Shopping Cart

No products in the cart.

NY EnergyCode 10:2010 Edition

$18.69

Energy Conservation Construction Code of New York State

Published By Publication Date Number of Pages
NY 2010 74
Guaranteed Safe Checkout
Category:

If you have any questions, feel free to reach out to our online customer service team by clicking on the bottom right corner. We’re here to assist you 24/7.
Email:[email protected]

 A fully integrated custom code based on the 2009 International Energy Conservation Code® (IECC®). Encourages energy conservation through efficiency in envelope design, mechanical systems, lighting systems and the use of new materials and techniques.

Features:

  • Time-tested safety concepts
  • Innovative construction technology

PDF Catalog

PDF Pages PDF Title
1 2010 ENERGY CONSERVATION CONSTRUCTION CODE OF NEW YORK STATE
2 COPYRIGHT
3 ACKNOWLEDGMENTS
STATE FIRE PREVENTION AND BUILDING CODE COUNCIL
DEPARTMENT OF STATE
ENERGY CONSERVATION CONSTRUCTION CODE TECHNICAL SUBCOMMITTEE
4 CONTENT
MARGINAL MARKINGS
LETTER DESIGNATIONS IN FRONT OF SECTION NUMBERS
5 TABLE OF CONTENTS
7 CHAPTER 1 GENERAL REQUIREMENTS
SECTION 101 SCOPE AND GENERAL REQUIREMENTS
9 SECTION 102 ALTERNATE MATERIALS—METHOD OF CONSTRUCTION, DESIGN OR INSULATING SYSTEMS
SECTION 103 CONSTRUCTION DOCUMENTS
10 SECTION 104 INSPECTIONS
SECTION 105 INTERPRETATION OF CODE REQUIREMENTS
11 SECTION 106 VALIDITY
SECTION 107 REFERENCED STANDARDS
13 CHAPTER 2 DEFINITIONS
SECTION 201 GENERAL
SECTION 202 GENERAL DEFINITIONS
17 CHAPTER 3 CLIMATE ZONES, DESIGN CONDITIONS, MATERIALS, EQUIPMENT AND SYSTEMS
SECTION 301 CLIMATE ZONES
TABLE 301.1 CLIMATE ZONES BY COUNTY, ALL ZONES ARE CATEGORY “A” OR, MOIST DESIGNATIONS
SECTION 302 DESIGN CONDITIONS
SECTION 303 MATERIALS, SYSTEMS AND EQUIPMENT
TABLE 303.1.3(1) DEFAULT GLAZED FENESTRATION U-FACTORS
18 TABLE 303.1.3(2) DEFAULT DOOR U-FACTORS
TABLE 303.1.3(3) DEFAULT GLAZED FENESTRATION SHGC
19 CHAPTER 4 RESIDENTIAL ENERGY EFFICIENCY
SECTION 401 GENERAL
SECTION 402 BUILDING THERMAL ENVELOPE
TABLE 402.1.1 INSULATION AND FENESTRATION REQUIREMENTS BY COMPONENTa
20 TABLE 402.1.3 EQUIVALENT U-FACTORSa
TABLE 402.1.5.1 SIDING MINIMUM FASTENING REQUIREMENTS FOR DIRECT SIDING ATTACHMENT OVER FOAM PLASTIC SHEATHING TO SUPPORT SIDING WEIGHT1
21 TABLE 402.1.5.2 FURRING MINIMUM FASTENING REQUIREMENTS FOR APPLICATION OVER FOAM PLASTIC SHEATHING TO SUPPORT SIDING WEIGHT1,2
22 TABLE 402.2.1.1 INSULATION FOR CONDENSATION CONTROL
23 TABLE 402.2.5 STEEL-FRAME CEILING, WALL AND FLOOR INSULATION (R-VALUE)
25 TABLE 402.4.2 AIR BARRIER AND INSULATION INSPECTION COMPONENT CRITERIA
26 TABLE 402.5.1 CLASS III VAPOR RETARDERS1
SECTION 403 SYSTEMS (Mandatory)
27 SECTION 404 ELECTRICAL POWER AND LIGHTING SYSTEMS
28 SECTION 405 SIMULATED PERFORMANCE ALTERNATIVE (Performance)
29 TABLE 405.5.2(1) SPECIFICATIONS FOR THE STANDARD REFERENCE AND PROPOSED DESIGNS
30 TABLE 405.5.2(1)—continued SPECIFICATIONS FOR THE STANDARD REFERENCE AND PROPOSED DESIGNS
