{"id":226411,"date":"2024-10-19T14:42:53","date_gmt":"2024-10-19T14:42:53","guid":{"rendered":"https:\/\/pdfstandards.shop\/product\/uncategorized\/bs-en-iec-62386-3332018\/"},"modified":"2024-10-25T08:39:33","modified_gmt":"2024-10-25T08:39:33","slug":"bs-en-iec-62386-3332018","status":"publish","type":"product","link":"https:\/\/pdfstandards.shop\/product\/publishers\/bsi\/bs-en-iec-62386-3332018\/","title":{"rendered":"BS EN IEC 62386-333:2018"},"content":{"rendered":"

This part of IEC 62386<\/span> <\/span> specifies a bus system for control by digital signals of electronic lighting equipment which is in line with the requirements of IEC 61347<\/span> (all parts)<\/span>.<\/p>\n

This document is applicable to IEC 62386\u2011103:2014<\/span> <\/span> and IEC 62386\u2011103:2014\/AMD1<\/span> <\/span>: \u2014control devices supporting manual configuration.<\/p>\n

\n
\n NOTE\n <\/div>\n

Requirements for testing individual products during production are not included.<\/p>\n<\/div>\n

PDF Catalog<\/h4>\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n
PDF Pages<\/th>\nPDF Title<\/th>\n<\/tr>\n
2<\/td>\nundefined <\/td>\n<\/tr>\n
7<\/td>\nCONTENTS <\/td>\n<\/tr>\n
9<\/td>\nFOREWORD <\/td>\n<\/tr>\n
11<\/td>\nINTRODUCTION
Figure 1 \u2013 IEC 62386 graphical overview <\/td>\n<\/tr>\n
13<\/td>\n1 Scope
2 Normative references
3 Terms and definitions <\/td>\n<\/tr>\n
14<\/td>\n4 General
4.1 General
4.2 Version number
4.3 Insulation
5 Electrical specification
6 Interface power supply
7 Transmission protocol structure
7.1 General
7.2 Frame format for event messages <\/td>\n<\/tr>\n
15<\/td>\n8 Timing
9 Method of operation
9.1 General
9.2 Feature type
9.3 Events
9.3.1 General
9.3.2 Priority use
9.3.3 Bus usage
Tables
Table 1 \u2013 24-bit event message frame encoding \u2018manual configuration\u2019 <\/td>\n<\/tr>\n
16<\/td>\n9.3.4 Encoding
9.3.5 Event generation
Table 2 \u2013 Event source information \u2018manual configuration\u2019 <\/td>\n<\/tr>\n
17<\/td>\n9.3.6 Power interruption
9.3.7 Manual configuration affecting multiple variables
9.4 Configuring the feature
9.4.1 General
9.4.2 Manual capability <\/td>\n<\/tr>\n
18<\/td>\nTable 3 \u2013 \u201cmanualCapabilityDevice\u201d encoding
Table 4 \u2013 \u201cmanualCapabilityInstance103\u201d encoding <\/td>\n<\/tr>\n
19<\/td>\n9.4.3 Enable\/disable manual configuration
Table 5 \u2013 \u201cmanualConfigDevice\u201d encoding <\/td>\n<\/tr>\n
20<\/td>\nTable 6 \u2013 \u201cmanualConfigInstance103\u201d encoding <\/td>\n<\/tr>\n
21<\/td>\n9.4.4 Querying any manual configuration enabled
9.4.5 Manual configuration behaviour <\/td>\n<\/tr>\n
22<\/td>\n10 Declaration of variables
Table 7 \u2013 Declaration of additions and restrictions to existing device variables <\/td>\n<\/tr>\n
23<\/td>\n11 Definition of commands
11.1 General
11.2 Overview sheets
11.2.1 General
11.2.2 Standard commands
Table 8 \u2013 Declaration of additions and restrictions to existing instance variables <\/td>\n<\/tr>\n
24<\/td>\nTable 9 \u2013 Additional feature commands <\/td>\n<\/tr>\n
25<\/td>\n11.3 Event messages
11.3.1 General
11.3.2 Manual configuration event
11.4 Device control instructions
11.5 Device configuration instructions
11.5.1 General
11.5.2 RESET
11.6 Device queries
11.7 Instance control instructions
11.8 Instance configuration instructions
11.9 Instance queries
11.10 Special commands
11.11 Feature configuration instructions
11.11.1 General <\/td>\n<\/tr>\n
26<\/td>\n11.11.2 SET MANUAL CONFIGURATION 103 (DTR0)
11.11.3 SET MANUAL CONFIGURATION 3xx (DTR0)
11.11.4 SET MANUAL CONFIGURATION FEATURE 3xx (DTR0)
11.12 Feature queries
11.12.1 General <\/td>\n<\/tr>\n
27<\/td>\n11.12.2 QUERY MANUAL CONFIGURATION CAPABILITY 103
11.12.3 QUERY MANUAL CONFIGURATION CAPABILITY 3xx
11.12.4 QUERY MANUAL CONFIGURATION CAPABILITY FEATURE 3xx
11.12.5 QUERY MANUAL CONFIGURATION 103
11.12.6 QUERY MANUAL CONFIGURATION 3xx <\/td>\n<\/tr>\n
28<\/td>\n11.12.7 QUERY MANUAL CONFIGURATION FEATURE 3xx
11.12.8 QUERY ANY MANUAL CONFIGURATION ENABLED <\/td>\n<\/tr>\n
29<\/td>\nBibliography <\/td>\n<\/tr>\n<\/table>\n","protected":false},"excerpt":{"rendered":"

Digital addressable lighting interface – Particular requirements for control devices. Manual configuration (feature type 33)<\/b><\/p>\n\n\n\n\n
Published By<\/td>\nPublication Date<\/td>\nNumber of Pages<\/td>\n<\/tr>\n
BSI<\/b><\/a><\/td>\n2018<\/td>\n30<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n","protected":false},"featured_media":226413,"template":"","meta":{"rank_math_lock_modified_date":false,"ep_exclude_from_search":false},"product_cat":[526,2641],"product_tag":[],"class_list":{"0":"post-226411","1":"product","2":"type-product","3":"status-publish","4":"has-post-thumbnail","6":"product_cat-29-140-99","7":"product_cat-bsi","9":"first","10":"instock","11":"sold-individually","12":"shipping-taxable","13":"purchasable","14":"product-type-simple"},"_links":{"self":[{"href":"https:\/\/pdfstandards.shop\/wp-json\/wp\/v2\/product\/226411","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/pdfstandards.shop\/wp-json\/wp\/v2\/product"}],"about":[{"href":"https:\/\/pdfstandards.shop\/wp-json\/wp\/v2\/types\/product"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/pdfstandards.shop\/wp-json\/wp\/v2\/media\/226413"}],"wp:attachment":[{"href":"https:\/\/pdfstandards.shop\/wp-json\/wp\/v2\/media?parent=226411"}],"wp:term":[{"taxonomy":"product_cat","embeddable":true,"href":"https:\/\/pdfstandards.shop\/wp-json\/wp\/v2\/product_cat?post=226411"},{"taxonomy":"product_tag","embeddable":true,"href":"https:\/\/pdfstandards.shop\/wp-json\/wp\/v2\/product_tag?post=226411"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}