{"id":202539,"date":"2024-10-19T12:57:17","date_gmt":"2024-10-19T12:57:17","guid":{"rendered":"https:\/\/pdfstandards.shop\/product\/uncategorized\/icc-significantchangestothempfc-2018\/"},"modified":"2024-10-25T05:35:09","modified_gmt":"2024-10-25T05:35:09","slug":"icc-significantchangestothempfc-2018","status":"publish","type":"product","link":"https:\/\/pdfstandards.shop\/product\/publishers\/icc\/icc-significantchangestothempfc-2018\/","title":{"rendered":"ICC SignificantChangestotheMPFC 2018"},"content":{"rendered":"

Gain full access to the most critical updates to the International Plumbing Code\u00ae, International Mechanical Code\u00ae and International Fuel Gas Code\u00ae, the real world application of those changes, and why they originated\u2014all in a single easy-to-use resource. Significant Changes to the International Plumbing Code\u00ae, International Mechanical Code\u00ae, and International Fuel Gas Code\u00ae 2018 Edition provides a comprehensive analysis of the significant changes in the new editions of these codes, offering key insights into the implications of those changes. Each change analysis features the affected code sections and identifies the change as newly added text, a modification or clarification of the existing language or deleted text. Accompanying each change is a photograph, detailed illustration or comprehensive example to assist and enhance reader understanding. The book\u2019s attention to detail, its logical organization, and its thorough yet concise coverage all make it an ideal tool for transitioning from the 2015 to the 2018 editions of the International Plumbing Code\u00ae, International Mechanical Code\u00ae, and International Fuel Gas Code\u00ae.<\/p>\n

PDF Catalog<\/h4>\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n
PDF Pages<\/th>\nPDF Title<\/th>\n<\/tr>\n
1<\/td>\n2018 SIGNIFICANT CHANGES TO THE INTERNATIONAL PLUMBING CODE\u00ae, INTERNATIONAL MECHANICAL CODE\u00ae, INTERNATIONAL FUEL GAS CODE\u00ae <\/td>\n<\/tr>\n
2<\/td>\n2018 SIGNIFICANT CHANGES TO THE INTERNATIONAL PLUMBING CODE\u00ae, INTERNATIONAL MECHANICAL CODE\u00ae, INTERNATIONAL FUEL GAS CODE\u00ae TITLE PAGE <\/td>\n<\/tr>\n
3<\/td>\nCOPYRIGHT <\/td>\n<\/tr>\n
4<\/td>\nCONTENTS <\/td>\n<\/tr>\n
8<\/td>\nPREFACE <\/td>\n<\/tr>\n
12<\/td>\nPART 1: INTERNATIONAL PLUMBING CODE – CHAPTERS 1 THROUGH 15 <\/td>\n<\/tr>\n
15<\/td>\n202 DEFINITION OF ACCESSIBLE
IMAGE: ACCESSIBLE DRINKING FOUNTAINS <\/td>\n<\/tr>\n
16<\/td>\nIMAGE: ACCESS TO WHIRLPOOL TUB PUMP <\/td>\n<\/tr>\n
