Shopping Cart

No products in the cart.

OR StructuralSpecialtyCode 2022 1stptg

$73.75

Oregon Structural Specialty Code, Based on the 2021 International Building Code

Published By Publication Date Number of Pages
OR 2022
Guaranteed Safe Checkout
Category:

If you have any questions, feel free to reach out to our online customer service team by clicking on the bottom right corner. We’re here to assist you 24/7.
Email:[email protected]

This is a fully integrated custom code based on the 2021 International Building Code®. Effective date: October 1, 2022.

PDF Catalog

PDF Pages PDF Title
1 2022 OREGON STRUCTUAL SPECIALTY CODE
3 COPYRIGHT
4 PREFACE
6 EFFECTIVE USE OF THE OREGON STRUCTURAL SPECIALTY CODE (OSSC)
16 TABLE OF CONTENTS
24 CHAPTER 1 SCOPE AND ADMINISTRATION
PART 1—SCOPE AND APPLICATION
SECTION 101 SCOPE AND GENERAL REQUIREMENTS
26 SECTION 102 APPLICABILITY
27 PART 2—ADMINISTRATION AND ENFORCEMENT
SECTION 103 CODE COMPLIANCE AGENCY
SECTION 104 DUTIES AND POWERS OF BUILDING OFFICIAL
29 SECTION 105 PERMITS
30 SECTION 106 FLOOR AND ROOF DESIGN LOADS
SECTION 107 CONSTRUCTION DOCUMENTS
33 SECTION 108 TEMPORARY STRUCTURES AND USES
SECTION 109 FEES
35 SECTION 110 INSPECTIONS
36 SECTION 111 CERTIFICATE OF OCCUPANCY
37 SECTION 112 SERVICE UTILITIES
SECTION 113 MEANS OF APPEALS
SECTION 114 VIOLATIONS
38 SECTION 115 STOP WORK ORDER
SECTION 116 UNSAFE STRUCTURES AND EQUIPMENT
40 CHAPTER 2 DEFINITIONS
SECTION 201 GENERAL
SECTION 202 DEFINITIONS
82 CHAPTER 3 OCCUPANCY CLASSIFICATION AND USE
SECTION 301 SCOPE
SECTION 302 OCCUPANCY CLASSIFICATIONAND USE DESIGNATION
SECTION 303 ASSEMBLY GROUP A
83 SECTION 304 BUSINESS GROUP B
84 SECTION 305 EDUCATIONAL GROUP E
SECTION 306 FACTORY GROUP F
85 SECTION 307 HIGH-HAZARD GROUP H
86 TABLE 307.1(1) MAXIMUM ALLOWABLE QUANTITY PER CONTROL AREA OF HAZARDOUS MATERIALS POSING A PHYSICAL HAZARD
87 TABLE 307.1(1)—continued MAXIMUM ALLOWABLE QUANTITY PER CONTROL AREA OF HAZARDOUS MATERIALS POSING A PHYSICAL HAZARD
88 TABLE 307.1(2) MAXIMUM ALLOWABLE QUANTITY PER CONTROL AREA OF HAZARDOUS MATERIALS POSING A HEALTH HAZARD
89 SECTION 308 INSTITUTIONAL GROUP I
91 SECTION 309 MERCANTILE GROUP M
SECTION 310 RESIDENTIAL GROUP R
92 SECTION 311 STORAGE GROUP S
93 SECTION 312 UTILITY AND MISCELLANEOUS GROUP U
94 CHAPTER 4 SPECIAL DETAILED REQUIREMENTS BASED ON OCCUPANCY AND USE
SECTION 401 SCOPE
SECTION 402 COVERED MALL AND OPEN MALL BUILDINGS
98 SECTION 403 HIGH-RISE BUILDINGS
99 TABLE 403.2.3 MINIMUM BOND STRENGTH
101 SECTION 404 ATRIUMS
102 SECTION 405 UNDERGROUND BUILDINGS
103 SECTION 406 MOTOR-VEHICLE-RELATED OCCUPANCIES
105 TABLE 406.5.4 OPEN PARKING GARAGES AREA AND HEIGHT
110 SECTION 407 GROUP I-2
114 SECTION 408 GROUP I-3
116 SECTION 409 MOTION PICTURE PROJECTION ROOMS
117 SECTION 410 STAGES, PLATFORMS AND TECHNICAL PRODUCTION AREAS
119 SECTION 411 SPECIAL AMUSEMENT AREAS
120 SECTION 412 AIRCRAFT-RELATED OCCUPANCIES
TABLE 412.2.1.1 HEIGHT LIMITATIONS FOR AIRPORT TRAFFIC CONTROL TOWERS
122 TABLE 412.3.6 HANGAR FIRE SUPPRESSION REQUIREMENTS
123 TABLE 412.6 AIRCRAFT MANUFACTURING EXIT ACCESS TRAVEL DISTANCE
124 SECTION 413 COMBUSTIBLE STORAGE
SECTION 414 HAZARDOUS MATERIALS
126 TABLE 414.2.2 DESIGN AND NUMBER OF CONTROL AREAS
128 TABLE 414.2.5(1) MAXIMUM ALLOWABLE QUANTITY PER INDOOR CONTROL AREA INGROUP M AND S OCCUPANCIES OF NONFLAMMABLE SOLIDS AND NONFLAMMABLE AND NONCOMBUSTIBLE LIQUIDS
TABLE 414.2.5(2) MAXIMUM ALLOWABLE QUANTITY OF FLAMMABLE AND COMBUSTIBLE LIQUIDS IN WHOLESALE AND RETAIL SALES OCCUPANCIES PER CONTROL AREA
129 TABLE 414.5.1 EXPLOSION CONTROL REQUIREMENTS
132 SECTION 415 GROUPS H-1, H-2, H-3, H-4 AND H-5
134 TABLE 415.6.5 DETACHED BUILDING REQUIRED
136 TABLE 415.11.1.1.1 QUANTITY LIMITS FOR HAZARDOUS MATERIALS IN A SINGLE FABRICATION AREA IN GROUP H-5
141 TABLE 415.11.7.2 MAXIMUM QUANTITIES OF HPM AT A WORKSTATION
144 TABLE 415.12.2 REQUIRED SECONDARY CONTAINMENT HAZARDOUS MATERIAL SOLIDS AND LIQUIDS STORAGE
147 TABLE 415.13.12.1.4 REQUIRED SECONDARY CONTAINMENT—HAZARDOUS MATERIAL LIQUIDS USE
SECTION 416 APPLICATION OF FLAMMABLE FINISHES
153 SECTION 417 DRYING ROOMS
154 SECTION 418 ORGANIC COATINGS
155 SECTION 419 RESERVED
SECTION 420 GROUPS I-1, R-1, R-2, R-3 AND R-4
157 SECTION 421 HYDROGEN FUEL GAS ROOMS
SECTION 422 AMBULATORY CARE FACILITIES
158 SECTION 423 STORM SHELTERS
SECTION 424 PLAY STRUCTURES
159 SECTION 425 HYPERBARIC FACILITIES
SECTION 426 COMBUSTIBLE DUSTS,GRAIN PROCESSING AND STORAGE
TABLE 426.1 EXPLOSION PROTECTION STANDARDS
160 TABLE 426.1.10.1.2 MINIMUM CONVEYING VELOCITIES
161 SECTION 427 MEDICAL GAS SYSTEMS
TABLE 427.2 PERMITTED AMOUNTS FOR COMPRESSED GASES
162 SECTION 428 HIGHER EDUCATION LABORATORIES
SECTION 429 STATIONARY FUEL CELL POWER SYSTEMS
163 SECTION 430 ELECTRICAL ENERGY STORAGE SYSTEMS (ESS)
164 TABLE 430.2 ENERGY STORAGE SYSTEM (ESS) THRESHOLD QUANTITIES
166 TABLE 430.7 MAXIMUM ALLOWABLE BATTERY QUANTITIES
167 TABLE 430.8 ELECTROCHEMICAL ESS TECHNOLOGY-SPECIFIC REQUIREMENTS
169 TABLE 430.9 INDOOR ESS INSTALLATIONS
TABLE 430.10 SPECIAL ESS INSTALLATIONS
171 FIGURE 430.11.6.2 ESS VEHICLE IMPACT PROTECTION
172 SECTION 431 DRY CLEANING SOLVENTS AND SYSTEMS
173 SECTION 432 FRUIT AND CROP RIPENING
SECTION 433 LUMBER YARDS AND WOODWORKING FACILITIES
174 SECTION 434 INDUSTRIAL OVENS
SECTION 435 HIGH-PILED COMBUSTIBLE STORAGE
176 (EQUATION 4-2)
(EQUATION 4-3)
(EQUATION 4-4)
177 TABLE 435.3.7 EXAMPLES OF COMMODITY CLASSIFICATION
178 TABLE 435.3.7—CONTINUED EXAMPLES OF COMMODITY CLASSIFICATION
179 TABLE 435.3.7—CONTINUED EXAMPLES OF COMMODITY CLASSIFICATION
180 TABLE 435.3.7—CONTINUED EXAMPLES OF COMMODITY CLASSIFICATION
181 TABLE 435.3.7—CONTINUED EXAMPLES OF COMMODITY CLASSIFICATION
182 TABLE 435.3.7—CONTINUED EXAMPLES OF COMMODITY CLASSIFICATION
183 TABLE 435.3.7—CONTINUED EXAMPLES OF COMMODITY CLASSIFICATION
184 FIGURE 435.3.8(1) EVALUATION OF CARTONED COMMODITIES CONTAINING GROUP A PLASTICS
185 FIGURE 435.3.8(2) EVALUATION OF EXPOSED COMMODITIES CONTAINING GROUP A PLASTICS
186 TABLE 435.5.1 GENERAL FIRE PROTECTION AND LIFE SAFETY REQUIREMENTS
189 TABLE 435.13.2 REQUIRED FLUE SPACES FOR RACK STORAGE
190 SECTION 436 TIRE REBUILDING
SECTION 437 COMBUSTIBLE FIBERS
191 SECTION 438 PROCESSING AND EXTRACTION FACILITIES
SECTION 439 AEROSOLS
TABLE 439.3 CLASSIFICATION OF AEROSOL PRODUCTS
192 TABLE 439.6.1 NONSEGREGATED STORAGE OF LEVEL 2 AND 3 AEROSOL PRODUCTS AND PLASTIC AEROSOL 3 PRODUCTS IN GENERAL PURPOSE WAREHOUSES
193 TABLE 439.6.2 SEGREGATED STORAGE OF LEVEL 2 AND 3 AEROSOL PRODUCTS AND PLASTIC AEROSOL 3 PRODUCTS IN GENERAL PURPOSE WAREHOUSES
TABLE 439.6.2.2 SEGREGATED STORAGE AISLE WIDTHS AND DISTANCE TO AISLES IN GENERAL PURPOSE WAREHOUSES
194 TABLE 439.10 MAXIMUM QUANTITIES OF LEVEL 2 AND 3 AEROSOL PRODUCTS AND AEROSOL COOKING SPRAY PRODUCTS AND PLASTIC AEROSOL 3 PRODUCTS IN RETAIL STORAGE AREAS
TABLE 439.12.1.1 MAXIMUM QUANTITIES OF LEVEL 2 AND 3 AEROSOL PRODUCTS, AEROSOL COOKING SPRAY PRODUCTS AND PLASTIC AEROSOL 3 PRODUCTS IN RETAIL DISPLAY AREAS
