SMACNA ArchitecturalSheetMetalManual 7thEdition 2012
$187.42
Architectural Sheet Metal Manual, 7th Edition
Published By | Publication Date | Number of Pages |
SMACNA | 2012 | 542 |
This completely revised publication contains the most comprehensive set of recommended practices available for proper design and installation of custom-fabricated architectural sheet metal including roof drainage system design for scuppers, gutters and downspouts. Features more details in the historical restoration section on skylights, cornices and spires; new moisture and maintenance guide with underlayments; mechanical fasteners and soldering guidance; and enhanced metals selection data. Offers new construction techniques and alternative methods of design and installation reflecting climatic conditions and rainfall rates. An upfront, fast โlook-upโ key speeds information retrieval. Also covers flashing, metal roofs, copings, gravel-stop fascia. Includes wind uplift pressure test reports confirming superior performance of custom-fabricated metal roofing. Applies to commercial, industrial and residential buildings
PDF Catalog
PDF Pages | PDF Title |
---|---|
5 | FOREWORD |
6 | ARCHITECTURAL SHEET METAL TASK FORCE |
7 | NOTICE TO USERS OF THIS PUBLICATION |
10 | CHAPTER RP ROOF PLANS TYPICAL METAL ROOF PLAN Table RP-1 Metal Roof Plan ” Fast Lookup Keys to Architectural Elements |
11 | FIGURE RP-1 TYPICAL METAL ROOF PLAN |
12 | TYPICAL SHINGLE/TILE/SLATE-ROOF PLAN Table RP-2 Shingle/Tile/Slate-Roof Plan ” Fast Lookup Keys to Architectural Elements |
13 | FIGURE RP-2 TYPICAL SHINGLE/TILE/SLATE-ROOF PLAN |
17 | TABLE OF CONTENTS |
31 | CHAPTER 1 ROOF DRAINAGE SYSTEMS DESIGN OF ROOF DRAINAGE SYSTEMS Table 1-1 Design Areas for Pitched Roofs |
32 | Table 1-2 Rainfall Data and Drainage Factors |
33 | Table 1-2 Rainfall Data and Drainage Factors (Continued) |
34 | Table 1-3 Dimensions of Standard Downspouts |
35 | GUTTER SIZING |
36 | Table 1-4 Sloped Roof Gutters Maximum Roof Area for Gutters |
37 | CHART 1-1 WIDTH OF RECTANGULAR GUTTERS FOR GIVEN ROOF AREAS AND RAINFALL INTENSITIES |
38 | CHART 1-2 HALF ROUND GUTTER SELECTION WIDTH REQUIRED FOR GIVEN ROOF AREAS AND RAINFALL INTENSITIES |
40 | RECTANGULAR GUTTER DESIGN |
41 | Table 1-5 Recommended Minimum Gages For Gutter FIGURE 1-1 RECTANGULAR GUTTER DESIGN |
42 | RECTANGULAR GUTTER STYLES |
43 | FIGURE 1-2 RECTANGULAR GUTTER STYLES |
44 | MANUFACTURED HALF ROUND AND OGEE GUTTERS |
45 | FIGURE 1-3 MANUFACTURED HALF ROUND AND OGEE GUTTERS |
46 | BUILT-IN GUTTER DESIGN |
47 | FIGURE 1-4 BUILT-IN GUTTER DESIGN |
48 | Table 1-6 Maximum Distance Between Expansion Joint And Downspout In Feet (Meters) For Built-In Gutter |
50 | ALLOWANCES FOR GUTTER EXPANSION Table 1-7 Installation Values For โEโย of Figures 1-5, 1-6, 1-7, 1-8, 1-9 and 1-10 |
