ICC SignificantChangestotheIBC 2012
$21.64
Significant Changes to the International Building Code, 2012 Edition
Published By | Publication Date | Number of Pages |
ICC | 2012 | 399 |
Full access to the most critical updates to the International Building Code
PDF Catalog
PDF Pages | PDF Title |
---|---|
1 | Cover |
4 | Contents |
14 | PART 1 Administration: Chapters 1 and 2 |
15 | 102.4 Conflicting Provisions between Codes and Standards |
16 | 104.10.1 Code Modifications for Flood Hazard Areas |
18 | 105.2, #B2 Fences Exempt from Permits |
19 | 202 Definitions |
21 | PART 2 Building Planning: Chapters 3 through 6 |
23 | 303.1.3 Assembly Rooms Associated with Group E Occupancies |
25 | 303.3 Occupancy Classification of Casino Gaming Floors |
27 | 303.3, 306.2 Occupancy Classification of Commercial Kitchens |
29 | Table 307.1(1), Section 307.4 Facilities Generating Combustible Dusts |
30 | 308.2, 202 Definitions of Care Facilities |
32 | 308.4 Occupancy Classification for Medical Care Facilities |
34 | 310.6 Uses Classified as Group R-4 Occupancies |
36 | 402 Open Mall Buildings |
38 | 403.6.1 High-Rise Buildings—Fire Service Access Elevators |
40 | 406.4 Public Parking Garages |
42 | 406.5.2.1 Open Parking Garages—Openings below Grade |
44 | 406.5.5 Open Parking Garages—Height and Area Increases |
46 | 410.6.3, 202 Technical Production Areas |
49 | 412.4.6.2 Aircraft Hangar Fire Areas |
51 | 414.5 Inside Storage, Dispensing, and Use of Hazardous Materials |
52 | 419, 202 Live/Work Units |
55 | 422 Ambulatory Care Facilities |
57 | 424 Children’s Play Structures |
60 | 501.2 Address Identification |
61 | 505.2.2 Mezzanine Means of Egress |
63 | 506.2.1 Allowable Area Frontage Increase |
66 | 507.1 Unlimited Area Buildings—Accessory Occupancies |
68 | 507.1 Unlimited Area Buildings—Open Space |
70 | 507.8 Unlimited Area Buildings—Group H Occupancies |
73 | 509 Incidental Uses—General Provisions |
75 | 509 Incidental Uses—Separation and Protection |
77 | Table 509 Incidental Uses—Rooms or Areas |
79 | Table 602, Note h: Fire Ratings of Exterior Walls |
81 | PART 3 Fire Protection: Chapters 7 through 9 |
83 | 701.2 Multiple-Use Fire Assemblies |
85 | 703.4 Establishing Fire Resistance Ratings |
86 | 703.7 Identification of Fire and Smoke Separation Walls |
88 | 704.11 Fire Protection of Bottom Flanges |
89 | 705.2 Extent of Projections beyond Exterior Walls |
91 | 705.2.3 Protection of Combustible Projections |
93 | 705.3 Projections from Buildings on the Same Lot |
95 | 706.2 Double Fire Walls |
97 | 706.6, 706.6.2 Fire Wall Height at Sloped Roofs |
99 | 707.8, 707.9 Intersections of Fire Barriers at Roof Assemblies |
101 | 709.4 Continuity of Smoke Barriers |
102 | 712 Vertical Openings |
104 | 713.13 Refuse and Laundry Chutes in Group I-2 Occupancies |
106 | 713.13.4 Fire Protection of Termination Rooms |
108 | 713.14.1 High-Rise Buildings—Elevator Lobbies |
111 | 714.4.1.1.2 Floor Penetrations of Horizontal Assemblies |
113 | 714.4.1.2 Interruption of Horizontal Assemblies |
115 | 714.5, 715.6, 202 L Ratings |
117 | 715.4 Exterior Curtain Wall/Floor Intersection |
