{"id":194831,"date":"2024-10-19T12:21:46","date_gmt":"2024-10-19T12:21:46","guid":{"rendered":"https:\/\/pdfstandards.shop\/product\/uncategorized\/ieee-ansi-n42-35-2016\/"},"modified":"2024-10-25T04:52:48","modified_gmt":"2024-10-25T04:52:48","slug":"ieee-ansi-n42-35-2016","status":"publish","type":"product","link":"https:\/\/pdfstandards.shop\/product\/publishers\/ieee\/ieee-ansi-n42-35-2016\/","title":{"rendered":"IEEE ANSI N42.35 2016"},"content":{"rendered":"

Revision Standard – Active. Minimum performance specifications and testing methods for the evaluation of radiation portal monitors, also known as RPMs, are contained in this standard. These monitors are large-size permanently mounted-type instruments. These instruments are primarily designed for the detection of radioactive materials emitting gamma rays and neutrons. The specifications for general, radiological, environmental, electromagnetic and mechanical performance are given and the corresponding testing methods are described. The documentation to be provided by the manufacturer is listed as part of the requirements. A number of informative annexes that provide useful information and guidance in implementing this standard are also contained in this standard. (The PDF of this standard is available at no cost compliments of the Department of Homeland Security Domestic Nuclear Detection Office. https:\/\/ieeexplore.ieee.org\/browse\/standards\/get-program\/page)<\/p>\n

PDF Catalog<\/h4>\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n
PDF Pages<\/th>\nPDF Title<\/th>\n<\/tr>\n
1<\/td>\nANSI N42.35-2016 Front cover
\n <\/td>\n<\/tr>\n
2<\/td>\nTitle page
\n <\/td>\n<\/tr>\n
4<\/td>\nAmerican National Standard <\/td>\n<\/tr>\n
5<\/td>\nImportant Notices and Disclaimers Concerning IEEE Standards Documents <\/td>\n<\/tr>\n
8<\/td>\nParticipants <\/td>\n<\/tr>\n
10<\/td>\nIntroduction <\/td>\n<\/tr>\n
11<\/td>\nContents <\/td>\n<\/tr>\n
13<\/td>\nIMPORTANT NOTICE
1. Overview
1.1 Scope
1.2 Purpose <\/td>\n<\/tr>\n
14<\/td>\n2. References
3. Definitions, acronyms, and abbreviations
3.1 Definitions <\/td>\n<\/tr>\n
17<\/td>\n3.2 Acronyms and abbreviations <\/td>\n<\/tr>\n
18<\/td>\n4. General considerations
4.1 Evaluation of radiation portal monitors
4.2 Meeting performance specifications
4.3 Units and uncertainties
4.4 Special word usage <\/td>\n<\/tr>\n
19<\/td>\n4.5 Standard test conditions
4.6 Statistical fluctuations <\/td>\n<\/tr>\n
20<\/td>\n4.7 Background radiation during testing
4.8 RPM setup
4.9 Evaluation distances and speeds
4.10 Radiation sources <\/td>\n<\/tr>\n
22<\/td>\n4.11 Dynamic test method
4.12 Functionality tests\u2014Test acceptance range <\/td>\n<\/tr>\n
24<\/td>\n5. Design requirements
5.1 General characteristics <\/td>\n<\/tr>\n
26<\/td>\n5.2 Physical configuration
5.3 Type of radiation detector <\/td>\n<\/tr>\n
27<\/td>\n5.4 Size and weight
5.5 Detection system construction
5.6 Power requirement and consumption
5.7 Alternative power supply <\/td>\n<\/tr>\n
28<\/td>\n5.8 Operating parameters
5.9 Data storage
5.10 Data format <\/td>\n<\/tr>\n
29<\/td>\n5.11 Communications protocol <\/td>\n<\/tr>\n
30<\/td>\n5.12 Indication features
5.13 Occupancy and speed sensors for RPMs <\/td>\n<\/tr>\n
31<\/td>\n5.14 Markings
5.15 Protection of switches <\/td>\n<\/tr>\n
32<\/td>\n5.16 Effective range of measurement
5.17 User Interface <\/td>\n<\/tr>\n
34<\/td>\n6. Radiological tests
6.1 False alarm test <\/td>\n<\/tr>\n
35<\/td>\n6.2 Detector response to gamma radiation
6.3 Energy analysis capabilities (for RPMs that have this capability) <\/td>\n<\/tr>\n
36<\/td>\n6.4 Detector response to neutron radiation
6.5 Over-range test for gamma-rays <\/td>\n<\/tr>\n
37<\/td>\n6.6 Neutron indication in the presence of photons <\/td>\n<\/tr>\n
38<\/td>\n6.7 Background effects from a slowly approaching source <\/td>\n<\/tr>\n
39<\/td>\n7. Environmental performance requirements
7.1 Ambient temperature <\/td>\n<\/tr>\n
40<\/td>\n7.2 Relative humidity <\/td>\n<\/tr>\n
41<\/td>\n7.3 Moisture and dust protection <\/td>\n<\/tr>\n
43<\/td>\n8. Electrical and electromagnetic performance requirements
8.1 Power supply <\/td>\n<\/tr>\n
44<\/td>\n8.2 Radiated emissions <\/td>\n<\/tr>\n
45<\/td>\n8.3 Radiated Immunity <\/td>\n<\/tr>\n
46<\/td>\n8.4 Electrostatic discharge
8.5 Conducted disturbances induced by bursts and radio frequencies <\/td>\n<\/tr>\n
47<\/td>\n8.6 Surges and oscillatory waves <\/td>\n<\/tr>\n
48<\/td>\n9. Mechanical performance requirements
9.1 Microphonics\/Impact <\/td>\n<\/tr>\n
49<\/td>\n9.2 Vibration
10. Documentation
10.1 Certificate
10.2 Operation and maintenance manual <\/td>\n<\/tr>\n
51<\/td>\nAnnex A (informative) Bibliography <\/td>\n<\/tr>\n
55<\/td>\nAnnex B (informative) Diagram of mounting dimensions for radiation portal monitors <\/td>\n<\/tr>\n
56<\/td>\nAnnex C (informative) Source array calculation for neutrons in the presence of photons test <\/td>\n<\/tr>\n
59<\/td>\nAnnex D (informative) Energy analysis for material classification <\/td>\n<\/tr>\n
60<\/td>\nAnnex E (informative) Alarm indication <\/td>\n<\/tr>\n
61<\/td>\nAnnex F (informative) General information regarding the adoption or changes in key requirements <\/td>\n<\/tr>\n
69<\/td>\nAnnex G (informative) Extended test of PVT stability through accelerated aging <\/td>\n<\/tr>\n<\/table>\n","protected":false},"excerpt":{"rendered":"