51 | FIGURE 1-5 ALLOWANCES FOR GUTTER EXPANSION |
52 | LAP TYPE GUTTER EXPANSION JOINT |
53 | FIGURE 1-6 LAP TYPE GUTTER EXPANSION JOINT |
54 | BUTT TYPE GUTTER EXPANSION JOINT |
55 | FIGURE 1-7 BUTT TYPE GUTTER EXPANSION JOINT |
56 | BUILT-IN GUTTER EXPANSION JOINT |
57 | FIGURE 1-8 BUILT-IN GUTTER EXPANSION JOINT |
58 | BUILT-IN GUTTER EXPANSION JOINT โ AT WALL |
59 | FIGURE 1-9 BUILT-IN GUTTER EXPANSION JOINT โ AT WALL |
60 | BUILT-IN EXPANSION JOINT โ HEAVY GAGE GUTTER |
61 | FIGURE 1-10 BUILT-IN EXPANSION JOINT โ HEAVY GAGE GUTTER |
62 | COMBINATION SCUPPER AND GUTTER |
63 | FIGURE 1-11 COMBINATION SCUPPER AND GUTTER |
64 | HANGING GUTTER INSTALLATIONS โ (GENERAL) HANGING GUTTER INSTALLATIONS โ GENERAL Table 1-8 Recommended Sizes โ Gutter Brackets or Straps |
65 | FIGURE 1-12 HANGING GUTTER INSTALLATIONS โ GENERAL |
66 | HANGING GUTTER INSTALLATIONS โ BRACKET SUPPORT |
67 | FIGURE 1-13 HANGING GUTTER INSTALLATIONS โ BRACKET SUPPORT |
68 | HANGING GUTTER INSTALLATIONS โ ALTERNATE SUPPORTS |
69 | FIGURE 1-14 HANGING GUTTER INSTALLATIONS โ ALTERNATE SUPPORTS |
70 | CONCEALED HANGING GUTTERS |
71 | FIGURE 1-15 CONCEALED HANGING GUTTERS |
72 | HANGING GUTTER INSTALLATIONS โ HEAVY GUTTER |
73 | FIGURE 1-16 HANGING GUTTER INSTALLATIONS โ HEAVY GUTTER |
74 | HANGING GUTTER INSTALLATIONS โ SLOPED ROOF |
75 | FIGURE 1-17 HANGING GUTTER INSTALLATIONS โ SLOPED ROOF |
76 | HANGING GUTTER INSTALLATIONS โ SLOPED ROOF |
77 | FIGURE 1-18 HANGING GUTTER INSTALLATIONS โ SLOPED ROOF |
78 | HANGING GUTTER INSTALLATIONS โ SLOPED ROOF |
79 | FIGURE 1-19 HANGING GUTTER INSTALLATIONS โ SLOPED ROOF |
80 | HANGING GUTTER INSTALLATIONS โ HALF ROUND |
81 | FIGURE 1-20 HANGING GUTTER INSTALLATIONS โ HALF ROUND |
82 | BUILT-IN GUTTER INSTALLATION |
83 | FIGURE 1-21 BUILT-IN GUTTER INSTALLATION |
84 | WATER DIVERTER DESIGN AND INSTALLATION |
85 | FIGURE 1-22 WATER DIVERTER DESIGN AND INSTALLATION |
86 | BUILT-IN GUTTER INSTALLATION |
87 | FIGURE 1-23 BUILT-IN GUTTER INSTALLATION |
88 | GUTTER ACCESSORIES โ SCREENS AND OUTLETS |
89 | FIGURE 1-24 GUTTER ACCESSORIES โ SCREENS AND OUTLETS |
90 | CONDUCTOR HEADS โ TYPICAL |
91 | FIGURE 1-25 CONDUCTOR HEADS โ TYPICAL |
92 | SCUPPER DESIGN AND INSTALLATION |
93 | FIGURE 1-26 SCUPPER DESIGN AND INSTALLATION |
94 | SCUPPER DESIGN AND INSTALLATION |
95 | FIGURE 1-27 SCUPPER DESIGN AND INSTALLATION |
96 | SCUPPER โ THROUGH FASCIA WITH CONDUCTOR HEAD |
97 | FIGURE 1-28 SCUPPER โ THROUGH FASCIA WITH CONDUCTOR HEAD |
98 | SCUPPER โ DESIGN AND INSTALLATION |
99 | FIGURE 1-29 SCUPPER โ DESIGN AND INSTALLATION |
100 | SCUPPER โ OVERFLOW TYPE โ DESIGN AND INSTALLATION |
101 | FIGURE 1-30 SCUPPER โ OVERFLOW TYPE โ DESIGN AND INSTALLATION |
