IEEE C37.011-2019(Redline)

$118.63

IEEE Guide for the Application of Transient Recovery Voltage for AC High-Voltage Circuit Breakers with Rated Maximum Voltage above 1000 V (Redline)

Published By Publication Date Number of Pages
IEEE 2019
Guaranteed Safe Checkout
Category:

If you have any questions, feel free to reach out to our online customer service team by clicking on the bottom right corner. We’re here to assist you 24/7.
Email:[email protected]

Revision Standard – Active. The procedures and calculations necessary to apply the standard transient recovery voltage (TRV) ratings for ac high-voltage circuit breakers rated above 1000 V are covered in this guide. The breaking capability limits of these circuit breakers are determined to a great degree by the TRV. The TRV ratings are compared with typical system TRV duties. Examples of TRV calculation are given with suggested options if the TRV duty exceeds the TRV ratings of the circuit breaker.

PDF Catalog

PDF Pages PDF Title
1 IEEE Std C37.011™-2019 Front cover
2 Title page
4 Important Notices and Disclaimers Concerning IEEE Standards Documents
7 Participants
9 Introduction
10 Contents
11 List of Figures
14 List of Tables
15 IMPORTANT NOTICE
1. Overview
1.1 Scope
1.2 Purpose
2. Normative references
16 3. Transient recovery voltage
3.1 General
17 3.2 Arc-circuit interaction
18 3.3 Method of rating and application
29 4. Application considerations
4.1 General
32 4.2 Circuit breaker capability
62 4.3 Exponential (overdamped) TRV
64 4.4 Oscillatory (underdamped) TRV
75 4.5 Application where circuit breaker capability may be exceeded
79 5. Testing issues
5.1 General
80 5.2 Application of TRV test data to a multi-break interrupter
82 Annex A (informative) Transient recovery voltage (TRV) calculation techniques
A.1 Typical system for TRV calculation
83 A.2 Transient recovery voltage types
93 A.3 Equivalent circuit representation
98 A.4 Example of transient recovery voltage calculation
104 Annex B (informative) Typical capacitance values for various equipment
111 Annex C (informative) Selection of the first-pole-to-clear factors and factors for second and third poles to clear
C.1 Selection of the first-pole-to-clear factor
C.2 Factors for each pole to clear
116 Annex D (informative) Guidance for transient recovery voltage (TRV) calculation by electromagnetic transients program
D.1 General
D.2 Transformer-fed and transformer-limited fault
D.3 Current-limiting reactor-limited fault
117 D.4 Short-line fault (SLF)
119 D.5 General station model
121 D.6 Calculation of circuit breaker TRV and rate-of-rise-of-recovery voltage (RRRV)
123 Annex E (informative) Abbreviations
124 Annex F (informative) (Bibliography)
127 Back cover
IEEE C37.011-2019
$118.63