17<\/td>\n202 DEFINITION OF FULL OPEN VALVE
IMAGE: PLUG VALVE WITH RECTANGULAR PORT IN CLOSURE MEMBER <\/td>\n<\/tr>\n
18<\/td>\n202 DEFINITION OF PRESS-CONNECT JOINT
IMAGE: PRESS-CONNECT COPPER FITTING <\/td>\n<\/tr>\n
19<\/td>\n202 DEFINITION OF PUBLIC SWIMMING POOL
IMAGE: PUBLIC SWIMMING POOL <\/td>\n<\/tr>\n
20<\/td>\nIMAGE: PUBLIC SWIMMING POOL SERVING AN APARTMENT COMPLEX <\/td>\n<\/tr>\n
21<\/td>\n202 DEFINITION OF SWIMMING POOL
IMAGE: PUBLIC SWIMMING POOL <\/td>\n<\/tr>\n
22<\/td>\nIMAGE: RESIDENTIAL SWIMMING POOL (ON GROUND)
IMAGE: RESIDENTIAL SWIMMING POOL ( IN-GROUND) <\/td>\n<\/tr>\n
23<\/td>\n303.5 THIRD-PARTY CERTIFICATION FOR CAST-IRON PIPE
IMAGE: CAST-IRON PIPING <\/td>\n<\/tr>\n
24<\/td>\n305.1 CORROSION PROTECTION FOR METALLIC PIPING
IMAGE: METALLIC PIPING IN PLASTIC SHEATHING <\/td>\n<\/tr>\n
25<\/td>\n305.6 PROTECTION AGAINST PHYSICAL DAMAGE
FIGURE: MINIMUM ALLOWABLE DISTANCE FROM FACE OF MEMBER TO PIPE <\/td>\n<\/tr>\n
26<\/td>\n308.6 SWAY BRACING FOR DRAINAGE PIPING
FIGURE: ONE METHOD OF ANTI-SWAY BRACING <\/td>\n<\/tr>\n
27<\/td>\n308.10 THERMAL EXPANSION TANK SUPPORT
IMAGE: UNSUPPORTED THERMAL EXPANSION TANK <\/td>\n<\/tr>\n
28<\/td>\nIMAGE: ONE METHOD OF INDEPENDENT TANK SUPPORT <\/td>\n<\/tr>\n
29<\/td>\nTABLE 403.1 GAMING AREA PLUMBING FIXTURES
IMAGE: GAMING AREA <\/td>\n<\/tr>\n
30<\/td>\nTABLE 403.1 MINIMUM NUMBER OF REQUIRED PLUMBING FIXTURES <\/td>\n<\/tr>\n
31<\/td>\nTABLE 403.1 ROW SELECTION BASED ON DESCRIPTION OF USE COLUMN
IMAGE: SMALL BUSINESS OCCUPANCY <\/td>\n<\/tr>\n
32<\/td>\nTABLE 403.1 MINIMUM NUMBER OF REQUIRED PLUMBING FIXTURES <\/td>\n<\/tr>\n
33<\/td>\nTABLE 403.1 PLUMBING FIXTURES FOR OUTDOOR PUBLIC SWIMMING POOLS
TABLE 403.1 MINIMUM NUMBER OF REQUIRED PLUMBING FIXTURES
IMAGE: PUBLIC SWIMMING POOL <\/td>\n<\/tr>\n
34<\/td>\nIMAGE: PLUMBING FIXTURES FOR OUTDOOR PUBLIC SWIMMING POOLS ARE DETERMINED BY THE ISPSC <\/td>\n<\/tr>\n
35<\/td>\n403.1.2 SINGLE USER TOILET FACILITY IDENTIFICATION
IMAGE: SINGLE-USER RESTROOM FOR USE BY EITHER SEX <\/td>\n<\/tr>\n
36<\/td>\n403.1.3 DISTRIBUTION OF LAVATORIES
IMAGE: NUMBER OF LAVATORIES NOT PROPORTIONAL TO THE NUMBER OF WATER CLOSETS <\/td>\n<\/tr>\n
37<\/td>\n403.2 FACILITIES FOR SMALL BUSINESS OCCUPANCIES
IMAGE: SMALL BUSINESS OCCUPANCIES NEED NOT HAVE SEPARATE TOILET FACILITIES <\/td>\n<\/tr>\n
38<\/td>\n403.3 LOCATION OF REQUIRED TOILET FACILITES
IMAGE: CENTRAL TOILET FACILITY FOR TENANT SPACES <\/td>\n<\/tr>\n
39<\/td>\n405.3.1 CLEARANCE OF PLUMBING FIXTURES TO OBSTRUCTIONS
