OH PlumbingCode 2011
$51.46
Ohio Plumbing Code
Published By | Publication Date | Number of Pages |
OH | 2011 | 148 |
This is a fully integrated code based on the 2009 IPC.
PDF Catalog
PDF Pages | PDF Title |
---|---|
1 | 2011 OHIO PLUMBING CODE |
2 | COPYRIGHT |
3 | PREFACE |
5 | TABLE OF CONTENTS |
7 | CHAPTER 1: SCOPE AND ADMINISTRATION PART 1—SCOPE AND APPLICATION SECTION 101 GENERAL CHAPTER 1 OF THE 2011 OHIO BUILDING CODEUSE AS REFERENCE FOR THIS CODE ONLY(PROVIDED AS A CONVENIENCE FOR CODE USERS) SECTION 101 GENERAL |
8 | SECTION 102 APPLICABILITY AND JURISDICTIONAL AUTHORITY |
11 | SECTION 103 CERTIFIED BUILDING DEPARTMENTS, PERSONNEL, AND APPEALS BOARDS |
25 | SECTION 104 DUTIES AND RESPONSIBILITIES |
27 | SECTION 105 APPROVALS |
28 | SECTION 106 CONSTRUCTION DOCUMENTS |
32 | SECTION 107 PLAN APPROVAL PROCESS |
33 | SECTION 108 INSPECTION PROCESS |
35 | SECTION 109 ORDERS, VIOLATIONS, AND UNSAFE BUILDINGS |
36 | SECTION 110 APPEALS |
37 | SECTION 111 CERTIFICATE OF OCCUPANCY |
38 | SECTION 112 CHANGES TO THE CODE SECTION 113 INDUSTRIALIZED UNITS |
40 | SECTION 114 PRODUCTS AND MATERIALS |
42 | TABLE 114.3 SECTION 115 CONSTRUCTION DOCUMENTS EXAMINATION AND INSPECTION FEES |
43 | TABLE 115.2 TABLE 115.3 SECTION 116 BOARD COMMITTEES |
45 | CHAPTER 2: DEFINITIONS SECTION 201 GENERAL SECTION 202 GENERAL DEFINITIONS |
53 | CHAPTER 3: GENERAL REGULATIONS SECTION 301 GENERAL SECTION 302 EXCLUSION OF MATERIALS DETRIMENTAL TO THE SEWER SYSTEM SECTION 303 MATERIALS |
54 | TABLE 303.4 PRODUCTS AND MATERIALS REQUIRING THIRD-PARTY TESTING AND THIRD-PARTY CERTIFICATION SECTION 304 RODENTPROOFING SECTION 305 PROTECTION OF PIPES AND PLUMBING SYSTEM COMPONENTS |
55 | SECTION 306 TRENCHING, EXCAVATION AND BACKFILL SECTION 307 STRUCTURAL SAFETY SECTION 308 PIPING SUPPORT |
56 | TABLE 308.5 HANGER SPACING SECTION 309 FLOOD HAZARD RESISTANCE SECTION 310 WASHROOM AND TOILET ROOM REQUIREMENTS |
57 | SECTION 311 TOILET FACILITIES FOR WORKERS SECTION 312 TESTS AND INSPECTIONS |
58 | SECTION 313 EQUIPMENT EFFICIENCIES SECTION 314 CONDENSATE DISPOSAL TABLE [M] 314.2.2 CONDENSATE DRAIN SIZING |
59 | SECTION 315 WELDING AND BRAZING |
61 | CHAPTER 4: FIXTURES, FAUCETS AND FIXTURE FITTINGS SECTION 401 GENERAL SECTION 402 FIXTURE MATERIALS SECTION 403 MINIMUM PLUMBING FACILITIES TABLE 403.1 MINIMUM NUMBER OF REQUIRED PLUMBING FIXTURES |
62 | TABLE 403.1—continued MINIMUM NUMBER OF REQUIRED PLUMBING FIXTURES |
63 | TABLE 403.1—continued MINIMUM NUMBER OF REQUIRED PLUMBING FIXTURES |
64 | SECTION 404 ACCESSIBLE PLUMBING FACILITIES |
65 | SECTION 405 INSTALLATION OF FIXTURES FIGURE 405.3.1 FIXTURE CLEARANCE SECTION 406 AUTOMATIC CLOTHES WASHERS |
66 | SECTION 407 BATHTUBS SECTION 408 BIDETS SECTION 409 DISHWASHING MACHINES SECTION 410 DRINKING FOUNTAINS SECTION 411 EMERGENCY SHOWERS AND EYEWASH STATIONS SECTION 412 FLOOR AND TRENCH DRAINS SECTION 413 FOOD WASTE GRINDER UNITS |
67 | SECTION 414 GARBAGE CAN WASHERS SECTION 415 LAUNDRY TRAYS SECTION 416 LAVATORIES SECTION 417 SHOWERS |
68 | SECTION 418 SINKS SECTION 419 URINALS SECTION 420 WATER CLOSETS |
