IEEE C57.12.01 1979

$23.29

Dry-Type Transformers Incorporating Solid Cast and/or Resin-Encapsulated Windings

Published By Publication Date Number of Pages
IEEE 1979 32
Guaranteed Safe Checkout
Category:

If you have any questions, feel free to reach out to our online customer service team by clicking on the bottom right corner. Weā€™re here to assist you 24/7.
Email:[email protected]

New IEEE Standard – Inactive – Superseded. Superseded. Electrical, mechanical, and safety requirements of ventilated, nonventilated, and sealed dry-type distribution and power transformers or autotransformers, single and polyphase, with a voltage of 601 V or higher in the highest voltage winding, are described. Information that can be used as a basis for the establishment of performance, interchangeability, and safety requirements of equipment described, and for assistance in the proper selection of such equipment, is given.

PDF Catalog

PDF Pages PDF Title
9 1 Scope
2 Terminology
3 References
3.1 Standards References
10 3.2 Applicable Documents in Preparation
4 Serviceconditions
4.1 Usual Service Conditions
4.2 Unusual Service Conditions
11 Table 1 Dielectric-Strength Correction Factors for Altitudes Greater than 3300 ft (1000 m)
12 5 RatingData
Cooling Classes of Transformers
5.2 Frequency
5.3 Phases
5.4 RatedkVA
Table 2 Preferred Continuous kVA Ratings
13 5.6 Connections
Polarity Angular Displacement and Terminal Markings
5.8 Impedance
5.9 Losses
Fig 1 Phase Relation of Terminal Designations for Three-phase Transformers
14 5.10 Insulation Levels
Table 3 Insulation Levels for Dry-Type Transformers
15 Temperature Rise and Insulation-System Capability
16 Table 4 Limits of Temperature Rise for Continuously Rated Transformers
17 5.12 Nameplates
18 Table 5 Nameplate Information
19 Fig 2 Designation of Voltage Ratings of Single- and Three-phase Windings
21 6 Construction
6.1 Tank-Pressure Requirements
6.2 Finish
6.3 Transformer Accessories
6.4 Terminals
6.5 Grounding
Sh ort-Circuit Characteris tics
7.1 Short-circuit Requirements
7.2 Transformer Categories
22 Short-Circuit-Current Duration and Magnitude
23 System Zero-Sequence Data
Application Conditions Requiring Special Consideration
7.6 Components
Table6 ValuesofK
24 Base BVA and Base Currents
Effects of Temperature on Transformer Windings During Short-circuit Conditions
Calculation of Winding Temperature During a Short Circuit
25 Testing and Calculations
8.1 General
8.2 Test Classifications
Routine Design and Other Tests
8.4 Calculations
9 Tolerances
9.1 Ratio
9.2 Impedance
26 9.3 Losses
Table 7 Dry-Type Transformer Tests
Table 8 Tolerances for Single-phase and Three-phase Transformer Losses
27 Connection of Transformers for Shipment
29 Unusual Temperature and Altitude Conditions
A1 Unusual Temperature and Altitude Service Conditions
A2 Effect of Altitude on Temperature Rise
A3 Operation at Rated kVA
A4 Operation at Less than Rated kVA
Table A1 Maximum 24H Average Temperature of Cooling Air
Table A2 Rated kVA Derating Factors for Altitudes Greater than 3300 ft (1000 m)