FIGURE: MINIMUM FIXTURE CLEARANCES <\/td>\n<\/tr>\n
40<\/td>\n405.3.5 MINIMUM DIMENSION BETWEEN URINAL PARTITIONS
FIGURE: MINIMUM CLEARANCE BETWEN URIAL PARTITIONS <\/td>\n<\/tr>\n
41<\/td>\n405.5 PUMPED WASTE PLUMBING FIXTURES
IMAGE: PUMPED WASTE FIXTURE <\/td>\n<\/tr>\n
42<\/td>\n409.1 RESIDENTIAL DISHWASHER STANDARD
IMAGE: RESIDENTIAL DISHWATER <\/td>\n<\/tr>\n
43<\/td>\n409.4 RESIDENTIAL DISHWASHER WASTE CONNECTION
FIGURE: RESIDENTIAL DISHWASHER WASTE CONNECTION <\/td>\n<\/tr>\n
44<\/td>\n411.3 EMERGENCY SHOWER TEMPERATURE CONTROL
IMAGE: EMERGENCY EYEWASH
IMAGE: EMERGENCY SHOWER AND EYEWASH STATION <\/td>\n<\/tr>\n
45<\/td>\n412.7 FLOW LIMITING DEVICE FOR HOT WATER DISCHARGE
IMAGE: TEMPERATURE-ACTUATED FLOW REDUCTION DEVICE <\/td>\n<\/tr>\n
46<\/td>\n422 HEALTH CARE REQUIREMENTS
IMAGE: HOSPITAL STERILIZER NOT COVERED BY THE CODE <\/td>\n<\/tr>\n
47<\/td>\n502.1 SOLAR WATER HEATING SYSTEM STANDARD
IMAGE: SOLAR THERMAL COLLECTOR <\/td>\n<\/tr>\n
48<\/td>\nIMAGE: SOLAR THERMAL WATER HEATING SYSTEMS MUST CONFORM TO ICC 900\/SRCC 300 <\/td>\n<\/tr>\n
49<\/td>\n504.6 INSERT FITTINGS ON T&P VALVE PIPING
IMAGE: INSERT FITTING FOR PIPING <\/td>\n<\/tr>\n
50<\/td>\n504.7 WATER HEATER DRAIN PAN MATERIALS
IMAGE: WATER HEATER DRAIN PAN <\/td>\n<\/tr>\n
51<\/td>\n602.3.1 STANDARD FOR WATER WELL CONSTRUCTION
IMAGE: WATER WELL <\/td>\n<\/tr>\n
52<\/td>\n605.13.7, 605.14.4, 605.16.3 PUSH-FIT JOINTS FOR COPPER, CPVC, PEX AND PE-RT TUBING
TABLE 605.5 PIPE FITTINGS
IMAGE: PUSH FIT FITTING <\/td>\n<\/tr>\n
53<\/td>\n607.3 THERMAL EXPANSION CONTROL DEVICES
IMAGE: THERMAL EXPANSION CONTROL DEVICE
IMAGE: THERMAL EXPANSION TANK <\/td>\n<\/tr>\n
54<\/td>\n608.3, 608.4 BACKFLOW PROTECTION FOR WATER HANDLING EQUIPMENT
IMAGE: WATER SOFTENER
IMAGE: WATER FILTER HOUSING <\/td>\n<\/tr>\n
55<\/td>\n608.12 NSF 61-COMPLIANT TANKS FOR DRINKING WATER
IMAGE: POTABLE WATER TANK <\/td>\n<\/tr>\n
56<\/td>\n608.17.1.1, 608.17.1.2 INDEPENDENT BACKFLOW PROTECTION FOR DRINK DISPENSERS
FIGURE: INDEPENDENT BACKFLOW PROTECTION <\/td>\n<\/tr>\n
57<\/td>\n608.17.10 HUMIDIFIER BACKFLOW PREVENTER
FIGURE: BACKFLOW PREVENTER FOR HUMIDIFIER <\/td>\n<\/tr>\n
58<\/td>\n609.1 MEDICAL FACILITY TERMINOLOGY
IMAGE: GROUP I-1 ASSISTED LIVING FACILITY <\/td>\n<\/tr>\n
59<\/td>\n611.1 POINT OF USE REVERSE OSMOSIS SYSTEMS
IMAGE: REVERSE OSMOSIS SYSTEM <\/td>\n<\/tr>\n
60<\/td>\n701.2 CONNECTION TO SEWER SYSTEMS
FIGURE: DIVERSION OF GRAY WATER FROM PUBLIC SEWER