196 TABLE 439.12.3 MAXIMUM STORAGE QUANTITIES FOR STORAGE AREAS ADJACENT TO RETAIL DISPLAY OF LEVEL 2 AND 3 AEROSOL PRODUCTS
SECTION 440 COMPRESSED GASES
201 SECTION 441 CORROSIVE MATERIALS
SECTION 442 CRYOGENIC FLUIDS
203 SECTION 443 EXPLOSIVES AND FIREWORKS
204 TABLE 443.2.1(1) MINIMUM INTRALINE (INTRAPLANT) SEPARATION DISTANCES (ILD OR IPD) BETWEEN BARRICADED OPERATING BUILDINGS CONTAINING EXPLOSIVES—DIVISION 1.1, 1.2 OR 1.5 MASS-EXPLOSION HAZARD
205 TABLE 443.2.1(2) AMERICAN TABLE OF DISTANCES FOR STORAGE OF EXPLOSIVES AS APPROVED BY THE INSTITUTE OF MAKERS OF EXPLOSIVES AND REVISED JUNE 1991
206 TABLE 443.2.1(2)—CONTINUED AMERICAN TABLE OF DISTANCES FOR STORAGE OF EXPLOSIVES AS APPROVED BY THE INSTITUTE OF MAKERS OF EXPLOSIVES AND REVISED JUNE 1991
207 TABLE 443.2.1(3) TABLE OF DISTANCES (Q-D) FOR BUILDINGS AND MAGAZINES CONTAINING EXPLOSIVES—DIVISION 1.3 MASS-FIRE HAZARD
TABLE 443.2.1(4) TABLE OF DISTANCES (Q-D) FOR BUILDINGS AND MAGAZINES CONTAINING EXPLOSIVES—DIVISION 1.4
209 SECTION 444 FLAMMABLE AND COMBUSTIBLE LIQUIDS
210 TABLE 444.2.1 CLASS I ELECTRICAL EQUIPMENT LOCATIONS
211 TABLE 444.2.1—CONTINUED CLASS I ELECTRICAL EQUIPMENT LOCATIONS
219 TABLE 444.4.6.3(1) MAXIMUM STORAGE HEIGHT IN CONTROL AREA
220 TABLE 444.4.6.3(2) STORAGE ARRANGEMENTS FOR PALLETIZED OR SOLID-PILE STORAGE IN LIQUID STORAGE ROOMS AND WAREHOUSES
TABLE 444.4.6.3(3) STORAGE ARRANGEMENTS FOR RACK STORAGE IN LIQUID STORAGE ROOMS AND WAREHOUSES
221 TABLE 444.4.6.3(4) AUTOMATIC SPRINKLER PROTECTION FOR SOLID-PILE AND PALLETIZED STORAGE OF LIQUIDS IN METAL CONTAINERS AND PORTABLE TANKS
222 TABLE 444.4.6.3(5) AUTOMATIC SPRINKLER PROTECTION REQUIREMENTS FOR RACK STORAGE OF LIQUIDS INMETAL CONTAINERS OF 5-GALLON CAPACITY OR LESS WITH OR WITHOUT CARTONS ON CONVENTIONAL WOOD PALLETS
223 TABLE 444.4.6.3(6) AUTOMATIC SPRINKLER PROTECTION REQUIREMENTS FOR RACK STORAGE OF LIQUIDS IN METAL CONTAINERS GREATER THAN 5-GALLON CAPACITY
TABLE 444.4.6.3(7) AUTOMATIC AFFF WATER PROTECTION REQUIREMENTS FOR RACK STORAGE OF LIQUIDS IN METAL CONTAINERS GREATER THAN 5-GALLON CAPACITY
224 TABLE 444.4.6.3(8) AUTOMATIC SPRINKLER PROTECTION REQUIREMENTS FOR CLASS I LIQUID STORAGE IN METAL CONTAINERS OF 1-GALLON CAPACITY OR LESS WITH UNCARTONED OR CASE-CUT SHELF DISPLAY UP TO 6.5 FEET, AND PALLETIZED STORAGE ABOVE IN A DOUBLE-ROW RACK ARRAY
225 TABLE 444.4.7.5.1 AUTOMATIC AFFF-WATER PROTECTION REQUIREMENTS FOR SOLID-PILE AND PALLETIZED STORAGE OF LIQUIDS IN METAL CONTAINERS OF 5-GALLON CAPACITY OR LESS
230 SECTION 445 FLAMMABLE GASES AND FLAMMABLE CRYOGENIC FLUIDS
231 SECTION 446 FLAMMABLE SOLIDS
232 SECTION 447 HIGHLY TOXIC AND TOXIC MATERIALS
237 SECTION 448 LIQUEFIED PETROLEUM GASES
SECTION 449 ORGANIC PEROXIDES
238 TABLE 449.4.2 ORGANIC PEROXIDES—DISTANCE TO EXPOSURES FROM DETACHED STORAGE BUILDINGS OR OUTDOOR STORAGE AREAS
239 TABLE 449.4.7 STORAGE OF ORGANIC PEROXIDES
SECTION 450 OXIDIZERS, OXIDIZING GASES AND OXIDIZING CRYOGENIC FLUIDS
240 TABLE 450.2.2 STORAGE OF CLASS 1 OXIDIZER LIQUIDS AND SOLIDS
TABLE 450.3.5(1) STORAGE OF CLASS 2 OXIDIZER LIQUIDS AND SOLIDS
241 TABLE 450.3.5(2) STORAGE OF CLASS 3 OXIDIZER LIQUIDS AND SOLIDS
TABLE 450.3.5(3) STORAGE OF CLASS 4 OXIDIZER LIQUIDS AND SOLIDS
SECTION 451 PYROPHORIC MATERIALS
242 SECTION 452 PYROXYLIN (CELLULOSE NITRATE) PLASTICS
SECTION 453 UNSTABLE (REACTIVE) MATERIALS
243 SECTION 454 WATER-REACTIVE SOLIDS AND LIQUIDS
244 SECTION 455 ADDITIVE MANUFACTURING (3D PRINTING)
SECTION 456 STORAGE OF DISTILLED SPIRITS AND WINES
245 SECTION 457 PIERS AND WHARVES
SECTION 458MAUSOLEUMS AND COLUMBARIUMS
248 CHAPTER 5 GENERAL BUILDING HEIGHTS AND AREAS
SECTION 501 GENERAL
SECTION 502 BUILDING ADDRESS
SECTION 503 GENERAL BUILDING HEIGHT AND AREA LIMITATIONS
SECTION 504 BUILDING HEIGHT AND NUMBER OF STORIES
249 SECTION 505 MEZZANINES AND EQUIPMENT PLATFORMS
250 TABLE 504.3 ALLOWABLE BUILDING HEIGHT IN FEET ABOVE GRADE PLANE
251 TABLE 504.4 ALLOWABLE NUMBER OF STORIES ABOVE GRADE PLANE
252 TABLE 504.4—CONTINUED ALLOWABLE NUMBER OF STORIES ABOVE GRADE PLANE
SECTION 506 BUILDING AREA
(Equation 5-1)
253 (Equation 5-2)
(Equation 5-3)
SECTION 507 UNLIMITED AREA BUILDINGS
254 TABLE 506.2 ALLOWABLE AREA FACTOR (At = NS, S1, S13R, S13D or SM, AS APPLICABLE) IN SQUARE FEET
255 TABLE 506.2—CONTINUED ALLOWABLE AREA FACTOR (At = NS, S1, S13R, S13D or SM, AS APPLICABLE) IN SQUARE FEET
256 TABLE 506.2—CONTINUED ALLOWABLE AREA FACTOR (At = NS, S1, S13R, S13D or SM, AS APPLICABLE) IN SQUARE FEET
257 TABLE 506.3.3 FRONTAGE INCREASE FACTOR
TABLE 506.3.3.1 SECTION 507 BUILDINGS
258 SECTION 508 MIXED USE AND OCCUPANCY
260 TABLE 508.4 REQUIRED SEPARATION OF OCCUPANCIES (HOURS)
261 SECTION 509 INCIDENTAL USES
TABLE 509.1 INCIDENTAL USES
262 SECTION 510 SPECIAL PROVISIONS
266 CHAPTER 6 TYPES OF CONSTRUCTION
SECTION 601 GENERAL
TABLE 601 FIRE-RESISTANCE RATING REQUIREMENTS FOR BUILDING ELEMENTS (HOURS)
SECTION 602 CONSTRUCTION CLASSIFICATION
269 SECTION 603 COMBUSTIBLE MATERIAL IN TYPES I AND II CONSTRUCTION
272 CHAPTER 7 FIRE AND SMOKE PROTECTION FEATURES
SECTION 701 GENERAL
SECTION 702 MULTIPLE-USE FIRE ASSEMBLIES
SECTION 703 FIRE-RESISTANCE RATINGS AND FIRE TESTS
273 SECTION 704 FIRE-RESISTANCE RATING OF STRUCTURAL MEMBERS
275 SECTION 705 EXTERIOR WALLS
TABLE 705.2 MINIMUM DISTANCE OF PROJECTION
276 (EQUATION 7-1)
277 (EQUATION 7-2)
TABLE 705.5 FIRE-RESISTANCE RATING REQUIREMENTS FOR EXTERIOR WALLS BASED ON FIRE SEPARATION DISTANCE
278 FIGURE 705.7 EQUIVALENT OPENING FACTOR
279 TABLE 705.8 MAXIMUM AREA OF EXTERIOR WALL OPENINGS BASED ONFIRE SEPARATION DISTANCE AND DEGREE OF OPENING PROTECTION
280 SECTION 706 FIRE WALLS
281 TABLE 706.4 FIRE WALL FIRE-RESISTANCE RATINGS
283 SECTION 707 FIRE BARRIERS
TABLE 707.3.10 FIRE-RESISTANCE-RATING REQUIREMENTS FOR FIRE BARRIERS, FIRE WALLS OR HORIZONTAL ASSEMBLIES BETWEEN FIRE AREAS
284 SECTION 708 FIRE PARTITIONS
286 SECTION 709 SMOKE BARRIERS
SECTION 710 SMOKE PARTITIONS
287 SECTION 711 FLOOR AND ROOF ASSEMBLIES
288 SECTION 712 VERTICAL OPENINGS
289 SECTION 713 SHAFT ENCLOSURES
291 SECTION 714 PENETRATIONS
294 SECTION 715 JOINTS AND VOIDS
295 SECTION 716 OPENING PROTECTIVES
296 TABLE 716.1(1) MARKING FIRE-RATED GLAZING ASSEMBLIES
TABLE 716.1(2) OPENING FIRE PROTECTION ASSEMBLIES, RATINGS AND MARKINGS
297 TABLE 716.1(2)—CONTINUED OPENING FIRE PROTECTION ASSEMBLIES, RATINGS AND MARKINGS
298 TABLE 716.1(2)—CONTINUED OPENING FIRE PROTECTION ASSEMBLIES, RATINGS AND MARKINGS
TABLE 716.1(3) FIRE WINDOW ASSEMBLY FIRE PROTECTION RATINGS
302 SECTION 717 DUCTS AND AIR TRANSFER OPENINGS
303 TABLE 717.3.2.1 FIRE DAMPER RATING
307 SECTION 718 CONCEALED SPACES
309 SECTION 719 FIRE-RESISTANCE REQUIREMENTS FOR PLASTER
SECTION 720 THERMAL- AND SOUND-INSULATING MATERIALS
310 SECTION 721 PRESCRIPTIVE FIRE RESISTANCE
311 SECTION 722 CALCULATED FIRE RESISTANCE
TABLE 722.2.1.1 MINIMUM EQUIVALENT THICKNESS OFCAST-IN-PLACE OR PRECAST CONCRETE WALLS,LOAD-BEARING OR NONLOAD-BEARING
(EQUATION 7-3)
