CABLE STRUCTURES
SECTION 2209 STEEL STORAGE RACKS
SECTION 2210 COLD-FORMED STEEL
SECTION 2211 COLD-FORMED STEEL LIGHT-FRAME CONSTRUCTION
502 CHAPTER 23: WOOD
SECTION 2301 GENERAL
SECTION 2302 DEFINITIONS
SECTION 2303 MINIMUM STANDARDS AND QUALITY
506 SECTION 2304 GENERAL CONSTRUCTION REQUIREMENTS
507 TABLE 2304.6.1 MAXIMUM NOMINAL DESIGN WIND SPEED, Vasd PERMITTED FOR WOOD STRUCTURAL PANEL WALL SHEATHING USED TO RESIST WIND PRESSURES
508 TABLE 2304.8(1) ALLOWABLE SPANS FOR LUMBER FLOOR AND ROOF SHEATHING
TABLE 2304.8(2) SHEATHING LUMBER, MINIMUM GRADE REQUIREMENTS: BOARD
TABLE 2304.8(3) ALLOWABLE SPANS AND LOADS FOR WOOD STRUCTURAL PANEL SHEATHING AND SINGLE-FLOOR GRADES CONTINUOUS OVER TWO OR MORE SPANS WITH STRENGTH AXIS PERPENDICULAR TO SUPPORTS
509 TABLE 2304.8(4) ALLOWABLE SPAN FOR WOOD STRUCTURAL PANEL COMBINATION SUBFLOOR-UNDERLAYMENT (SINGLE FLOOR)a,
TABLE 2304.8(5) ALLOWABLE LOAD (PSF) FOR WOOD STRUCTURAL PANEL ROOF SHEATHING CONTINUOUS OVER TWO OR MORE SPANS AND STRENGTH AXIS PARALLEL TO SUPPORTS
512 TABLE 2304.10.1 FASTENING SCHEDULE
513 TABLE 2304.10.1—continued FASTENING SCHEDULE
514 TABLE 2304.10.1—continued FASTENING SCHEDULE
515 TABLE 2304.10.1—continued FASTENING SCHEDULE
516 TABLE 2304.10.1—continued FASTENING SCHEDULE
517 SECTION 2305 GENERAL DESIGN REQUIREMENTS FOR LATERAL FORCE-RESISTING SYSTEMS
EQUATION 23-1
518 TABLE 2305.2(1) en VALUES (inches) FOR USE IN CALCULATING DIAPHRAGM AND SHEAR WALL DEFLECTION DUE TO FASTENER SLIP(Structural I)
TABLE 2305.2(2) VALUES OF Gt FOR USE IN CALCULATING DEFLECTION OF WOOD STRUCTURAL PANEL SHEAR WALLS AND DIAPHRAGMS
EQUATION 23-2
519 SECTION 2306 ALLOWABLE STRESS DESIGN
520 TABLE 2306.1.4 ALLOWABLE LOADS FOR LUMBER DECKING
SECTION 2307 LOAD AND RESISTANCE FACTOR DESIGN
SECTION 2308 CONVENTIONAL LIGHT-FRAME CONSTRUCTION
TABLE 2308.2.1 ALLOWABLE STORY HEIGHT
521 TABLE 2306.2(1) ALLOWABLE SHEAR VALUES (POUNDS PER FOOT) FOR WOOD STRUCTURAL PANEL DIAPHRAGMS UTILIZING STAPLES WITH FRAMING OF DOUGLAS FIR-LARCH, OR SOUTHERN PINEa FOR WIND OR SEISMIC LOADINGf
522 TABLE 2306.2(1)—continued ALLOWABLE SHEAR VALUES (POUNDS PER FOOT) FOR WOOD STRUCTURAL PANEL DIAPHRAGMS UTILIZING STAPLES WITH FRAMING OF DOUGLAS FIR-LARCH, OR SOUTHERN PINEa FOR WIND OR SEISMIC LOADINGf
523 TABLE 2306.2(2) ALLOWABLE SHEAR VALUES (POUNDS PER FOOT) FOR WOOD STRUCTURAL PANEL BLOCKED DIAPHRAGMS UTILIZING MULTIPLE ROWS OF STAPLES (HIGH-LOAD DIAPHRAGMS) WITH FRAMING OF DOUGLAS FIR-LARCH OR SOUTHERN PINEa FOR WIND OR SEISMIC LOADING
