NY EnergyCode 10:2010 Edition
$18.69
Energy Conservation Construction Code of New York State
Published By | Publication Date | Number of Pages |
NY | 2010 | 74 |
A fully integrated custom code based on the 2009 International Energy Conservation Code® (IECC®). Encourages energy conservation through efficiency in envelope design, mechanical systems, lighting systems and the use of new materials and techniques.
Features:
- Time-tested safety concepts
- Innovative construction technology
PDF Catalog
PDF Pages | PDF Title |
---|---|
1 | 2010 ENERGY CONSERVATION CONSTRUCTION CODE OF NEW YORK STATE |
2 | COPYRIGHT |
3 | ACKNOWLEDGMENTS STATE FIRE PREVENTION AND BUILDING CODE COUNCIL DEPARTMENT OF STATE ENERGY CONSERVATION CONSTRUCTION CODE TECHNICAL SUBCOMMITTEE |
4 | CONTENT MARGINAL MARKINGS LETTER DESIGNATIONS IN FRONT OF SECTION NUMBERS |
5 | TABLE OF CONTENTS |
7 | CHAPTER 1 GENERAL REQUIREMENTS SECTION 101 SCOPE AND GENERAL REQUIREMENTS |
9 | SECTION 102 ALTERNATE MATERIALS—METHOD OF CONSTRUCTION, DESIGN OR INSULATING SYSTEMS SECTION 103 CONSTRUCTION DOCUMENTS |
10 | SECTION 104 INSPECTIONS SECTION 105 INTERPRETATION OF CODE REQUIREMENTS |
11 | SECTION 106 VALIDITY SECTION 107 REFERENCED STANDARDS |
13 | CHAPTER 2 DEFINITIONS SECTION 201 GENERAL SECTION 202 GENERAL DEFINITIONS |
17 | CHAPTER 3 CLIMATE ZONES, DESIGN CONDITIONS, MATERIALS, EQUIPMENT AND SYSTEMS SECTION 301 CLIMATE ZONES TABLE 301.1 CLIMATE ZONES BY COUNTY, ALL ZONES ARE CATEGORY “A” OR, MOIST DESIGNATIONS SECTION 302 DESIGN CONDITIONS SECTION 303 MATERIALS, SYSTEMS AND EQUIPMENT TABLE 303.1.3(1) DEFAULT GLAZED FENESTRATION U-FACTORS |
18 | TABLE 303.1.3(2) DEFAULT DOOR U-FACTORS TABLE 303.1.3(3) DEFAULT GLAZED FENESTRATION SHGC |
19 | CHAPTER 4 RESIDENTIAL ENERGY EFFICIENCY SECTION 401 GENERAL SECTION 402 BUILDING THERMAL ENVELOPE TABLE 402.1.1 INSULATION AND FENESTRATION REQUIREMENTS BY COMPONENTa |
20 | TABLE 402.1.3 EQUIVALENT U-FACTORSa TABLE 402.1.5.1 SIDING MINIMUM FASTENING REQUIREMENTS FOR DIRECT SIDING ATTACHMENT OVER FOAM PLASTIC SHEATHING TO SUPPORT SIDING WEIGHT1 |
21 | TABLE 402.1.5.2 FURRING MINIMUM FASTENING REQUIREMENTS FOR APPLICATION OVER FOAM PLASTIC SHEATHING TO SUPPORT SIDING WEIGHT1,2 |
22 | TABLE 402.2.1.1 INSULATION FOR CONDENSATION CONTROL |
23 | TABLE 402.2.5 STEEL-FRAME CEILING, WALL AND FLOOR INSULATION (R-VALUE) |
25 | TABLE 402.4.2 AIR BARRIER AND INSULATION INSPECTION COMPONENT CRITERIA |
26 | TABLE 402.5.1 CLASS III VAPOR RETARDERS1 SECTION 403 SYSTEMS (Mandatory) |
27 | SECTION 404 ELECTRICAL POWER AND LIGHTING SYSTEMS |
28 | SECTION 405 SIMULATED PERFORMANCE ALTERNATIVE (Performance) |
29 | TABLE 405.5.2(1) SPECIFICATIONS FOR THE STANDARD REFERENCE AND PROPOSED DESIGNS |
30 | TABLE 405.5.2(1)—continued SPECIFICATIONS FOR THE STANDARD REFERENCE AND PROPOSED DESIGNS |
31 | TABLE 405.5.2(1)—continued TABLE 405.5.2(2) DEFAULT DISTRIBUTION SYSTEM EFFICIENCIES FOR PROPOSED DESIGNSa |
