{"id":313050,"date":"2024-10-19T21:32:33","date_gmt":"2024-10-19T21:32:33","guid":{"rendered":"https:\/\/pdfstandards.shop\/product\/uncategorized\/bs-en-iso-11298-32018\/"},"modified":"2024-10-25T19:35:47","modified_gmt":"2024-10-25T19:35:47","slug":"bs-en-iso-11298-32018","status":"publish","type":"product","link":"https:\/\/pdfstandards.shop\/product\/publishers\/bsi\/bs-en-iso-11298-32018\/","title":{"rendered":"BS EN ISO 11298-3:2018"},"content":{"rendered":"
This document, in conjunction with ISO 11298\u20111, specifies requirements and test methods for close-fit lining systems intended to be used for the renovation of water supply networks, which transport water intended for human consumption, including raw water intake pipelines.<\/p>\n
It applies to pipes and fittings, as manufactured, as well as to the installed lining system. It is applicable to polyethylene (PE) pipes of either solid wall single layer or co-extruded layer construction, which is reduced in the factory or on site to provide a close-fitting independent or interactive pressure pipe liner, as well as associated fittings and joints for the construction of the lining system. It is not applicable to PE coated pipes having a peelable, contiguous, thermoplastic additional layer on the outside of the pipe.<\/p>\n
It is applicable to PE pipes, fittings and assemblies intended to be used at an operating temperature of 20 \u00b0C as the reference temperature.<\/p>\n
\nNOTE For applications operating at constant temperatures greater than 20 \u00b0C and up to 40 \u00b0C, see ISO 4427\u20111:2007, Annex A.<\/p>\n<\/blockquote>\n
PDF Catalog<\/h4>\n
\n
\n PDF Pages<\/th>\n PDF Title<\/th>\n<\/tr>\n \n 2<\/td>\n National foreword <\/td>\n<\/tr>\n \n 4<\/td>\n European foreword <\/td>\n<\/tr>\n \n 7<\/td>\n Foreword <\/td>\n<\/tr>\n \n 8<\/td>\n Introduction <\/td>\n<\/tr>\n \n 11<\/td>\n 1 Scope
2 Normative references <\/td>\n<\/tr>\n\n 12<\/td>\n 3 Terms and definitions
3.1 General
3.2 Techniques <\/td>\n<\/tr>\n\n 13<\/td>\n 3.3 Characteristics
3.4 Materials
3.5 Product stages
3.6 Service conditions <\/td>\n<\/tr>\n\n 14<\/td>\n 3.7 Joints
4 Symbols and abbreviated terms
4.1 Symbols
4.2 Abbreviated terms <\/td>\n<\/tr>\n\n 15<\/td>\n 5 Pipes at the \u201cM\u201d stage
5.1 Materials
5.1.1 Virgin material
5.1.2 Reprocessable and recyclable material
5.2 General characteristics
5.2.1 Appearance
5.2.2 Colour
5.3 Material characteristics <\/td>\n<\/tr>\n\n 16<\/td>\n 5.4 Geometric characteristics
5.5 Mechanical characteristics
5.6 Physical characteristics
5.7 Jointing
5.8 Marking
5.9 Regional requirements for pipes <\/td>\n<\/tr>\n\n 17<\/td>\n 6 Fittings at the \u201cM\u201d stage
6.1 Requirements
6.2 Marking
6.3 Regional requirements for fittings
7 Ancillary components
8 Fitness for purpose of the installed lining system at the \u201cI\u201d stage
8.1 Materials
8.2 General characteristics
8.3 Material characteristics
8.4 Geometric characteristics <\/td>\n<\/tr>\n\n 18<\/td>\n 8.5 Mechanical characteristics <\/td>\n<\/tr>\n \n 19<\/td>\n 8.6 Physical characteristics
8.7 Additional characteristics
8.8 Sampling
8.9 Regional requirements for the installed lining system
9 Installation practice
9.1 Preparatory work
9.2 Storage, handling and transport of pipes and fittings <\/td>\n<\/tr>\n\n 20<\/td>\n 9.3 Equipment
9.3.1 Butt fusion and debeading equipment
9.3.2 Reduction equipment
9.3.3 Pipe skids\/rollers
9.3.4 Winching and rod-pulling equipment <\/td>\n<\/tr>\n\n 21<\/td>\n 9.3.5 Pipe entry guides
9.3.6 Reforming equipment
9.3.7 Electrofusion equipment
9.3.8 Inspection equipment
9.3.9 Lifting equipment <\/td>\n<\/tr>\n\n 22<\/td>\n 9.4 Installation
9.5 Process-related inspection and testing
9.6 Lining termination <\/td>\n<\/tr>\n\n 23<\/td>\n 9.7 Reconnection to the existing pipeline system
9.8 Final inspection and testing
9.9 Documentation <\/td>\n<\/tr>\n\n 24<\/td>\n Annex A (normative) Factory-folded heat-reverted polyethylene (PE) pipe \u2014 Determination of memory ability <\/td>\n<\/tr>\n \n 26<\/td>\n Bibliography <\/td>\n<\/tr>\n<\/table>\n","protected":false},"excerpt":{"rendered":" Plastics piping systems for renovation of underground water supply networks – Lining with close-fit pipes<\/b><\/p>\n
\n\n
\n Published By<\/td>\n Publication Date<\/td>\n Number of Pages<\/td>\n<\/tr>\n \n BSI<\/b><\/a><\/td>\n 2018<\/td>\n 28<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n","protected":false},"featured_media":313053,"template":"","meta":{"rank_math_lock_modified_date":false,"ep_exclude_from_search":false},"product_cat":[349,2641],"product_tag":[],"class_list":{"0":"post-313050","1":"product","2":"type-product","3":"status-publish","4":"has-post-thumbnail","6":"product_cat-23-040-20","7":"product_cat-bsi","9":"first","10":"instock","11":"sold-individually","12":"shipping-taxable","13":"purchasable","14":"product-type-simple"},"_links":{"self":[{"href":"https:\/\/pdfstandards.shop\/wp-json\/wp\/v2\/product\/313050","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/pdfstandards.shop\/wp-json\/wp\/v2\/product"}],"about":[{"href":"https:\/\/pdfstandards.shop\/wp-json\/wp\/v2\/types\/product"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/pdfstandards.shop\/wp-json\/wp\/v2\/media\/313053"}],"wp:attachment":[{"href":"https:\/\/pdfstandards.shop\/wp-json\/wp\/v2\/media?parent=313050"}],"wp:term":[{"taxonomy":"product_cat","embeddable":true,"href":"https:\/\/pdfstandards.shop\/wp-json\/wp\/v2\/product_cat?post=313050"},{"taxonomy":"product_tag","embeddable":true,"href":"https:\/\/pdfstandards.shop\/wp-json\/wp\/v2\/product_tag?post=313050"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}