Shopping Cart

No products in the cart.

ISO 2829:1973

$13.00

Aluminium oxide primarily used for the production of aluminium — Determination of phosphorus content — Reduced phosphomolybdate spectrophotometric method

Published By Publication Date Number of Pages
ISO 1973-12 5
Guaranteed Safe Checkout
Categories: ,

If you have any questions, feel free to reach out to our online customer service team by clicking on the bottom right corner. We’re here to assist you 24/7.
Email:[email protected]

Applicable to products having phosphorus contents of more than 0.0005 % (m/m). Preparation of a solution from a test portion by alkaline fusion either with a mixture of sodium carbonate and borid or of sodium carbonate and sodium tetraborate. Dissolution of the cooled molten mass in nitric acid and adjustment of an appropriate aliquot portion to pH 2. Formation of a phosphomolybdic complex and extraction by 2-methylpropan-1-ol in a sulphuric acid medium. Reduction of the complex by thin(II) chloride in the organic phase and spectrophotometric measurement of the reduced complex at a wavelength of about 730 nm. Has also been approved by the IUPAC.

ISO 2829:1973