{"id":252313,"date":"2024-10-19T16:39:20","date_gmt":"2024-10-19T16:39:20","guid":{"rendered":"https:\/\/pdfstandards.shop\/product\/uncategorized\/bs-en-61800-22015\/"},"modified":"2024-10-25T11:58:23","modified_gmt":"2024-10-25T11:58:23","slug":"bs-en-61800-22015","status":"publish","type":"product","link":"https:\/\/pdfstandards.shop\/product\/publishers\/bsi\/bs-en-61800-22015\/","title":{"rendered":"BS EN 61800-2:2015"},"content":{"rendered":"
This part of IEC 61800<\/span> <\/span> applies to adjustable speed electric a.c. power drive systems, which include semiconductor power conversion and the means for their control, protection, monitoring, measurement and the a.c. motor<\/i>s.<\/p>\n It applies to adjustable speed electric power drive systems intended to feed a.c. motors<\/i> from a BDM<\/i> connected to line-to-line voltages up to and including 1 kV a.c. 50 Hz or 60 Hz and\/or voltages up to and including 1,5 kV d.c. input side.<\/p>\n Adjustable speed electric a.c. power drive systems intended to feed a.c. motors, and with rated converter<\/i> input voltages above 1 000 V a.c. are covered by IEC 61800\u20114<\/span> <\/span>.<\/p>\n<\/div>\n Adjustable speed electric d.c. power drive systems intended to feed d.c. motors<\/i> are covered by IEC 61800\u20111<\/span> <\/span>.<\/p>\n<\/div>\n For adjustable speed electric a.c. power drive systems having series-connected electronic power converter<\/i> sections, the line-to-line voltage is the sum of the series connected input voltages.<\/p>\n<\/div>\n Traction applications and electric vehicles are excluded from the scope of this standard.<\/p>\n This part of IEC 61800<\/span> <\/span> is intended to define the following aspects of an a.c. power drive system ( PDS<\/i>):<\/p>\n principal parts of the PDS<\/i>;<\/p>\n<\/li>\n ratings and performance;<\/p>\n<\/li>\n specifications for the environment in which the PDS<\/i> is intended to be installed and operated;<\/p>\n<\/li>\n other specifications which might be applicable when specifying a complete PDS<\/i>.<\/p>\n<\/li>\n<\/ul>\n This standard provides minimum requirements, which may be used for the development of a specification between customer<\/i> and manufacturer<\/i>.<\/p>\n Compliance with this standard is possible only when each topic of this standard is individually specified by the customer<\/i> developing specifications or by product standard committees developing product standards.<\/p>\n For some aspects which are covered by specific PDS<\/i> product standards in the IEC 61800<\/span> Series<\/span>, this document provides a short introduction and reference to detailed requirements in these product standards.<\/p>\n This applies to the following aspects:<\/p>\n EMC which is covered in IEC 61800\u20113<\/span> <\/span>;<\/p>\n<\/li>\n electrical safety which is covered in IEC 61800\u20115\u20111<\/span> <\/span>;<\/p>\n<\/li>\n functional safety which is covered in IEC 61800\u20115\u20112<\/span> <\/span>;<\/p>\n<\/li>\n type of load duty which are covered by IEC TR 61800\u20116<\/span> <\/span>;<\/p>\n<\/li>\n communication profiles which are covered by IEC 61800\u20117<\/span> Series<\/span>;<\/p>\n<\/li>\n power interface<\/i> voltage specification which is covered by IEC TS 61800\u20118<\/span> <\/span>.<\/p>\n<\/li>\n<\/ul>\n Adjustable speed electrical power drive systems – General requirements. Rating specifications for low voltage adjustable speed a.c. power drive systems<\/b><\/p>\n\n