102 | DOWNSPOUTS MANUFACTURED Table 1-9 Dimensions and Minimum Gages of Standard Downspouts |
103 | FIGURE 1-31 DOWNSPOUTS – MANUFACTURED |
104 | DOWNSPOUTS โ SHOP FABRICATED |
105 | FIGURE 1-32 DOWNSPOUTS โ SHOP FABRICATED |
106 | DOWNSPOUT โ GUTTER CONNECTIONS |
107 | FIGURE 1-33 DOWNSPOUT โ GUTTER CONNECTIONS |
108 | DOWNSPOUTS – HANGER DESIGN |
109 | FIGURE 1-34 DOWNSPOUTS – HANGER DESIGN |
110 | SHOP-FABRICATED DOWNSPOUT HANGERS |
111 | FIGURE 1-35 SHOP-FABRICATED DOWNSPOUT HANGERS |
112 | SPLASH PAN |
113 | FIGURE 1-36 SPLASH PAN |
114 | FORMED ROOF SUMPS |
115 | FIGURE 1-37 FORMED ROOF SUMPS |
116 | ROOF DRAINS |
117 | FIGURE 1-38 ROOF DRAINS |
121 | CHAPTER 2 ROOF EDGING AND PERIMETERS ROOF EDGING AND PERIMETERS โ DESIGN DATA |
123 | FIGURE 2-1 FORMED GRAVEL-STOP”FASCIA โ DESIGN DATA |
124 | Table 2-1 Gravel-Stop and Cap Fascia Design |
125 | FIGURE 2-2 FORMED GRAVEL-STOP”FASCIA โ DESIGN DATA |
126 | FIGURE 2-3 ROOF-FASCIA-SOFFIT TRANSITIONS |
127 | FIGURE 2-4 FASCIA AND SOFFIT DESIGN DATA |
128 | FORMED GRAVEL-STOP”FASCIA โ JOINT SYSTEMS |
129 | FIGURE 2-5 FORMED GRAVEL-STOP”FASCIA โ JOINT SYSTEMS |
130 | CAP FASCIA”INSTALLATION |
131 | FIGURE 2-6 CAP FASCIA – INSTALLATION |
132 | FORMED GRAVEL-STOP”FASCIA โ SOFFIT INSTALLATION |
133 | FIGURE 2-7 FORMED GRAVEL-STOP”FASCIA โ SOFFIT INSTALLATION |
134 | FORMED GRAVEL-STOP RECESSED”INSTALLATION |
135 | FIGURE 2-8 FORMED GRAVEL-STOP RECESSED – INSTALLATION |
136 | HEAVY-GAGE FORMED GRAVEL”STOP”FASCIA INSTALLATION |
137 | FIGURE 2-9 HEAVY-GAGE FORMED GRAVEL-STOP”FASCIA โ INSTALLATION |
138 | HEAVY-GAGE GRAVEL-STOP”FASCIA โ JOINTS AND CORNERS |
139 | FIGURE 2-10 HEAVY-GAGE GRAVEL-STOP”FASCIAโJOINTS AND CORNERS |
140 | HEAVY-GAGE GRAVEL-STOP”FASCIA โ INSTALLATIONS |
141 | FIGURE 2-11 HEAVY-GAGE GRAVEL-STOP”FASCIA โ INSTALLATIONS |
142 | ROOF PAVER RETENTION |
143 | FIGURE 2-12 ROOF PAVER RETENTION |
144 | ROOF MEMBRANE PROTECTION |
145 | FIGURE 2-13 ROOF MEMBRANE PROTECTION |
146 | ROOF PAVER SYSTEMS ” OUTER EDGE |
147 | FIGURE 2-14 ROOF PAVER SYSTEMS ” OUTER EDGE |
148 | ROOF PAVER SYSTEMS ” EDGE RETENTION |
149 | FIGURE 2-15 ROOF PAVER SYSTEMS ” EDGE RETENTION |
150 | ROOF PAVER SYSTEMS ” SCUPPER DRAIN |
151 | FIGURE 2-16 ROOF PAVER SYSTEMS ” SCUPPER DRAIN |
155 | CHAPTER 3 COPINGS FORMED METAL COPINGS โ DESIGN DATA |
156 | FIGURE 3-1 FORMED METAL COPINGS โ DESIGN DATA |
157 | Table 3-1 Coping Design |
158 | SUPPLEMENTAL DESIGN DATA FOR TABLE 3″1 |
159 | LOCKS AND SEAMS DESIGN DATA |
160 | FIGURE 3-2 LOCKS AND SEAMS DESIGN DATA |
161 | FIGURE 3-3 LOCKS AND SEAMS DESIGN DATA |
162 | FORMED METAL COPINGS โ TYPICAL PROFILES |
163 | FIGURE 3-4 FORMED METAL COPINGS โ TYPICAL PROFILES |
164 | FORMED METAL COPINGS โ CURVED |
165 | FIGURE 3-5 FORMED METAL COPINGS โ CURVED |
