{"id":110766,"date":"2024-10-18T16:00:10","date_gmt":"2024-10-18T16:00:10","guid":{"rendered":"https:\/\/pdfstandards.shop\/product\/uncategorized\/icc-significantchangestotheibc-2012\/"},"modified":"2024-10-24T21:58:48","modified_gmt":"2024-10-24T21:58:48","slug":"icc-significantchangestotheibc-2012","status":"publish","type":"product","link":"https:\/\/pdfstandards.shop\/product\/publishers\/icc\/icc-significantchangestotheibc-2012\/","title":{"rendered":"ICC SignificantChangestotheIBC 2012"},"content":{"rendered":"

Full access to the most critical updates to the International Building Code<\/p>\n

PDF Catalog<\/h4>\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n
PDF Pages<\/th>\nPDF Title<\/th>\n<\/tr>\n
1<\/td>\nCover <\/td>\n<\/tr>\n
4<\/td>\nContents <\/td>\n<\/tr>\n
14<\/td>\nPART 1 Administration: Chapters 1 and 2 <\/td>\n<\/tr>\n
15<\/td>\n102.4 Conflicting Provisions between Codes and Standards <\/td>\n<\/tr>\n
16<\/td>\n104.10.1 Code Modifications for Flood Hazard Areas <\/td>\n<\/tr>\n
18<\/td>\n105.2, #B2 Fences Exempt from Permits <\/td>\n<\/tr>\n
19<\/td>\n202 Definitions <\/td>\n<\/tr>\n
21<\/td>\nPART 2 Building Planning: Chapters 3 through 6 <\/td>\n<\/tr>\n
23<\/td>\n303.1.3 Assembly Rooms Associated with Group E Occupancies <\/td>\n<\/tr>\n
25<\/td>\n303.3 Occupancy Classification of Casino Gaming Floors <\/td>\n<\/tr>\n
27<\/td>\n303.3, 306.2 Occupancy Classification of Commercial Kitchens <\/td>\n<\/tr>\n
29<\/td>\nTable 307.1(1), Section 307.4 Facilities Generating Combustible Dusts <\/td>\n<\/tr>\n
30<\/td>\n308.2, 202 Definitions of Care Facilities <\/td>\n<\/tr>\n
32<\/td>\n308.4 Occupancy Classification for Medical Care Facilities <\/td>\n<\/tr>\n
34<\/td>\n310.6 Uses Classified as Group R-4 Occupancies <\/td>\n<\/tr>\n
36<\/td>\n402 Open Mall Buildings <\/td>\n<\/tr>\n
38<\/td>\n403.6.1 High-Rise Buildings\u2014Fire Service Access Elevators <\/td>\n<\/tr>\n
40<\/td>\n406.4 Public Parking Garages <\/td>\n<\/tr>\n
42<\/td>\n406.5.2.1 Open Parking Garages\u2014Openings below Grade <\/td>\n<\/tr>\n
44<\/td>\n406.5.5 Open Parking Garages\u2014Height and Area Increases <\/td>\n<\/tr>\n
46<\/td>\n410.6.3, 202 Technical Production Areas <\/td>\n<\/tr>\n
49<\/td>\n412.4.6.2 Aircraft Hangar Fire Areas <\/td>\n<\/tr>\n
51<\/td>\n414.5 Inside Storage, Dispensing, and Use of Hazardous Materials <\/td>\n<\/tr>\n
52<\/td>\n419, 202 Live\/Work Units <\/td>\n<\/tr>\n
55<\/td>\n422 Ambulatory Care Facilities <\/td>\n<\/tr>\n
57<\/td>\n424 Children\u2019s Play Structures <\/td>\n<\/tr>\n
60<\/td>\n501.2 Address Identification <\/td>\n<\/tr>\n
61<\/td>\n505.2.2 Mezzanine Means of Egress <\/td>\n<\/tr>\n
63<\/td>\n506.2.1 Allowable Area Frontage Increase <\/td>\n<\/tr>\n
66<\/td>\n507.1 Unlimited Area Buildings\u2014Accessory Occupancies <\/td>\n<\/tr>\n
68<\/td>\n507.1 Unlimited Area Buildings\u2014Open Space <\/td>\n<\/tr>\n
70<\/td>\n507.8 Unlimited Area Buildings\u2014Group H Occupancies <\/td>\n<\/tr>\n