524 TABLE 2306.2(2)—continued ALLOWABLE SHEAR VALUES (POUNDS PER FOOT) FOR WOOD STRUCTURAL PANEL BLOCKED DIAPHRAGMS UTILIZING MULTIPLE ROWS OF STAPLES (HIGH-LOAD DIAPHRAGMS) WITH FRAMING OF DOUGLAS FIR-LARCH OR SOUTHERN PINE FOR WIND OR SEISMIC LOADING
525 TABLE 2306.3(1) ALLOWABLE SHEAR VALUES (POUNDS PER FOOT) FOR WOOD STRUCTURAL PANEL SHEAR WALLS UTILIZING STAPLES WITH FRAMING OF DOUGLAS FIR-LARCH OR SOUTHERN PINEa FOR WIND OR SEISMIC LOADING
TABLE 2306.3(2) ALLOWABLE SHEAR VALUES (plf) FOR WIND OR SEISMIC LOADING ON SHEAR WALLS OF FIBERBOARD SHEATHING BOARD CONSTRUCTION UTILIZING STAPLES FOR TYPE V CONSTRUCTION ONLY
526 TABLE 2306.3(3) ALLOWABLE SHEAR VALUES FOR WIND OR SEISMIC FORCES FOR SHEAR WALLS OF LATH AND PLASTER OR GYPSUM BOARD WOOD FRAMED WALL ASSEMBLIES UTILIZING STAPLES
528 TABLE 2308.4.1.1(1) HEADER AND GIRDER SPANSa, b FOR EXTERIOR BEARING WALLS
529 TABLE 2308.4.1.1(1)—continued HEADER AND GIRDER SPANSa, b FOR EXTERIOR BEARING WALLS
TABLE 2308.4.1.1(2) HEADER AND GIRDER SPANSa, b FOR INTERIOR BEARING WALLS
530 TABLE 2308.4.2.1(1) FLOOR JOIST SPANS FOR COMMON LUMBER SPECIES
531 TABLE 2308.4.2.1(1)—continued FLOOR JOIST SPANS FOR COMMON LUMBER SPECIES
532 TABLE 2308.4.2.1(2) FLOOR JOIST SPANS FOR COMMON LUMBER SPECIES
533 TABLE 2308.4.2.1(2)—continued FLOOR JOIST SPANS FOR COMMON LUMBER SPECIES
534 FIGURE 2308.4.4.1(1) OPENINGS IN FLOOR AND ROOF DIAPHRAGMS
535 FIGURE 2308.4.4.1(2) OPENING LIMITATIONS FOR FLOOR AND ROOF DIAPHRAGMS
FIGURE 2308.4.4.2 PORTIONS OF FLOOR LEVEL OFFSET VERTICALLY
536 TABLE 2308.5.1 SIZE, HEIGHT AND SPACING OF WOOD STUDSc
537 TABLE 2308.5.11 MINIMUM THICKNESS OF WALL SHEATHING
538 FIGURE 2308.6.1 BASIC COMPONENTS OF THE LATERAL BRACING SYSTEM
539 TABLE 2308.6.1a WALL BRACING REQUIREMENTS
540 TABLE 2308.6.3(1) BRACING METHODS
541 TABLE 2308.6.3(1)—continued BRACING METHODS
TABLE 2308.6.3(2) EXPOSED PLYWOOD PANEL SIDING
542 TABLE 2308.6.3(3) WOOD STRUCTURAL PANEL WALL SHEATHINGb (Not Exposed to the Weather, Strength Axis Parallel or Perpendicular to Studs Except as Indicated Below)
TABLE 2308.6.3(4) ALLOWABLE SPANS FOR PARTICLE BOARD WALL SHEATHING (Not Exposed to the Weather, Long Dimension of the Panel Parallel or Perpendicular to Studs)
TABLE 2308.6.3(5) HARDBOARD SIDING