\n
PDF Catalog<\/h4>\n
\n
\n PDF Pages<\/th>\n PDF Title<\/th>\n<\/tr>\n \n 7<\/td>\n English
CONTENTS <\/td>\n<\/tr>\n\n 11<\/td>\n FOREWORD <\/td>\n<\/tr>\n \n 13<\/td>\n INTRODUCTION <\/td>\n<\/tr>\n \n 15<\/td>\n 1 Scope <\/td>\n<\/tr>\n \n 16<\/td>\n 2 Normative references <\/td>\n<\/tr>\n \n 17<\/td>\n 3 Terms and definitions <\/td>\n<\/tr>\n \n 18<\/td>\n Tables
Table 1 \u2013 List of terms
Table 2 \u2013 List of input ratings of BDM\/CDM\/PDS <\/td>\n<\/tr>\n\n 19<\/td>\n Table 3 \u2013 List of output ratings of BDM\/CDM\/PDS
Table 4 \u2013 List of motor speed and torque ratings <\/td>\n<\/tr>\n\n 20<\/td>\n Figures
Figure 1 \u2013 (BDM\/CDM\/PDS) manufacturer\/customer relationship <\/td>\n<\/tr>\n\n 30<\/td>\n Figure 2 \u2013 Example of a power drive system <\/td>\n<\/tr>\n \n 33<\/td>\n 4 Ratings and specifications for the act of installing, commissioning and operation
4.1 General
Figure 3 \u2013 Operating quadrants <\/td>\n<\/tr>\n\n 34<\/td>\n 4.2 BDM\/CDM\/PDS characteristics and topology
4.2.1 General
4.2.2 BDM\/CDM\/PDS characteristics <\/td>\n<\/tr>\n\n 35<\/td>\n 4.2.3 Basic topology for BDM\/CDM\/PDS\u2019s <\/td>\n<\/tr>\n \n 36<\/td>\n Figure 4 \u2013 Typical BDM\/CDM\/PDS
Figure 5 \u2013 Common d.c.link BDM\/CDM\/PDS <\/td>\n<\/tr>\n\n 37<\/td>\n Figure 6 \u2013 BDM\/CDM\/PDS with brake <\/td>\n<\/tr>\n \n 38<\/td>\n 4.3 Ratings
4.3.1 General
Figure 7 \u2013 BDM\/CDM\/PDS with AIC
Table 5 \u2013 Overview of input and output ratings of the BDM\/CDM\/PDS <\/td>\n<\/tr>\n\n 39<\/td>\n 4.3.2 Input ratings
Table 6 \u2013 Standard voltages as specified in IEC\u00a060038 <\/td>\n<\/tr>\n\n 40<\/td>\n 4.3.3 Output ratings
Figure 8 \u2013 Example of operating region of a PDS <\/td>\n<\/tr>\n\n 41<\/td>\n Figure 9 \u2013 Overload cycle example
Table 7 \u2013 Example of reduced maximum continuous load as a function of an overload <\/td>\n<\/tr>\n\n 42<\/td>\n 4.3.4 Operating quadrants
4.3.5 Ratings and properties of the control equipment
4.3.6 Special ratings related to BDM\/CDM\/PDS or motor <\/td>\n<\/tr>\n\n 43<\/td>\n 4.4 Performance
4.4.1 Operational <\/td>\n<\/tr>\n\n 44<\/td>\n Figure 10 \u2013 Deviation band
Table 8 \u2013 Maximum deviation bands (percent) <\/td>\n<\/tr>\n\n 47<\/td>\n Figure 11 \u2013 Time response following a step change of reference input no change in operating variables <\/td>\n<\/tr>\n \n 48<\/td>\n Figure 12 \u2013 Time response following a change in an operating variable \u2013 no reference change <\/td>\n<\/tr>\n \n 49<\/td>\n Figure 13 \u2013 Time response following a reference change at specified rate <\/td>\n<\/tr>\n \n 50<\/td>\n Figure 14 \u2013 Frequency response of the control \u2013 Reference value as stimulus <\/td>\n<\/tr>\n \n 52<\/td>\n 4.4.2 Fault supervision
4.4.3 Minimum status indication required