166 | FORMED METAL COPINGS โ WITH FLASHING |
167 | FIGURE 3-6 FORMED METAL COPINGS โ WITH FLASHING |
168 | FORMED METAL COPINGS AND RELIEF JOINT |
169 | FIGURE 3-7 FORMED METAL COPINGS AND RELIEF JOINT |
170 | FORMED METAL COPINGS โ DUAL WALLS |
171 | FIGURE 3-8 FORMED METAL COPINGS โ DUAL WALLS |
172 | PARAPET WALL COVERING |
173 | FIGURE 3-9 PARAPET WALL COVERING |
177 | CHAPTER 4 FLASHING THROUGH-WALL FLASHING (GENERAL) |
178 | THROUGH-WALL FLASHING โ INSTALLATION FIGURE 4-1 THROUGH-WALL FLASHING โ INSTALLATION |
179 | THROUGH-WALL FLASHING โ CAVITY WALL FIGURE 4-2 THROUGH-WALL FLASHING โ CAVITY WALL |
180 | THROUGH-WALL FLASHING โ INSTALLATION”AT COPING |
181 | FIGURE 4-3 THROUGH-WALL FLASHING โ INSTALLATION-AT COPING |
182 | COUNTER FLASHING SYSTEMS (GENERAL) COUNTER FLASHING SYSTEMS โ INSTALLATION |
183 | FIGURE 4-4 COUNTER FLASHING SYSTEMS โ INSTALLATION |
184 | COUNTER FLASHING SYSTEMS โ INSTALLATION |
185 | FIGURE 4-5 COUNTER FLASHING SYSTEMS โ INSTALLATION |
186 | COUNTER FLASHING SYSTEMS โ INSTALLATION |
187 | FIGURE 4-6 COUNTER FLASHING SYSTEMS โ INSTALLATION |
188 | COUNTER FLASHING SYSTEMS โ INSTALLATION |
189 | FIGURE 4-7 COUNTER FLASHING SYSTEMS โ INSTALLATION |
190 | BASE AND COUNTER FLASHING SYSTEMS โ INSTALLATION |
191 | FIGURE 4-8 BASE AND COUNTER FLASHING SYSTEMS โ INSTALLATION |
192 | COUNTER FLASHING SYSTEMS โ INSTALLATION |
193 | FIGURE 4-9 COUNTER FLASHING SYSTEMS โ INSTALLATION |
194 | VALLEY FLASHING INSTALLATION |
195 | FIGURE 4-10 VALLEY FLASHING INSTALLATION |
196 | VALLEY FLASHING INSTALLATION |
197 | FIGURE 4-11 VALLEY FLASHING INSTALLATION |
198 | HIP AND RIDGE FLASHING |
199 | FIGURE 4-12 HIP AND RIDGE FLASHING |
200 | RIDGE FLASHING AT MANSARD ROOF |
201 | FIGURE 4-13 RIDGE FLASHING AT MANSARD ROOF |
202 | CHIMNEY FLASHING |
203 | FIGURE 4-14 CHIMNEY FLASHING |
204 | CHIMNEY FLASHING (STUCCO) |
205 | FIGURE 4-15 CHIMNEY FLASHING (STUCCO) |
206 | LEDGE FLASHING |
207 | FIGURE 4-16 LEDGE FLASHING |
208 | DORMER-HEAD”SILL FLASHING FOR FRAME CONSTRUCTION |
209 | FIGURE 4-17 DORMER-HEAD”SILL FLASHING FOR FRAME CONSTRUCTION |
210 | SHINGLE ROOF FLASHING |
211 | FIGURE 4-18 SHINGLE ROOF FLASHING |
212 | TERMITE SHIELDS |
213 | FIGURE 4-19 TERMITE SHIELDS |
217 | CHAPTER 5 BUILDING EXPANSION BUILDING EXPANSION JOINTS (GENERAL) |
218 | BUILDING EXPANSION JOINTS โ ROOF |
219 | FIGURE 5-1 BUILDING EXPANSION JOINTS โ ROOF |
220 | EXPANSION JOINT INTERSECTION |
221 | FIGURE 5-2 EXPANSION JOINT INTERSECTION |
222 | BUILDING EXPANSION JOINTS โ ROOF AT GRAVEL-STOP |
223 | FIGURE 5-3 BUILDING EXPANSION JOINTS โ ROOF AT GRAVEL-STOP |
224 | BUILDING EXPANSION JOINTS โ ROOF |
225 | FIGURE 5-4 BUILDING EXPANSION JOINTS โ ROOF |
226 | BUILDING EXPANSION JOINTS โ ROOF |
227 | FIGURE 5-5 BUILDING EXPANSION JOINTS โ ROOF |
