{"id":28746,"date":"2024-10-17T03:05:24","date_gmt":"2024-10-17T03:05:24","guid":{"rendered":"https:\/\/pdfstandards.shop\/product\/uncategorized\/astm-e1623-3\/"},"modified":"2024-10-24T14:06:14","modified_gmt":"2024-10-24T14:06:14","slug":"astm-e1623-3","status":"publish","type":"product","link":"https:\/\/pdfstandards.shop\/product\/publishers\/astm\/astm-e1623-3\/","title":{"rendered":"ASTM-E1623"},"content":{"rendered":"<\/p>\n

1.1 This fire-test-response standard assesses the response of materials, products, and assemblies to controlled levels of radiant heat exposure with or without an external ignitor.<\/p>\n

1.2 The fire-test-response characteristics determined by this test method include the ignitability, heat release rates, mass loss rates, visible smoke development, and gas release of materials, products, and assemblies under well ventilated conditions.<\/p>\n

1.3 This test method is also suitable for determining many of the parameters or values needed as input for computer fire models. Examples of these values include effective heat of combustion, surface temperature, ignition temperature, and emissivity.<\/p>\n

1.4 This test method is also intended to provide information about other fire parameters such as thermal conductivity, specific heat, radiative and convective heat transfer coefficients, flame radiation factor, air entrainment rates, flame temperatures, minimum surface temperatures for upward and downward flame spread, heat of gasification, nondimensional heat of gasification (1)<\/span> and the ?<\/span> flame spread parameter (see Test Method E1321 ). While some studies have indicated that this test method is suitable for determining these fire parameters, insufficient testing and research have been done to justify inclusion of the corresponding testing and calculating procedures.<\/p>\n

PDF Catalog<\/h4>\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n
PDF Pages<\/th>\nPDF Title<\/th>\n<\/tr>\n
1<\/td>\nScope <\/td>\n<\/tr>\n
2<\/td>\nReferenced Documents
Terminology
Summary of Test Method <\/td>\n<\/tr>\n
3<\/td>\nSignificance and Use
Apparatus
FIG. 1 <\/td>\n<\/tr>\n
4<\/td>\nFIG. 2
FIG. 3 <\/td>\n<\/tr>\n
5<\/td>\nFIG. 4 <\/td>\n<\/tr>\n
6<\/td>\nFIG. 5
FIG. 6 <\/td>\n<\/tr>\n
7<\/td>\nHazards
Test Specimens
Calibration
FIG. 7 <\/td>\n<\/tr>\n
8<\/td>\nFIG. 8
FIG. 9 <\/td>\n<\/tr>\n
9<\/td>\nProcedure
Calculation <\/td>\n<\/tr>\n
10<\/td>\nReport
Precision and Bias <\/td>\n<\/tr>\n
11<\/td>\nTABLE 1
TABLE 2 <\/td>\n<\/tr>\n
13<\/td>\nKeywords
A1. DESIGN OF EXHAUST SYSTEM
A1.1 Design of Hood and Exhaust Duct <\/td>\n<\/tr>\n
14<\/td>\nA2. INSTRUMENTATION IN EXHAUST DUCT
A2.1 Flow Measurement
A2.2 Sampling Line
FIG. A1.1
FIG. A2.1
FIG. A2.2 <\/td>\n<\/tr>\n
15<\/td>\nA2.3 Combustion Gas Analysis
A2.4 Smoke Obscuration
FIG. A2.3
FIG. A2.4 <\/td>\n<\/tr>\n
16<\/td>\nA3. CONSIDERATIONS FOR HEAT RELEASE MEASUREMENTS
A3.1 Measurement of Rate of Heat Release by Oxygen Consumption
A3.2 Flow Measurements <\/td>\n<\/tr>\n
17<\/td>\nA3.3 Rate of Heat Release Measurement if Only Oxygen is Measured
A3.4 Rate of Heat Release Measurement if Oxygen and Carbon Dioxide are being Measured
A3.5 Rate of Heat Release Measurement if Oxygen, Carbon Dioxide, and Carbon Monoxide are being Measured
A3.6 Calculation of Heat Released by Igniting Fuel
A3.7 Conclusions <\/td>\n<\/tr>\n
18<\/td>\nA4. MEASUREMENT EQUATIONS
A4.1 Rate of Heat Release
A4.2 Total Heat Release Equations
A4.3 Smoke Measurement Equations <\/td>\n<\/tr>\n
19<\/td>\nA4.4 Gas Yield Measurement Calculations
A4.5 Symbols <\/td>\n<\/tr>\n
20<\/td>\nA5. MASS LOSS RATE AND EFFECTIVE HEAT OF COMBUSTION CALCULATIONS
A5.1 Mass Loss Rate and Effective Heat of Combustion
A6. Procedure for Calculating Analyzer Time Delay
A6.1
A6.2
A6.3
A6.4
A6.5
A6.6 <\/td>\n<\/tr>\n
21<\/td>\nA7. SAMPLE TEMPERATURE MEASUREMENTS
A7.1
A7.2
A7.3
A7.4
X1. COMMENTARY
X1.1 Introduction
X1.2 Factors Affecting Radiant Panel Assembly Performance
X1.3 Ignition Source for the ICAL <\/td>\n<\/tr>\n
22<\/td>\nREFERENCES <\/td>\n<\/tr>\n<\/table>\n","protected":false},"excerpt":{"rendered":"

E1623-11 Standard Test Method for Determination of Fire and Thermal Parameters of Materials, Products, and Systems Using an Intermediate Scale Calorimeter (ICAL)<\/b><\/p>\n\n\n\n\n
Published By<\/td>\nPublication Date<\/td>\nNumber of Pages<\/td>\n<\/tr>\n
ASTM<\/b><\/a><\/td>\n2011<\/td>\n22<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n","protected":false},"featured_media":28747,"template":"","meta":{"rank_math_lock_modified_date":false,"ep_exclude_from_search":false},"product_cat":[240,1253,2637],"product_tag":[],"class_list":{"0":"post-28746","1":"product","2":"type-product","3":"status-publish","4":"has-post-thumbnail","6":"product_cat-13-220-50","7":"product_cat-91-100-01","8":"product_cat-astm","10":"first","11":"instock","12":"sold-individually","13":"shipping-taxable","14":"purchasable","15":"product-type-simple"},"_links":{"self":[{"href":"https:\/\/pdfstandards.shop\/wp-json\/wp\/v2\/product\/28746","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/pdfstandards.shop\/wp-json\/wp\/v2\/product"}],"about":[{"href":"https:\/\/pdfstandards.shop\/wp-json\/wp\/v2\/types\/product"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/pdfstandards.shop\/wp-json\/wp\/v2\/media\/28747"}],"wp:attachment":[{"href":"https:\/\/pdfstandards.shop\/wp-json\/wp\/v2\/media?parent=28746"}],"wp:term":[{"taxonomy":"product_cat","embeddable":true,"href":"https:\/\/pdfstandards.shop\/wp-json\/wp\/v2\/product_cat?post=28746"},{"taxonomy":"product_tag","embeddable":true,"href":"https:\/\/pdfstandards.shop\/wp-json\/wp\/v2\/product_tag?post=28746"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}