543 FIGURE 2308.6.5.1 ALTERNATE BRACED WALL PANEL (ABW)
544 FIGURE 2308.6.5.2 PORTAL FRAME WITH HOLD-DOWNS (PFH)
545 FIGURE 2308.6.7.2(1) BRACED WALL LINE TOP PLATE CONNECTION
546 FIGURE 2308.6.7.2(2) BRACED WALL PANEL TOP PLATE CONNECTION
547 FIGURE 2308.6.8.2(1) ROOF IN SDC D OR E NOT SUPPORTED ON ALL EDGES
FIGURE 2308.6.8.2(2) ROOF EXTENSION IN SDC D OR E BEYOND BRACED WALL LINE
548 FIGURE 2308.6.8.3 STEPPED FOOTING CONNECTION DETAILS
550 TABLE 2308.7.5 REQUIRED RATING OF APPROVED UPLIFT CONNECTORS
551 TABLE 2308.7.1(1) CEILING JOIST SPANS FOR COMMON LUMBER SPECIES (Uninhabitable Attics Without Storage, Live Load = 10 psf, L/Δ = 240)
552 TABLE 2308.7.1(1)—continued CEILING JOIST SPANS FOR COMMON LUMBER SPECIES (Uninhabitable Attics Without Storage, Live Load = 10 psf, L/Δ = 240)
553 TABLE 2308.7.1(2) CEILING JOIST SPANS FOR COMMON LUMBER SPECIES (Uninhabitable Attics With Limited Storage, Live Load = 20 psf, L/Δ = 240)
554 TABLE 2308.7.1(2)—continued CEILING JOIST SPANS FOR COMMON LUMBER SPECIES (Uninhabitable Attics With Limited Storage, Live Load = 20 psf, L/Δ = 240)
555 TABLE 2308.7.2(1) RAFTER SPANS FOR COMMON LUMBER SPECIES (Roof Live Load = 20 psf, Ceiling Not Attached to Rafters, L/Δ = 180)
556 TABLE 2308.7.2(1)—continued RAFTER SPANS FOR COMMON LUMBER SPECIES (Roof Live Load = 20 psf, Ceiling Not Attached to Rafters, L/Δ = 180)
557 TABLE 2308.7.2(2) RAFTER SPANS FOR COMMON LUMBER SPECIES (Roof Live Load = 20 psf, Ceiling Attached to Rafters, L/Δ = 240)
558 TABLE 2308.7.2(2)—continued RAFTER SPANS FOR COMMON LUMBER SPECIES (Roof Live Load = 20 psf, Ceiling Attached to Rafters, L/Δ = 240)
559 TABLE 2308.7.2(3) RAFTER SPANS FOR COMMON LUMBER SPECIES (Ground Snow Load = 30 psf, Ceiling Not Attached to Rafters, L/Δ = 180)
560 TABLE 2308.7.2(3)—continued RAFTER SPANS FOR COMMON LUMBER SPECIES (Ground Snow Load = 30 psf, Ceiling Not Attached to Rafters, L/Δ = 180)
561 TABLE 2308.7.2(4) RAFTER SPANS FOR COMMON LUMBER SPECIES (Ground Snow Load = 50 psf, Ceiling Not Attached to Rafters, L/Δ = 180)
562 TABLE 2308.7.2(4) RAFTER SPANS FOR COMMON LUMBER SPECIES (Ground Snow Load = 50 psf, Ceiling Not Attached to Rafters, L/Δ = 180)
563 TABLE 2308.7.2(5) RAFTER SPANS FOR COMMON LUMBER SPECIES (Ground Snow Load = 30 psf, Ceiling Attached to Rafters, L/Δ = 240)
564 TABLE 2308.7.2(5)—continued RAFTER SPANS FOR COMMON LUMBER SPECIES (Ground Snow Load = 30 psf, Ceiling Attached to Rafters, L/Δ = 240)