228 | BUILDING EXPANSION JOINTS โ ROOF”TO”WALL |
229 | FIGURE 5-6 BUILDING EXPANSION JOINTS โ ROOF”TO”WALL |
230 | BUILDING EXPANSION JOINTS โ WALL |
231 | FIGURE 5-7 BUILDING EXPANSION JOINTS โ WALL |
232 | BUILDING EXPANSION JOINTS โ IN SLABS |
233 | FIGURE 5-8 BUILDING EXPANSION JOINTS โ IN SLABS |
237 | CHAPTER 6 METAL ROOF SYSTEMS SUMMARY OF DESIGN GUIDELINES FOR METAL WALL AND ROOF SYSTEMS |
240 | METAL SIDING AND ROOFING COMMENTARY MECHANICAL VERSUS HAND SEAMING AND METAL THICKNESS PORTABLE ROLL FORMERS PREPAINTED METALS COMMENTARY |
242 | ROOF SUPPORT SYSTEMS TRANSVERSE SEAMS |
243 | FIGURE 6-1 ROOF SUPPORT SYSTEMS |
244 | METAL ROOF DECK โ TYPICAL PROFILES |
245 | FIGURE 6-2 METAL ROOF DECK โ TYPICAL PROFILES |
246 | FLAT SEAM ROOFS |
247 | FIGURE 6-3 FLAT SEAM ROOFS |
248 | CURVED-FLAT SEAM DORMER ROOF |
249 | FIGURE 6-4 CURVED-FLAT SEAM DORMER ROOF |
250 | STANDING SEAM ROOFS Table 6-1 Gage and Pan Widths for Standing Seam Roofs |
251 | FIGURE 6-5 STANDING SEAM ROOFS |
252 | FIGURE 6-6 STANDING SEAM ROOFS |
253 | FIGURE 6-7 STANDING SEAM ROOFS |
254 | BATTEN SEAM ROOFS |
255 | FIGURE 6-8 BATTEN SEAM ROOFS |
256 | FIGURE 6-9 BATTEN SEAM ROOFS |
257 | FIGURE 6-10 BATTEN SEAM ROOFS |
258 | BERMUDA TYPE ROOFS Table 6-2 Recommended Gages and Pan Widths for Bermuda Roofs |
259 | FIGURE 6-11 BERMUDA TYPE ROOFS |
260 | FIGURE 6-12 BERMUDA TYPE ROOFS |
261 | FIGURE 6-13 BERMUDA TYPE ROOFS |
262 | ROOF TRANSITIONS |
263 | FIGURE 6-14 ROOF TRANSITIONS |
264 | METAL ROOF EAVES |
265 | FIGURE 6-15 METAL ROOF EAVES CONDITIONS |
266 | EAVES WITH ICE DAMS |
267 | FIGURE 6-16 EAVES WITH ICE DAMS |
268 | VENTED AND NON-VENTED RIDGE CAPS |
269 | FIGURE 6-17 VENTED AND NON-VENTED RIDGE CAPS |
270 | GABLE AND RAKE FLASHING |
271 | FIGURE 6-18 GABLE AND RAKE FLASHING |
272 | MANSARD ROOFS AND EQUIPMENT SCREENS |
273 | FIGURE 6-19 MANSARD ROOFS AND EQUIPMENT SCREENS |
274 | MANSARD ROOFS |
275 | FIGURE 6-20 MANSARD ROOFS |
276 | WINDOW (BAY) AND ORNAMENTAL ROOFS |
277 | FIGURE 6-21 WINDOW (BAY) AND ORNAMENTAL ROOFS |
278 | DOMES AND CONICAL ROOFS |
279 | FIGURE 6-22 DOMES AND CONICAL ROOFS |
280 | METAL ROOF PANEL EXPANSION AND CONTRACTION |
281 | FIGURE 6-23 METAL ROOF PANEL EXPANSION AND CONTRACTION |
284 | CHAPTER 7 METAL WALLS FIGURE 7-1 WALL SYSTEM FEATURES |
285 | FIGURE 7-2 WALL SYSTEM FEATURES |
286 | FIGURE 7-3 WALL SYSTEM FEATURES |
287 | FIGURE 7-4 METAL SIDING AND ROOFING โ TYPICAL PROFILES |
288 | HEAD, SOFFIT, AND SILL FLASHING |
289 | FIGURE 7-5 HEAD, SOFFIT, AND SILL FLASHING |
290 | WALL TO ROOF FLASHING |
291 | FIGURE 7-6 WALL TO ROOF FLASHING |
292 | METAL WALL PARAPET |
293 | FIGURE 7-7 METAL WALL PARAPET |
294 | WALL PANEL CORNERS |
295 | FIGURE 7-8 WALL PANEL CORNERS |
296 | WALL PANEL CORNERS |
