{"id":241959,"date":"2024-10-19T15:51:12","date_gmt":"2024-10-19T15:51:12","guid":{"rendered":"https:\/\/pdfstandards.shop\/product\/uncategorized\/bs-en-61000-4-192014\/"},"modified":"2024-10-25T10:42:14","modified_gmt":"2024-10-25T10:42:14","slug":"bs-en-61000-4-192014","status":"publish","type":"product","link":"https:\/\/pdfstandards.shop\/product\/publishers\/bsi\/bs-en-61000-4-192014\/","title":{"rendered":"BS EN 61000-4-19:2014"},"content":{"rendered":"
This part of IEC 61000<\/span> <\/span> relates to the immunity requirements and test methods for electrical and electronic equipment to conducted, differential mode disturbances and signalling in the range 2 kHz up to 150 kHz at a.c. power ports.<\/p>\n The object of this standard is to establish a common and reproducible basis for testing electrical and electronic equipment with the application of differential mode disturbances and signalling to a.c. power ports. This standard defines:<\/p>\n test waveforms;<\/p>\n<\/li>\n range of test levels;<\/p>\n<\/li>\n test equipment;<\/p>\n<\/li>\n test setup;<\/p>\n<\/li>\n test procedures;<\/p>\n<\/li>\n verification procedures.<\/p>\n<\/li>\n<\/ul>\n These tests are intended to demonstrate the immunity of electrical and electronic equipment operating at a mains supply voltage up to 280 V (from phase to neutral or phase to earth, if no neutral is used) and a frequency of 50 Hz or 60 Hz when subjected to conducted, differential mode disturbances such as those originating from power electronics and power line communication systems (PLC).<\/p>\n In some countries, the maximum voltage can be as much as 350 V from phase to neutral.<\/p>\n<\/div>\n The immunity to harmonics and interharmonics, including mains signalling, on a.c. power ports up to 2 kHz in differential mode is covered by IEC 61000\u20114\u201113<\/span> <\/span>.<\/p>\n Emissions in the frequency range 2 kHz to 150 kHz often have both differential mode and common mode components. This standard provides immunity tests only for differential mode disturbances and signalling. It is recommended to perform common mode tests as well, which are covered by IEC 61000\u20114\u201116<\/span> <\/span>.<\/p>\n Electromagnetic compatibility (EMC) – Testing and measurement techniques. Test for immunity to conducted, differential mode disturbances and signalling in the frequency range 2 kHz to 150 kHz at a.c. power ports<\/b><\/p>\n\n
PDF Catalog<\/h4>\n
\n
\n PDF Pages<\/th>\n PDF Title<\/th>\n<\/tr>\n \n 4<\/td>\n Foreword
Endorsement notice <\/td>\n<\/tr>\n\n 5<\/td>\n Annex ZA (normative) Normative references to international publications with their corresponding European publications <\/td>\n<\/tr>\n \n 6<\/td>\n English
CONTENTS <\/td>\n<\/tr>\n\n 8<\/td>\n INTRODUCTION <\/td>\n<\/tr>\n \n 9<\/td>\n 1 Scope
2 Normative references <\/td>\n<\/tr>\n\n 10<\/td>\n 3 Terms and definitions
3.1 Terms and definitions <\/td>\n<\/tr>\n\n 11<\/td>\n 3.2 Abbreviations
4 General <\/td>\n<\/tr>\n\n 12<\/td>\n 5 Test levels and wave profiles in the frequency range 2 kHz to 150 kHz
5.1 Test levels for differential voltage testing
5.1.1 General
Tables
Table 1 \u2013 Test levels in the 2 kHz to 150 kHz frequency range for differential voltage testing <\/td>\n<\/tr>\n\n 13<\/td>\n 5.1.2 Test wave profile with CW pulses with pause
Figures
Figure 1 \u2013 Frequency vs. amplitude profile for differential voltage testing <\/td>\n<\/tr>\n\n 14<\/td>\n 5.1.3 Test wave profile with rectangularly modulated pulses
5.2 Test levels for differential current testing
5.2.1 General
Figure 2 \u2013 Test wave profile with CW pulses with pause
Figure 3 \u2013 Test wave profile with rectangularly modulated pulses for differential voltage testing <\/td>\n<\/tr>\n\n 15<\/td>\n 5.2.2 Test wave profile with CW pulses with pause
5.2.3 Test wave profile with rectangularly modulated pulses
6 Test equipment
6.1 Test generators
6.1.1 General