IMAGE: WHERE STATE REQUIREMENTS DO NOT EXIST, PRIVATE SEWAGE DISPOSAL SYSTEMS MUST COMPLY WITH THE IPSDC <\/td>\n<\/tr>\n
61<\/td>\n701.8 DRAINAGE PIPING ABOVE FOOD AREAS
FIGURE: CEILING OR “DRIP TRAYS” UNDER PIPING ABOVE FOOD AREAS NOT REQUIRED <\/td>\n<\/tr>\n
62<\/td>\n702.3 POLYPROPYLENE PIPING FOR BUILDING SEWER
TABLE 702.3 BUILDING SEWER PIPE
IMAGE: SMOOTH INNER WALL POLYPROPYLENE PIPING FOR SEWER SERVICE <\/td>\n<\/tr>\n
63<\/td>\n703.4 REUSE OF BURIED DRAIN AND SEWER PIPING
FIGURE: OLD EXISTING BUILDING SEWER NEED NOT BE REPLACED <\/td>\n<\/tr>\n
64<\/td>\n704.1 GREASE-LADEN WASTE PIPING SLOPE
FIGURE: DRAINAGE PIPING SLOPE TO GREASE INTERCEPTOR <\/td>\n<\/tr>\n
65<\/td>\n704.2 REDUCTION OF PIPE SIZE
IMAGE: WATER CLOSET FLANGE
IMAGE: 4 X 3 WATER CLOSET BEND
IMAGE: OFFSET CLOSET FLANGE <\/td>\n<\/tr>\n
66<\/td>\n705.16.4 PVC TO ABS SOLVENT CEMENT JOINT
IMAGE: PVC TO ABS CEMENTED JOINT <\/td>\n<\/tr>\n
67<\/td>\n709.3 GPM DRAINAGE FLOW TO DFU CONVERSION
FIGURE: CONVERSION FROM GPM TO DFU <\/td>\n<\/tr>\n
68<\/td>\n712.3.2 EJECTOR SUMP COVER ELEVATION
FIGURE: ELEVATION OF FLOOR WITH RESPECT TO SUMP COVER <\/td>\n<\/tr>\n
69<\/td>\n712.4.2 WASTE EJECTOR SOLIDS SIZE REDUCED
FIGURE: SINK PUMP SYSTEM <\/td>\n<\/tr>\n
70<\/td>\n713 HEALTH CARE PLUMBING
IMAGE <\/td>\n<\/tr>\n
71<\/td>\n716 PIPE BURSTING REPLACEMENT OF BUILDING DRAINS
IMAGE: PIPE BURSTING BUILDING DRAINAGE PIPING <\/td>\n<\/tr>\n
72<\/td>\n801.2, 802.1 CONNECTION OF HUMIDIFIER DRAINS
IMAGE: HUMIDIFIER DRAIN <\/td>\n<\/tr>\n
73<\/td>\n802.4.3.1 LAUNDRY TUB CONNECTION TO CLOTHES WASHER STANDPIPE
FIGURE: LAUNDRY TRAY CONNECTED TO CLOTHES WASHER STANDPIPE <\/td>\n<\/tr>\n
74<\/td>\n918.8 PROHIBITED INSTALLATIONS FOR AIR ADMITTANCE VALVES
FIGURE: IMPROPER USE OF AAV <\/td>\n<\/tr>\n
75<\/td>\n1003.3.2 DISCHARGE OF DISPOSERS TO GREASE INTERCEPTORS PROHIBITED
FIGURE: FOOD WASTE DISPOSER MUST CONNECT AFTER GREASE INTERCEPTOR <\/td>\n<\/tr>\n
76<\/td>\n1003.3.3 ADDITIVES TO GREASE INTERCEPTORS
FIGURE: AEROBIC BIOREMEDIATION ADDITIVES <\/td>\n<\/tr>\n
77<\/td>\nTABLE 1102.4 TYPES OF PIPING FOR STORM SEWERS
TABLE 1102.4 BUILDING STORM SEWER PIPE
IMAGE: VARIOUS TYPES OF PVC PIPE ARE PERMITTED FOR STORM SEWERS
IMAGE: WIDER ARRAY OF BUILDING STORM SEWER PIPING <\/td>\n<\/tr>\n
78<\/td>\n1106.5 ROOF DRAINAGE SCUPPERS
IMAGE: SCUPPER <\/td>\n<\/tr>\n
79<\/td>\n1302.7.2 GRAY WATER STORAGE TANKS
IMAGE: GRAY WATER STORAGE TANK <\/td>\n<\/tr>\n
80<\/td>\n1303.1.1 NONPOTABLE WATER FOR FIRE PROTECTION SYSTEMS
IMAGE: NONPOTABLE WATER TANKS FOR FIRE PROTECTION SYSTEMS <\/td>\n<\/tr>\n
