{"id":233894,"date":"2024-10-19T15:15:14","date_gmt":"2024-10-19T15:15:14","guid":{"rendered":"https:\/\/pdfstandards.shop\/product\/uncategorized\/bs-iec-60747-18-12019\/"},"modified":"2024-10-25T09:46:22","modified_gmt":"2024-10-25T09:46:22","slug":"bs-iec-60747-18-12019","status":"publish","type":"product","link":"https:\/\/pdfstandards.shop\/product\/publishers\/bsi\/bs-iec-60747-18-12019\/","title":{"rendered":"BS IEC 60747-18-1:2019"},"content":{"rendered":"

This part of IEC 60747 specifies the test methods and data analysis for the calibration of lens-free CMOS photonic array sensors. This document includes the test conditions of each process, configuration of lens-free CMOS photonic array sensors, statistical analysis of test data, calibration for planarization and linearity, and test reports.<\/p>\n

PDF Catalog<\/h4>\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n
PDF Pages<\/th>\nPDF Title<\/th>\n<\/tr>\n
2<\/td>\nundefined <\/td>\n<\/tr>\n
4<\/td>\nCONTENTS <\/td>\n<\/tr>\n
6<\/td>\nFOREWORD <\/td>\n<\/tr>\n
8<\/td>\nINTRODUCTION <\/td>\n<\/tr>\n
10<\/td>\n1 Scope
2 Normative references
3 Terms and definitions <\/td>\n<\/tr>\n
11<\/td>\n4 Measurement setup
4.1 General
4.2 Measurement system
4.2.1 Overall system
Figures
Figure 1 \u2013 Example of box plot <\/td>\n<\/tr>\n
12<\/td>\nFigure 2 \u2013 Example of measurement system with integrating sphere
Figure 3 \u2013 Example of measurement system with incident parallel light <\/td>\n<\/tr>\n
13<\/td>\n4.2.2 Dark box
4.2.3 Light source
4.2.4 Sensor board
Figure 4 \u2013 Example of photoelectric measurement schematic <\/td>\n<\/tr>\n
14<\/td>\n4.2.5 Configuration parameters
5 Measurement
5.1 General
5.2 Case 1: Fixed wavelength (\u03bb) of light
5.2.1 Planarization: At fixed \u03bb and incident light intensity
Figure 5 \u2013 Measurement flow <\/td>\n<\/tr>\n
15<\/td>\nFigure 6 \u2013 n trial data of frame capture
Figure 7 \u2013 Two frame subtracted data <\/td>\n<\/tr>\n
16<\/td>\n5.2.2 Linearity: Varying the incident light intensity with a fixed wavelength
5.3 Case 2: Various wavelength (\u03bb) of light
6 Data analysis
6.1 Data plot
6.1.1 General
Figure 8 \u2013 Dark frame subtracted data <\/td>\n<\/tr>\n
17<\/td>\nFigure 9 \u2013 Example of output electric signal non-linearity of 2D pixel array
Figure 10 \u2013 Example of output electric signal non-linearity of one row of pixels <\/td>\n<\/tr>\n
18<\/td>\n6.1.2 Sensor screening
6.2 Planarization characteristics
6.2.1 Criterion of determining the reference pixel
Figure 11 \u2013 Example of one pixel\u2019s output electric signal according to input light power <\/td>\n<\/tr>\n
19<\/td>\n6.2.2 Lookup table of representative value for planarization calibration of each pixel
6.3 Linearity
6.3.1 Criterion of linear region of each pixel
Figure 12 \u2013 Example of determining the reference pixel
Figure 13 \u2013 Example of the representative value for planarization <\/td>\n<\/tr>\n
20<\/td>\n6.3.2 Criterion of light intensity effective area for linearity
6.3.3 Lookup table of the representative value for linearity calibration of each pixel
Figure 14 \u2013 Example of light intensity effective area for linearity <\/td>\n<\/tr>\n
21<\/td>\n7 Calibration
7.1 Calibration lookup table
Figure 15 \u2013 Example of the representative value for linearity
Figure 16 \u2013 Example of a simplified pixel structure and cross-sectional viewwith bio reaction <\/td>\n<\/tr>\n
22<\/td>\n7.2 Reference for establishing the representative output value in the effective area
Table 1 \u2013 Calibration lookup table <\/td>\n<\/tr>\n
23<\/td>\n8 Test report
Figure 17 \u2013 Example of the representative value of the sensor
Table 2 \u2013 Representative value table of the sensor <\/td>\n<\/tr>\n
25<\/td>\nAnnex A (informative)Test report
A.1 Test environment specification <\/td>\n<\/tr>\n
26<\/td>\nA.2 Specification of CMOS photonic array sensor
A.3 Calibration lookup table
A.4 Representative value look up table for planarization calibration of the sensor <\/td>\n<\/tr>\n
27<\/td>\nA.5 Representative value look up table for linearity calibration of the sensor <\/td>\n<\/tr>\n
28<\/td>\nBibliography <\/td>\n<\/tr>\n<\/table>\n","protected":false},"excerpt":{"rendered":"

Semiconductor devices – Semiconductor bio sensors. Test method and data analysis for calibration of lens-free CMOS photonic array sensors<\/b><\/p>\n\n\n\n\n
Published By<\/td>\nPublication Date<\/td>\nNumber of Pages<\/td>\n<\/tr>\n
BSI<\/b><\/a><\/td>\n2019<\/td>\n30<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n","protected":false},"featured_media":233896,"template":"","meta":{"rank_math_lock_modified_date":false,"ep_exclude_from_search":false},"product_cat":[577,2641],"product_tag":[],"class_list":{"0":"post-233894","1":"product","2":"type-product","3":"status-publish","4":"has-post-thumbnail","6":"product_cat-31-080-99","7":"product_cat-bsi","9":"first","10":"instock","11":"sold-individually","12":"shipping-taxable","13":"purchasable","14":"product-type-simple"},"_links":{"self":[{"href":"https:\/\/pdfstandards.shop\/wp-json\/wp\/v2\/product\/233894","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/pdfstandards.shop\/wp-json\/wp\/v2\/product"}],"about":[{"href":"https:\/\/pdfstandards.shop\/wp-json\/wp\/v2\/types\/product"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/pdfstandards.shop\/wp-json\/wp\/v2\/media\/233896"}],"wp:attachment":[{"href":"https:\/\/pdfstandards.shop\/wp-json\/wp\/v2\/media?parent=233894"}],"wp:term":[{"taxonomy":"product_cat","embeddable":true,"href":"https:\/\/pdfstandards.shop\/wp-json\/wp\/v2\/product_cat?post=233894"},{"taxonomy":"product_tag","embeddable":true,"href":"https:\/\/pdfstandards.shop\/wp-json\/wp\/v2\/product_tag?post=233894"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}