ISO 1694:1976

$13.00

Cryolite, natural and artificial — Determination of iron content — 1,10- Phenanthroline photometric method

Published By Publication Date Number of Pages
ISO 1976-09 7
Guaranteed Safe Checkout
Categories: ,

If you have any questions, feel free to reach out to our online customer service team by clicking on the bottom right corner. We’re here to assist you 24/7.
Email:[email protected]

Applies for the determination of natural and synthetic materials having a molar ratio sodium fluoride/aluminium trifluoride between 3 and 1,7 approximately. The method is applicable to products having an iron content equal to or greater than 0,020 % (m/m). The principle consists in dissolution of a test portion by either alkaline or acid fusion. Reduction of iron(III) with hydroxylammonium chloride, formation of the complex iron(II)-1, 10-phenathroline in a buffered medium at pH value between 3,5 and 4,2. Photometric measurement of the coloured complex at a wavelength of about 510 nm. Applies ISO Recommendation R 1694-1970.

ISO 1694:1976