565 TABLE 2308.7.2(6) RAFTER SPANS FOR COMMON LUMBER SPECIES (Ground Snow Load = 50 psf, Ceiling Attached to Rafters, L/Δ = 240)
566 TABLE 2308.7.2(6)—continued RAFTER SPANS FOR COMMON LUMBER SPECIES (Ground Snow Load = 50 psf, Ceiling Attached to Rafters, L/Δ = 240)
567 TABLE 2308.7.3.1 RAFTER TIE CONNECTIONSg
568 TABLE 2308.7.12 ALLOWABLE SPANS FOR 2-INCH TONGUE-AND-GROOVE DECKING
SECTION 2309 WOOD FRAME CONSTRUCTION MANUAL
569 TABLE 2308.7.12—continued ALLOWABLE SPANS FOR 2-INCH TONGUE-AND-GROOVE DECKING
570 CHAPTER 24: GLASS AND GLAZING
SECTION 2401 GENERAL
SECTION 2402 DEFINITIONS
SECTION 2403 GENERAL REQUIREMENTS FOR GLASS
SECTION 2404 WIND, SNOW, SEISMIC AND DEAD LOADS ON GLASS
EQUATION 24-1
EQUATION 24-2
EQUATION 24-3
571 EQUATION 24-4
EQUATION 24-5
EQUATION 24-6
EQUATION 24-7
EQUATION 24-8
EQUATION 24-9
EQUATION 24-10
EQUATION 24-11
EQUATION 24-12
572 SECTION 2405 SLOPED GLAZING AND SKYLIGHTS
573 EQUATION 24-13
EQUATION 24-14
EQUATION 24-15
SECTION 2406 SAFETY GLAZING
574 TABLE 2406.2(1) MINIMUM CATEGORY CLASSIFICATION OF GLAZING USING CPSC 16 CFR PART 1201
TABLE 2406.2(2) MINIMUM CATEGORY CLASSIFICATION OF GLAZING USING ANSI Z97.1
575 SECTION 2407 GLASS IN HANDRAILS AND GUARDS
SECTION 2408 GLAZING IN ATHLETIC FACILITIES
576 SECTION 2409 GLASS IN WALKWAYS, ELEVATOR HOISTWAYS AND ELEVATOR CARS
578 CHAPTER 25: GYPSUM BOARD, GYPSUM PANEL PRODUCTS AND PLASTER
SECTION 2501 GENERAL
SECTION 2502 DEFINITIONS
SECTION 2503 INSPECTION
SECTION 2504 VERTICAL AND HORIZONTAL ASSEMBLIES
SECTION 2505 SHEAR WALL CONSTRUCTION
SECTION 2506 GYPSUM BOARD AND GYPSUM PANEL PRODUCT MATERIALS
579 TABLE 2506.2 GYPSUM BOARD AND GYPSUM PANEL PRODUCTS MATERIALS AND ACCESSORIES
SECTION 2507 LATHING AND PLASTERING
TABLE 2507.2 LATH, PLASTERING MATERIALS AND ACCESSORIES
SECTION 2508 GYPSUM CONSTRUCTION
580 TABLE 2508.1 INSTALLATION OF GYPSUM CONSTRUCTION
TABLE 2508.5 SHEAR CAPACITY FOR HORIZONTAL WOOD-FRAME GYPSUM BOARD DIAPHRAGM CEILING ASSEMBLIES
581 SECTION 2509 SHOWERS AND WATER CLOSETS
TABLE 2509.2 BACKERBOARD MATERIALS
SECTION 2510 LATHING AND FURRING FOR CEMENT PLASTER (STUCCO)
SECTION 2511 INTERIOR PLASTER
582 TABLE 2511.1.1 INSTALLATION OF PLASTER CONSTRUCTION
SECTION 2512 EXTERIOR PLASTER
TABLE 2512.6 CEMENT PLASTERS
583 SECTION 2513 EXPOSED AGGREGATE PLASTER
SECTION 2514 REINFORCED GYPSUM CONCRETE
584 CHAPTER 26: PLASTIC