312 TABLE 721.1(1) MINIMUM PROTECTION OF STRUCTURAL PARTS BASED ONTIME PERIODS FOR VARIOUS NONCOMBUSTIBLE INSULATING MATERIALS
313 TABLE 721.1(1)—CONTINUED MINIMUM PROTECTION OF STRUCTURAL PARTS BASED ONTIME PERIODS FOR VARIOUS NONCOMBUSTIBLE INSULATING MATERIALS
314 TABLE 721.1(1)—CONTINUED MINIMUM PROTECTION OF STRUCTURAL PARTS BASED ONTIME PERIODS FOR VARIOUS NONCOMBUSTIBLE INSULATING MATERIALS
315 TABLE 721.1(1)—CONTINUED MINIMUM PROTECTION OF STRUCTURAL PARTS BASED ONTIME PERIODS FOR VARIOUS NONCOMBUSTIBLE INSULATING MATERIALS
316 TABLE 721.1(2) RATED FIRE-RESISTANCE PERIODS FOR VARIOUS WALLS AND PARTITIONS
317 TABLE 721.1(2)—CONTINUED RATED FIRE-RESISTANCE PERIODS FOR VARIOUS WALLS AND PARTITIONS
318 TABLE 721.1(2)—CONTINUED RATED FIRE-RESISTANCE PERIODS FOR VARIOUS WALLS AND PARTITIONS
319 TABLE 721.1(2)—CONTINUED RATED FIRE-RESISTANCE PERIODS FOR VARIOUS WALLS AND PARTITIONS
320 TABLE 721.1(2)—CONTINUED RATED FIRE-RESISTANCE PERIODS FOR VARIOUS WALLS AND PARTITIONS
321 TABLE 721.1(2)—CONTINUED RATED FIRE-RESISTANCE PERIODS FOR VARIOUS WALLS AND PARTITIONS
322 TABLE 721.1(2)—CONTINUED RATED FIRE-RESISTANCE PERIODS FOR VARIOUS WALLS AND PARTITIONS
323 TABLE 721.1(2)—CONTINUED RATED FIRE-RESISTANCE PERIODS FOR VARIOUS WALLS AND PARTITIONS
324 TABLE 721.1(2)—CONTINUED RATED FIRE-RESISTANCE PERIODS FOR VARIOUS WALLS AND PARTITIONS
TABLE 721.1(3) MINIMUM PROTECTION FOR FLOOR AND ROOF SYSTEMS
325 TABLE 721.1(3)—CONTINUED MINIMUM PROTECTION FOR FLOOR AND ROOF SYSTEMS
326 TABLE 721.1(3)—CONTINUED MINIMUM PROTECTION FOR FLOOR AND ROOF SYSTEMS
327 TABLE 721.1(3)—CONTINUED MINIMUM PROTECTION FOR FLOOR AND ROOF SYSTEMS
328 TABLE 721.1(3)—CONTINUED MINIMUM PROTECTION FOR FLOOR AND ROOF SYSTEMS
329 TABLE 721.1(3)—CONTINUED MINIMUM PROTECTION FOR FLOOR AND ROOF SYSTEMS
330 TABLE 721.1(3)—CONTINUED MINIMUM PROTECTION FOR FLOOR AND ROOF SYSTEMS
331 TABLE 721.1(3)—CONTINUED MINIMUM PROTECTION FOR FLOOR AND ROOF SYSTEMS
332 TABLE 721.1(3)—CONTINUED MINIMUM PROTECTION FOR FLOOR AND ROOF SYSTEMS
333 TABLE 721.1(3)—CONTINUED MINIMUM PROTECTION FOR FLOOR AND ROOF SYSTEMS
334 TABLE 721.1(3)—CONTINUED MINIMUM PROTECTION FOR FLOOR AND ROOF SYSTEMS
335 TABLE 721.1(3)—CONTINUED MINIMUM PROTECTION FOR FLOOR AND ROOF SYSTEMS
336 (Equation 7-4)
337 FIGURE 722.2.1.2 FIRE-RESISTANCE RATINGS OF TWO-WYTHE CONCRETE WALLS
TABLE 722.2.1.2(1) VALUES OF Rn0.59 FOR USE IN EQUATION 7-4
TABLE 722.2.1.2(2) FIRE-RESISTANCE RATINGS BASED ON R
338 FIGURE 722.2.1.3.1 CERAMIC FIBER JOINT PROTECTION
TABLE 722.2.1.4(1) MULTIPLYING FACTOR FOR FINISHES ON NONFIRE-EXPOSED SIDE OF WALL
TABLE 722.2.1.4(2) TIME ASSIGNED TO FINISH MATERIALSON FIRE-EXPOSED SIDE OF WALL
339 TABLE 722.2.2.1 MINIMUM SLAB THICKNESS (INCHES)
FIGURE 722.2.2.1.2 DETERMINATION OF SLAB THICKNESS FOR SLOPING SOFFITS
FIGURE 722.2.2.1.3 SLABS WITH RIBBED OR UNDULATING SOFFITS
(EQUATION 7-5)
340 FIGURE 722.2.2.2 FIRE-RESISTANCE RATINGS FORTWO-COURSE CONCRETE FLOORS
FIGURE 722.2.2.3(1) FIRE-RESISTANCE RATINGS FOR CONCRETE ROOF ASSEMBLIES
FIGURE 722.2.2.3(2)FIRE-RESISTANCE RATINGS FOR CONCRETE ROOF ASSEMBLIES
341 TABLE 722.2.3(1) COVER THICKNESS FOR REINFORCED CONCRETE FLOOR OR ROOF SLABS (INCHES)
TABLE 722.2.3(2) COVER THICKNESS FOR PRESTRESSED CONCRETE FLOOR OR ROOF SLABS (INCHES)
TABLE 722.2.3(3) MINIMUM COVER FOR MAIN REINFORCING BARS OF REINFORCED CONCRETE BEAMSc(APPLICABLE TO ALL TYPES OF STRUCTURAL CONCRETE)
342 TABLE 722.2.3(4) MINIMUM COVER FOR PRESTRESSED CONCRETE BEAMS 8 INCHES OR GREATER IN WIDTH
TABLE 722.2.3(5)MINIMUM COVER FOR PRESTRESSED CONCRETE BEAMS OF ALL WIDTHS
TABLE 722.2.4 MINIMUM DIMENSION OF CONCRETE COLUMNS (INCHES)
343 (EQUATION 7-6)
TABLE 722.3.2 MINIMUM EQUIVALENT THICKNESS (INCHES) OF BEARING OR NONBEARING CONCRETE MASONRY WALLS
344 (EQUATION 7-7)
TABLE 722.3.4 MINIMUM COVER OF LONGITUDINAL REINFORCEMENT IN FIRE-RESISTANCE-RATED REINFORCED CONCRETE MASONRY LINTELS (INCHES)
TABLE 722.3.5 MINIMUM DIMENSION OF CONCRETE MASONRY COLUMNS (INCHES)
345 TABLE 722.4.1(1) FIRE-RESISTANCE PERIODS OF CLAY MASONRY WALLS
TABLE 722.4.1(2) FIRE-RESISTANCE RATINGS FOR BEARING STEEL FRAME BRICK VENEER WALLS OR PARTITIONS
TABLE 722.4.1(3) VALUES OF R
TABLE 722.4.1(4) COEFFICIENTS FOR PLASTER, PL
TABLE 722.4.1(5) REINFORCED MASONRY LINTELS
TABLE 722.4.1(6) REINFORCED CLAY MASONRY COLUMNS
346 (EQUATION 7-8)
(EQUATION 7-9)
(EQUATION 7-10)
(EQUATION 7-11)
347 FIGURE 722.5.1(1) DETERMINATION OF THE HEATED PERIMETER OF STRUCTURAL STEEL COLUMNS
(EQUATION 7-12)
(EQUATION 7-13)
348 TABLE 722.5.1(1) W/D RATIOS FOR STEEL COLUMNS
TABLE 722.5.1(1)—CONTINUED W/D RATIOS FOR STEEL COLUMNS
349 TABLE 722.5.1(2) PROPERTIES OF CONCRETE
TABLE 722.5.1(3) THERMAL CONDUCTIVITY OF CONCRETE OR CLAY MASONRY UNITS
350 TABLE 722.5.1(4) WEIGHT-TO-HEATED-PERIMETER RATIOS (W/D) FOR TYPICAL WIDE FLANGE BEAM AND GIRDER SHAPES
TABLE 722.5.1(4)—CONTINUED WEIGHT-TO-HEATED-PERIMETER RATIOS (W/D) FOR TYPICAL WIDE FLANGE BEAM AND GIRDER SHAPES
351 TABLE 722.5.1(4)—CONTINUED WEIGHT-TO-HEATED-PERIMETER RATIOS (W/D) FOR TYPICAL WIDE FLANGE BEAM AND GIRDER SHAPES
TABLE 722.5.1(4)—CONTINUED WEIGHT-TO-HEATED-PERIMETER RATIOS (W/D) FOR TYPICAL WIDE FLANGE BEAM AND GIRDER SHAPES
352 TABLE 722.5.1(5) FIRE RESISTANCE OF CONCRETE MASONRY PROTECTED STEEL COLUMNS
TABLE 722.5.1(5)—CONTINUED FIRE RESISTANCE OF CONCRETE MASONRY PROTECTED STEEL COLUMNS
353 TABLE 722.5.1(5)—CONTINUED FIRE RESISTANCE OF CONCRETE MASONRY PROTECTED STEEL COLUMNS
TABLE 722.5.1(5)—CONTINUED FIRE RESISTANCE OF CONCRETE MASONRY PROTECTED STEEL COLUMNS
354 TABLE 722.5.1(6) FIRE RESISTANCE OF CLAY MASONRY PROTECTED STEEL COLUMNS
355 TABLE 722.5.1(7) MINIMUM COVER (inch) FOR STEEL COLUMNS ENCASED IN NORMAL-WEIGHT CONCRETE [FIGURE 722.5.1(6)(c)]
TABLE 722.5.1(8) MINIMUM COVER (inch) FOR STEEL COLUMNS ENCASED IN STRUCTURAL LIGHTWEIGHT CONCRETE[FIGURE 722.5.1(6)(c)]
356 TABLE 722.5.1(9) MINIMUM COVER (inch) FOR STEEL COLUMNS IN NORMAL-WEIGHT PRECAST COVERS [FIGURE 722.5.1 (6)(a)]
TABLE 722.5.1(10) MINIMUM COVER (inch) FOR STEEL COLUMNS IN STRUCTURAL LIGHTWEIGHT PRECAST COVERS [FIGURE 722.5.1 (6)(a)]
357 FIGURE 722.5.1(2) GYPSUM-PROTECTED STRUCTURAL STEEL COLUMNS WITH SHEET STEEL COLUMN COVERS
FIGURE 722.5.1(3) GYPSUM-PROTECTED STRUCTURAL STEEL COLUMNS WITH STEEL STUD/SCREW ATTACHMENT SYSTEM
358 FIGURE 722.5.1(4) FIRE RESISTANCE OF STRUCTURAL STEEL COLUMNS PROTECTED WITH VARIOUS THICKNESSES OF TYPE X GYPSUM WALLBOARD
FIGURE 722.5.1(5) WIDE FLANGE STRUCTURAL STEEL COLUMNS WITH SPRAYED FIRE-RESISTANT MATERIALS
FIGURE 722.5.1(6) CONCRETE PROTECTED STRUCTURAL STEEL COLUMNS
359 FIGURE 722.5.1(7)CONCRETE OR CLAY MASONRY PROTECTED STRUCTURAL STEEL COLUMNS
(EQUATION 7-14)
(EQUATION 7-15)
360 (EQUATION 7-16)
FIGURE 722.5.2 DETERMINATION OF THE HEATED PERIMETER OF STRUCTURAL STEEL BEAMS AND GIRDERS
(EQUATION 7-17)
361 TABLE 722.6.2(1) TIME ASSIGNED TO WALLBOARD MEMBRANES
362 TABLE 722.6.2(2) TIME ASSIGNED FOR CONTRIBUTION OF WOOD FRAME
TABLE 722.6.2(3) MEMBRANE ON EXTERIOR FACE OF WOOD STUD WALLS
TABLE 722.6.2(4) FLOORING OR ROOFING OVER WOOD FRAMING