31 TABLE 405.5.2(1)—continued
TABLE 405.5.2(2) DEFAULT DISTRIBUTION SYSTEM EFFICIENCIES FOR PROPOSED DESIGNSa
33 CHAPTER 5 COMMERCIAL ENERGY EFFICIENCY
SECTION 501 GENERAL
SECTION 502 BUILDING ENVELOPE REQUIREMENTS
TABLE 502.1.2 BUILDING ENVELOPE REQUIREMENTS – OPAQUE ELEMENT, MAXIMUM U-FACTORS
34 TABLE 502.2(1) BUILDING ENVELOPE REQUIREMENTS – OPAQUE ASSEMBLIES
35 TABLE 502.2(2) BUILDING ENVELOPE REQUIREMENTS–OPAQUE ASSEMBLIES
36 TABLE 502.2.8.1 SIDING MINIMUM FASTENING REQUIREMENTS FOR DIRECT SIDING ATTACHMENT OVER FOAM PLASTIC SHEATHING TO SUPPORT SIDING DEAD LOAD1
37 TABLE 502.2.8.2 FURRING MINIMUM FASTENING REQUIREMENTS FOR APPLICATION OVER FOAM PLASTIC SHEATHING TO SUPPORT SIDING DEAD LOAD1,2
38 TABLE 502.3 BUILDING ENVELOPE REQUIREMENTS: FENESTRATION
EQUATION 5-1
39 TABLE 502.5.1 CLASS III VAPOR RETARDERS
40 SECTION 503 BUILDING MECHANICAL SYSTEMS
41 TABLE 503.2.3(1) UNITARY AIR CONDITIONERS AND CONDENSING UNITS, ELECTRICALLY OPERATED, MINIMUM EFFICIENCY REQUIREMENTS
42 TABLE 503.2.3(2) UNITARY AND APPLIED HEAT PUMPS, ELECTRICALLY OPERATED, MINIMUM EFFICIENCY REQUIREMENTS
43 TABLE 503.2.3(3) PACKAGED TERMINAL AIR CONDITIONERS AND PACKAGED TERMINAL HEAT PUMPS
TABLE 503.2.3(4) WARM AIR FURNACES AND COMBINATION WARM AIR FURNACES/AIR-CONDITIONING UNITS, WARM AIR DUCT FURNACES AND UNIT HEATERS, MINIMUM EFFICIENCY REQUIREMENTS
44 TABLE 503.2.3(5) BOILERS, GAS- AND OIL-FIRED, MINIMUM EFFICIENCY REQUIREMENTS
TABLE 503.2.3(6) CONDENSING UNITS, ELECTRICALLY OPERATED, MINIMUM EFFICIENCY REQUIREMENTS
45 TABLE 503.2.3(7) WATER CHILLING PACKAGES, MINIMUM REQUIREMENTSa
46 EQUATION 5-2
TABLE 503.2.8 MINIMUM PIPE INSULATIONa, b (thickness in inches)
47 TABLE 503.2.10.1(1) FAN POWER LIMITATION
48 TABLE 503.2.10.1(2) FAN POWER LIMITATION PRESSURE DROP ADJUSTMENT
TABLE 503.3.1(1) ECONOMIZER REQUIREMENTS
51 TABLE 503.4.7 MAXIMUM HOT GAS BYPASS CAPACITY
SECTION 504 SERVICE WATER HEATING (Mandatory)
SECTION 505 ELECTRICAL POWER AND LIGHTING SYSTEMS
52 TABLE 504.2 MINIMUM PERFORMANCE OF WATER HEATING EQUIPMENT
55 TABLE 505.5.2 INTERIOR LIGHTING POWER ALLOWANCES
TABLE 505.5.2—continued INTERIOR LIGHTING POWER ALLOWANCES
56 TABLE 505.6.2(1) EXTERIOR LIGHTING ZONES
TABLE 505.6.2(2) INDIVIDUAL LIGHTING POWER ALLOWANCES FOR BUILDING EXTERIORS
SECTION 506 TOTAL BUILDING PERFORMANCE
57 TABLE 505.6.2(2)—continued INDIVIDUAL LIGHTING POWER ALLOWANCES FOR BUILDING EXTERIORS
58 TABLE 506.5.1(1) SPECIFICATIONS FOR THE STANDARD REFERENCE AND PROPOSED DESIGNS
59 TABLE 506.5.1(1)—continued SPECIFICATIONS FOR THE STANDARD REFERENCE AND PROPOSED DESIGNS
60 TABLE 506.5.1(2) HVAC SYSTEMS MAP
TABLE 506.5.1(3) SPECIFICATIONS FOR THE STANDARD REFERENCE DESIGN HVAC SYSTEM DESCRIPTIONS
61 TABLE 506.5.1(4) NUMBER OF CHILLERS
TABLE 506.5.1(5) WATER CHILLER TYPES
63 CHAPTER 6 REFERENCED STANDARDS
AAMA
ACCA
AFPA
AHRI
64 AISI
AMCA
ANSI
ASHRAE
65 ASME
ASTM
CSA
DOE
66 ICC
IESNA
NFRC
67 SMACNA
UL
US FTC
WDMA
69 INDEX
74 HELPFUL LINKS
NY EnergyCode 10
$18.69