81<\/td>\n1303.15.8, 1303.15.9 RAINWATER QUALITY <\/td>\n<\/tr>\n
82<\/td>\nIMAGE: JURISDICATION DETERMINES THE REQUIRED WATER QUALITY FOR AN APPLICATION <\/td>\n<\/tr>\n
84<\/td>\nPART 2: INTERNATIONAL MECHANICAL CODE – CHAPTERS 1 THROUGH 15 <\/td>\n<\/tr>\n
86<\/td>\n202 DEFINITION OF COMMERCIAL COOKING APPLIANCE <\/td>\n<\/tr>\n
87<\/td>\nIMAGE: COMMERCIAL KITCHEN <\/td>\n<\/tr>\n
88<\/td>\n403.3.2.4 OUTDOOR AIR VENTILATION FOR DWELLING UNITS
IMAGE: LABELING OF CONTROLS FOR WHOLE HOUSE VENTILATION SYSTEMS <\/td>\n<\/tr>\n
89<\/td>\n403.3.2.5 DWELLING UNIT VENTILATING EQUIPMENT
IMAGE: EXHAUST EQUIPMENT MUST BE LISTED AND LABELED <\/td>\n<\/tr>\n
90<\/td>\n404.1 MECHANICAL VENTILATION OF ENCLOSED PARKING GARAGES
IMAGE: CONTINUOUS OR AUTOMATIC MECHANICAL VENTILATION IS REQUIRED FOR ENCLOSED PARKING GARAGES. AUTOMATIC VENTILATION MUST CYCLE BETWEEN FULL ON AND STANDBY AIRFLOW RATES <\/td>\n<\/tr>\n
91<\/td>\n504.4 SEALING OF CLOTHES DRYER EXHAUST DUCTS
IMAGE: JOINTS IN DRYER EXHAUST DUCT MUST BE SEALED <\/td>\n<\/tr>\n
92<\/td>\n504.4.1 CLOTHES DRYER EXHAUST TERMINATION
IMAGE: DRYER DUCT TERMINALS MUST PROVIDE A MINIMUM OPENING OF 12.5 SQUARE INCHES <\/td>\n<\/tr>\n
93<\/td>\n504.8.2 DRYER EXHAUST DUCTS IN FRAMING CAVITIES
IMAGE: FRAMING CAVITIES MUST BE LARGE ENOUGH TO ALLOW A 4 INCH EXHAUST DUCT WITHOUT DEFORMATION <\/td>\n<\/tr>\n
94<\/td>\n506.3.13 TYPE I HOOD EXHAUST TERMINATION <\/td>\n<\/tr>\n
95<\/td>\nFIGURE: CLEARANCES TO OPENINGS FOR TYPE I EXHAUST DUCT TERMINATIONS <\/td>\n<\/tr>\n
96<\/td>\n506.5.2, 202 POLLUTION CONTROL UNITS <\/td>\n<\/tr>\n
97<\/td>\nIMAGE: POLLUTION CONTROL UNIT <\/td>\n<\/tr>\n
98<\/td>\n507.2.6 CLEARANCES FOR TYPE I HOOD
IMAGE: TYPE I HOOD <\/td>\n<\/tr>\n
99<\/td>\n602.2.1.8 PIPE AND DUCT INSULATION WITHIN PLENUMS
IMAGE: PIPE AND DUCT INSULATION FOR USE IN PLENUMS MUST MEET THE LIMITATIONS AND CONDITIONS SPECIFIED IN SECTION 602.2.1.8 <\/td>\n<\/tr>\n
100<\/td>\n603.5.2 PHENOLIC DUCTS
IMAGE: NONMETALLIC PHENOLIC DUCTS <\/td>\n<\/tr>\n
101<\/td>\n603.8.2 TESTING OF UNDERGROUND DUCTS
IMAGE: UNDERGROUND DUCTS REQUIRE AN AIR LEAKAGE TEST BEFORE BURIAL <\/td>\n<\/tr>\n
102<\/td>\n603.9 SNAP-LOCK AND BUTTON-LOCK DUCT JOINTS <\/td>\n<\/tr>\n
103<\/td>\nFIGURE: BUTTON-LOCK AND SNAP-LOCK DUCT SEAMS <\/td>\n<\/tr>\n
104<\/td>\n607.3.1 CEILING RADIATION DAMPERS
FIGURE: CEILING RADIATION DAMPER IN A SUSPENDED CEILING <\/td>\n<\/tr>\n
105<\/td>\n929, 202 HIGH-VOLUME LARGE-DIAMETER FANS <\/td>\n<\/tr>\n