TABLE 722.6.2(5) TIME ASSIGNED FOR ADDITIONAL PROTECTION
364 TABLE 722.7.1(1) PROTECTION REQUIRED FROM NONCOMBUSTIBLE COVERING MATERIAL
TABLE 722.7.1(2) PROTECTION PROVIDED BY NONCOMBUSTIBLE COVERING MATERIAL
366 CHAPTER 8 INTERIOR FINISHES
SECTION 801 SCOPE
SECTION 802 GENERAL
SECTION 803 WALL AND CEILING FINISHES
368 TABLE 803.13 INTERIOR WALL AND CEILING FINISH REQUIREMENTS BY OCCUPANCY
369 SECTION 804 INTERIOR FLOOR FINISH
SECTION 805 COMBUSTIBLE MATERIALS INTYPES I AND II CONSTRUCTION
370 SECTION 806 DECORATIVE MATERIALS AND TRIM
SECTION 807 INSULATION
SECTION 808 ACOUSTICAL CEILING SYSTEMS
372 CHAPTER 9 FIRE PROTECTION AND LIFE SAFETY SYSTEMS
SECTION 901 GENERAL
373 SECTION 902 FIRE PUMP AND RISER ROOM SIZE
SECTION 903 AUTOMATIC SPRINKLER SYSTEMS
375 [F] TABLE 903.2.5.2 GROUP H-5 SPRINKLER DESIGN CRITERIA
377 TABLE 903.2.11.6 ADDITIONAL REQUIRED PROTECTION SYSTEMS
380 SECTION 904 ALTERNATIVE AUTOMATIC FIRE-EXTINGUISHING SYSTEMS
382 SECTION 905 STANDPIPE SYSTEMS
384 SECTION 906 PORTABLE FIRE EXTINGUISHERS
SECTION 907 FIRE ALARM AND DETECTION SYSTEMS
394 [F] TABLE 907.5.2.3.2 VISIBLE ALARMS
395 SECTION 908 EMERGENCY ALARM SYSTEMS
SECTION 909 SMOKE CONTROL SYSTEMS
397 (EQUATION 9-1)
(EQUATION 9-2)
403 SECTION 910 SMOKE AND HEAT REMOVAL
404 SECTION 911 FIRE COMMAND CENTER
406 SECTION 912 FIRE DEPARTMENT CONNECTIONS
SECTION 913 FIRE PUMPS
407 SECTION 914 EMERGENCY RESPONDER SAFETY FEATURES
SECTION 915 CARBON MONOXIDE DETECTION
409 SECTION 916 GAS DETECTION SYSTEMS
SECTION 917 MASS NOTIFICATION SYSTEMS
SECTION 918 EMERGENCY RESPONDER COMMUNICATION COVERAGE
411 SECTION 919 EXPLOSION CONTROL
412 CHAPTER 10 MEANS OF EGRESS
SECTION 1001 ADMINISTRATION
SECTION 1002 ALTERATIONS
SECTION 1003 GENERAL MEANS OF EGRESS
413 SECTION 1004 OCCUPANT LOAD
414 TABLE 1004.5 MAXIMUM FLOOR AREA ALLOWANCES PER OCCUPANT
SECTION 1005 MEANS OF EGRESS SIZING
416 SECTION 1006 NUMBER OF EXITS AND EXIT ACCESS DOORWAYS
417 TABLE 1006.2.1 SPACES WITH ONE EXIT OR EXIT ACCESS DOORWAY
418 TABLE 1006.3.3 MINIMUM NUMBER OF EXITS ORACCESS TO EXITS PER STORY
TABLE 1006.3.4(1) STORIES WITH ONE EXIT OR ACCESS TO ONE EXIT FOR R-2 OCCUPANCIES
SECTION 1007 EXIT AND EXIT ACCESS DOORWAY CONFIGURATION
419 TABLE 1006.3.4(2) STORIES WITH ONE EXIT OR ACCESS TO ONE EXIT FOR OTHER OCCUPANCIES
SECTION 1008 MEANS OF EGRESS ILLUMINATION
420 SECTION 1009 ACCESSIBLE MEANS OF EGRESS
423 SECTION 1010 DOORS, GATES AND TURNSTILES
430 TABLE 1010.3.1(1) MAXIMUM DOOR SPEED MANUAL REVOLVING DOORS
TABLE 1010.3.1(2) MAXIMUM DOOR SPEED AUTOMATIC ORPOWER-OPERATED REVOLVING DOORS
432 SECTION 1011 STAIRWAYS
436 SECTION 1012 RAMPS
437 SECTION 1013 EXIT SIGNS
438 SECTION 1014 HANDRAILS
439 SECTION 1015 GUARDS
441 SECTION 1016 EXIT ACCESS
SECTION 1017 EXIT ACCESS TRAVEL DISTANCE
442 TABLE 1017.2 EXIT ACCESS TRAVEL DISTANCE
443 SECTION 1018 AISLES
SECTION 1019 EXIT ACCESS STAIRWAYS AND RAMPS
444 SECTION 1020 CORRIDORS
TABLE 1020.2 CORRIDOR FIRE-RESISTANCE RATING
TABLE 1020.3 MINIMUM CORRIDOR WIDTH
445 SECTION 1021 EGRESS BALCONIES
SECTION 1022 EXITS
446 SECTION 1023 INTERIOR EXIT STAIRWAYS AND RAMPS
448 SECTION 1024 EXIT PASSAGEWAYS
449 SECTION 1025 LUMINOUS EGRESS PATH MARKINGS
450 SECTION 1026 HORIZONTAL EXITS
451 SECTION 1027 EXTERIOR EXIT STAIRWAYS AND RAMPS
SECTION 1028 EXIT DISCHARGE
452 SECTION 1029 EGRESS COURTS
453 SECTION 1030 ASSEMBLY
454 TABLE 1030.6.2 CAPACITY FOR AISLES FOR SMOKE-PROTECTED ASSEMBLY
457 TABLE 1030.13.2.1 SMOKE-PROTECTED OR OPEN-AIR ASSEMBLY AISLE ACCESSWAYS
459 SECTION 1031 EMERGENCY ESCAPE AND RESCUE
462 CHAPTER 11 ACCESSIBILITY
SECTION 1101 GENERAL
SECTION 1102 COMPLIANCE
463 SECTION 1103 SCOPING REQUIREMENTS
464 SECTION 1104 ACCESSIBLE ROUTE
466 SECTION 1105 ACCESSIBLE ENTRANCES
TABLE 1105.1.1 PUBLIC ENTRANCE WITH POWER-OPERATED DOOR
467 SECTION 1106 PARKING AND PASSENGER LOADING FACILITIES
TABLE 1106.2 ACCESSIBLE PARKING SPACES
468 SECTION 1107 RESERVED
SECTION 1108 DWELLING UNITS AND SLEEPING UNITS
471 TABLE 1108.6.1.1 ACCESSIBLE DWELLING UNITS AND SLEEPING UNITS
473 SECTION 1109 SPECIAL OCCUPANCIES
474 TABLE 1109.2.2.1 ACCESSIBLE WHEELCHAIR SPACES
475 TABLE 1109.2.7.1 RECEIVERS FOR ASSISTIVE LISTENING SYSTEMS
TABLE 1109.3 ACCESSIBLE SELF-SERVICE STORAGE FACILITIES
476 SECTION 1110 OTHER FEATURES AND FACILITIES
479 TABLE 1110.13.1 ACCESSIBLE CHECK-OUT AISLES
480 SECTION 1111 RECREATIONAL FACILITIES
SECTION 1112 SIGNAGE
481 SECTION 1113 CLUSTERED MAILBOXES
482 CHAPTER 12 INTERIOR ENVIRONMENT
SECTION 1201 GENERAL
SECTION 1202 VENTILATION
483 TABLE 1202.3 INSULATION FOR CONDENSATION CONTROL
484 SECTION 1203 TEMPERATURE CONTROL
SECTION 1204 LIGHTING
485 SECTION 1205 YARDS OR COURTS
SECTION 1206 SOUND TRANSMISSION
SECTION 1207 ENHANCED CLASSROOM ACOUSTICS
SECTION 1208 INTERIOR SPACE DIMENSIONS
486 SECTION 1209 ACCESS TO UNOCCUPIED SPACES
SECTION 1210 TOILET AND BATHROOM REQUIREMENTS
488 CHAPTER 13 ENERGY EFFICIENCY
SECTION 1301 GENERAL
490 CHAPTER 14 EXTERIOR WALLS
SECTION 1401 GENERAL
SECTION 1402 PERFORMANCE REQUIREMENTS
491 SECTION 1403 MATERIALS
492 SECTION 1404 INSTALLATION OF WALL COVERINGS
TABLE 1404.2 MINIMUM THICKNESS OF WEATHER COVERINGS
493 TABLE 1404.3(1) VAPOR RETARDER MATERIALS AND CLASSES
TABLE 1404.3(2)b, c VAPOR RETARDER OPTIONS
TABLE 1404.3(3) CLASS III VAPOR RETARDERS
TABLE 1404.3(4) CONTINUOUS INSULATION WITH CLASS II VAPOR RETARDER
498 SECTION 1405 COMBUSTIBLE MATERIALS ONTHE EXTERIOR SIDE OF EXTERIOR WALLS
TABLE 1405.1.1.1.2 MINIMUM FIRE SEPARATION FOR COMBUSTIBLE EXTERIOR WALL COVERINGS
499 SECTION 1406 METAL COMPOSITE MATERIALS (MCM)
SECTION 1407 EXTERIOR INSULATION AND FINISH SYSTEMS (EIFS)
500 SECTION 1408 HIGH-PRESSURE DECORATIVE EXTERIOR-GRADE COMPACT LAMINATES (HPL)
501 SECTION 1409 PLASTIC COMPOSITE DECKING
502 CHAPTER 15 ROOF ASSEMBLIES AND ROOFTOP STRUCTURES
SECTION 1501 GENERAL
SECTION 1502 ROOF DRAINAGE
SECTION 1503 WEATHER PROTECTION
SECTION 1504 PERFORMANCE REQUIREMENTS
503 TABLE 1504.2 CLASSIFICATION OF STEEP SLOPE ROOF SHINGLES TESTED IN ACCORDANCE WITH ASTM D3161OR D7158
504 TABLE 1504.9 MINIMUM REQUIRED PARAPET HEIGHT (INCHES) FOR AGGREGATE SURFACED ROOFS
SECTION 1505 FIRE CLASSIFICATION
TABLE 1505.1 MINIMUM ROOF COVERING CLASSIFICATION FOR TYPES OF CONSTRUCTION
505 SECTION 1506 MATERIALS
SECTION 1507 REQUIREMENTS FOR ROOF COVERINGS
506 TABLE 1507.1.1(1 )UNDERLAYMENT TYPES
507 TABLE 1507.1.1(2) UNDERLAYMENT APPLICATION
508 TABLE 1507.1.1(3) UNDERLAYMENT ATTACHMENT
509 TABLE 1507.2.8.2 VALLEY LINING MATERIAL
510 TABLE 1507.3.7 CLAY AND CONCRETE TILE ATTACHMENT
511 TABLE 1507.4.3(1) METAL ROOF COVERINGS
TABLE 1507.4.3(2) MINIMUM CORROSION RESISTANCE
512 TABLE 1507.7.6 SLATE SHINGLE HEADLAP
TABLE 1507.8.5 WOOD SHINGLE MATERIAL REQUIREMENTS
513 TABLE 1507.8 WOOD SHINGLE AND SHAKE INSTALLATION
TABLE 1507.8.7 WOOD SHINGLE WEATHER EXPOSURE AND ROOF SLOPE
514 TABLE 1507.9.6 WOOD SHAKE MATERIAL REQUIREMENTS
TABLE 1507.9.8 WOOD SHAKE WEATHER EXPOSURE AND ROOF SLOPE
515 TABLE 1507.10.2 BUILT-UP ROOFING MATERIAL STANDARDS
