{"id":247296,"date":"2024-10-19T16:16:30","date_gmt":"2024-10-19T16:16:30","guid":{"rendered":"https:\/\/pdfstandards.shop\/product\/uncategorized\/bs-en-61753-121-32010\/"},"modified":"2024-10-25T11:22:54","modified_gmt":"2024-10-25T11:22:54","slug":"bs-en-61753-121-32010","status":"publish","type":"product","link":"https:\/\/pdfstandards.shop\/product\/publishers\/bsi\/bs-en-61753-121-32010\/","title":{"rendered":"BS EN 61753-121-3:2010"},"content":{"rendered":"
IEC 61753-121-3:2010 specifies the test requirements for finished cable assemblies for use as patchcords, work area cords and equipment cords for applications in a uncontrolled (U) environment according to IEC 61753-1, where the connectors already comply with the Category U requirements of IEC 61753-1. The assemblies consist of simplex or duplex fibre optic cable terminated at each end of the cable with non-angled (PC) or angled (APC) polished single-mode fibre optic connectors with cylindrical ferrules. The wavelength of operation is between 1 260 nm and 1 625 nm.<\/p>\n
PDF Pages<\/th>\n | PDF Title<\/th>\n<\/tr>\n | ||||||
---|---|---|---|---|---|---|---|
8<\/td>\n | CONTENTS <\/td>\n<\/tr>\n | ||||||
10<\/td>\n | 1 Scope 2 Normative references <\/td>\n<\/tr>\n | ||||||
12<\/td>\n | 3 Terms and definitions 4 Description 4.1 General <\/td>\n<\/tr>\n | ||||||
13<\/td>\n | 4.2 Optical fibres 4.3 Cable design and construction 4.4 Optical connectors 4.5 Cable bend radius 4.6 Identification 5 Tests 5.1 General 5.2 Measuring wavelengths Tables Table 1 \u2013 Wavelengths for attenuation and return loss measurements <\/td>\n<\/tr>\n | ||||||
14<\/td>\n | 5.3 Test specimen 6 Test procedure 6.1 General 6.2 Visual examination 6.3 Fibre optic connector end face Table 2 \u2013 Visual examination requirements <\/td>\n<\/tr>\n | ||||||
15<\/td>\n | 6.4 Optical performance requirements Table 3 \u2013 End face requirements <\/td>\n<\/tr>\n | ||||||
16<\/td>\n | Table 4 \u2013 Optical performance requirements <\/td>\n<\/tr>\n | ||||||
17<\/td>\n | 6.5 Climatic performance requirements Table 5 \u2013 Climatic performance requirements <\/td>\n<\/tr>\n | ||||||
18<\/td>\n | 6.6 Mechanical performance requirements Table 6 \u2013 Mechanical performance requirements <\/td>\n<\/tr>\n | ||||||
20<\/td>\n | 7 Test report <\/td>\n<\/tr>\n | ||||||
21<\/td>\n | Annex A (normative) Sample size and product sourcing requirements Table A.1 \u2013 Sample size requirements <\/td>\n<\/tr>\n | ||||||
22<\/td>\n | Annex B (normative) Visual examination of outer cable sheath movement Figures Figure B.1 \u2013 Initial marking of the cable sheath Figure B.2 \u2013 Final visual examination <\/td>\n<\/tr>\n | ||||||
23<\/td>\n | Annex C (normative) Change of temperature Figure C.1 \u2013 Change of temperature test configuration <\/td>\n<\/tr>\n | ||||||
24<\/td>\n | Annex D (normative) Static side load Figure D.1 \u2013 Test apparatus for transmission with applied side load <\/td>\n<\/tr>\n | ||||||
25<\/td>\n | Annex E (normative) Flexing strain relief of fibre optic devices Figure E.1 \u2013 Flexing test apparatus <\/td>\n<\/tr>\n | ||||||
26<\/td>\n | Bibliography <\/td>\n<\/tr>\n<\/table>\n","protected":false},"excerpt":{"rendered":" Fibre optic interconnecting devices and passive components. Performance standard – Simplex and duplex cords with single-mode fibre and cylindrical ferrule connectors for category U. Uncontrolled environment<\/b><\/p>\n |