119 | 716.3, 202 Marking of Fire-Rated Glazing Assemblies |
121 | Table 716.5 Opening Protection Ratings and Markings |
124 | 716.5.5.1 Glazing in Exit Enclosure and Exit Passageway Doors |
126 | Table 716.6 Fire-Protection-Rated Glazing |
128 | 716.6.4 Wired Glass in Fire Window Assemblies |
130 | 717.5.4 Fire Damper Exemption for Fire Partitions |
132 | 718.2.6 Fireblocking within Exterior Wall Coverings |
134 | 803.12 High-Density Polyethylene (HDPE) and Polypropylene (PP) |
135 | 804.4 Interior Floor Finish Requirements |
137 | 901.8 Pump and Riser Room Size |
138 | 903.2.2 Sprinklers in Ambulatory Care Facilities |
140 | 903.2.4, 903.2.7, 903.2.9 Furniture Storage and Display in Group F-1, M, and S-1 Occupancies |
142 | 903.2.11.1.3 Sprinkler Protection for Basements |
144 | 903.2.11.2 Sprinkler Protection of Rubbish and Linen Chutes |
147 | 903.3.5.2 Secondary Water Supply |
148 | 904.3.2 Actuation of Multiple Fire-Extinguishing Systems |
150 | 905.4 Location of Class I Standpipe Hose Connections |
152 | 906.1 Portable Fire Extinguishers in Group R-2 Occupancies |
153 | 907.2.1 Fire Alarms Systems in Group A Occupancies |
155 | 907.2.1.2 Emergency Voice/Alarm Communication Captions |
157 | 907.2.3 Group E Fire Alarm Systems |
159 | 907.2.9.3 Smoke Detection in Group R-2 College Buildings |
162 | 907.2.11.3 Wireless Interconnection of Smoke Alarms |
164 | 908.7 Carbon Monoxide Alarms |
166 | PART 4 Means of Egress: Chapter 10 |
168 | 1001.4 Fire Safety and Evacuation Plans |
170 | 1004.1.2, Table 1004.1.2 Design Occupant Load—Areas without Fixed Seating |
172 | 1005 Means of Egress Capacity Determination |
176 | 1007 Accessible Means of Egress |
180 | 1008.1.2 Door Swing |
181 | 1008.1.9.9 Electromagnetically Locked Egress Doors |
183 | 1009, 1010, 202 Interior Stairways and Ramps |
187 | 1009.1 Application of Stairway Provisions |
188 | 1011.2 Floor-Level Exit Signs in Group R-1 |
189 | 1012.2 Handrail Height |
191 | 1012.3.1, 1012.8 Handrail Graspability and Projections |
193 | 1013.1, 1013.8 Guards at Operable Windows |
196 | 1013.3 Guard Height |
198 | 1021.2 Exits from Stories |
200 | 1021.2.1 Exits from Mixed Occupancy Buildings |
201 | 1021.2.3, Table 1021.2(1) Exits from Dwelling Units |
205 | 1022.5 Enclosure Penetrations of Interior Exit Stairways |
207 | 1028.1.1.1 Separation of Spaces under Grandstands and Bleachers |
208 | PART 5 Accessibility: Chapter 11 |
209 | 1104.3.1 Employee Work Areas |
211 | 1107.6.1 Accessible Units in R-1 Occupancies |
213 | 1108.2.7.3 Captioning of Public Address Announcements |
215 | 1109.2, 1109.5 Accessible Children’s Facilities |
218 | 1109.6 Accessible Saunas and Steam Rooms |
219 | 1110.4 Variable Message Signs |
222 | PART 6 Building Envelope, Structural Systems, and Construction Materials: Chapters 12 through 26 |
225 | 1203.1 Mechanical Ventilation Required |
227 | 1203.2 Ventilation of Attic Spaces |
229 | 1208.3 Minimum Kitchen Floor Area |
230 | 1210 Toilet and Bathroom Requirements |
233 | 1403.5 Flame Propagation at Exterior Walls |
235 | 1404.12, 1405.18, 202 Polypropylene Siding |
237 | 1405.6 Anchored Masonry Veneer |