73<\/td>\n509 Incidental Uses\u2014General Provisions <\/td>\n<\/tr>\n
75<\/td>\n509 Incidental Uses\u2014Separation and Protection <\/td>\n<\/tr>\n
77<\/td>\nTable 509 Incidental Uses\u2014Rooms or Areas <\/td>\n<\/tr>\n
79<\/td>\nTable 602, Note h: Fire Ratings of Exterior Walls <\/td>\n<\/tr>\n
81<\/td>\nPART 3 Fire Protection: Chapters 7 through 9 <\/td>\n<\/tr>\n
83<\/td>\n701.2 Multiple-Use Fire Assemblies <\/td>\n<\/tr>\n
85<\/td>\n703.4 Establishing Fire Resistance Ratings <\/td>\n<\/tr>\n
86<\/td>\n703.7 Identification of Fire and Smoke Separation Walls <\/td>\n<\/tr>\n
88<\/td>\n704.11 Fire Protection of Bottom Flanges <\/td>\n<\/tr>\n
89<\/td>\n705.2 Extent of Projections beyond Exterior Walls <\/td>\n<\/tr>\n
91<\/td>\n705.2.3 Protection of Combustible Projections <\/td>\n<\/tr>\n
93<\/td>\n705.3 Projections from Buildings on the Same Lot <\/td>\n<\/tr>\n
95<\/td>\n706.2 Double Fire Walls <\/td>\n<\/tr>\n
97<\/td>\n706.6, 706.6.2 Fire Wall Height at Sloped Roofs <\/td>\n<\/tr>\n
99<\/td>\n707.8, 707.9 Intersections of Fire Barriers at Roof Assemblies <\/td>\n<\/tr>\n
101<\/td>\n709.4 Continuity of Smoke Barriers <\/td>\n<\/tr>\n
102<\/td>\n712 Vertical Openings <\/td>\n<\/tr>\n
104<\/td>\n713.13 Refuse and Laundry Chutes in Group I-2 Occupancies <\/td>\n<\/tr>\n
106<\/td>\n713.13.4 Fire Protection of Termination Rooms <\/td>\n<\/tr>\n
108<\/td>\n713.14.1 High-Rise Buildings\u2014Elevator Lobbies <\/td>\n<\/tr>\n
111<\/td>\n714.4.1.1.2 Floor Penetrations of Horizontal Assemblies <\/td>\n<\/tr>\n
113<\/td>\n714.4.1.2 Interruption of Horizontal Assemblies <\/td>\n<\/tr>\n
115<\/td>\n714.5, 715.6, 202 L Ratings <\/td>\n<\/tr>\n
117<\/td>\n715.4 Exterior Curtain Wall\/Floor Intersection <\/td>\n<\/tr>\n
119<\/td>\n716.3, 202 Marking of Fire-Rated Glazing Assemblies <\/td>\n<\/tr>\n
121<\/td>\nTable 716.5 Opening Protection Ratings and Markings <\/td>\n<\/tr>\n
124<\/td>\n716.5.5.1 Glazing in Exit Enclosure and Exit Passageway Doors <\/td>\n<\/tr>\n
126<\/td>\nTable 716.6 Fire-Protection-Rated Glazing <\/td>\n<\/tr>\n
128<\/td>\n716.6.4 Wired Glass in Fire Window Assemblies <\/td>\n<\/tr>\n
130<\/td>\n717.5.4 Fire Damper Exemption for Fire Partitions <\/td>\n<\/tr>\n
132<\/td>\n718.2.6 Fireblocking within Exterior Wall Coverings <\/td>\n<\/tr>\n
134<\/td>\n803.12 High-Density Polyethylene (HDPE) and Polypropylene (PP) <\/td>\n<\/tr>\n
135<\/td>\n804.4 Interior Floor Finish Requirements <\/td>\n<\/tr>\n
137<\/td>\n901.8 Pump and Riser Room Size <\/td>\n<\/tr>\n
138<\/td>\n903.2.2 Sprinklers in Ambulatory Care Facilities <\/td>\n<\/tr>\n
140<\/td>\n903.2.4, 903.2.7, 903.2.9 Furniture Storage and Display in Group F-1, M, and S-1 Occupancies <\/td>\n<\/tr>\n
142<\/td>\n903.2.11.1.3 Sprinkler Protection for Basements <\/td>\n<\/tr>\n
144<\/td>\n903.2.11.2 Sprinkler Protection of Rubbish and Linen Chutes <\/td>\n<\/tr>\n
147<\/td>\n903.3.5.2 Secondary Water Supply <\/td>\n<\/tr>\n
148<\/td>\n904.3.2 Actuation of Multiple Fire-Extinguishing Systems <\/td>\n<\/tr>\n
