{"id":362283,"date":"2024-10-20T01:39:54","date_gmt":"2024-10-20T01:39:54","guid":{"rendered":"https:\/\/pdfstandards.shop\/product\/uncategorized\/bs-iso-5660-12015a12019-tc\/"},"modified":"2024-10-26T02:36:35","modified_gmt":"2024-10-26T02:36:35","slug":"bs-iso-5660-12015a12019-tc","status":"publish","type":"product","link":"https:\/\/pdfstandards.shop\/product\/publishers\/bsi\/bs-iso-5660-12015a12019-tc\/","title":{"rendered":"BS ISO 5660-1:2015+A1:2019 – TC"},"content":{"rendered":"

PDF Catalog<\/h4>\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n
PDF Pages<\/th>\nPDF Title<\/th>\n<\/tr>\n
66<\/td>\nNational foreword <\/td>\n<\/tr>\n
71<\/td>\nForeword <\/td>\n<\/tr>\n
73<\/td>\n1 Scope
2 Normative references
3 Terms and definitions <\/td>\n<\/tr>\n
75<\/td>\n4 Symbols <\/td>\n<\/tr>\n
76<\/td>\n5 Principle <\/td>\n<\/tr>\n
77<\/td>\n6 Apparatus
6.1 General
6.2 Cone-shaped radiant electrical heater
6.3 Radiation shield
6.4 Irradiance control
6.5 Weighing device <\/td>\n<\/tr>\n
78<\/td>\n6.6 Specimen holder
6.7 Retainer frame
6.8 Exhaust gas system with flow measuring instrumentation
6.9 Gas sampling apparatus <\/td>\n<\/tr>\n
79<\/td>\n6.10 Ignition circuit
6.11 Ignition timer
6.12 Oxygen analyser
6.13 Heat flux meters
6.14 Calibration burner <\/td>\n<\/tr>\n
80<\/td>\n6.15 Data collection and analysis system
6.16 Optional side screens
6.17 Smoke obscuration measuring system
6.18 Smoke system thermocouple
6.19 Optical filters <\/td>\n<\/tr>\n
81<\/td>\n7 Suitability of a product for testing
7.1 Surface characteristics
7.2 Asymmetrical products
7.3 Materials of short burning time
7.4 Composite specimens
7.5 Dimensionally unstable materials <\/td>\n<\/tr>\n
82<\/td>\n7.6 Materials that require testing under compression
8 Specimen construction and preparation
8.1 Specimens <\/td>\n<\/tr>\n
83<\/td>\n8.2 Conditioning of specimens
8.3 Preparation
8.3.1 Specimen wrapping
8.3.2 Specimen preparation
8.3.3 Preparing specimens of materials that require testing under compression <\/td>\n<\/tr>\n
84<\/td>\n9 Test environment
10 Calibration
10.1 Preliminary calibrations
10.1.1 General
10.1.2 Irradiance control system response characteristics
10.1.3 Weighing device response time
10.1.4 Weighing device output drift
10.1.5 Oxygen analyser delay and response times <\/td>\n<\/tr>\n
85<\/td>\n10.1.6 Oxygen analyser output noise and drift
10.1.7 Effect of side screens <\/td>\n<\/tr>\n
86<\/td>\n10.2 Operating calibrations
10.2.1 General
10.2.2 Weighing device accuracy
10.2.3 Oxygen analyser <\/td>\n<\/tr>\n
87<\/td>\n10.2.4 Heat release rate calibration
10.2.5 Heater calibration
10.3 Smoke meter calibration
10.3.1 Calibration with neutral density filters
10.3.2 Calibration before test
10.4 Less frequent calibrations
10.4.1 Operating heat flux meter calibration
10.4.2 Linearity of heat release rate measurements <\/td>\n<\/tr>\n
88<\/td>\n10.4.3 Accuracy of calibration burner flow meter
11 Test procedure
11.1 General precautions
11.2 Initial preparation <\/td>\n<\/tr>\n
89<\/td>\n11.3 Procedure <\/td>\n<\/tr>\n
90<\/td>\n12 Calculations
12.1 General
12.2 Calibration constant for oxygen consumption analysis
12.3 Heat release rate <\/td>\n<\/tr>\n
91<\/td>\n12.4 Exhaust duct flow rate
12.5 Mass loss rate <\/td>\n<\/tr>\n
92<\/td>\n12.6 Smoke obscuration
13 Test report <\/td>\n<\/tr>\n
103<\/td>\nAnnex A(informative) Commentary and guidance notes for operators <\/td>\n<\/tr>\n
108<\/td>\nAnnex B(informative) Supplementary calculations \u2014 Normalization to the mass loss rate of the specific extinction area of specimen <\/td>\n<\/tr>\n
110<\/td>\nAnnex C(informative) Resolution, precision and bias <\/td>\n<\/tr>\n
116<\/td>\nAnnex D(informative) Mass loss rate and effective heat of combustion <\/td>\n<\/tr>\n
117<\/td>\nAnnex E(informative) Testing in the vertical orientation <\/td>\n<\/tr>\n
120<\/td>\nAnnex F(informative) Calibration of the working heat flux meter <\/td>\n<\/tr>\n
121<\/td>\nAnnex G(informative) Calculation of heat release with additional gas analysis <\/td>\n<\/tr>\n
125<\/td>\nAnnex H(informative) Calculation of Effective Critical Heat Flux for Ignition <\/td>\n<\/tr>\n
126<\/td>\nBibliography <\/td>\n<\/tr>\n<\/table>\n","protected":false},"excerpt":{"rendered":"

Reaction-to-fire tests. Heat release, smoke production and mass loss rate – Heat release rate (cone calorimeter method) and smoke production rate (dynamic measurement)<\/b><\/p>\n\n\n\n\n
Published By<\/td>\nPublication Date<\/td>\nNumber of Pages<\/td>\n<\/tr>\n
BSI<\/b><\/a><\/td>\n2020<\/td>\n128<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n","protected":false},"featured_media":362289,"template":"","meta":{"rank_math_lock_modified_date":false,"ep_exclude_from_search":false},"product_cat":[240,2641],"product_tag":[],"class_list":{"0":"post-362283","1":"product","2":"type-product","3":"status-publish","4":"has-post-thumbnail","6":"product_cat-13-220-50","7":"product_cat-bsi","9":"first","10":"instock","11":"sold-individually","12":"shipping-taxable","13":"purchasable","14":"product-type-simple"},"_links":{"self":[{"href":"https:\/\/pdfstandards.shop\/wp-json\/wp\/v2\/product\/362283","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/pdfstandards.shop\/wp-json\/wp\/v2\/product"}],"about":[{"href":"https:\/\/pdfstandards.shop\/wp-json\/wp\/v2\/types\/product"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/pdfstandards.shop\/wp-json\/wp\/v2\/media\/362289"}],"wp:attachment":[{"href":"https:\/\/pdfstandards.shop\/wp-json\/wp\/v2\/media?parent=362283"}],"wp:term":[{"taxonomy":"product_cat","embeddable":true,"href":"https:\/\/pdfstandards.shop\/wp-json\/wp\/v2\/product_cat?post=362283"},{"taxonomy":"product_tag","embeddable":true,"href":"https:\/\/pdfstandards.shop\/wp-json\/wp\/v2\/product_tag?post=362283"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}