106<\/td>\nIMAGE: HIGH-VOLUME LARGE-DIAMETER FAN <\/td>\n<\/tr>\n
107<\/td>\n1105.6.3 AMMONIA SYSTEM VENTILATION RATE
FIGURE: THE MINIMUM EMERGENCY VENTILATION RATE FOR AMMONIA IS 30 ACH PER IIAR2 <\/td>\n<\/tr>\n
108<\/td>\n1107.2 REFRIGERANT PIPING LOCATION
IMAGE: REFRIGERANT PIPING IS NOT PERMITTED IN AN INTERIOR EXIT STAIRWAY, AMONG OTHER SPECIFIED LOCATIONS <\/td>\n<\/tr>\n
109<\/td>\nCHAPTER 14 SOLAR THERMAL SYSTEMS <\/td>\n<\/tr>\n
110<\/td>\nIMAGE: SOLAR THERMAL SYSTEMS SHALL BE LISTED AND LABELED IN ACCORDANCE WITH ICC 900\/SRCC 300
IMAGE: SOLAR THERMAL COLLECTORS AND PANELS SHALL BE LISTED AND LABELED IN ACCORDANCE WITH ICC901\/SRCC 100 <\/td>\n<\/tr>\n
112<\/td>\nPART 3: INTERNATIONAL FUEL GAS CODE – CHAPTERS 1 THROUGH 8 <\/td>\n<\/tr>\n
114<\/td>\n303.3 GAS-FIRED CLOTHES DRYER IN BATHROOMS <\/td>\n<\/tr>\n
115<\/td>\nFIGURE: A GAS CLOTHES DRYER IS PERMITTED IN A BATHROOM WHERE A PERMANENT OPENING IS INSTALLED FOR VENTILATION\/MAKEUP AIR <\/td>\n<\/tr>\n
116<\/td>\n310.2, 310.3 BONDING OF CSST AND ARC-RESISTANT CSST
IMAGE: ARC-RESISTANT CSST IS CONSIDERED TO BE BONDED WHERE CONNECTED TO AN APPLIANCE THAT IS SERVED BY AN EQUIPMENT GROUNDING CONDUCTOR <\/td>\n<\/tr>\n
117<\/td>\nIMAGE: NON-ARC-RESISTANT CSST
IMAGE: ARC-RESISTANT CSST <\/td>\n<\/tr>\n
118<\/td>\n310.2.3 GROUNDING ELECTRODES FOR CSST BONDING
FIGURE: AN ADDITIONAL GROUNDING ELECTRODE CAN BE INSTALLED TO STAY WITHIN THE LENGTH LIMITATION OF 75 FEET <\/td>\n<\/tr>\n
119<\/td>\n403.4.2, 403.10.1 SCHEDULE 10 STEEL GAS PIPE <\/td>\n<\/tr>\n
120<\/td>\nFIGURE: PRESS FITTINGS USE ELASTOMERIC SEALS AND SPECIAL EQUIPMENT TO JOIN STEEL GAS PIPING <\/td>\n<\/tr>\n
121<\/td>\n404.11 CORROSION PROTECTION FOR STEEL GAS PIPE <\/td>\n<\/tr>\n
122<\/td>\nFIGURE: FACTORY APPLIED CORROSION PROTECTION FOR UNDERGROUND STEEL PIPE
FIGURE: ANODELESS RISER <\/td>\n<\/tr>\n
123<\/td>\n404.14 PIPING UNDERGROUND BENEATH BUILDINGS
IMAGE: UNDERGROUND CSST
IMAGE: GAS PIPING LISTED FOR INSTALLATION BENEATH BUILDINGS <\/td>\n<\/tr>\n
124<\/td>\nIMAGE: UNDERGROUND CSST
IMAGE: UNDERGROUND CSST <\/td>\n<\/tr>\n
125<\/td>\n409.5.1 ACCESS TO SHUTOFF VALVES FOR MOVABLE APPLIANCES
FIGURE: SHUTOFF VALVES BEHIND MOVABLE APPLIANCES ARE CONSIDERED AS MEETING THE REQUIREMENT FOR ACCESS <\/td>\n<\/tr>\n
126<\/td>\n409.7 SHUTOFF VALVE SUPPORT FOR TUBING SYSTEMS
FIGURE: KEY HANDLE VALVE WITH SUPPORT INDEPENDENT OF GAS TUBING
FIGURE: SHUTOFF VALVES REQUIRE SUPPORT INDEPENDENT OF GAS TUBING <\/td>\n<\/tr>\n
127<\/td>\n410.2 MP REGULATOR AND APPLIANCE PRESSURE TEST PORT <\/td>\n<\/tr>\n