150<\/td>\n905.4 Location of Class I Standpipe Hose Connections <\/td>\n<\/tr>\n
152<\/td>\n906.1 Portable Fire Extinguishers in Group R-2 Occupancies <\/td>\n<\/tr>\n
153<\/td>\n907.2.1 Fire Alarms Systems in Group A Occupancies <\/td>\n<\/tr>\n
155<\/td>\n907.2.1.2 Emergency Voice\/Alarm Communication Captions <\/td>\n<\/tr>\n
157<\/td>\n907.2.3 Group E Fire Alarm Systems <\/td>\n<\/tr>\n
159<\/td>\n907.2.9.3 Smoke Detection in Group R-2 College Buildings <\/td>\n<\/tr>\n
162<\/td>\n907.2.11.3 Wireless Interconnection of Smoke Alarms <\/td>\n<\/tr>\n
164<\/td>\n908.7 Carbon Monoxide Alarms <\/td>\n<\/tr>\n
166<\/td>\nPART 4 Means of Egress: Chapter 10 <\/td>\n<\/tr>\n
168<\/td>\n1001.4 Fire Safety and Evacuation Plans <\/td>\n<\/tr>\n
170<\/td>\n1004.1.2, Table 1004.1.2 Design Occupant Load\u2014Areas without Fixed Seating <\/td>\n<\/tr>\n
172<\/td>\n1005 Means of Egress Capacity Determination <\/td>\n<\/tr>\n
176<\/td>\n1007 Accessible Means of Egress <\/td>\n<\/tr>\n
180<\/td>\n1008.1.2 Door Swing <\/td>\n<\/tr>\n
181<\/td>\n1008.1.9.9 Electromagnetically Locked Egress Doors <\/td>\n<\/tr>\n
183<\/td>\n1009, 1010, 202 Interior Stairways and Ramps <\/td>\n<\/tr>\n
187<\/td>\n1009.1 Application of Stairway Provisions <\/td>\n<\/tr>\n
188<\/td>\n1011.2 Floor-Level Exit Signs in Group R-1 <\/td>\n<\/tr>\n
189<\/td>\n1012.2 Handrail Height <\/td>\n<\/tr>\n
191<\/td>\n1012.3.1, 1012.8 Handrail Graspability and Projections <\/td>\n<\/tr>\n
193<\/td>\n1013.1, 1013.8 Guards at Operable Windows <\/td>\n<\/tr>\n
196<\/td>\n1013.3 Guard Height <\/td>\n<\/tr>\n
198<\/td>\n1021.2 Exits from Stories <\/td>\n<\/tr>\n
200<\/td>\n1021.2.1 Exits from Mixed Occupancy Buildings <\/td>\n<\/tr>\n
201<\/td>\n1021.2.3, Table 1021.2(1) Exits from Dwelling Units <\/td>\n<\/tr>\n
205<\/td>\n1022.5 Enclosure Penetrations of Interior Exit Stairways <\/td>\n<\/tr>\n
207<\/td>\n1028.1.1.1 Separation of Spaces under Grandstands and Bleachers <\/td>\n<\/tr>\n
208<\/td>\nPART 5 Accessibility: Chapter 11 <\/td>\n<\/tr>\n
209<\/td>\n1104.3.1 Employee Work Areas <\/td>\n<\/tr>\n
211<\/td>\n1107.6.1 Accessible Units in R-1 Occupancies <\/td>\n<\/tr>\n
213<\/td>\n1108.2.7.3 Captioning of Public Address Announcements <\/td>\n<\/tr>\n
215<\/td>\n1109.2, 1109.5 Accessible Children\u2019s Facilities <\/td>\n<\/tr>\n
218<\/td>\n1109.6 Accessible Saunas and Steam Rooms <\/td>\n<\/tr>\n
219<\/td>\n1110.4 Variable Message Signs <\/td>\n<\/tr>\n
222<\/td>\nPART 6 Building Envelope, Structural Systems, and Construction Materials: Chapters 12 through 26 <\/td>\n<\/tr>\n
225<\/td>\n1203.1 Mechanical Ventilation Required <\/td>\n<\/tr>\n
227<\/td>\n1203.2 Ventilation of Attic Spaces <\/td>\n<\/tr>\n
229<\/td>\n1208.3 Minimum Kitchen Floor Area <\/td>\n<\/tr>\n
230<\/td>\n1210 Toilet and Bathroom Requirements <\/td>\n<\/tr>\n
233<\/td>\n1403.5 Flame Propagation at Exterior Walls <\/td>\n<\/tr>\n
235<\/td>\n1404.12, 1405.18, 202 Polypropylene Siding <\/td>\n<\/tr>\n