TABLE 1507.12.2 SINGLE-PLY ROOFING MATERIAL STANDARDS
516 TABLE 1507.13.3 PROTECTIVE COATING MATERIAL STANDARDS
517 SECTION 1508 ROOF INSULATION
BF] TABLE 1508.2 MATERIAL STANDARDS FOR ROOF INSULATION
SECTION 1509 ROOF COATINGS
TABLE 1509.2 ROOF COATING MATERIAL STANDARDS
SECTION 1510 RADIANT BARRIERS INSTALLED ABOVE DECK
518 SECTION 1511 ROOFTOP STRUCTURES
520 SECTION 1512 REROOFING
522 CHAPTER 16 STRUCTURAL DESIGN
SECTION 1601 GENERAL
SECTION 1602 NOTATIONS
SECTION 1603 CONSTRUCTION DOCUMENTS
523 SECTION 1604 GENERAL DESIGN REQUIREMENTS
524 TABLE 1604.3 DEFLECTION LIMITS
525 SECTION 1605 LOAD COMBINATIONS
526 TABLE 1604.5 RISK CATEGORY OF BUILDINGS AND OTHER STRUCTURES
527 (EQUATIONS 16-1)
(EQUATIONS 16-2)
(EQUATIONS 16-3)
(EQUATIONS 16-4)
(EQUATIONS 16-5)
(EQUATIONS 16-6)
SECTION 1606 DEAD LOADS
SECTION 1607 LIVE LOADS
529 TABLE 1607.1 MINIMUM UNIFORMLY DISTRIBUTED LIVE LOADS, L0, AND MINIMUM CONCENTRATED LIVE LOADS
530 TABLE 1607.1—CONTINUED MINIMUM UNIFORMLY DISTRIBUTED LIVE LOADS, L0,AND MINIMUM CONCENTRATED LIVE LOADS
531 TABLE 1607.1—CONTINUED MINIMUM UNIFORMLY DISTRIBUTED LIVE LOADS, L0, AND MINIMUM CONCENTRATED LIVE LOADS
532 (EQUATION 16-7)
533 TABLE 1607.12.1 LIVE LOAD ELEMENT FACTOR, KLL
(EQUATION 16-8)
(EQUATION 16-9)
534 (EQUATION 16-10)
(EQUATION 16-11)
(EQUATION 16-12)
(EQUATION 16-13)
(EQUATION 16-14)
(EQUATION 16-15)
(EQUATION 16-16)
536 SECTION 1608 SNOW LOADS
TABLE 7.2 GROUND SNOW LOAD ADJUSTMENT
537 TABLE 1608.3 LOCATIONS AND CRITERIA FOR SITE-SPECIFIC GROUND SNOW LOAD STUDY REQUIREMENT
SECTION 1609 WIND LOADS
538 TABLE 1609.3 BASIC DESIGN WIND SPEED, V, FOR RISK CATEGORY I, II, III AND IV BUILDINGS AND OTHER STRUCTURES
539 TABLE 1609.3-CONTINUED BASIC DESIGN WIND SPEED, V, FOR RISK CATEGORY I, II, III AND IV BUILDINGS AND OTHER STRUCTURES
FIGURE 1609.3 OREGON SPECIAL WIND REGIONS
540 TABLE 1609.3.1 WIND SPEED CONVERSIONS
(EQUATION 16-18)
541 SECTION 1610 SOIL LOADS AND HYDROSTATIC PRESSURE
TABLE 1610.1 LATERAL SOIL LOAD
SECTION 1611 RAIN LOADS
(EQUATUION 16-19)
542 FIGURE 1611.1 100-YEAR, 1-HOUR RAINFALL (INCHES) OREGON
SECTION 1612 FLOOD LOADS
543 SECTION 1613 EARTHQUAKE LOADS
544 (EQUATION 16-20)
(EQUATION 16-21)
(EQUATION 16-22)
(EQUATION 16-23)
545 TABLE 1613.2.3(1) VALUES OF SITE COEFFICIENT F
TABLE 1613.2.3(2) VALUES OF SITE COEFFICIENT F
TABLE 1613.2.5(1) SEISMIC DESIGN CATEGORY BASED ON SHORT-PERIOD (0.2 second) RESPONSE ACCELERATION
TABLE 1613.2.5(2) SEISMIC DESIGN CATEGORY BASED ON 1-SECOND PERIOD RESPONSE ACCELERATION
549 SECTION 1614 ATMOSPHERIC ICE LOADS
550 SECTION 1615 TSUNAMI LOADS
Table 6.8-1 Tsunami Important Factorsfor Hydrodynamic and Impact Loads
551 SECTION 1616 STRUCTURAL INTEGRITY
552 FIGURE 1616.3 LONGITUDINAL, PERIMETER, TRANSVERSE AND VERTICAL TIES
(EQUATION 16-24)
(EQUATION 16-25)
554 CHAPTER 17 SPECIAL INSPECTIONS AND TESTS
SECTION 1701 GENERAL
SECTION 1702 NEW MATERIALS
SECTION 1703 APPROVALS
555 SECTION 1704 SPECIAL INSPECTIONS AND TESTS, CONTRACTOR RESPONSIBILITY AND STRUCTURAL OBSERVATION
557 SECTION 1705 REQUIRED SPECIAL INSPECTIONS AND TESTS
558 TABLE 1705.2 REQUIRED VERIFICATION AND INSPECTION OF STEEL CONSTRUCTION
559 TABLE 1705.2.3 REQUIRED SPECIAL INSPECTIONS OF OPEN-WEB STEEL JOISTS AND JOIST GIRDERS
560 TABLE 1705.3 REQUIRED SPECIAL INSPECTIONS AND TESTS OF CONCRETE CONSTRUCTION
561 TABLE 1705.5.3REQUIRED SPECIAL INSPECTIONS OF MASS TIMBER CONSTRUCTION
TABLE 1705.6 REQUIRED SPECIAL INSPECTIONS AND TESTS OF SOILS
562 TABLE 1705.7 REQUIRED SPECIAL INSPECTIONS AND TESTS OF DRIVEN DEEP FOUNDATION ELEMENTS
TABLE 1705.8 REQUIRED SPECIAL INSPECTIONS AND TESTS OF CAST-IN-PLACE DEEP FOUNDATION ELEMENTS
564 TABLE 1705.13.7 REQUIRED INSPECTIONS OF STORAGE RACK SYSTEMS
567 SECTION 1706 DESIGN STRENGTHS OF MATERIALS
568 SECTION 1707 ALTERNATIVE TEST PROCEDURE
SECTION 1708 IN-SITU LOAD TESTS
SECTION 1709 PRECONSTRUCTION LOAD TESTS
570 CHAPTER 18 SOILS AND FOUNDATIONS
SECTION 1801 GENERAL
SECTION 1802 DESIGN BASIS
SECTION 1803 GEOTECHNICAL INVESTIGATIONS
573 SECTION 1804 EXCAVATION, GRADING AND FILL
SECTION 1805 DAMPPROOFING AND WATERPROOFING
575 SECTION 1806 PRESUMPTIVE LOAD-BEARINGVALUES OF SOILS
576 TABLE 1806.2 PRESUMPTIVE LOAD-BEARING VALUES
SECTION 1807 FOUNDATION WALLS, RETAINING WALLSAND EMBEDDED POSTS AND POLES
577 TABLE 1807.1.6.2 CONCRETE FOUNDATION WALLS
578 TABLE 1807.1.6.3(1) PLAIN MASONRY FOUNDATION WALLS
579 TABLE 1807.1.6.3(2) 8-INCH MASONRY FOUNDATION WALLS WITH REINFORCEMENT WHERE d ≥ 5 INCHES
580 TABLE 1807.1.6.3(3) 10-INCH MASONRY FOUNDATION WALLS WITH REINFORCEMENT WHERE d ≥ 6.75 INCHES
581 (EQUATION 18-1)
(EQUATION 18-2)
(EQUATION 18-3)
TABLE 1807.1.6.3(4) 12-INCH MASONRY FOUNDATION WALLS WITH REINFORCEMENT WHERE d ≥ 8.75 INCHES
582 SECTION 1808 FOUNDATIONS
583 FIGURE 1808.7.1 FOUNDATION CLEARANCES FROM SLOPES
584 TABLE 1808.8.1 MINIMUM SPECIFIED COMPRESSIVE STRENGTH f ′c OF CONCRETE OR GROUT
TABLE 1808.8.2 MINIMUM CONCRETE COVER
585 SECTION 1809 SHALLOW FOUNDATIONS
TABLE 1809.7 PRESCRIPTIVE FOOTINGS SUPPORTING WALLS OF LIGHT-FRAME CONSTRUCTION
586 SECTION 1810 DEEP FOUNDATIONS
589 TABLE 1810.3.2.6 ALLOWABLE STRESSES FOR MATERIALS USED IN DEEP FOUNDATION ELEMENTS
591 (EQUATION 18-4)
593 (EQUATION 18-5)
598 SECTION 1811 RADON CONTROL METHODS—PUBLIC BUILDINGS
602 SECTION 1812 RADON CONTROL METHODS—GROUP R-2 AND R-3 OCCUPANCIES
603 FIGURE 1811.3.4 GAS CONVEYANCE PIPING
605 FIGURE 1812.2(1) RADON-RESISTANT CONSTRUCTION FOR BASEMENT FOUNDATIONS
606 FIGURE 1812.2(2) RADON-RESISTANT CONSTRUCTION FOR COMBINATION BASEMENT/CRAWL SPACE FOUNDATIONS
607 FIGURE 1812.2(3) RADON-RESISTANT CONSTRUCTION FOR CRAWL SPACE FOUNDATIONS
608 CHAPTER 19 CONCRETE
SECTION 1901 GENERAL
SECTION 1902 COORDINATION OF TERMINOLOGY
SECTION 1903 SPECIFICATIONS FOR TESTS AND MATERIALS
609 SECTION 1904 DURABILITY REQUIREMENTS
SECTION 1905 MODIFICATIONS TO ACI 318
611 SECTION 1906 FOOTINGS FOR LIGHT-FRAME CONSTRUCTION
SECTION 1907 MINIMUM SLAB PROVISIONS
612 SECTION 1908 SHOTCRETE
614 CHAPTER 20 ALUMINUM
SECTION 2001 GENERAL
SECTION 2002 MATERIALS
616 CHAPTER 21 MASONRY
SECTION 2101 GENERAL
SECTION 2102 NOTATIONS
SECTION 2103 MASONRY CONSTRUCTION MATERIALS
TABLE 2103.2.3 CERAMIC TILE MORTAR COMPOSITIONS
617 SECTION 2104 CONSTRUCTION
SECTION 2105 QUALITY ASSURANCE
SECTION 2106 SEISMIC DESIGN
SECTION 2107 ALLOWABLE STRESS DESIGN
618 (EQUATION 21-1)
SECTION 2108 STRENGTH DESIGN OF MASONRY
SECTION 2109 EMPIRICAL DESIGN OF ADOBE MASONRY
619 (EQUATION 21-2)
TABLE 2109.2.3.1 ALLOWABLE SHEAR ON BOLTS IN ADOBE MASONRY
620 SECTION 2110 GLASS UNIT MASONRY
621 SECTION 2111 MASONRY FIREPLACES
622 FIGURE 2111.12 ILLUSTRATION OF EXCEPTION TO FIREPLACE CLEARANCE PROVISION
623 SECTION 2112 MASONRY HEATERS
SECTION 2113 MASONRY CHIMNEYS
626 FIGURE 2113.16 FLUE SIZES FOR MASONRY CHIMNEYS
627 TABLE 2113.16(1) NET CROSS-SECTIONAL AREA OF ROUND FLUE SIZES
TABLE 2113.16(2) NET CROSS-SECTIONAL AREA OF SQUARE AND RECTANGULAR FLUE SIZES
FIGURE 2113.19 ILLUSTRATION OF EXCEPTION THREE CHIMNEY CLEARANCE PROVISION