4.4.4 I\/O devices <\/td>\n<\/tr>\n\n 54<\/td>\n 4.5 Electrical safety
4.6 Functional safety <\/td>\n<\/tr>\n\n 55<\/td>\n 4.7 EMC
4.8 Eco design
4.8.1 General
4.8.2 Energy efficiency and losses
4.8.3 Environmental impact <\/td>\n<\/tr>\n\n 56<\/td>\n 4.9 Environmental condition for service, transport and storage
4.9.1 General
4.9.2 Operation <\/td>\n<\/tr>\n\n 57<\/td>\n Table 9 \u2013 Environmental service conditions <\/td>\n<\/tr>\n \n 58<\/td>\n Table 10 \u2013 Limit of temperature of the cooling medium for indoor equipment
Table 11 \u2013 Definitions of pollution degree <\/td>\n<\/tr>\n\n 59<\/td>\n Table 12 \u2013 Environmental vibration limits for fixed installation
Table 13 \u2013 Environmental shock limits for fixed installation <\/td>\n<\/tr>\n\n 61<\/td>\n 4.9.3 Storage and transport of equipment
Table 14 \u2013 Storage and transport limits <\/td>\n<\/tr>\n\n 62<\/td>\n 4.9.4 Environmental service tests (type test)
Table 15 \u2013 Transportation vibration limits
Table 16 \u2013 Transportation limits of free fall <\/td>\n<\/tr>\n\n 63<\/td>\n 4.10 Types of load duty profiles
4.11 Generic interface and use of profiles for PDS
Table 17 \u2013 Environmental service tests <\/td>\n<\/tr>\n\n 65<\/td>\n 4.12 Voltage on power interface
Figure 15 \u2013 Example of relationship of IEC\u00a061800-7 series to control system software and the BDM\/CDM\/PDS <\/td>\n<\/tr>\n\n 66<\/td>\n 4.13 Explosive environment
5 Test
5.1 General
5.2 Performance of tests
5.2.1 General conditions
5.2.2 Supply system earthing conditions <\/td>\n<\/tr>\n\n 67<\/td>\n 5.3 Standard tests for BDM\/CDM\/PDS
5.3.1 General
Table 18 \u2013 Test overview <\/td>\n<\/tr>\n\n 68<\/td>\n 5.3.2 Test for mass produced products
5.3.3 Test for one-off products <\/td>\n<\/tr>\n\n 69<\/td>\n 5.4 Test specifications
5.4.1 Visual inspections (type test, sample test and routine test)
5.4.2 Static performance and rating test <\/td>\n<\/tr>\n\n 70<\/td>\n Figure 16 \u2013 Measuring circuit of PDS <\/td>\n<\/tr>\n \n 75<\/td>\n 5.4.3 Electrical safety
5.4.4 Functional safety
5.4.5 EMC <\/td>\n<\/tr>\n\n 76<\/td>\n 5.4.6 Eco-design
5.4.7 Environmental condition tests <\/td>\n<\/tr>\n\n 77<\/td>\n Table 19 \u2013 Dry heat test (steady state) <\/td>\n<\/tr>\n \n 78<\/td>\n Table 20 \u2013 Damp heat test (steady state) <\/td>\n<\/tr>\n \n 79<\/td>\n Table 21 \u2013 Vibration test
Table 22 \u2013 Shock test <\/td>\n<\/tr>\n\n 80<\/td>\n Table 23 \u2013 Salt mist test
Table 24 \u2013 Dust test <\/td>\n<\/tr>\n\n 81<\/td>\n 5.4.8 Communication profiles
Table 25 \u2013 Sand test
Table 26 \u2013 Water test <\/td>\n<\/tr>\n\n 82<\/td>\n 5.4.9 Explosive atmosphere environment
6 Information and marking requirements
6.1 General <\/td>\n<\/tr>\n\n 83<\/td>\n 6.2 Marking on product
Table 27 \u2013 Information requirements <\/td>\n<\/tr>\n\n 84<\/td>\n 6.3 Information to be supplied with the PDS or BDM\/CDM
6.4 Information to be supplied or made available
6.5 Safety and warning labels
6.5.1 Warning labels
6.5.2 Additional safety considerations of a PDS <\/td>\n<\/tr>\n\n 86<\/td>\n Annex A (informative) Classification of PDS into low-voltage system and high-voltage system
A.1 General