237<\/td>\n1405.6 Anchored Masonry Veneer <\/td>\n<\/tr>\n
238<\/td>\n1503.4 Roof Drainage Systems <\/td>\n<\/tr>\n
240<\/td>\n1507.2.8.1 Roof Covering Underlayment in High Wind Areas <\/td>\n<\/tr>\n
242<\/td>\n1507.16 Roof Gardens and Landscaped Roofs <\/td>\n<\/tr>\n
244<\/td>\n1507.17, 3111, 202 Photovoltaic Systems <\/td>\n<\/tr>\n
246<\/td>\n1509, 202 Rooftop Structures <\/td>\n<\/tr>\n
253<\/td>\n1510.3 Roof Covering Replacement <\/td>\n<\/tr>\n
255<\/td>\nTable 1604.3 Deflection Limits <\/td>\n<\/tr>\n
256<\/td>\n1604.5, 202 Risk Categories <\/td>\n<\/tr>\n
259<\/td>\n1605.2 Load Combinations Using Strength Design of Load and Resistance Factor Design <\/td>\n<\/tr>\n
261<\/td>\n1605.3 Load Combinations Using Allowable Stress Design <\/td>\n<\/tr>\n
264<\/td>\nTable 1607.1 Minimum Live Loads <\/td>\n<\/tr>\n
268<\/td>\n1607.6, 202 Helipads <\/td>\n<\/tr>\n
270<\/td>\n1607.7 Heavy Vehicle Loads <\/td>\n<\/tr>\n
272<\/td>\n1608.3, 1611.2, 202 Ponding Instability <\/td>\n<\/tr>\n
273<\/td>\n1609, 202 Determination of Wind Loads <\/td>\n<\/tr>\n
283<\/td>\n1613.3.1, 202 Mapped Acceleration Parameters <\/td>\n<\/tr>\n
289<\/td>\n1613.4 Alternatives to ASCE 7 <\/td>\n<\/tr>\n
293<\/td>\n1614, 202 Atmospheric Ice Loads <\/td>\n<\/tr>\n
294<\/td>\n1704.3 Statement of Special Inspections <\/td>\n<\/tr>\n
298<\/td>\n1705.2 Special Inspection of Steel Construction <\/td>\n<\/tr>\n
302<\/td>\nTable 1705.3 Required Verification and Inspection of Concrete Construction <\/td>\n<\/tr>\n
304<\/td>\n1705.4 Special Inspection of Masonry Construction <\/td>\n<\/tr>\n
306<\/td>\n1705.16 Special Inspection of Fire-Resistant Penetration and Joint Systems <\/td>\n<\/tr>\n
307<\/td>\n1803.5.12 Geotechnical Reports for Foundation Walls and Retaining Walls <\/td>\n<\/tr>\n
308<\/td>\n1810.3.3.1.6 Uplift Capacity of Grouped Deep Foundation Elements <\/td>\n<\/tr>\n
309<\/td>\nChapter 19 Concrete Construction <\/td>\n<\/tr>\n
313<\/td>\n1905.1.3 Seismic Detailing of Wall Piers <\/td>\n<\/tr>\n
315<\/td>\n1905.1.8 Plain Concrete Footings in Dwelling Construction <\/td>\n<\/tr>\n
317<\/td>\n1905.1.9 Shear Wall to Concrete Foundation Connection <\/td>\n<\/tr>\n
321<\/td>\n2101.2 Design Methods for Masonry Structures <\/td>\n<\/tr>\n
322<\/td>\n2206 Composite Structural Steel and Concrete Structures <\/td>\n<\/tr>\n
324<\/td>\n2210.2 Seismic Requirements for Cold-Formed Steel Structures <\/td>\n<\/tr>\n
326<\/td>\n2305 General Design Requirements for Lateral-Force-Resisting Systems <\/td>\n<\/tr>\n
328<\/td>\n2306 Allowable Stress Design <\/td>\n<\/tr>\n
332<\/td>\n2307 Load and Resistance Factor Design <\/td>\n<\/tr>\n
334<\/td>\n2308.12 Braced Wall Line Sheathing <\/td>\n<\/tr>\n
337<\/td>\n2406.1, 2406.4 Safety Glazing\u2014Hazardous Locations <\/td>\n<\/tr>\n
343<\/td>\n2406.2 Safety Glazing\u2014Impact Test <\/td>\n<\/tr>\n
345<\/td>\n2510.6 Water-Resistive Barriers for Stucco Applications <\/td>\n<\/tr>\n
347<\/td>\n2603.4.1.14 Foam Plastic Insulation Installed in Floor Assemblies <\/td>\n<\/tr>\n