69 | SECTION 421 WHIRLPOOL BATHTUBS SECTION 422 HEALTH CARE FIXTURES AND EQUIPMENT |
70 | SECTION 423 SPECIALTY PLUMBING FIXTURES SECTION 424 FAUCETS AND OTHER FIXTURE FITTINGS SECTION 425 FLUSHING DEVICES FOR WATER CLOSETS AND URINALS |
71 | SECTION 426 MANUAL FOOD AND BEVERAGE DISPENSING EQUIPMENT SECTION 427 FLOOR SINKS |
73 | CHAPTER 5: WATER HEATERS SECTION 501 GENERAL SECTION 502 INSTALLATION SECTION 503 CONNECTIONS |
74 | SECTION 504 SAFETY DEVICES SECTION 505 INSULATION |
75 | CHAPTER 6: WATER SUPPLY AND DISTRIBUTION SECTION 601 GENERAL SECTION 602 WATER REQUIRED SECTION 603 WATER SERVICE SECTION 604 DESIGN OF BUILDING WATER DISTRIBUTION SYSTEM |
76 | TABLE 604.3 WATER DISTRIBUTION SYSTEM DESIGN CRITERIA REQUIRED CAPACITY AT FIXTURE SUPPLY PIPE OUTLETS TABLE 604.4 MAXIMUM FLOW RATES AND CONSUMPTION FOR PLUMBING FIXTURES AND FIXTURE FITTINGS TABLE 604.5 MINIMUM SIZES OF FIXTURE WATER SUPPLY PIPES |
77 | TABLE 604.10.1 MANIFOLD SIZING SECTION 605 MATERIALS, JOINTS AND CONNECTIONS |
78 | TABLE 605.3 WATER SERVICE PIPE TABLE 605.8 MANUFACTURED PIPE NIPPLES |
79 | TABLE 605.4 WATER DISTRIBUTION PIPE TABLE 605.5 PIPE FITTINGS |
82 | SECTION 606 INSTALLATION OF THE BUILDING WATER DISTRIBUTION SYSTEM TABLE 606.5.4 SIZES FOR OVERFLOW PIPES FOR WATER SUPPLY TANKS |
83 | TABLE 606.5.7 SIZE OF DRAIN PIPES FOR WATER TANKS SECTION 607 HOT WATER SUPPLY SYSTEM SECTION 608 PROTECTION OF POTABLE WATER SUPPLY |
84 | TABLE 608.8.3 SIZE OF PIPE IDENTIFICATION |
85 | TABLE 608.1 APPLICATION OF BACKFLOW PREVENTERS |
87 | TABLE 608.15.1 MINIMUM REQUIRED AIR GAPS |
88 | SECTION 609 HEALTH CARE PLUMBING SECTION 610 DISINFECTION OF POTABLE WATER SYSTEM |
89 | SECTION 611 DRINKING WATER TREATMENT UNITS SECTION 612 SOLAR SYSTEMS SECTION 613 TEMPERATURE CONTROL DEVICES AND VALVES |
91 | CHAPTER 7: SANITARY DRAINAGE SECTION 701 GENERAL SECTION 702 MATERIALS TABLE 702.1 ABOVE-GROUND DRAINAGE AND VENT PIPE |
92 | TABLE 702.2 UNDERGROUND BUILDING DRAINAGE AND VENT PIPE TABLE 702.4 PIPE FITTINGS SECTION 703 BUILDING SEWER |
93 | SECTION 704 DRAINAGE PIPING INSTALLATION TABLE 704.1 SLOPE OF HORIZONTAL DRAINAGE PIPE SECTION 705 JOINTS |
95 | TABLE 705.21 CAULKING FERRULE SPECIFICATIONS |
96 | TABLE 705.22 SOLDERING BUSHING SPECIFICATIONS SECTION 706 CONNECTIONS BETWEEN DRAINAGE PIPING AND FITTINGS TABLE 706.3 FITTINGS FOR CHANGE IN DIRECTION SECTION 707 PROHIBITED JOINTS AND CONNECTIONS SECTION 708 CLEANOUTS |
97 | SECTION 709 FIXTURE UNITS TABLE 709.2 DRAINAGE FIXTURE UNITS FOR FIXTURE DRAINS OR TRAPS |
98 | TABLE 709.1 DRAINAGE FIXTURE UNITS FOR FIXTURES AND GROUPS |
99 | SECTION 710 DRAINAGE SYSTEM SIZING SECTION 711 OFFSETS IN DRAINAGE PIPING IN BUILDINGS OF FIVE STORIES OR MORE SECTION 712 SUMPS AND EJECTORS |
100 | TABLE 710.1(1) BUILDING DRAINS AND SEWERS TABLE 710.1(2) HORIZONTAL FIXTURE BRANCHES AND STACKS |
101 | TABLE 712.4.2 MINIMUM CAPACITY OF SEWAGE PUMP OR SEWAGE EJECTOR SECTION 713 HEALTH CARE PLUMBING |
102 | TABLE 713.11.1 STACK SIZES FOR BEDPAN STEAMERS AND BOILING-TYPE STERILIZERS TABLE 713.11.3 STACK SIZES FOR PRESSURE STERILIZERS SECTION 714 COMPUTERIZED DRAINAGE DESIGN |