A.2 Classification of PDS by voltage
Figure A.1 \u2013 Basic configuration of PDS <\/td>\n<\/tr>\n\n 87<\/td>\n A.3 Examples
A.3.1 PDS with an input transformer
A.3.2 PDS with an input transformer and an output transformer
Figure A.2 \u2013 An example of low-voltage PDS with an input transformer
Table\u00a0A.1 \u2013 Basic classification of PDS by voltage <\/td>\n<\/tr>\n\n 88<\/td>\n A.3.3 PDS with a step-up chopper
A.3.4 PDS with parallel-connected line-side converters
Figure A.3 \u2013 An example of low-voltage PDS with an input\/output transformer
Figure A.4 \u2013 An example of low-voltage PDS with a step-up chopper <\/td>\n<\/tr>\n\n 89<\/td>\n A.3.5 PDS with series-connected line-side converters
Figure A.5 \u2013 An example of low-voltage PDS with parallel-connected rectifiers
Figure A.6 \u2013 An example of high-voltage PDS with parallel-connected line-side converters <\/td>\n<\/tr>\n\n 90<\/td>\n A.3.6 PDS with star-connected inverters
Figure A.7 \u2013 An example of low-voltage PDS with series-connected rectifiers
Figure A.8 \u2013 An example of high-voltage PDS with series-connected rectifiers <\/td>\n<\/tr>\n\n 91<\/td>\n A.3.7 PDS with a multilevel inverter
Figure A.9 \u2013 An example of high-voltage PDS with star-connected inverters <\/td>\n<\/tr>\n\n 92<\/td>\n Figure A.10 \u2013 An example of high-voltage PDS with a multilevel inverter
Figure A.11 \u2013 An example of a power module <\/td>\n<\/tr>\n\n 93<\/td>\n Annex B (informative) Determination of the input current of BDM\/CDM\/PDS
Figure B.1 \u2013 Example of distortion effect of the input current affected by a three-phase converter with capacitive load <\/td>\n<\/tr>\n\n 95<\/td>\n Bibliography <\/td>\n<\/tr>\n<\/table>\n","protected":false},"excerpt":{"rendered":" \n\n
\n Published By<\/td>\n Publication Date<\/td>\n Number of Pages<\/td>\n<\/tr>\n \n BSI<\/b><\/a><\/td>\n 2015<\/td>\n 98<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n","protected":false},"featured_media":252317,"template":"","meta":{"rank_math_lock_modified_date":false,"ep_exclude_from_search":false},"product_cat":[2641],"product_tag":[],"class_list":{"0":"post-252313","1":"product","2":"type-product","3":"status-publish","4":"has-post-thumbnail","6":"product_cat-bsi","8":"first","9":"instock","10":"sold-individually","11":"shipping-taxable","12":"purchasable","13":"product-type-simple"},"_links":{"self":[{"href":"https:\/\/pdfstandards.shop\/wp-json\/wp\/v2\/product\/252313","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/pdfstandards.shop\/wp-json\/wp\/v2\/product"}],"about":[{"href":"https:\/\/pdfstandards.shop\/wp-json\/wp\/v2\/types\/product"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/pdfstandards.shop\/wp-json\/wp\/v2\/media\/252317"}],"wp:attachment":[{"href":"https:\/\/pdfstandards.shop\/wp-json\/wp\/v2\/media?parent=252313"}],"wp:term":[{"taxonomy":"product_cat","embeddable":true,"href":"https:\/\/pdfstandards.shop\/wp-json\/wp\/v2\/product_cat?post=252313"},{"taxonomy":"product_tag","embeddable":true,"href":"https:\/\/pdfstandards.shop\/wp-json\/wp\/v2\/product_tag?post=252313"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}