297 | FIGURE 7-9 WALL PANEL CORNERS |
301 | CHAPTER 8 WALL AND ROOF PENETRATIONS ROOF PANEL PENETRATIONS โ GENERAL |
302 | ROOF PANEL PENETRATION |
303 | FIGURE 8-1 ROOF PANEL PENETRATION |
304 | ROOF PANEL PENETRATION |
305 | FIGURE 8-2 ROOF PANEL PENETRATION |
306 | ROOF PANEL PENETRATION |
307 | FIGURE 8-3 ROOF PANEL PENETRATION |
308 | WALL PENETRATION FLASHING |
309 | FIGURE 8-4 WALL PENETRATION FLASHING |
310 | WALL PENETRATION FLASHING |
311 | FIGURE 8-5 WALL PENETRATION FLASHING |
312 | WALL PENETRATION FLASHING |
313 | FIGURE 8-6 WALL PENETRATION FLASHING |
314 | WALL PENETRATION FLASHING |
315 | FIGURE 8-7 WALL PENETRATION FLASHING |
316 | ROOF PENETRATION FLASHING ” PIPES |
317 | FIGURE 8-8 ROOF PENETRATION FLASHING – PIPES |
318 | ROOF PENETRATION FLASHING โ PIPES |
319 | FIGURE 8-9 ROOF PENETRATION FLASHING โ PIPES |
320 | ROOF PENETRATION FLASHING โ STRUCTURAL STEEL |
321 | FIGURE 8-10 ROOF PENETRATION FLASHING โ STRUCTURAL STEEL |
322 | EQUIPMENT SUPPORT FLASHING Table 8-1 Rooftop Equipment Elevation |
323 | FIGURE 8-11 EQUIPMENT SUPPORT FLASHING |
324 | SLOPING ROOF PENETRATION FLASHING |
325 | FIGURE 8-12 SLOPING ROOF PENETRATION FLASHING |
328 | CHAPTER 9 LOUVERS, SCREENS AND SKYLIGHTS FORMED LOUVERS โ STATIONARY |
329 | FIGURE 9-1 FORMED LOUVERS โ STATIONARY |
330 | FORMED LOUVERS โ STATIONARY Table 9-1 Louver Blade and Frame Construction Details |
331 | FIGURE 9-2 FORMED LOUVERS โ STATIONARY |
332 | FORMED LOUVERS โ ADJUSTABLE |
333 | FIGURE 9-3 FORMED LOUVERS โ ADJUSTABLE |
334 | FORMED LOUVERS โ ADJUSTABLE |
335 | FIGURE 9-4 FORMED LOUVERS โ ADJUSTABLE |
336 | EXTRUDED LOUVERS |
337 | FIGURE 9-5 EXTRUDED LOUVERS |
338 | LOUVER MULLION COVERS |
339 | FIGURE 9-6 LOUVER MULLION COVERS |
340 | LOUVER SCREENS |
341 | FIGURE 9-7 LOUVER SCREENS |
342 | LOUVERED ENCLOSURES |
343 | FIGURE 9-8 LOUVERED ENCLOSURES |
344 | LOUVERED PENTHOUSE |
345 | FIGURE 9-9 LOUVERED PENTHOUSE |
346 | SUNSHADE โ LOUVERED |
347 | FIGURE 9-10 SUNSHADE โ LOUVERED |
348 | SUNSHADE CANOPY |
349 | FIGURE 9-11 SUNSHADE CANOPY |
350 | PLASTIC SKYLIGHTS |
351 | FIGURE 9-12 PLASTIC SKYLIGHTS |
352 | FIGURE 9-13 LOUVER FREE AREA CALCULATION |
354 | CHAPTER 10 INTERIOR ARCHITECTURAL SHEET METAL ELEMENTS COLUMN COVERS |
355 | FIGURE 10-1 COLUMN COVERS |
356 | CORNER GUARDS |
357 | FIGURE 10-2 CORNER GUARDS |
358 | INTERIOR WALL LINING |
359 | FIGURE 10-3 INTERIOR WALL LINING |
360 | PARTITION AND COLUMN CLOSURES AND MULLION COVERS |
361 | FIGURE 10-4 PARTITION AND COLUMN CLOSURES AND MULLION COVERS |
362 | PLANTER BOX LINERS |
363 | FIGURE 10-5 PLANTER BOX LINERS |
364 | DRAPERY POCKETS |
365 | FIGURE 10-6 DRAPERY POCKETS |
366 | LIGHTING TROUGHS |
367 | FIGURE 10-7 LIGHTING TROUGHS |
368 | HOODS โ ORNAMENTAL |
369 | FIGURE 10-8 HOODS โ ORNAMENTAL |
