{"id":250520,"date":"2024-10-19T16:31:37","date_gmt":"2024-10-19T16:31:37","guid":{"rendered":"https:\/\/pdfstandards.shop\/product\/uncategorized\/bs-en-iec-60317-0-22020\/"},"modified":"2024-10-25T11:45:22","modified_gmt":"2024-10-25T11:45:22","slug":"bs-en-iec-60317-0-22020","status":"publish","type":"product","link":"https:\/\/pdfstandards.shop\/product\/publishers\/bsi\/bs-en-iec-60317-0-22020\/","title":{"rendered":"BS EN IEC 60317-0-2:2020"},"content":{"rendered":"

IEC 60317-0-2:2020 is available as IEC 60317-0-2:2020 RLV<\/span> which contains the International Standard and its Redline version, showing all changes of the technical content compared to the previous edition.IEC 60317-0-2:2020 specifies the general requirements of enamelled rectangular copper winding wires. The range of nominal conductor dimensions is given in 4.1 and the relevant specification sheet. This fourth edition cancels and replaces the third edition published in 2013. This edition constitutes a technical revision. This edition includes the following significant technical changes with respect to the previous edition: – revision to Clause 2 to add new normative references for specifications for copper rods; – revision to 3.1 to add a new definition for the term \u201c bonding layer\u201d; – revision to 3.2.1 to the conditions specified for tests to be carried out; – revision to 4.5 to add requirements for minimal, nomimal and maximal overall dimensions with a bonding layer; – revision to Clause 5 to reference specifications for rectangular and square copper rod; – revision to Clause 6 to take into account nominal proof strength; – revision to 8.2 to the adherence test requirement; – revision to Clause 18 to make reference to the relevant specification sheet.<\/p>\n

PDF Catalog<\/h4>\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n
PDF Pages<\/th>\nPDF Title<\/th>\n<\/tr>\n
2<\/td>\nundefined <\/td>\n<\/tr>\n
5<\/td>\nAnnex ZA(normative)Normative references to international publicationswith their corresponding European publications <\/td>\n<\/tr>\n
7<\/td>\nEnglish
CONTENTS <\/td>\n<\/tr>\n
9<\/td>\nFOREWORD <\/td>\n<\/tr>\n
11<\/td>\nINTRODUCTION <\/td>\n<\/tr>\n
12<\/td>\n1 Scope
2 Normative references
3 Terms, definitions, general notes and appearance
3.1 Terms and definitions <\/td>\n<\/tr>\n
14<\/td>\n3.2 General notes
3.2.1 Methods of test
3.2.2 Winding wire
3.3 Appearance
4 Dimensions
4.1 Conductor dimensions <\/td>\n<\/tr>\n
15<\/td>\n4.2 Tolerance on conductor dimensions
4.3 Rounding of corners
Tables
Table 1 \u2013 Conductor tolerances <\/td>\n<\/tr>\n
16<\/td>\nTable 2 \u2013 Nominal cross-sectional areas of preferred sizes <\/td>\n<\/tr>\n
17<\/td>\n4.4 Increase in dimensions due to the insulation and the bonding layer
4.4.1 Enamelled wires without a bonding layer
4.4.2 Enamelled wires with a bonding layer
4.5 Overall dimensions
4.5.1 Nominal overall dimensions
Table 3 \u2013 Corner radii
Table 4 \u2013 Increases in dimensions <\/td>\n<\/tr>\n
18<\/td>\n4.5.2 Minimum overall dimensions
4.5.3 Maximum overall dimensions
5 Electrical resistance
6 Elongation
Table 5 \u2013 Percentage elongation after fracture <\/td>\n<\/tr>\n
19<\/td>\n7 Springiness (applicable to nominal proof strength \u2264 80 N\u00b7mm\u22122)
8 Flexibility and adherence
8.1 Mandrel winding test
8.2 Adherence test
9 Heat shock
Table 6 \u2013 Proof strength and resistivity
Table 7 \u2013 Mandrel winding <\/td>\n<\/tr>\n
20<\/td>\n10 Cut-through
11 Resistance to abrasion
12 Resistance to solvents
13 Breakdown voltage
14 Continuity of insulation
15 Temperature index
Table 8 \u2013 Breakdown voltage <\/td>\n<\/tr>\n
21<\/td>\n16 Resistance to refrigerants
17 Solderability
18 Heat or solvent bonding
19 Dielectric dissipation factor
20 Resistance to transformer oil
21 Loss of mass
23 Pin hole test
30 Packaging <\/td>\n<\/tr>\n
23<\/td>\nAnnex A (informative) Nominal cross-sectional areas for preferred and intermediate sizes
Table A.1 \u2013 Nominal cross-sectional areas <\/td>\n<\/tr>\n
32<\/td>\nBibliography <\/td>\n<\/tr>\n<\/table>\n","protected":false},"excerpt":{"rendered":"

Specifications for particular types of winding wires – General requirements. Enamelled rectangular copper wire<\/b><\/p>\n\n\n\n\n
Published By<\/td>\nPublication Date<\/td>\nNumber of Pages<\/td>\n<\/tr>\n
BSI<\/b><\/a><\/td>\n2020<\/td>\n34<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n","protected":false},"featured_media":250523,"template":"","meta":{"rank_math_lock_modified_date":false,"ep_exclude_from_search":false},"product_cat":[492,2641],"product_tag":[],"class_list":{"0":"post-250520","1":"product","2":"type-product","3":"status-publish","4":"has-post-thumbnail","6":"product_cat-29-060-10","7":"product_cat-bsi","9":"first","10":"instock","11":"sold-individually","12":"shipping-taxable","13":"purchasable","14":"product-type-simple"},"_links":{"self":[{"href":"https:\/\/pdfstandards.shop\/wp-json\/wp\/v2\/product\/250520","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/pdfstandards.shop\/wp-json\/wp\/v2\/product"}],"about":[{"href":"https:\/\/pdfstandards.shop\/wp-json\/wp\/v2\/types\/product"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/pdfstandards.shop\/wp-json\/wp\/v2\/media\/250523"}],"wp:attachment":[{"href":"https:\/\/pdfstandards.shop\/wp-json\/wp\/v2\/media?parent=250520"}],"wp:term":[{"taxonomy":"product_cat","embeddable":true,"href":"https:\/\/pdfstandards.shop\/wp-json\/wp\/v2\/product_cat?post=250520"},{"taxonomy":"product_tag","embeddable":true,"href":"https:\/\/pdfstandards.shop\/wp-json\/wp\/v2\/product_tag?post=250520"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}