SECTION 2114 DRY-STACK MASONRY
628 TABLE 2114.4 GROSS CROSS-SECTIONAL ARE AALLOWABLE STRESS FOR DRY-STACK MASONRY
630 CHAPTER 22 STEEL
SECTION 2201 GENERAL
SECTION 2202 IDENTIFICATION OF STEELFOR STRUCTURAL PURPOSES
SECTION 2203 PROTECTION OF STEELFOR STRUCTURAL PURPOSES
SECTION 2204 CONNECTIONS
SECTION 2205 STRUCTURAL STEEL
631 SECTION 2206 COMPOSITE STRUCTURAL STEEL AND CONCRETE STRUCTURES
SECTION 2207 STEEL JOISTS
632 SECTION 2208 STEEL CABLE STRUCTURES
SECTION 2209 STEEL STORAGE RACKS
SECTION 2210 COLD-FORMED STEEL
SECTION 2211 COLD-FORMED STEEL LIGHT-FRAME CONSTRUCTION
634 CHAPTER 23 WOOD
SECTION 2301 GENERAL
SECTION 2302 DESIGN REQUIREMENTS
SECTION 2303 MINIMUM STANDARDS AND QUALITY
638 FIGURE 2303.4.1.2 (1) PITMR AND PITMDB FOR TRUSS WEB MEMBERS REQUIRING ONE ROW OF PITMR
639 FIGURE 2303.4.1.2(2) ALTERNATIVE INSTALLATION USING BUCKLING REINFORCEMENT FOR TRUSS WEB MEMBERS IN LIEU OF ONE ROW OF PITMR
640 FIGURE 2303.4.1.2(3) PITMR AND PITMDB FOR TRUSS WEB MEMBERS REQUIRING TWO ROWS OF PITMR
641 FIGURE 2303.4.1.2(4) ALTERNATIVE INSTALLATION USING BUCKLING REINFORCEMENT FOR TRUSS WEB MEMBERS IN LIEU OF TWO ROWS OF PITMR
642 FIGURE 2303.4.1.2(5) PITMR AND PITMDB FOR FLAT PORTION OF TOP CHORD IN A PIGGYBACK ASSEMBLY
643 SECTION 2304 GENERAL CONSTRUCTION REQUIREMENTS
644 TABLE 2304.6.1 MAXIMUM ALLOWABLE STRESS DESIGN WIND SPEED, Vasd PERMITTED FOR WOOD STRUCTURAL PANEL WALL SHEATHING USED TO RESIST WIND PRESSURES
TABLE 2304.8(1) ALLOWABLE SPANS FOR LUMBER FLOOR AND ROOF SHEATHING
645 TABLE 2304.8(2) SHEATHING LUMBER, MINIMUM GRADE REQUIREMENTS: BOARD GRADE
TABLE 2304.8(3) ALLOWABLE SPANS AND LOADS FOR WOOD STRUCTURAL PANEL SHEATHING AND SINGLE-FLOOR GRADES CONTINUOUS OVER TWO OR MORE SPANS WITH STRENGTH AXIS PERPENDICULAR TO SUPPORTS
646 TABLE 2304.8(4) ALLOWABLE SPAN FOR WOOD STRUCTURAL PANEL COMBINATION SUBFLOOR-UNDERLAYMENT (SINGLE FLOOR) (Panels Continuous Over Two or More Spans and Strength Axis Perpendicular to Supports)
TABLE 2304.8(5) ALLOWABLE LOAD (PSF) FOR WOOD STRUCTURAL PANEL ROOF SHEATHING CONTINUOUS OVER TWO OR MORE SPANS AND STRENGTH AXIS PARALLEL TO SUPPORTS(PLYWOOD STRUCTURAL PANELS ARE FIVE-PLY, FIVE-LAYER UNLESS OTHERWISE NOTED)
647 TABLE 2304.9.3.2 FASTENING SCHEDULE FOR MECHANICALLY LAMINATED DECKING USING LAMINATIONS OF 2-INCH NOMINAL THICKNESS
649 TABLE 2304.10.2 FASTENING SCHEDULE
650 TABLE 2304.10.2—CONTINUED FASTENING SCHEDULE
651 TABLE 2304.10.2—CONTINUED FASTENING SCHEDULE
652 TABLE 2304.10.2—CONTINUED FASTENING SCHEDULE
653 TABLE 2304.10.2—CONTINUED FASTENING SCHEDULE
654 TABLE 2304.11 MINIMUM DIMENSIONS OF HEAVY TIMBER STRUCTURAL MEMBERS
656 SECTION 2305 GENERAL DESIGN REQUIREMENTS FOR LATERAL FORCE-RESISTING SYSTEMS
TABLE 2305.2(1) VALUES (INCHES) FOR USE IN CALCULATING DIAPHRAGM AND SHEAR WALL DEFLECTION DUE TO FASTENER SLIP (STRUCTURAL I)
(EQUATION 23-1)
(EQUATION 23-2)
657 TABLE 2305.2(2) VALUES OF Gt FOR USE IN CALCULATING DEFLECTION OF WOOD STRUCTURAL PANEL SHEAR WALLS AND DIAPHRAGMS
SECTION 2306 ALLOWABLE STRESS DESIGN
658 TABLE 2306.1 STANDARDS FOR DESIGN AND CONSTRUCTION OF WOOD ELEMENTS IN STRUCTURES USING ALLOWABLE STRESS DESIGN
TABLE 2306.1.4 ALLOWABLE LOADS FOR LUMBER DECKING
659 TABLE 2306.2(1) ALLOWABLE SHEAR VALUES (POUNDS PER FOOT) FOR WOOD STRUCTURAL PANEL DIAPHRAGMS UTILIZING STAPLES WITH FRAMING OF DOUGLAS FIR-LARCH, OR SOUTHERN PINEa FOR WIND OR SEISMIC LOADING
FIGURE 2306.2(1) CASES 1 THROUGH 6 FOR USE WITH TABLE 2306.2(1)
660 TABLE 2306.2(2) ALLOWABLE SHEAR VALUES (POUNDS PER FOOT) FOR WOOD STRUCTURAL PANEL BLOCKED DIAPHRAGMS UTILIZING MULTIPLE ROWS OF STAPLES (HIGH-LOAD DIAPHRAGMS) WITH FRAMING OF DOUGLAS FIR-LARCH OR SOUTHERN PINEa FOR WIND OR SEISMIC LOADING
661 FIGURE 2306.2(2) FASTENER SPACING DIAGRAMS FOR USE WITH TABLE 2306.2(2)
662 TABLE 2306.3(1) ALLOWABLE SHEAR VALUES (POUNDS PER FOOT) FOR WOOD STRUCTURAL PANEL SHEAR WALLS UTILIZING STAPLES WITH FRAMING OF DOUGLAS FIR-LARCH OR SOUTHERN PINE FOR WIND OR SEISMIC LOADING
TABLE 2306.3(2) ALLOWABLE SHEAR VALUES (plf) FOR WIND OR SEISMIC LOADING ON SHEAR WALLS OF FIBERBOARD SHEATHING BOARD CONSTRUCTION UTILIZING STAPLES FOR TYPE V CONSTRUCTION ONLY
663 TABLE 2306.3(3)ALLOWABLE SHEAR VALUES FOR WIND OR SEISMIC FORCES FOR SHEAR WALLS OF LATH ANDPLASTER OR GYPSUM BOARD WOOD FRAMED WALL ASSEMBLIES UTILIZING STAPLES
SECTION 2307 LOAD AND RESISTANCE FACTOR DESIGN
SECTION 2308 CONVENTIONAL LIGHT-FRAME CONSTRUCTION
664 TABLE 2308.2.1 ALLOWABLE STORY HEIGHT
666 TABLE 2308.4.1.1(1) HEADER AND GIRDER SPANSa, b FOR EXTERIOR BEARING WALLS (MAXIMUM SPANS FOR DOUGLAS FIR-LARCH, HEM-FIR, SOUTHERN PINE AND SPRUCE-PINE-FIR AND REQUIRED NUMBER OF JACK STUDS)
667 TABLE 2308.4.1.1(1)—CONTINUED HEADER AND GIRDER SPANS a, b FOR EXTERIOR BEARING WALLS (MAXIMUM SPANS FOR DOUGLAS FIR-LARCH, HEM-FIR, SOUTHERN PINE AND SPRUCE-PINE-FIR AND REQUIRED NUMBER OF JACK STUDS)
668 TABLE 2308.4.1.1(2) HEADER AND GIRDER SPANSa, b FOR INTERIOR BEARING WALLS (MAXIMUM SPANS FOR DOUGLAS FIR-LARCH, HEM-FIR, SOUTHERN PINE AND SPRUCE-PINE-FIR AND REQUIRED NUMBER OF JACK STUDS)
669 TABLE 2308.4.2.1(1) FLOOR JOIST SPANS FOR COMMON LUMBER SPECIES (RESIDENTIAL SLEEPING AREAS, LIVE LOAD = 30 psf, L/Δ = 360)
670 TABLE 2308.4.2.1(1)—CONTINUED FLOOR JOIST SPANS FOR COMMON LUMBER SPECIES (RESIDENTIAL SLEEPING AREAS, LIVE LOAD = 30 psf, L/Δ = 360)
671 TABLE 2308.4.2.1(2) FLOOR JOIST SPANS FOR COMMON LUMBER SPECIES (RESIDENTIAL LIVING AREAS, LIVE LOAD = 40 psf, L/Δ = 360)
672 TABLE 2308.4.2.1(2)—CONTINUED FLOOR JOIST SPANS FOR COMMON LUMBER SPECIES (RESIDENTIAL LIVING AREAS, LIVE LOAD = 40 psf, L/Δ = 360)
673 FIGURE 2308.4.4.1(1) OPENINGS IN FLOOR AND ROOF DIAPHRAGMS
674 FIGURE 2308.4.4.1(2) OPENING LIMITATIONS FOR FLOOR AND ROOF DIAPHRAGMS
FIGURE 2308.4.4.2 PORTIONS OF FLOOR LEVEL OFFSET VERTICALLY
TABLE 2308.5.1 SIZE, HEIGHT AND SPACING OF WOOD STUDS
675 FIGURE 2308.5.5.1(1) SINGLE-MEMBER HEADER IN EXTERIOR BEARING WALL
FIGURE 2308.5.5.1(2) ALTERNATIVE SINGLE-MEMBER HEADER WITHOUT CRIPPLE
676 TABLE 2308.5.11 MINIMUM THICKNESS OF WALL SHEATHING
677 FIGURE 2308.6.1 BASIC COMPONENTS OF THE LATERAL BRACING SYSTEM
678 TABLE 2308.6.1 WALL BRACING REQUIREMENTS
679 TABLE 2308.6.3(1) BRACING METHODS
680 TABLE 2308.6.3(2) EXPOSED PLYWOOD PANEL SIDING
TABLE 2308.6.3(3) WOOD STRUCTURAL PANEL WALL SHEATHING (NOT EXPOSED TO WEATHER, STRENGTH AXIS PARALLEL OR PERPENDICULAR TO STUDS EXCEPT AS INDICATED)
TABLE 2308.6.3(4) ALLOWABLE SPANS FOR PARTICLEBOARD WALL SHEATHING (NOT EXPOSED TO WEATHER, LONG DEMENSION OF THE PARALLEL OR PERPENDICULAR TO STUDS)
681 TABLE 2308.6.3(5) HARDBOARD SIDING
682 FIGURE 2308.6.5.1 ALTERNATE BRACED WALL PANEL (ABW)
683 FIGURE 2308.6.5.2 PORTAL FRAME WITH HOLD-DOWNS (PFH)
684 FIGURE 2308.6.7.2(1) BRACED WALL LINE TOP PLATE CONNECTION
685 FIGURE 2308.6.7.2(2) BRACED WALL PANEL TOP PLATE CONNECTION
686 FIGURE 2308.6.8.2(1) ROOF IN SDC D OR E NOT SUPPORTED ON ALL EDGES
FIGURE 2308.6.8.2(2) ROOF EXTENSION IN SDC D OR E BEYOND BRACED WALL LINE
