{"id":261334,"date":"2024-10-19T17:18:57","date_gmt":"2024-10-19T17:18:57","guid":{"rendered":"https:\/\/pdfstandards.shop\/product\/uncategorized\/bs-iso-19642-62019\/"},"modified":"2024-10-25T13:04:47","modified_gmt":"2024-10-25T13:04:47","slug":"bs-iso-19642-62019","status":"publish","type":"product","link":"https:\/\/pdfstandards.shop\/product\/publishers\/bsi\/bs-iso-19642-62019\/","title":{"rendered":"BS ISO 19642-6:2019"},"content":{"rendered":"
This document specifies the dimensions and requirements for single core cables intended for use in general purpose road vehicle applications where the nominal system voltage is 600 V a.c. or 900 V d.c. and 1 000 V a.c. or 1 500 V d.c. It also applies to the individual conductor cores used in multi core cables.<\/p>\n
This document specifies requirements for aluminium conductor cables.<\/p>\n
PDF Pages<\/th>\n | PDF Title<\/th>\n<\/tr>\n | ||||||
---|---|---|---|---|---|---|---|
2<\/td>\n | National foreword <\/td>\n<\/tr>\n | ||||||
7<\/td>\n | Foreword <\/td>\n<\/tr>\n | ||||||
8<\/td>\n | Introduction <\/td>\n<\/tr>\n | ||||||
9<\/td>\n | 1 Scope 2 Normative references 3 Terms and definitions <\/td>\n<\/tr>\n | ||||||
10<\/td>\n | 4 Specifications 4.1 General test conditions 4.2 Safety concerns 4.3 Voltage ratings 4.4 Temperature classes 4.5 Conductor material <\/td>\n<\/tr>\n | ||||||
11<\/td>\n | 4.6 Conductors 4.7 Insulation thickness <\/td>\n<\/tr>\n | ||||||
12<\/td>\n | 4.8 Cable outside diameter 4.9 Representative conductor sizes for testing 4.10 Reference and requirements for the tests according to ISO 19642\u20112 <\/td>\n<\/tr>\n | ||||||
13<\/td>\n | 5 Requirements 5.1 General <\/td>\n<\/tr>\n | ||||||
14<\/td>\n | 5.2 Dimensional tests 5.2.1 Cable outside diameter 5.2.2 Insulation thickness 5.2.3 Conductor diameter 5.2.4 Cross sectional area 5.2.5 In-process cable outside diameter 5.3 Electrical tests 5.3.1 Conductor resistance 5.3.2 Determination of temperature coefficients 5.3.3 Withstand voltage 5.3.4 Withstand voltage after environmental testing <\/td>\n<\/tr>\n | ||||||
15<\/td>\n | 5.3.5 Insulation faults 5.3.6 Insulation volume resistivity 5.4 Mechanical tests 5.4.1 Strip force 5.4.2 Abrasion <\/td>\n<\/tr>\n | ||||||
16<\/td>\n | 5.4.3 Breaking force of the finished cable 5.4.4 Cyclic bending 5.4.5 Flexibility <\/td>\n<\/tr>\n | ||||||
17<\/td>\n | 5.5 Environmental tests 5.5.1 Test specimen preparation and winding tests 5.5.2 Long term heat ageing, 3 000 h at temperature class rating 5.5.3 Short term heat ageing, 240 h at temperature class rating +25 \u00b0C 5.5.4 Thermal overload, 6 h at temperature class rating +50 \u00b0C 5.5.5 Pressure test at high temperature 5.5.6 Shrinkage by heat 5.5.7 Low temperature winding 5.5.8 Cold impact <\/td>\n<\/tr>\n | ||||||
18<\/td>\n | 5.5.9 Temperature and humidity cycling 5.5.10 Resistance to hot water 5.5.11 Resistance to liquid chemicals 5.5.12 Durability of cable marking 5.5.13 Stress cracking resistance 5.5.14 Resistance to ozone <\/td>\n<\/tr>\n | ||||||
19<\/td>\n | 5.5.15 Resistance to flame propagation <\/td>\n<\/tr>\n | ||||||
22<\/td>\n | Annex A (informative) ISO conductor sizes, number of strands and strand diameter <\/td>\n<\/tr>\n | ||||||
25<\/td>\n | Annex B (informative) Harness and cable colours <\/td>\n<\/tr>\n | ||||||
26<\/td>\n | Bibliography <\/td>\n<\/tr>\n<\/table>\n","protected":false},"excerpt":{"rendered":" Road vehicles. Automotive cables – Dimensions and requirements for 600 V a.c. or 900 V d.c. and 1 000 V a.c. or 1 500 V d.c. single core aluminium conductor cables<\/b><\/p>\n |