{"id":396626,"date":"2024-10-20T04:25:35","date_gmt":"2024-10-20T04:25:35","guid":{"rendered":"https:\/\/pdfstandards.shop\/product\/uncategorized\/ieee-c37-20-2-1987\/"},"modified":"2024-10-26T08:13:03","modified_gmt":"2024-10-26T08:13:03","slug":"ieee-c37-20-2-1987","status":"publish","type":"product","link":"https:\/\/pdfstandards.shop\/product\/publishers\/ieee\/ieee-c37-20-2-1987\/","title":{"rendered":"IEEE C37.20.2-1987"},"content":{"rendered":"
New IEEE Standard – Superseded. This standard includes only the requirements for metal- clad and station-type cubicle switchgear. These requirements were previously a part of ANSI\/IEEE C37.20-1969 (R 1981), IEEE Standard for Switchgear Assemblies including Metal-Enclosed Bus (1974 Consolidated Edition). Other types of equipment previously included in ANSI \/ IEEE C37.20-1969 (R 1981) will now be incorporated in separate publications.<\/p>\n
PDF Pages<\/th>\n | PDF Title<\/th>\n<\/tr>\n | ||||||
---|---|---|---|---|---|---|---|
13<\/td>\n | Scope and References 1.1 Scope 1.2 References <\/td>\n<\/tr>\n | ||||||
14<\/td>\n | Definitions 2.1 Switchgear <\/td>\n<\/tr>\n | ||||||
16<\/td>\n | 2.2 Qualifying Terms 2.3 Common or Related Terms 2.4 Ambient Air Temperature 2.5 Design Tests 2.6 Production Tests 2.7 Conformance Tests 2.8 Field Tests <\/td>\n<\/tr>\n | ||||||
17<\/td>\n | 2.9 Circuit-Breaker Compartment 2.10 Auxiliary Compartment 2.11 Vertical Section Service Conditions Ratings 4.1 General 4.2 Voltage and Insulation Levels 4.3 Rated Frequency 4.4 Rated Current <\/td>\n<\/tr>\n | ||||||
18<\/td>\n | 4.5 Temperature Limitations Voltage and Insulation Levels-MC and SC Switchgear MC and SC Switchgear Continuous Current Ratings of Main Bus <\/td>\n<\/tr>\n | ||||||
19<\/td>\n | Switchgear Assemblies Switchgear Assemblies <\/td>\n<\/tr>\n | ||||||
20<\/td>\n | 4.6 Current Transformer Ratings 4.7 Current Transformer Accuracies Standard Accuracy Class Ratings-Current Transformers in MC Switchgear <\/td>\n<\/tr>\n | ||||||
21<\/td>\n | Tests 5.1 General 5.2 Design Tests 5.2.1 Dielectric Tests Standard Accuracy Class Ratings-Current Transformers in SC Switchgear <\/td>\n<\/tr>\n | ||||||
22<\/td>\n | 5.2.2 Rated Continuous Current Tests <\/td>\n<\/tr>\n | ||||||
23<\/td>\n | 5.2.3 Short-Time Current Withstand Test Copper Conductors for Use in Continuous Current Tests Copper Conductors for Use in Continuous Current Tests <\/td>\n<\/tr>\n | ||||||
24<\/td>\n | 5.2.4 Momentary Current Tests 5.2.5 Mechanical Endurance Tests and Connections <\/td>\n<\/tr>\n | ||||||
25<\/td>\n | 5.2.7 Flame-Resistance Tests for Applied Insulation Fig 1 Test Apparatus <\/td>\n<\/tr>\n | ||||||
26<\/td>\n | 5.2.8 Paint Qualification Test <\/td>\n<\/tr>\n | ||||||
27<\/td>\n | 5.2.9 Rain Test for Outdoor ME Switchgear 5.3 Production Tests 5.3.1 Dielectric Tests 5.3.2 Mechanical Operation Tests 5.3.3 Grounding of Instrument Transformer Cases Test 5.3.4 Electrical Operation and Control Wiring Tests <\/td>\n<\/tr>\n | ||||||