SECTION 2601 GENERAL
SECTION 2602 DEFINITIONS
SECTION 2603 FOAM PLASTIC INSULATION
587 FIGURE 2603.8 TERMITE INFESTATION PROBABILITY MAP
588 TABLE 2603.12.1 CLADDING MINIMUM FASTENING REQUIREMENTS FOR DIRECT ATTACHMENT OVER FOAM PLASTIC SHEATHING TO SUPPORT CLADDING WEIGH
589 TABLE 2603.12.2 FURRING MINIMUM FASTENING REQUIREMENTS FOR APPLICATION OVER FOAM PLASTIC SHEATHING TO SUPPORT CLADDING WEIGHTa
SECTION 2604 INTERIOR FINISH AND TRIM
590 SECTION 2605 PLASTIC VENEER
SECTION 2606 LIGHT-TRANSMITTING PLASTICS
591 SECTION 2607 LIGHT-TRANSMITTING PLASTIC WALL PANELS
TABLE 2607.4 AREA LIMITATION AND SEPARATION REQUIREMENTS FOR LIGHT-TRANSMITTING PLASTIC WALL PANELSa
592 SECTION 2608 LIGHT-TRANSMITTING PLASTIC GLAZING
SECTION 2609 LIGHT-TRANSMITTING PLASTIC ROOF PANELS
593 TABLE 2609.4 AREA LIMITATIONS FOR LIGHT-TRANSMITTING PLASTIC ROOF PANELS
SECTION 2610 LIGHT-TRANSMITTING PLASTIC SKYLIGHT GLAZING
SECTION 2611 LIGHT-TRANSMITTING PLASTIC INTERIOR SIGNS
594 SECTION 2612 PLASTIC COMPOSITES
SECTION 2613 FIBER-REINFORCED POLYMER
595 SECTION 2614 REFLECTIVE PLASTIC CORE INSULATION
596 CHAPTER 27: ELECTRICAL
SECTION 2701 GENERAL
SECTION 2702 EMERGENCY AND STANDBY POWER SYSTEMS
598 CHAPTER 28: MECHANICAL SYSTEMS
SECTION 2801 GENERAL
600 CHAPTER 29: PLUMBING SYSTEMS
SECTION 2901 GENERAL
SECTION 2902 MINIMUM PLUMBING FACILITIES
TABLE 2902.1 MINIMUM NUMBER OF REQUIRED PLUMBING FIXTURESa (See Sections 2902.1.1 and 2902.2)
601 TABLE 2902.1—(continued) MINIMUM NUMBER OF REQUIRED PLUMBING FIXTURESa (See Sections 2902.1.1 and 2902.2)
602 TABLE 2902.1—continued MINIMUM NUMBER OF REQUIRED PLUMBING FIXTURESa (See Sections 2902.1.1 and 2902.2)
604 CHAPTER 30: ELEVATORS AND CONVEYING SYSTEMS
SECTION 3001 GENERAL
SECTION 3002 HOISTWAY ENCLOSURES
605 SECTION 3003 EMERGENCY OPERATIONS
SECTION 3004 CONVEYING SYSTEMS
SECTION 3005 MACHINE ROOMS
606 SECTION 3006 ELEVATOR LOBBIES AND HOISTWAY OPENING PROTECTION
607 SECTION 3007 FIRE SERVICE ACCESS ELEVATOR
608 FIGURE 3007.6.5 FIRE SERVICE ACCESS ELEVATOR SYMBOL
SECTION 3008 OCCUPANT EVACUATION ELEVATORS
612 CHAPTER 31: SPECIAL CONSTRUCTION
SECTION 3101 GENERAL
SECTION 3102 MEMBRANE STRUCTURES
613 SECTION 3103 TEMPORARY STRUCTURES
SECTION 3104 PEDESTRIAN WALKWAYS AND TUNNELS
615 SECTION 3105 AWNINGS AND CANOPIES
SECTION 3106 MARQUEES
SECTION 3107 SIGNS
SECTION 3108 TELECOMMUNICATION AND BROADCAST TOWERS