33 | CHAPTER 5 COMMERCIAL ENERGY EFFICIENCY SECTION 501 GENERAL SECTION 502 BUILDING ENVELOPE REQUIREMENTS TABLE 502.1.2 BUILDING ENVELOPE REQUIREMENTS – OPAQUE ELEMENT, MAXIMUM U-FACTORS |
34 | TABLE 502.2(1) BUILDING ENVELOPE REQUIREMENTS – OPAQUE ASSEMBLIES |
35 | TABLE 502.2(2) BUILDING ENVELOPE REQUIREMENTS–OPAQUE ASSEMBLIES |
36 | TABLE 502.2.8.1 SIDING MINIMUM FASTENING REQUIREMENTS FOR DIRECT SIDING ATTACHMENT OVER FOAM PLASTIC SHEATHING TO SUPPORT SIDING DEAD LOAD1 |
37 | TABLE 502.2.8.2 FURRING MINIMUM FASTENING REQUIREMENTS FOR APPLICATION OVER FOAM PLASTIC SHEATHING TO SUPPORT SIDING DEAD LOAD1,2 |
38 | TABLE 502.3 BUILDING ENVELOPE REQUIREMENTS: FENESTRATION EQUATION 5-1 |
39 | TABLE 502.5.1 CLASS III VAPOR RETARDERS |
40 | SECTION 503 BUILDING MECHANICAL SYSTEMS |
41 | TABLE 503.2.3(1) UNITARY AIR CONDITIONERS AND CONDENSING UNITS, ELECTRICALLY OPERATED, MINIMUM EFFICIENCY REQUIREMENTS |
42 | TABLE 503.2.3(2) UNITARY AND APPLIED HEAT PUMPS, ELECTRICALLY OPERATED, MINIMUM EFFICIENCY REQUIREMENTS |
43 | TABLE 503.2.3(3) PACKAGED TERMINAL AIR CONDITIONERS AND PACKAGED TERMINAL HEAT PUMPS TABLE 503.2.3(4) WARM AIR FURNACES AND COMBINATION WARM AIR FURNACES/AIR-CONDITIONING UNITS, WARM AIR DUCT FURNACES AND UNIT HEATERS, MINIMUM EFFICIENCY REQUIREMENTS |
44 | TABLE 503.2.3(5) BOILERS, GAS- AND OIL-FIRED, MINIMUM EFFICIENCY REQUIREMENTS TABLE 503.2.3(6) CONDENSING UNITS, ELECTRICALLY OPERATED, MINIMUM EFFICIENCY REQUIREMENTS |
45 | TABLE 503.2.3(7) WATER CHILLING PACKAGES, MINIMUM REQUIREMENTSa |
46 | EQUATION 5-2 TABLE 503.2.8 MINIMUM PIPE INSULATIONa, b (thickness in inches) |
47 | TABLE 503.2.10.1(1) FAN POWER LIMITATION |
48 | TABLE 503.2.10.1(2) FAN POWER LIMITATION PRESSURE DROP ADJUSTMENT TABLE 503.3.1(1) ECONOMIZER REQUIREMENTS |
51 | TABLE 503.4.7 MAXIMUM HOT GAS BYPASS CAPACITY SECTION 504 SERVICE WATER HEATING (Mandatory) SECTION 505 ELECTRICAL POWER AND LIGHTING SYSTEMS |
52 | TABLE 504.2 MINIMUM PERFORMANCE OF WATER HEATING EQUIPMENT |
55 | TABLE 505.5.2 INTERIOR LIGHTING POWER ALLOWANCES TABLE 505.5.2—continued INTERIOR LIGHTING POWER ALLOWANCES |
56 | TABLE 505.6.2(1) EXTERIOR LIGHTING ZONES TABLE 505.6.2(2) INDIVIDUAL LIGHTING POWER ALLOWANCES FOR BUILDING EXTERIORS SECTION 506 TOTAL BUILDING PERFORMANCE |
57 | TABLE 505.6.2(2)—continued INDIVIDUAL LIGHTING POWER ALLOWANCES FOR BUILDING EXTERIORS |
58 | TABLE 506.5.1(1) SPECIFICATIONS FOR THE STANDARD REFERENCE AND PROPOSED DESIGNS |
59 | TABLE 506.5.1(1)—continued SPECIFICATIONS FOR THE STANDARD REFERENCE AND PROPOSED DESIGNS |
60 | TABLE 506.5.1(2) HVAC SYSTEMS MAP TABLE 506.5.1(3) SPECIFICATIONS FOR THE STANDARD REFERENCE DESIGN HVAC SYSTEM DESCRIPTIONS |
61 | TABLE 506.5.1(4) NUMBER OF CHILLERS TABLE 506.5.1(5) WATER CHILLER TYPES |
63 | CHAPTER 6 REFERENCED STANDARDS AAMA ACCA AFPA AHRI |
64 | AISI AMCA ANSI ASHRAE |
65 | ASME ASTM CSA DOE |
66 | ICC IESNA NFRC |
67 | SMACNA UL US FTC WDMA |
69 | INDEX |
74 | HELPFUL LINKS |