28<\/td>\n | 5.4 Conformance Tests 5.5 Field Dielectric Tests Construction 6.1 General Requirements 6.1.1 Buses and Primary Connections 6.1.2 Grounding <\/td>\n<\/tr>\n | ||||||
29<\/td>\n | 6.1.3 Control and Secondary Circuits and Devices <\/td>\n<\/tr>\n | ||||||
30<\/td>\n | 6.1.4 Miscellaneous <\/td>\n<\/tr>\n | ||||||
31<\/td>\n | 6.1.5 Materials Finishes and Color 6.1.6 Precautionary Labels 6.2 MC Switchgear 6.2.1 Barriers 6.2.2 Shutters 6.2.3 Insulating Materials for Covering Buses and Connections <\/td>\n<\/tr>\n | ||||||
32<\/td>\n | 6.2.4 Interlocks 6.2.5 Interchangeability of Removable Switching and Interrupting Devices 6.2.6 Primary Fuses and Voltage Transformers 6.2.7 Secondary Disconnect Devices 6.2.8 Control Wiring 6.2.9 Handling Device 6.2.10 Test Cabinet <\/td>\n<\/tr>\n | ||||||
33<\/td>\n | 6.2.11 Outdoor MC Switchgear Access and Ventilation 6.2.12 Outdoor MC Switchgear Access and Ventilation 6.3 SC Switchgear 6.3.2 Barriers 6.3.3 Buses and Connections 6.3.4 Interlocks 6.3.5 Control Wiring 6.3.6 Indoor Station-Type Cubicles Access and Ventilation 6.3.7 Outdoor Station-Type Cubicles Access and Ventilation <\/td>\n<\/tr>\n | ||||||
34<\/td>\n | 6.3.8 Secondary and Control Devices Application Guide for ME Switchgear 7.1 Unusual Service Conditions Ambient Air Temperature Above 40 “C Ambient Air Temperatures Below – 30 “C Application at Unusual Altitudes Modification of Equipment for Unusual Environment Altitude Correction Factors <\/td>\n<\/tr>\n | ||||||
36<\/td>\n | System Characteristics-Voltage and Frequency 7.3 Overvoltage Considerations-Insulation Levels Continuous Current Rating and Overload Capability <\/td>\n<\/tr>\n | ||||||
37<\/td>\n | Summary of Temperature Limitations Ratios of I, \/ I ) for Various Ambient Temperatures <\/td>\n<\/tr>\n | ||||||
38<\/td>\n | bility of Metal-Clad Switchgear Assemblies <\/td>\n<\/tr>\n | ||||||
39<\/td>\n | Typical Thermal Constants for MC Switchgear <\/td>\n<\/tr>\n | ||||||
40<\/td>\n | 7.5 Short-circuit Considerations Nuclear Power Plant Application Associated Devices Often Used in ME Switchgear Circuit Protective Equipment 8 Guide for Handling Storage and Installation 8.1 General 8.2 Handling <\/td>\n<\/tr>\n | ||||||
42<\/td>\n | 8.3 Preoperation Check 8.4 Removable Elements 8.5 Interlocks 8.6 Energization <\/td>\n<\/tr>\n | ||||||
43<\/td>\n | Guide for Enclosure Categories and Related Requirements <\/td>\n<\/tr>\n | ||||||
44<\/td>\n | Table A1 Requirements for Enclosure Categories Steel or Stainless Steel <\/td>\n<\/tr>\n | ||||||
45<\/td>\n | Table A3 Clearance to Ventilation Openings <\/td>\n<\/tr>\n<\/table>\n","protected":false},"excerpt":{"rendered":" IEEE\/ANSI Standard for Metal-Clad and Station-Type Cubicle Switchgear<\/b><\/p>\n |