370 | LINEN AND TRASH CHUTES |
371 | FIGURE 10-9 LINEN AND TRASH CHUTES |
374 | CHAPTER 11 OTHER METAL ELEMENTS ROOF SCUTTLES |
375 | FIGURE 11-1 ROOF SCUTTLES |
376 | SMOKE HATCHES |
377 | FIGURE 11-2 SMOKE HATCHES |
378 | CURTAINS โ DRAFT OR FIRE |
379 | FIGURE 11-3 CURTAINS โ DRAFT OR FIRE |
380 | CORNERSTONE BOXES |
381 | FIGURE 11-4 CORNERSTONE BOXES |
382 | SNOW GUARDS |
383 | FIGURE 11-5 SNOW GUARDS |
384 | SNOW RETENTION SYSTEM COMMENTARY |
387 | CHAPTER 12 HISTORICAL RESTORATION HISTORY OF METALS IN ARCHITECTURE |
388 | ARCHITECTURAL SHEET METAL’S ROLE IN SUSTAINABILITY |
389 | SUMMARY OF HISTORIC RESTORATION OF ARCHITECTURAL SHEET METAL |
390 | HISTORIC PRESERVATION PRE-QUALIFICATION SPECIAL QUALIFICATION REQUIREMENTS |
392 | HISTORIC PRESERVATION CONTRACTOR PERSONNEL EXPERIENCE QUALIFICATION FORM |
393 | HISTORIC PRESERVATION QUALIFICATIONS FORM |
394 | HISTORIC METAL SHINGLE ROOFS RESTORATION AND REHABILITATION |
395 | CORNICE RESTORATION |
396 | CORNICE ASSEMBLY AT PARAPET |
397 | FIGURE 12-1 CORNICE ASSEMBLY AT PARAPET |
398 | CORNICE ASSEMBLY WITH GUTTER |
399 | FIGURE 12-2 CORNICE ASSEMBLY WITH GUTTER |
400 | FORMED SKYLIGHTS |
401 | FIGURE 12-3 FORMED SKYLIGHTS |
402 | FORMED SKYLIGHT-MUTIN |
403 | FIGURE 12-4 FORMED SKYLIGHT-MUTIN |
404 | SPIRES |
405 | FIGURE 12-5 SPIRES |
406 | CUPOLA/DOME/SPIRE (CDS) RESTORATION AND REHABILITATION ASSESSMENT |
407 | REHABILITATION/REPLACEMENT |
410 | PRESSED OR REPOUSSE REPLICATION AND REHABILITATION OF AESTHETIC METAL ELEMENTS |
411 | REHABILITAION OF AESTHETIC METAL ORNAMENTATION |
413 | FIGURE 12-6 CUPOLAS |
414 | FIGURE 12-7 COPPER DOME |
417 | APPENDIX A THICKNESS AND WEIGHT OF SHEET METALS A.1 THICKNESS AND WEIGHT OF SHEET METALS Table A-1 Thickness and Weight of Galvanized and Black Iron |
418 | Table A-2 Thickness and Weight of Copper Table A-3 Nominal Weight of Lead or Zinc-Coated Copper Sheet |
419 | Table A-4 Thickness and Weight of Stainless Steel |
420 | Table A-5 Thickness and Weight of Aluminum |
421 | Table A-6 Thickness and Weight of Zinc-Tin Alloy Table A-7 Thickness and Weight of Sheet Lead |
422 | Table A-8 Expansion of Building Materials |
423 | Table A-9 Metric Conversion Charts Inches into Millimeters and Feet to Meters |
427 | APPENDIX B METALS APPLICATION AND SPECIFICATIONS REFERENCES B.1 ALUMINUM |
428 | B.2 COPPER AND LEAD COATED COPPER |
429 | B.3 LEAD |
430 | B.4 GALVANIZED STEEL |
431 | B.5 STAINLESS STEEL |
434 | B.6 ZINC-TIN ALLOY |
435 | B.7 TERNE COATED STAINLESS |
436 | B.8 ZINC |
437 | B.9 ANODIZING B.10 PORCELAINS |
438 | B.11 SILICONIZED ACRYLIC AND POLYESTER PAINTS B.12 POLYURETHANES B.13 FLUOROPOLYMERS B.14 POWDERED METAL COATINGS |
441 | APPENDIX C GALVANIC CORROSION C.1 GALVANIC SCALE |