103 | SECTION 715 BACKWATER VALVES |
105 | CHAPTER 8: INDIRECT/SPECIAL WASTE SECTION 801 GENERAL SECTION 802 INDIRECT WASTES |
106 | SECTION 803 SPECIAL WASTES SECTION 804 MATERIALS, JOINTS AND CONNECTIONS |
107 | CHAPTER 9: VENTS SECTION 901 GENERAL SECTION 902 MATERIALS SECTION 903 OUTDOOR VENT EXTENSION SECTION 904 VENT TERMINALS |
108 | SECTION 905 VENT CONNECTIONS AND GRADES SECTION 906 FIXTURE VENTS TABLE 906.1 MAXIMUM DISTANCE OF FIXTURE TRAP FROM VENT SECTION 907 INDIVIDUAL VENT SECTION 908 COMMON VENT |
109 | TABLE 908.3 COMMON VENT SIZES SECTION 909 WET VENTING TABLE 909.3 WET VENT SIZE SECTION 910 WASTE STACK VENT TABLE 910.4 WASTE STACK VENT SIZE |
110 | SECTION 911 CIRCUIT VENTING SECTION 912 COMBINATION DRAIN AND VENT SYSTEM TABLE 912.3 SIZE OF COMBINATION DRAIN AND VENT PIPE SECTION 913 ISLAND FIXTURE VENTING |
111 | SECTION 914 RELIEF VENTS—STACKS OF MORE THAN 10 BRANCH INTERVALS SECTION 915 VENTS FOR STACK OFFSETS SECTION 916 VENT PIPE SIZING SECTION 917 AIR ADMITTANCE VALVES |
112 | TABLE 916.1 SIZE AND DEVELOPED LENGTH OF STACK VENTS AND VENT STACKS |
113 | TABLE 916.5.1 SIZE AND LENGTH OF SUMP VENTS |
114 | SECTION 918 ENGINEERED VENT SYSTEMS EQUATION 9-1 TABLE 918.2 MINIMUM DIAMETER AND MAXIMUM LENGTH OF INDIVIDUAL BRANCH FIXTURE VENTS ANDINDIVIDUAL FIXTURE HEADER VENTS FOR SMOOTH PIPES SECTION 919 COMPUTERIZED VENT DESIGN |
115 | CHAPTER 10: TRAPS, INTERCEPTORS AND SEPARATORS SECTION 1001 GENERAL SECTION 1002 TRAP REQUIREMENTS |
116 | SECTION 1003 INTERCEPTORS AND SEPARATORS TABLE 1003.3.4.1 CAPACITY OF GREASE INTERCEPTORSa |
117 | SECTION 1004 MATERIALS, JOINTS AND CONNECTIONS |
119 | CHAPTER 11: STORM DRAINAGE SECTION 1101 GENERAL SECTION 1102 MATERIALS TABLE 1102.4 BUILDING STORM SEWER PIPE TABLE 1102.5 SUBSOIL DRAIN PIPE |
120 | TABLE 1102.7 PIPE FITTINGS SECTION 1103 TRAPS SECTION 1104 CONDUCTORS AND CONNECTIONS SECTION 1105 ROOF DRAINS SECTION 1106 SIZE OF CONDUCTORS, LEADERS AND STORM DRAINS |
121 | FIGURE 1106.1100-YEAR, 1-HOUR RAINFALL (INCHES) EASTERN UNITED STATES |
122 | SECTION 1107 SECONDARY (EMERGENCY) ROOF DRAINS SECTION 1108 COMBINED SANITARY AND STORM SYSTEM SECTION 1109 VALUES FOR CONTINUOUS FLOW SECTION 1110 CONTROLLED FLOW ROOF DRAIN SYSTEMS SECTION 1111 SUBSOIL DRAINS SECTION 1112 BUILDING SUBDRAINS SECTION 1113 SUMPS AND PUMPING SYSTEMS |
123 | TABLE 1106.2(1) SIZE OF CIRCULAR VERTICAL CONDUCTORS AND LEADERS |
124 | TABLE 1106.2(2) SIZE OF RECTANGULAR VERTICAL CONDUCTORS AND LEADERS |
125 | TABLE 1106.3 SIZE OF HORIZONTAL STORM DRAINAGE PIPING |
126 | TABLE 1106.6 SIZE OF SEMICIRCULAR ROOF GUTTERS |
127 | CHAPTER 12: SPECIAL PIPING AND STORAGE SYSTEMS SECTION 1201 GENERAL SECTION 1202 MEDICAL GASES SECTION 1203 OXYGEN SYSTEMS |
129 | CHAPTER 13: REFERENCED STANDARDS ANSI AHRI ASME |
130 | ASSE |
131 | ASTM |
133 | AWS |
134 | AWWA CISPI CSA |
135 | ICC ISEA NFPA NSF |
136 | PDI UL |
137 | INDEX |
145 | VALUABLE GUIDES TO THE 2009 I-CODES® |
146 | LEARN AND APPLY PLUMBING, MECHANICAL, AND FUEL GAS CODES |
147 | TRAINING RESOURCES |
148 | MEMBERSHIP BENEFITS |