687 FIGURE 2308.6.8.3 STEPPED FOOTING CONNECTION DETAILS
689 TABLE 2308.7.5 REQUIRED RATING OF APPROVED UPLIFT CONNECTORS (POUNDS)
690 SECTION 2309 WOOD FRAME CONSTRUCTION MANUAL
691 TABLE 2308.7.1(1) CEILING JOIST SPANS FOR COMMON LUMBER SPECIES (UNINHABITABLE ATTICS WITHOUT STORAGE, LIVE LOAD = 10 psf, L/Δ = 240)
692 TABLE 2308.7.1(1)—CONTINUED CEILING JOIST SPANS FOR COMMON LUMBER SPECIES (UNINHABITABLE ATTICS WITHOUT STORAGE, LIVE LOAD = 10 psf, L/Δ = 240)
693 TABLE 2308.7.1(2) CEILING JOIST SPANS FOR COMMON LUMBER SPECIES (UNINHABITABLE ATTICS WITH LIMITED STORAGE, LIVE LOAD = 20 psf, L/Δ = 240)
694 TABLE 2308.7.1(2)—CONTINUED CEILING JOIST SPANS FOR COMMON LUMBER SPECIES (UNINHABITABLE ATTICS WITH LIMITED STORAGE, LIVE LOAD = 20 psf, L/Δ = 240)
695 TABLE 2308.7.2(1) RAFTER SPANS FOR COMMON LUMBER SPECIES (ROOF LIVE LOAD = 20PSF, CEILING NOT ATTACHED TO RAFTERS, L/Δ = 180)
696 TABLE 2308.7.2(1)—CONTINUED RAFTER SPANS FOR COMMON LUMBER SPECIES (ROOF LIVE LOAD = 20PSF, CEILING NOT ATTACHED TO RAFTERS, L/Δ = 180)
697 TABLE 2308.7.2(2) RAFTER SPANS FOR COMMON LUMBER SPECIES (ROOF LIVE LOAD = 20 PSF, CEILING ATTACHED TO RAFTERS, L/Δ = 240)
698 TABLE 2308.7.2(2)—CONTINUED RAFTER SPANS FOR COMMON LUMBER SPECIES (ROOF LIVE LOAD = 20 PSF, CEILING ATTACHED TO RAFTERS, L/Δ = 240)
699 TABLE 2308.7.2(3) RAFTER SPANS FOR COMMON LUMBER SPECIES(GROUNG SNOW LOAD = 30 PSF, CELING NOT ATTACHED TO RAFTERS, L/Δ = 180)
700 TABLE 2308.7.2(3)—CONTINUED RAFTER SPANS FOR COMMON LUMBER SPECIES (GROUNG SNOW LOAD = 30 PSF, CELING NOT ATTACHED TO RAFTERS, L/Δ = 180)
701 TABLE 2308.7.2(4) RAFTER SPANS FOR COMMON LUMBER SPECIES (GROUND SNOW LOAD = 50 PSF, CELING NOT ATTCHED TO RAFTERS, L/Δ = 180)
702 TABLE 2308.7.2(4)—CONTINUED RAFTER SPANS FOR COMMON LUMBER SPECIES (GROUND SNOW LOAD = 50 PSF, CELING NOT ATTCHED TO RAFTERS, L/Δ = 180)
703 TABLE 2308.7.2(5) RAFTER SPANS FOR COMMON LUMBER SPECIES(GROUND SNOW LOAD = 30 PSF, CEILING ATTACHED TO RAFTERS, L/Δ = 240)
704 TABLE 2308.7.2(5)— CONTINUED RAFTER SPANS FOR COMMON LUMBER SPECIES (GROUND SNOW LOAD = 30 PSF, CEILING ATTACHED TO RAFTERS, L/Δ = 240)
705 TABLE 2308.7.2(6) RAFTER SPANS FOR COMMON LUMBER SPECIES(GROUND SNOW LOAD = 50 PSF, CEILING ATTACHED TO RAFTERS, L/Δ = 240)
706 TABLE 2308.7.2(6)—CONTINUED RAFTER SPANS FOR COMMON LUMBER SPECIES (GROUND SNOW LOAD = 50 PSF, CEILING ATTACHED TO RAFTERS, L/Δ = 240)
TABLE 2308.7.2(7) RAFTER SPAN ADJUSTMENT FACTOR
707 TABLE 2308.7.3.1 RAFTER TIE CONNECTIONS
708 TABLE 2308.7.3.1(1) HEEL JOINT CONNECTION ADJUSTMENT FACTORS
TABLE 2308.7.12 ALLOWABLE SPANS FOR 2-INCH TONGUE-AND-GROOVE DECKING
709 TABLE 2308.7.12—CONTINUED ALLOWABLE SPANS FOR 2-INCH TONGUE-AND-GROOVE DECKING
710 CHAPTER 24 GLASS AND GLAZING
SECTION 2401 GENERAL
SECTION 2402 GLAZING REPLACEMENT
SECTION 2403 GENERAL REQUIREMENTS FOR GLASS
SECTION 2404 WIND, SNOW, SEISMIC AND DEAD LOADS ON GLASS
(EQUATION 24-1)
(EQUATION 24-2)
(EQUATION 24-3)
(EQUATION 24-4)
711 (EQUATION 24-5)
(EQUATION 24-6)
(EQUATION24-7)
(EQUATION 24-8)
(EQUATION 24-9)
(EQUATION 24-10)
(EQUATION 24-11)
712 (EQUATION 24-12)
SECTION 2405 SLOPED GLAZING AND SKYLIGHTS
713 (EQUATION 24-13)
(EQUATION 24-14)
(EQUATION 24-15)
SECTION 2406 SAFETY GLAZING
714 TABLE 2406.2(1) MINIMUM CATEGORY CLASSIFICATION OF GLAZING USING CPSC 16 CFR PART 1201
TABLE 2406.2(2) MINIMUM CATEGORY CLASSIFICATION OF GLAZING USING ANSI Z97.1
715 SECTION 2407 GLASS IN HANDRAILS AND GUARDS
SECTION 2408 GLAZING IN ATHLETIC FACILITIES
716 SECTION 2409 GLASS IN WALKWAYS, ELEVATOR HOISTWAYS AND ELEVATOR CARS
718 CHAPTER 25 GYPSUM BOARD, GYPSUM PANEL PRODUCTS AND PLASTER
SECTION 2501 GENERAL
SECTION 2502 PERFORMANCE
SECTION 2503 INSPECTION
SECTION 2504 VERTICAL AND HORIZONTAL ASSEMBLIES
SECTION 2505 SHEAR WALL CONSTRUCTION
SECTION 2506 GYPSUM BOARD ANDGYPSUM PANEL PRODUCT MATERIALS
SECTION 2507 LATHING AND PLASTERING
719 TABLE 2506.2 GYPSUM BOARD AND GYPSUM PANEL PRODUCTS MATERIALS AND ACCESSORIES
TABLE 2507.2 LATH, PLASTERING MATERIALS AND ACCESSORIES
720 SECTION 2508 GYPSUM CONSTRUCTION
TABLE 2508.1 INSTALLATION OF GYPSUM CONSTRUCTION
TABLE 2508.6 SHEAR CAPACITY FOR HORIZONTAL WOOD-FRAME GYPSUM BOARD DIAPHRAGM CEILING ASSEMBLIES
721 SECTION 2509 SHOWERS AND WATER CLOSETS
TABLE 2509.2 BACKERBOARD MATERIALS
SECTION 2510 LATHING AND FURRING FOR CEMENT PLASTER (STUCCO)
722 SECTION 2511 INTERIOR PLASTER
TABLE 2511.1.1 INSTALLATION OF PLASTER CONSTRUCTION
SECTION 2512 EXTERIOR PLASTER
723 TABLE 2512.6 CEMENT PLASTERS
SECTION 2513 EXPOSED AGGREGATE PLASTER
SECTION 2514 REINFORCED GYPSUM CONCRETE
726 CHAPTER 26 PLASTIC
SECTION 2601 GENERAL
SECTION 2602 FINISH AND TRIM
SECTION 2603 FOAM PLASTIC INSULATION
729 FIGURE 2603.8 TERMITE INFESTATION PROBABILITY MAP
730 TABLE 2603.12.1 CLADDING MINIMUM FASTENING REQUIREMENTS FOR DIRECTATTACHMENT OVER FOAM PLASTIC SHEATHING TO SUPPORT CLADDING WEIGHT
731 TABLE 2603.12.2 FURRING MINIMUM FASTENING REQUIREMENTS FOR APPLICATION OVER FOAM PLASTIC SHEATHING TO SUPPORT CLADDING WEIGHT
SECTION 2604 INTERIOR FINISH AND TRIM
732 TABLE 2603.13.1 CLADDING MINIMUM FASTENING REQUIREMENTS FOR DIRECT ATTACHMENT OVER FOAM PLASTIC SHEATHING TO SUPPORT CLADDING WEIGHT
SECTION 2605 PLASTIC VENEER
SECTION 2606 LIGHT-TRANSMITTING PLASTICS
733 TABLE 2603.13.2 FURRING MINIMUM FASTENING REQUIREMENTS FOR APPLICATION OVER FOAM PLASTIC SHEATHING TO SUPPORT CLADDING WEIGHT
734 SECTION 2607 LIGHT-TRANSMITTING PLASTIC WALL PANELS
735 TABLE 2607.4 AREA LIMITATION AND SEPARATION REQUIREMENTS FOR LIGHT-TRANSMITTING PLASTIC WALL PANELS
SECTION 2608 LIGHT-TRANSMITTING PLASTIC GLAZING
SECTION 2609 LIGHT-TRANSMITTING PLASTIC ROOF PANELS
736 TABLE 2609.4 AREA LIMITATIONS FOR LIGHT-TRANSMITTING PLASTIC ROOF PANELS
SECTION 2610 LIGHT-TRANSMITTINGPLASTIC SKYLIGHT GLAZING
737 SECTION 2611 LIGHT-TRANSMITTING PLASTIC INTERIOR SIGNS
SECTION 2612 PLASTIC COMPOSITES
SECTION 2613 FIBER-REINFORCED POLYMER
738 SECTION 2614 REFLECTIVE PLASTIC CORE INSULATION
740 CHAPTER 27 ELECTRICAL
SECTION 2701 GENERAL
SECTION 2702 EMERGENCY AND STAND BY POWER SYSTEMS
741 SECTION 2703 ELECTRICAL ROOM SIGNAGE
742 CHAPTER 28 MECHANICAL SYSTEMS
SECTION 2801 GENERAL
SECTION 2802 FUEL OIL STORAGE SYSTEMS
744 TABLE 2802.8.2 MINIMUM EXHAUST RATE
746 CHAPTER 29 PLUMBING SYSTEMS
SECTION 2901 GENERAL
SECTION 2902 MINIMUM PLUMBING FACILITIES
747 TABLE 2902.1 MINIMUM NUMBER OF REQUIRED PLUMBING FIXTURES (SEE SECTIONS 2902.1.1 AND 2902.2)
748 TABLE 2902.1—CONTINUED MINIMUM NUMBER OF REQUIRED PLUMBING FIXTURES (SEE SECTIONS 2902.1.1 AND 2902.2)
750 CHAPTER 30 ELEVATORS AND CONVEYING SYSTEMS
SECTION 3001 GENERAL
SECTION 3002 HOISTWAY ENCLOSURES
SECTION 3003 EMERGENCY OPERATIONS
751 SECTION 3004 CONVEYING SYSTEMS
SECTION 3005 MACHINE ROOMS
752 SECTION 3006 ELEVATOR LOBBIES AND HOISTWAY OPENING PROTECTION
753 SECTION 3007 FIRE SERVICE ACCESS ELEVATOR
754 FIGURE 3007.6.5 FIRE SERVICE ACCESS ELEVATOR SYMBOL
SECTION 3008 OCCUPANT EVACUATION ELEVATORS
758 CHAPTER 31 SPECIAL CONSTRUCTION
SECTION 3101 GENERAL
SECTION 3102 MEMBRANE STRUCTURES