Table 2 \u2013 Test levels in the 2 kHz to 150 kHz frequency range for differential current testing <\/td>\n<\/tr>\n\n 16<\/td>\n 6.1.2 Characteristics and performance of the generator for the differential voltage test
6.1.3 Characteristics and performance of the generator for the differential current test
Figure 4 \u2013 Example of a simplified circuit diagram with the major elements of the differential voltage test generator <\/td>\n<\/tr>\n\n 17<\/td>\n 6.2 Verification of the characteristics of the test generators
6.2.1 General
6.2.2 Verification of the generators <\/td>\n<\/tr>\n\n 18<\/td>\n 6.2.3 Verification of the coupling\/decoupling network
Figure 5 \u2013 Test setup for verification of the CDN in a 10 \u03a9 measurement system <\/td>\n<\/tr>\n\n 19<\/td>\n 7 Test setups
7.1 Test setup for differential mode voltage testing
Figure 6 \u2013 Limit for the damping characteristics
\nmeasured in a 10 \u03a9 measurement system
Figure 7 \u2013 Example of test setup for differential mode voltage testing with auxiliary equipment <\/td>\n<\/tr>\n\n 20<\/td>\n 7.2 Test setup for differential mode current test
8 Test procedure
8.1 General
Figure 8 \u2013 Example of test setup for differential mode current testing <\/td>\n<\/tr>\n\n 21<\/td>\n 8.2 Laboratory reference conditions
8.2.1 Climatic conditions
8.2.2 Electromagnetic conditions
8.3 Execution of the test
9 Evaluation of test results <\/td>\n<\/tr>\n\n 22<\/td>\n 10 Test report <\/td>\n<\/tr>\n \n 23<\/td>\n Annex A (informative) Interference sources, victims and effects <\/td>\n<\/tr>\n \n 25<\/td>\n Figure A.1 \u2013 Standards dealing with voltage levels due to non-intentional emissions in the frequency range 2 kHz to 150 kHz <\/td>\n<\/tr>\n \n 26<\/td>\n Figure A.2 \u2013 Standards dealing with voltage levels due to intentional emissions in the frequency range 2 kHz to 150 kHz <\/td>\n<\/tr>\n \n 27<\/td>\n Annex B (informative) Selection of test levels <\/td>\n<\/tr>\n \n 29<\/td>\n Annex C (informative) Testing electricity meters guideline
C.1 Example of the basic structure of a test generator for differential current testing
Figure C.1 \u2013 Simplified circuit of a differential current test generator <\/td>\n<\/tr>\n\n 30<\/td>\n C.2 Example of a test circuit
Figure C.2 \u2013 Example of a test circuit <\/td>\n<\/tr>\n\n 31<\/td>\n C.3 Example of a realized setup including schematics
Figure C.3 \u2013 Example for a realized test set up <\/td>\n<\/tr>\n\n 32<\/td>\n Annex D (informative) Test wave profiles <\/td>\n<\/tr>\n \n 33<\/td>\n Bibliography <\/td>\n<\/tr>\n<\/table>\n","protected":false},"excerpt":{"rendered":" \n\n
\n Published By<\/td>\n Publication Date<\/td>\n Number of Pages<\/td>\n<\/tr>\n \n BSI<\/b><\/a><\/td>\n 2014<\/td>\n 36<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n","protected":false},"featured_media":241961,"template":"","meta":{"rank_math_lock_modified_date":false,"ep_exclude_from_search":false},"product_cat":[626,2641],"product_tag":[],"class_list":{"0":"post-241959","1":"product","2":"type-product","3":"status-publish","4":"has-post-thumbnail","6":"product_cat-33-100-20","7":"product_cat-bsi","9":"first","10":"instock","11":"sold-individually","12":"shipping-taxable","13":"purchasable","14":"product-type-simple"},"_links":{"self":[{"href":"https:\/\/pdfstandards.shop\/wp-json\/wp\/v2\/product\/241959","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/pdfstandards.shop\/wp-json\/wp\/v2\/product"}],"about":[{"href":"https:\/\/pdfstandards.shop\/wp-json\/wp\/v2\/types\/product"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/pdfstandards.shop\/wp-json\/wp\/v2\/media\/241961"}],"wp:attachment":[{"href":"https:\/\/pdfstandards.shop\/wp-json\/wp\/v2\/media?parent=241959"}],"wp:term":[{"taxonomy":"product_cat","embeddable":true,"href":"https:\/\/pdfstandards.shop\/wp-json\/wp\/v2\/product_cat?post=241959"},{"taxonomy":"product_tag","embeddable":true,"href":"https:\/\/pdfstandards.shop\/wp-json\/wp\/v2\/product_tag?post=241959"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}