128<\/td>\nFIGURE: COMBINATION GAS VALVE WITH PRESSURE TEST PORT ON THE GAS CONTROL INLET SIDE <\/td>\n<\/tr>\n
129<\/td>\n503.4.1, 503.4.2 STANDARDS FOR PLASTIC PIPE VENTING MATERIALS <\/td>\n<\/tr>\n
130<\/td>\nFIGURE: POLYPROPYLENE PLASTIC VENT SYSTEM
FIGURE: POLYPROPYLENE PLASTIC VENT SYSTEM
FIGURE: PLASTIC VENT SYSTEM CONFORMING TO UL 1738
FIGURE: SAMPLE OF FITTING LABEL FOR UL LISTED PLASTIC VENT SYSTEM <\/td>\n<\/tr>\n
131<\/td>\n503.8 DIRECT-VENT TERMINATION CLEARANCES
TABLE 503.8 THROUGH-THE-WALL DIRECT-VENT TERMINATION CLEARANCES <\/td>\n<\/tr>\n
132<\/td>\nFIGURE: THROUGH-THE-WALL DIRECT VENT TERMINATION FOR APPLIANCES GREATER THAN 150, 000 BTU\/HR INPUT <\/td>\n<\/tr>\n
134<\/td>\nINDEX <\/td>\n<\/tr>\n
140<\/td>\nTAKE YOUR CAREER FURTHER, FASTER WITH ICC MEMBERSHIP <\/td>\n<\/tr>\n
141<\/td>\nHAVE YOU SEEN ICC’S DIGITAL LIBRARY LATELY? <\/td>\n<\/tr>\n
143<\/td>\nINTRODUCING THE ICC ASSESSMENT CENTER, FEATURING PRONTO <\/td>\n<\/tr>\n<\/table>\n","protected":false},"excerpt":{"rendered":"

Significant Changes to the IPC, IMC, and IFGC, 2018 Edition<\/b><\/p>\n\n\n\n\n
Published By<\/td>\nPublication Date<\/td>\nNumber of Pages<\/td>\n<\/tr>\n
ICC<\/b><\/a><\/td>\n2018<\/td>\n143<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n","protected":false},"featured_media":202540,"template":"","meta":{"rank_math_lock_modified_date":false,"ep_exclude_from_search":false},"product_cat":[2670],"product_tag":[],"class_list":{"0":"post-202539","1":"product","2":"type-product","3":"status-publish","4":"has-post-thumbnail","6":"product_cat-icc","8":"first","9":"instock","10":"sold-individually","11":"shipping-taxable","12":"purchasable","13":"product-type-simple"},"_links":{"self":[{"href":"https:\/\/pdfstandards.shop\/wp-json\/wp\/v2\/product\/202539","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/pdfstandards.shop\/wp-json\/wp\/v2\/product"}],"about":[{"href":"https:\/\/pdfstandards.shop\/wp-json\/wp\/v2\/types\/product"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/pdfstandards.shop\/wp-json\/wp\/v2\/media\/202540"}],"wp:attachment":[{"href":"https:\/\/pdfstandards.shop\/wp-json\/wp\/v2\/media?parent=202539"}],"wp:term":[{"taxonomy":"product_cat","embeddable":true,"href":"https:\/\/pdfstandards.shop\/wp-json\/wp\/v2\/product_cat?post=202539"},{"taxonomy":"product_tag","embeddable":true,"href":"https:\/\/pdfstandards.shop\/wp-json\/wp\/v2\/product_tag?post=202539"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}