616 SECTION 3109 SWIMMING POOL ENCLOSURES AND SAFETY DEVICES
617 SECTION 3110 AUTOMATIC VEHICULAR GATES
SECTION 3111 PHOTOVOLTAIC PANELS AND MODULES
618 CHAPTER 32: ENCROACHMENTS INTO THE PUBLIC RIGHT-OF-WAY
SECTION 3201 GENERAL
SECTION 3202 ENCROACHMENTS
620 CHAPTER 33: SAFEGUARDS DURING CONSTRUCTION
SECTION 3301 GENERAL
SECTION 3302 CONSTRUCTION SAFEGUARDS
SECTION 3303 DEMOLITION
SECTION 3304 SITE WORK
621 SECTION 3305 SANITARY
SECTION 3306 PROTECTION OF PEDESTRIANS
TABLE 3306.1 PROTECTION OF PEDESTRIANS
622 SECTION 3307 PROTECTION OF ADJOINING PROPERTY
SECTION 3308 TEMPORARY USE OF STREETS, ALLEYS AND PUBLIC PROPERTY
SECTION 3309 FIRE EXTINGUISHERS
SECTION 3310 MEANS OF EGRESS
SECTION 3311 STANDPIPES
623 SECTION 3312 AUTOMATIC SPRINKLER SYSTEM
SECTION 3313 WATER SUPPLY FOR FIRE PROTECTION
624 CHAPTER 34: RESERVED
626 CHAPTER 35: REFERENCED STANDARDS
AA
AAMA
ACI
627 AISC
AISI
ALI
628 AMCA
ANSI
APA
629 APSP
ASABE
ASCE/SEI
630 ASME
ASSE
ASTM
637 AWC
AWCI
AWPA
638 AWS
BHMA
CEN
CGSB
CPA
639 CPSC
CSA
CSSB
DASMA
640 DOC
DOL
DOTn
FEMA
641 FM
GA
HPVA
ICC
642 ISO
MHI
643 NAAMM
NCMA
NFPA
644 PCI
645 PTI
RMI
SBCA
SDI
SJI
646 SPRI
TIA
TMS
TPI
UL
648 ULC
USC
WCLIB
649 WDMA
WRI
650 APPENDIX A: EMPLOYEE QUALIFICATIONS
SECTION A101 BUILDING OFFICIAL QUALIFICATIONS
SECTION A102 REFERENCED STANDARDS
652 APPENDIX B: BOARD OF APPEALS
SECTION B101 GENERAL
654 APPENDIX C: GROUP U—AGRICULTURAL BUILDINGS
SECTION C101 GENERAL
SECTION C102 ALLOWABLE HEIGHT AND AREA
TABLE C102.1 BASIC ALLOWABLE AREA FOR A GROUP U, ONE STORY IN HEIGHT AND MAXIMUM HEIGHT OF SUCH OCCUPANCY
SECTION C103 MIXED OCCUPANCIES
SECTION C104 EXITS
656 APPENDIX D: FIRE DISTRICTS
SECTION D101 GENERAL
SECTION D102 BUILDING RESTRICTIONS
657 SECTION D103 CHANGES TO BUILDINGS
SECTION D104 BUILDINGS LOCATED PARTIALLY IN THE FIRE DISTRICT
SECTION D105 EXCEPTIONS TO RESTRICTIONS IN FIRE DISTRICT
658 SECTION D106 REFERENCED STANDARDS
660 APPENDIX E: SUPPLEMENTARY ACCESSIBILITY REQUIREMENTS
SECTION E101 GENERAL
SECTION E102 DEFINITIONS
SECTION E103 ACCESSIBLE ROUTE
SECTION E104 SPECIAL OCCUPANCIES
TABLE E104.2.1 DWELLING OR SLEEPING UNITS WITH ACCESSIBLE COMMUNICATION FEATURES
661 SECTION E105 OTHER FEATURES AND FACILITIES
SECTION E106 TELEPHONES
TABLE E106.2 WHEELCHAIR-ACCESSIBLE TELEPHONES
662 SECTION E107 SIGNAGE
SECTION E108 BUS STOPS
663 SECTION E109 TRANSPORTATION FACILITIES AND STATIONS
SECTION E110 AIRPORTS
