{"id":28629,"date":"2024-10-17T03:03:38","date_gmt":"2024-10-17T03:03:38","guid":{"rendered":"https:\/\/pdfstandards.shop\/product\/uncategorized\/astm-d4861\/"},"modified":"2024-10-24T14:05:12","modified_gmt":"2024-10-24T14:05:12","slug":"astm-d4861","status":"publish","type":"product","link":"https:\/\/pdfstandards.shop\/product\/publishers\/astm\/astm-d4861\/","title":{"rendered":"ASTM-D4861"},"content":{"rendered":"<\/p>\n

1.1 This practice covers the sampling of air for a variety of common pesticides and polychlorinated biphenyls (PCBs) and provides guidance on the selection of appropriate analytical measurement methods. Other compounds such as polychlorinated dibenzodioxins\/furans, polybrominated biphenyls, polybrominated diphenyl ethers, polycyclic aromatic hydrocarbons, and polychlorinated naphthalenes may be efficiently collected from air by this practice, but guidance on their analytical determination is not covered by this practice.<\/p>\n

1.2 A complete listing of pesticides and other semivolatile organic chemicals for which this practice has been tested is shown in Table 1.<\/p>\n

1.3 This practice is based on the collection of chemicals from air onto polyurethane foam (PUF) or a combination of PUF and granular sorbent.<\/p>\n

1.4 This practice is applicable to multicomponent atmospheres, 0.001 to 50- ?<\/span> g\/m 3<\/sup> concentrations, and 4 to 24-h sampling periods. The limit of detection will depend on the nature of the analyte and the length of the sampling period.<\/p>\n

1.5 The analytical method(s) recommended will depend on the specific chemical(s) sought, the concentration level, and the degree of specificity required.<\/p>\n

1.6 The values stated in SI units are to be regarded as standard. No other units of measurement are included in this standard.<\/p>\n

PDF Catalog<\/h4>\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n
PDF Pages<\/th>\nPDF Title<\/th>\n<\/tr>\n
1<\/td>\nScope
Referenced Documents <\/td>\n<\/tr>\n
2<\/td>\nTerminology
Summary of Practice
TABLE 1 <\/td>\n<\/tr>\n
3<\/td>\nSignificance and Use
Interferences
Apparatus
FIG. 1 <\/td>\n<\/tr>\n
4<\/td>\nSampling Procedure
FIG. 2 <\/td>\n<\/tr>\n
5<\/td>\nCalibration of Pump
FIG. 3 <\/td>\n<\/tr>\n
6<\/td>\nSample Extraction Procedure <\/td>\n<\/tr>\n
7<\/td>\nAnalysis Procedures <\/td>\n<\/tr>\n
8<\/td>\nCalculation <\/td>\n<\/tr>\n
9<\/td>\nSensitivity of the Procedure <\/td>\n<\/tr>\n
10<\/td>\nPrecision and Bias
Keywords
A1. DETERMINATION OF SAMPLING EFFICIENCY AND SPIKE RECOVERY
A1.1 <\/td>\n<\/tr>\n
11<\/td>\nFIG. A1.1 <\/td>\n<\/tr>\n
12<\/td>\nX1. SAMPLING AND RETENTION EFFICIENCY DATA FOR SEVERAL CLASSES OF PESTICIDES AND OTHER SEMIVOLATILE ORGANIC CHEMICALS
X1.1
TABLE X1.1
TABLE X1.2
TABLE X1.3 <\/td>\n<\/tr>\n
13<\/td>\nX2. SAMPLING AND RETENTION EFFICIENCY DATA FOR SEVERAL PESTICIDES OVER 24-H SAMPLING PERIODS
X2.1
TABLE X1.4 <\/td>\n<\/tr>\n
14<\/td>\nX3. STORAGE STABILITIES FOR VARIOUS PESTICIDES AND OTHER COMPOUNDS ON POLYURETHANE FOAM
X3.1
TABLE X2.1
TABLE X2.2 <\/td>\n<\/tr>\n
15<\/td>\nTABLE X3.1
TABLE X3.2 <\/td>\n<\/tr>\n
16<\/td>\nREFERENCES <\/td>\n<\/tr>\n<\/table>\n","protected":false},"excerpt":{"rendered":"

D4861-11 Standard Practice for Sampling and Selection of Analytical Techniques for Pesticides and Polychlorinated Biphenyls in Air<\/b><\/p>\n\n\n\n\n
Published By<\/td>\nPublication Date<\/td>\nNumber of Pages<\/td>\n<\/tr>\n
ASTM<\/b><\/a><\/td>\n2011<\/td>\n16<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n","protected":false},"featured_media":28630,"template":"","meta":{"rank_math_lock_modified_date":false,"ep_exclude_from_search":false},"product_cat":[204,2637],"product_tag":[],"class_list":{"0":"post-28629","1":"product","2":"type-product","3":"status-publish","4":"has-post-thumbnail","6":"product_cat-13-040-30","7":"product_cat-astm","9":"first","10":"instock","11":"sold-individually","12":"shipping-taxable","13":"purchasable","14":"product-type-simple"},"_links":{"self":[{"href":"https:\/\/pdfstandards.shop\/wp-json\/wp\/v2\/product\/28629","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/pdfstandards.shop\/wp-json\/wp\/v2\/product"}],"about":[{"href":"https:\/\/pdfstandards.shop\/wp-json\/wp\/v2\/types\/product"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/pdfstandards.shop\/wp-json\/wp\/v2\/media\/28630"}],"wp:attachment":[{"href":"https:\/\/pdfstandards.shop\/wp-json\/wp\/v2\/media?parent=28629"}],"wp:term":[{"taxonomy":"product_cat","embeddable":true,"href":"https:\/\/pdfstandards.shop\/wp-json\/wp\/v2\/product_cat?post=28629"},{"taxonomy":"product_tag","embeddable":true,"href":"https:\/\/pdfstandards.shop\/wp-json\/wp\/v2\/product_tag?post=28629"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}