445 | APPENDIX D SHEET METAL ROOF TEST REPORT D.1 INTRODUCTION D.2 METAL ROOF DESCRIPTION |
447 | D.3 CONCLUSIONS |
448 | FIGURE D-1 SHEET METAL ROOF TEST REPORT |
449 | FIGURE D-2 SHEET METAL ROOF TEST REPORT |
450 | FIGURE D-3 SHEET METAL ROOF TEST REPORT |
451 | FIGURE D-4 SHEET METAL ROOF TEST REPORT |
455 | APPENDIX E CUSTOM FABRICATED METAL ROOFING SPECIFICATIONS E.1 DESCRIPTION E.2 QUALITY ASSURANCE |
457 | E.3 PERFORMANCE AND TESTING |
458 | E.4 SUBMITTALS |
459 | E.5 MATERIAL ” THICKNESS ” FINISHES |
462 | E.6 FABRICATION |
463 | E.7 IDENTIFICATION, DELIVERY, STORAGE AND HANDLING OF MATERIALS |
464 | E.8 INSTALLATION |
465 | E.9 ACCEPTANCE AND CLEAN UP |
469 | APPENDIX F MOISTURE AND MAINTENANCE OF BUILDING ENVELOPES F.1 MOISTURE TRANSFER METHODS F.2 CONTROLS AT THE DESIGN STAGE |
470 | F.3 UNDERLAYMENT COMMENTARY |
472 | F.4 GENERAL GUIDELINES FOR UNDERLAYMENT SELECTION |
473 | F.5 AIR LEAKAGE Table F-1 General Guidelines for Roof Underlayment Selection1 |
474 | F.6 DIRECTION OF LAPS F.7 DEHUMIDIFICATION F.8 INVESTIGATING MOISTURE PROBLEMS FROM A MAINTENANCE STANDPOINT |
475 | F.9 REPLACING AND REPAIRING F.10 OTHER THINGS TO LOOK FOR F.11 DESIGN DOCUMENT REFERENCES |
479 | APPENDIX G SCUPPER SIZING G.1 SCUPPER SIZING PROCEDURES: |
481 | Table G-1 Scupper Capacity In Gallons per Minute (GPM) Table G-1M Scupper Capacity in Liters per Second (l/s) |
482 | Table G-2 Downspout Leader Capacity FIGURE G”1 WEIR |
485 | APPENDIX H SMACNA REPRINTS 1929 STANDARD |
493 | APPENDIX I ADDITIONAL INFORMATIONAL PUBLICATIONS |
499 | APPENDIX J MECHANICAL FASTENERS J.1 MECHANICAL FASTENERS J.2 NAILS FIGURE J-1 NAIL SHANK TYPES |
500 | FIGURE J-2 NAIL POINTS FIGURE J-3 NAIL SHAPES |
501 | FIGURE J-4 NAIL SIZES |
502 | J.3 SCREWS FIGURE J-5 BUTRESS AND STANDARD THREAD SCREW SHANKS |
503 | FIGURE J-6 SCREW WITHDRAWAL RESISTANCE FIGURE J-7 ADDITIONAL SCREW INFORMATION |
504 | FIGURE J-8 SCREW POINTS FIGURE J-9 SELF-DRILLING AND SELF-TAPPING SCREW FUNCTION PHASES |
505 | FIGURE J-10 SCREW HEAD SHAPES |
506 | J.4 FASTENER EVALUATION |
509 | APPENDIX K SOLDERING K.1 SOLDERING |
510 | K.2 INSTALLER PREQUALIFICATION PROCEDURE FIGURE K-1 THE GREATEST USABLE HEAT IS AT THE LARGEST PART OF THE TINNED AREA |
515 | APPENDIX L ARCHITECTURAL FASCIA AND COPING WIND TESTS REPORT L.1 STRI WIND UPLIFT TESTING COPINGS AND FASCIA L.2 USING THIS TRB |
516 | L.3 USING THIS TRB L.4 MEMBRANE AND ATTACHMENT REQUIREMENTS FOR FASCIA Table 5 ” Minimum Metal Thickness for Flatness |
517 | ANS/SPRI ES1 2003 PERFORMANCE TEST REPORT |
523 | FIGURE L-1 FORMED METAL COPINGS โ DESIGN DATA |
524 | FIGURE L-2 FORMED GRAVEL-STOP-FASCIA – DESIGN DATA |
527 | APPENDIX M GENERAL GUIDE TO JOINT SEALANTS FOR ARCHITECTS |
539 | APPENDIX N FORMER COMMITTEE MEMBERS AND OTHER CONTRIBUTORS* |