349<\/td>\n2603.7, 2603.8 Interior Finish in Plenums <\/td>\n<\/tr>\n
351<\/td>\n2603.10, 2603.10.1 Special Approval of Foam Plastics <\/td>\n<\/tr>\n
353<\/td>\n2610.3 Slope Requirements of a Dome Skylight <\/td>\n<\/tr>\n
355<\/td>\n2612, 202 Fiber-Reinforced Polymer <\/td>\n<\/tr>\n
359<\/td>\nPART 7 Building Services, Special Devices, and Special Conditions: Chapters 27 through 34 <\/td>\n<\/tr>\n
360<\/td>\n2902.2 Single-User Toilet Facilities <\/td>\n<\/tr>\n
362<\/td>\n2902.3 Toilet Facilities in Parking Garages <\/td>\n<\/tr>\n
363<\/td>\n2902.3.5 Locking of Toilet Room Doors <\/td>\n<\/tr>\n
364<\/td>\n2902.5 Required Drinking Fountains <\/td>\n<\/tr>\n
365<\/td>\n3007 Fire Service Access Elevators <\/td>\n<\/tr>\n
370<\/td>\n3008 Occupant Evacuation Elevators <\/td>\n<\/tr>\n
374<\/td>\n3108 Telecommunication and Broadcast Towers <\/td>\n<\/tr>\n
375<\/td>\n3302.3, 3303.7, 3313 Fire Safety during Construction <\/td>\n<\/tr>\n
377<\/td>\n3401.3 Compliance for Existing Buildings <\/td>\n<\/tr>\n
379<\/td>\n3411 Type B Units in Existing Buildings <\/td>\n<\/tr>\n
384<\/td>\nAppendix L: Earthquake-Recording Instruments <\/td>\n<\/tr>\n
386<\/td>\nAppendix M: Tsunami-Generated Flood Hazards <\/td>\n<\/tr>\n
388<\/td>\nIndex
A
B
C <\/td>\n<\/tr>\n
389<\/td>\nD
E
F <\/td>\n<\/tr>\n
390<\/td>\nG <\/td>\n<\/tr>\n
391<\/td>\nH
I
J
K
L
M <\/td>\n<\/tr>\n
392<\/td>\nN
O
P
R
S <\/td>\n<\/tr>\n
393<\/td>\nT
U
V
W <\/td>\n<\/tr>\n<\/table>\n","protected":false},"excerpt":{"rendered":"

Significant Changes to the International Building Code, 2012 Edition<\/b><\/p>\n\n\n\n\n
Published By<\/td>\nPublication Date<\/td>\nNumber of Pages<\/td>\n<\/tr>\n
ICC<\/b><\/a><\/td>\n2012<\/td>\n399<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n","protected":false},"featured_media":110767,"template":"","meta":{"rank_math_lock_modified_date":false,"ep_exclude_from_search":false},"product_cat":[2670],"product_tag":[],"class_list":{"0":"post-110766","1":"product","2":"type-product","3":"status-publish","4":"has-post-thumbnail","6":"product_cat-icc","8":"first","9":"instock","10":"sold-individually","11":"shipping-taxable","12":"purchasable","13":"product-type-simple"},"_links":{"self":[{"href":"https:\/\/pdfstandards.shop\/wp-json\/wp\/v2\/product\/110766","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/pdfstandards.shop\/wp-json\/wp\/v2\/product"}],"about":[{"href":"https:\/\/pdfstandards.shop\/wp-json\/wp\/v2\/types\/product"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/pdfstandards.shop\/wp-json\/wp\/v2\/media\/110767"}],"wp:attachment":[{"href":"https:\/\/pdfstandards.shop\/wp-json\/wp\/v2\/media?parent=110766"}],"wp:term":[{"taxonomy":"product_cat","embeddable":true,"href":"https:\/\/pdfstandards.shop\/wp-json\/wp\/v2\/product_cat?post=110766"},{"taxonomy":"product_tag","embeddable":true,"href":"https:\/\/pdfstandards.shop\/wp-json\/wp\/v2\/product_tag?post=110766"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}