664 SECTION E111 REFERENCED STANDARDS
666 APPENDIX F: RODENTPROOFING
SECTION F101 GENERAL
668 APPENDIX G: FLOOD-RESISTANT CONSTRUCTION
SECTION G101 ADMINISTRATION
SECTION G102 APPLICABILITY
SECTION G103 POWERS AND DUTIES
669 SECTION G104 PERMITS
670 SECTION G105 VARIANCES
671 SECTION G201 DEFINITIONS
SECTION G301 SUBDIVISIONS
SECTION G401 SITE IMPROVEMENT
672 SECTION G501 MANUFACTURED HOMES
SECTION G601 RECREATIONAL VEHICLES
SECTION G701 TANKS
SECTION G801 OTHER BUILDING WORK
673 SECTION G901 TEMPORARY STRUCTURES AND TEMPORARY STORAGE
SECTION G1001 UTILITY AND MISCELLANEOUS GROUP U
SECTION G1101 REFERENCED STANDARDS
674 APPENDIX H: SIGNS
SECTION H101 GENERAL
SECTION H102 DEFINITIONS
SECTION H103 LOCATION
SECTION H104 IDENTIFICATION
675 SECTION H105 DESIGN AND CONSTRUCTION
SECTION H106 ELECTRICAL
SECTION H107 COMBUSTIBLE MATERIALS
SECTION H108 ANIMATED DEVICES
SECTION H109 GROUND SIGNS
676 SECTION H110 ROOF SIGNS
SECTION H111 WALL SIGNS
SECTION H112 PROJECTING SIGNS
677 SECTION H113 MARQUEE SIGNS
SECTION H114 PORTABLE SIGNS
TABLE 4-A SIZE, THICKNESS AND TYPE OF GLASS PANELS IN SIGNS
TABLE 4-B THICKNESS OF PROJECTION SIGN
SECTION H115 REFERENCED STANDARDS
678 APPENDIX I: PATIO COVERS
SECTION I101 GENERAL
SECTION I102 DEFINITION
SECTION I103 EXTERIOR WALLS AND OPENINGS
SECTION I104 HEIGHT
SECTION I105 STRUCTURAL PROVISIONS
680 APPENDIX J: GRADING
SECTION J101 GENERAL
SECTION J102 DEFINITIONS
SECTION J103 PERMITS REQUIRED
SECTION J104 PERMIT APPLICATION AND SUBMITTALS
681 SECTION J105 INSPECTIONS
SECTION J106 EXCAVATIONS
SECTION J107 FILLS
SECTION J108 SETBACKS
682 FIGURE J107.3 BENCHING DETAILS
FIGURE J108.1 DRAINAGE DIMENSIONS
683 SECTION J109 DRAINAGE AND TERRACING
SECTION J110 EROSION CONTROL
SECTION J111 REFERENCED STANDARDS
684 APPENDIX K: ADMINISTRATIVE PROVISIONS
SECTION K101 GENERAL
SECTION K102 APPLICABILITY
SECTION K103 PERMITS
685 SECTION K104 CONSTRUCTION DOCUMENTS
SECTION K105 ALTERNATIVE ENGINEERED DESIGN
SECTION K106 REQUIRED INSPECTIONS
SECTION K107 PREFABRICATED CONSTRUCTION
686 SECTION K108 TESTING
SECTION K109 RECONNECTION
SECTION K110 CONDEMNING ELECTRICAL SYSTEMS
SECTION K111 ELECTRICAL PROVISIONS
688 APPENDIX L: EARTHQUAKE RECORDING INSTRUMENTATION
SECTION L101 GENERAL
690 APPENDIX M: TSUNAMI-GENERATED FLOOD HAZARD
SECTION M101 TSUNAMI-GENERATED FLOOD HAZARD
SECTION M102 REFERENCED STANDARDS
692 INDEX
ICC IBC 2015
$72.50