760 SECTION 3103 TEMPORARY STRUCTURES
SECTION 3104 PEDESTRIAN WALKWAYS AND TUNNELS
762 SECTION 3105 AWNINGS AND CANOPIES
SECTION 3106 MARQUEES
SECTION 3107 SIGNS
SECTION 3108 TELECOMMUNICATION AND BROADCAST TOWERS
SECTION 3109 SWIMMING POOLS, SPAS AND HOT TUBS
763 SECTION 3110 AUTOMATIC VEHICULAR GATES
SECTION 3111 SOLAR ENERGY SYSTEMS
767 FIGURE 3111.3.5.3(1) BRACED ROOF RAFTERS FOR PRESCRIPTIVE ROOFTOP-MOUNTED PHOTOVOLTAIC PANEL SYSTEMS
768 FIGURE 3111.3.5.3(2) PHOTOVOLTAIC RACKING AND MODULE ATTACHMENT TO RAFTERS OR TRUSSES
FIGURE 3111.3.5.3(3) PHOTOVOLTAIC RACKING AND MODULE ATTACHMENT TO BLOCKINGS
769 SECTION 3112 GREENHOUSES
SECTION 3113 TEMPORARY SPECIAL EVENT STRUCTURES
770 SECTION 3114 INTERMODAL SHIPPING CONTAINERS
773 TABLE 3114.8.5.3 ALLOWABLE SHEAR VALUES FOR INTERMODAL SHIPPING CONTAINER CORRUGATED STEEL WALLS FOR WIND OR SEISMIC LOADING
FIGURE 3114.8.5.3(1) BRACING UNIT DISTRIBUTION—MAXIMUM LINEAR LENGTH
774 FIGURE 3114.8.5.3(2) BRACING UNIT DISTRIBUTION—MINIMUM LINEAR LENGTH
FIGURE 3114.8.5.3(3) BRACING UNIT DISTRIBUTION—BOUNDARY ELEMENTS
775 FIGURE 3114.8.5.3(4) BRACING UNIT DISTRIBUTION—PENETRATION LIMITATIONS
776 CHAPTER 32 ENCROACHMENTS INTO THE PUBLIC RIGHT-OF-WAY
778 CHAPTER 33 SAFEGUARDS DURING CONSTRUCTION
SECTION 3301 GENERAL
SECTION 3302 CONSTRUCTION SAFEGUARDS
SECTION 3303 DEMOLITION
SECTION 3304 SITE WORK
SECTION 3305 RESERVED
SECTION 3306 RESERVED
SECTION 3307 PROTECTION OF ADJOINING PROPERTY
779 SECTION 3308 TEMPORARY USE OF STREETS, ALLEYS AND PUBLIC PROPERTY
SECTION 3309 FIRE EXTINGUISHERS
SECTION 3310 MEANS OF EGRESS
SECTION 3311 STANDPIPES
SECTION 3312 AUTOMATIC SPRINKLER SYSTEM
SECTION 3313 WATER SUPPLY FOR FIRE PROTECTION
SECTION 3314 FIRE WATCH DURING CONSTRUCTON
780 CHAPTER 34 EXISTING BUILDINGS
SECTION 3401 GENERAL
SECTION 3402 DEFINITIONS
SECTION 3403 PROVISIONS FOR ALL COMPLIANCE METHODS
782 TABLE 3403.4.3.1 PERFORMANCE OBJECTIVES FOR USE IN ASCE 41 FOR COMPLIANCE WITH FULL SEISMIC FORCES
783 TABLE 3403.4.3.2 PERFORMANCE OBJECTIVES FOR USE IN ASCE 41 FOR COMPLIANCE WITH REDUCED SEISMIC FORCES
788 SECTION 3404 REPAIRS
789 SECTION 3405 PRESCRIPTIVE COMPLIANCE METHOD
794 SECTION 3406 CLASSIFICATION OF WORK
SECTION 3407 ALTERATIONS—LEVEL 1
795 SECTION 3408 ALTERATIONS—LEVEL 2
800 TABLE 3408.4.4.1.1(1) STORIES WITH ONE EXIT OR ACCESS TO ONE EXIT FOR R-2 OCCUPANCIES
801 TABLE 3408.4.4.1.1(2) STORIES WITH ONE EXIT OR ACCESS TO ONE EXIT FOR OTHER OCCUPANCIES
804 SECTION 3409 ALTERATIONS—LEVEL 3
806 SECTION 3410 CHANGE OF OCCUPANCY
808 TABLE 3410.11.5 MEANS OF EGRESS HAZARD CATEGORIES
809 TABLE 3410.11.6 HEIGHTS AND AREAS HAZARD CATEGORIES
TABLE 3410.11.7 EXPOSURE OF EXTERIOR WALLS HAZARD CATEGORIES
810 SECTION 3411 ADDITIONS
811 SECTION 3412 HISTORIC BUILDINGS
814 SECTION 3413 PERFORMANCE COMPLIANCE METHODS
815 (EQUATION 34-1)
(EQUATION 34-2)
(EQUATION 34-3)
816 (EQUATION 34-4)
(EQUATION 34-5)
TABLE 3413.1.6.3 COMPARTMENTATION VALUES
TABLE 3413.1.6.4 SEPARATION VALUES
817 TABLE 3413.1.6.5 CORRIDOR WALL VALUES
TABLE 3413.1.6.6(1) VERTICAL OPENING PROTECTION VALUE
TABLE 3413.1.6.6(2) CONSTRUCTION-TYPE FACTOR
(EQUATION 34-6)
818 TABLE 3413.1.6.8 AUTOMATIC FIRE DETECTION VALUES
TABLE 3413.1.6.9 FIRE ALARM SYSTEM VALUES
TABLE 3413.1.6.10 SMOKE CONTROL VALUES
819 TABLE 3413.1.6.11 MEANS OF EGRESS VALUES
TABLE 3413.1.6.12 DEAD-END VALUES
820 (EQUATION 34-7)
TABLE 3413.1.6.14 ELEVATOR CONTROL VALUES
TABLE 3413.1.6.15 MEANS OF EGRESS EMERGENCY LIGHTING VALUES
821 TABLE 3413.1.6.16 MIXED OCCUPANCY VALUES
TABLE 3413.1.6.17 SPRINKLER SYSTEM VALUES
TABLE 3413.1.6.18 STANDPIPE SYSTEM VALUES
822 TABLE 3413.1.6.19 INCIDENTAL USE AREA VALUES
TABLE 3413.1.6.20 SMOKE COMPARTMENTATION VALUES
TABLE 3413.1.6.21.1 CARE RECIPIENT ABILITY VALUES
TABLE 3413.1.6.21.2 CARE RECIPIENT CONCENTRATION VALUES
823 TABLE 3413.1.6.21.3 ATTENDANT-TO-CARE RECIPIENTS RATIO VALUES
TABLE 3413.1.8 MANDATORY SAFETY SCORES
SECTION 3414 RELOCATED OR MOVED BUILDINGS
SECTION 3415 CONSTRUCTION SAFEGUARDS
824 TABLE 3413.1.7 SUMMARY SHEET—BUILDING CODE
825 TABLE 3413.1.9EVALUATION FORMULAS
826 CHAPTER 35 REFERENCED STANDARDS
AA
AAMA
ACI
AISC
827 AISI
ANSI
828 APA
829 ASABE
ASCE/SEI
830 ASHRAE
ASME
ASSP
ASTM
842 AWC
AWCI
AWPA
843 AWS
BHMA
CEN
CGA
CPA
844 CPSC
CSA
CSSB
DASMA
DHA
845 DOC
DOL
DOTn
DOTy
EN
846 FM
GA
ICC
847 ISO
MHI
NAAMM
NCMA
NFPA
851 PCI
PTI
RMI
SBCA
SDI
852 SJI
SPRI
SRCC
TIA
TMS
853 TPI
UL
856 ULC
WCLIB
WDMA
WRI
858 APPENDIX A EMPLOYEE QUALIFICATIONS
860 APPENDIX B BOARD OF APPEALS
862 APPENDIX C GROUP U—AGRICULTURAL BUILDINGS
SECTION C101 GENERAL
SECTION C102 ALLOWABLE HEIGHT AND AREA
TABLE C102.1 BASIC ALLOWABLE AREA FOR A GROUP U, ONE STORY IN HEIGHT AND MAXIMUM HEIGHT OF SUCH OCCUPANCY
SECTION C103 MIXED OCCUPANCIES
SECTION C104 EXITS
864 APPENDIX D FIRE DISTRICTS
866 APPENDIX E SUPPLEMENTARY ACCESSIBILITY REQUIREMENTS
868 APPENDIX F RODENTPROOFING
SECTION F101 GENERAL
870 APPENDIX G FLOOD-RESISTANT CONSTRUCTION
872 APPENDIX H SIGNS
SECTION H101 GENERAL
SECTION H102 DEFINITIONS
SECTION H103 LOCATION
SECTION H104 IDENTIFICATION
873 SECTION H105 DESIGN AND CONSTRUCTION
SECTION H106 ELECTRICAL
SECTION H107 COMBUSTIBLE MATERIALS
SECTION H108 ANIMATED DEVICES
SECTION H109 GROUND SIGNS
874 SECTION H110 ROOF SIGNS
SECTION H111 WALL SIGNS
SECTION H112 PROJECTING SIGNS
875 SECTION H113 MARQUEE SIGNS
SECTION H114 PORTABLE SIGNS
SECTION H115 THICKNESS OF SIGNS
TABLE H115.1(1) SIZE, THICKNESS AND TYPE OF GLASS PANELS IN SIGNS
TABLE H115.1(2) THICKNESS OF PROJECTION SIGN
SECTION H116 REFERENCED STANDARDS
TABLE H116.1 REFERENCED STANDARDS
876 APPENDIX I PATIO COVERS
SECTION I101 GENERAL
SECTION I102 DEFINITION
SECTION I103 EXTERIOR WALLS AND OPENINGS
SECTION I104 HEIGHT
SECTION I105 STRUCTURAL PROVISIONS
878 APPENDIX J GRADING
880 APPENDIX K ADMINISTRATIVE PROVISIONS
882 APPENDIX L EARTHQUAKE RECORDING INSTRUMENTATION
884 APPENDIX M TSUNAMI-GENERATED FLOOD HAZARDS
886 APPENDIX N REPLICABLE BUILDINGS
888 APPENDIX O PERFORMANCE-BASED APPLICATION
SECTION O101 GENERAL
890 INDEX
930 RESOURCE A RECOMMENDED PRACTICES FOR REMOTE VIRTUAL INSPECTIONS (RVI)
932 RECOMMENDED PRACTICES FOR REMOTE VIRTUAL
933 COPYRIGHT
934 TABLE OF CONTENTS
936 PREFACE
937 ABOUT THE INTERNATIONAL CODE COUNCIL®
938 1.0 INTRODUCTION
PURPOSE AND SCOPE
2.0 DEFINITIONS AND ACRONYMS
3.0 REMOTE VIRTUAL INSPECTION PROCESS
939 CUSTOMER: REQUESTING A REMOTE VIRTUAL INSPECTION
940 AHJ: SCHEDULING REMOTE VIRTUAL INSPECTION
941 CUSTOMER: PREPARE FOR REMOTE VIRTUAL INSPECTION
CUSTOMER: PREPARE TO RECEIVE REMOTE VIRTUAL INSPECTION CALL
942 WHAT TO EXPECT DURING THE INSPECTION
INSPECTION RESULTS
943 MAINTAINING RECORDS OF INSPECTIONS
4.0 TRAINING AND COMMUNICATION
STAFF TRAINING
944 CUSTOMER/APPLICANT
ADDITIONAL CONSIDERATIONS
945 5.0 APPENDIX A (EXAMPLES OF POTENTIAL ACTIVITIES)
948 ICC DIGITAL CODES LIBRARY
950 ICC ADDITIONAL CODE RESOURCES FROM ICC
951 ICC TRAINING
952 ICC ASSESSMENT CENTER
953 ICC DIGITAL CODES PREMIUM
OR StructuralSpecialtyCode 2022 1stptg
$73.75