238 | 1503.4 Roof Drainage Systems |
240 | 1507.2.8.1 Roof Covering Underlayment in High Wind Areas |
242 | 1507.16 Roof Gardens and Landscaped Roofs |
244 | 1507.17, 3111, 202 Photovoltaic Systems |
246 | 1509, 202 Rooftop Structures |
253 | 1510.3 Roof Covering Replacement |
255 | Table 1604.3 Deflection Limits |
256 | 1604.5, 202 Risk Categories |
259 | 1605.2 Load Combinations Using Strength Design of Load and Resistance Factor Design |
261 | 1605.3 Load Combinations Using Allowable Stress Design |
264 | Table 1607.1 Minimum Live Loads |
268 | 1607.6, 202 Helipads |
270 | 1607.7 Heavy Vehicle Loads |
272 | 1608.3, 1611.2, 202 Ponding Instability |
273 | 1609, 202 Determination of Wind Loads |
283 | 1613.3.1, 202 Mapped Acceleration Parameters |
289 | 1613.4 Alternatives to ASCE 7 |
293 | 1614, 202 Atmospheric Ice Loads |
294 | 1704.3 Statement of Special Inspections |
298 | 1705.2 Special Inspection of Steel Construction |
302 | Table 1705.3 Required Verification and Inspection of Concrete Construction |
304 | 1705.4 Special Inspection of Masonry Construction |
306 | 1705.16 Special Inspection of Fire-Resistant Penetration and Joint Systems |
307 | 1803.5.12 Geotechnical Reports for Foundation Walls and Retaining Walls |
308 | 1810.3.3.1.6 Uplift Capacity of Grouped Deep Foundation Elements |
309 | Chapter 19 Concrete Construction |
313 | 1905.1.3 Seismic Detailing of Wall Piers |
315 | 1905.1.8 Plain Concrete Footings in Dwelling Construction |
317 | 1905.1.9 Shear Wall to Concrete Foundation Connection |
321 | 2101.2 Design Methods for Masonry Structures |
322 | 2206 Composite Structural Steel and Concrete Structures |
324 | 2210.2 Seismic Requirements for Cold-Formed Steel Structures |
326 | 2305 General Design Requirements for Lateral-Force-Resisting Systems |
328 | 2306 Allowable Stress Design |
332 | 2307 Load and Resistance Factor Design |
334 | 2308.12 Braced Wall Line Sheathing |
337 | 2406.1, 2406.4 Safety Glazing—Hazardous Locations |
343 | 2406.2 Safety Glazing—Impact Test |
345 | 2510.6 Water-Resistive Barriers for Stucco Applications |
347 | 2603.4.1.14 Foam Plastic Insulation Installed in Floor Assemblies |
349 | 2603.7, 2603.8 Interior Finish in Plenums |
351 | 2603.10, 2603.10.1 Special Approval of Foam Plastics |
353 | 2610.3 Slope Requirements of a Dome Skylight |
355 | 2612, 202 Fiber-Reinforced Polymer |
359 | PART 7 Building Services, Special Devices, and Special Conditions: Chapters 27 through 34 |
360 | 2902.2 Single-User Toilet Facilities |
362 | 2902.3 Toilet Facilities in Parking Garages |
363 | 2902.3.5 Locking of Toilet Room Doors |
364 | 2902.5 Required Drinking Fountains |
365 | 3007 Fire Service Access Elevators |
370 | 3008 Occupant Evacuation Elevators |
374 | 3108 Telecommunication and Broadcast Towers |
375 | 3302.3, 3303.7, 3313 Fire Safety during Construction |
377 | 3401.3 Compliance for Existing Buildings |
379 | 3411 Type B Units in Existing Buildings |
384 | Appendix L: Earthquake-Recording Instruments |
386 | Appendix M: Tsunami-Generated Flood Hazards |
388 | Index A B C |
389 | D E F |
390 | G |
391 | H I J K L M |
392 | N O P R S |
393 | T U V W |