American National Standard for Evaluation and Performance of Radiation Detection Portal Monitors for Use in Homeland Security<\/b><\/p>\n\n\n\n\n
Published By<\/td>\nPublication Date<\/td>\nNumber of Pages<\/td>\n<\/tr>\n
IEEE<\/b><\/a><\/td>\n2016<\/td>\n70<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n","protected":false},"featured_media":194838,"template":"","meta":{"rank_math_lock_modified_date":false,"ep_exclude_from_search":false},"product_cat":[2644],"product_tag":[],"class_list":{"0":"post-194831","1":"product","2":"type-product","3":"status-publish","4":"has-post-thumbnail","6":"product_cat-ieee","8":"first","9":"instock","10":"sold-individually","11":"shipping-taxable","12":"purchasable","13":"product-type-simple"},"_links":{"self":[{"href":"https:\/\/pdfstandards.shop\/wp-json\/wp\/v2\/product\/194831","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/pdfstandards.shop\/wp-json\/wp\/v2\/product"}],"about":[{"href":"https:\/\/pdfstandards.shop\/wp-json\/wp\/v2\/types\/product"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/pdfstandards.shop\/wp-json\/wp\/v2\/media\/194838"}],"wp:attachment":[{"href":"https:\/\/pdfstandards.shop\/wp-json\/wp\/v2\/media?parent=194831"}],"wp:term":[{"taxonomy":"product_cat","embeddable":true,"href":"https:\/\/pdfstandards.shop\/wp-json\/wp\/v2\/product_cat?post=194831"},{"taxonomy":"product_tag","embeddable":true,"href":"https:\/\/pdfstandards.shop\/wp-json\/wp\/v2\/product_tag?post=194831"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}