{"id":407284,"date":"2024-10-20T05:25:32","date_gmt":"2024-10-20T05:25:32","guid":{"rendered":"https:\/\/pdfstandards.shop\/product\/uncategorized\/awc-fds-2021\/"},"modified":"2024-10-26T09:52:03","modified_gmt":"2024-10-26T09:52:03","slug":"awc-fds-2021","status":"publish","type":"product","link":"https:\/\/pdfstandards.shop\/product\/publishers\/awc\/awc-fds-2021\/","title":{"rendered":"AWC FDS 2021"},"content":{"rendered":"
Since 2001, the National Design Specification for Wood Construction has provided provisions for the structural design of unprotected wood members exposed to a standardized ASTM E119 fire exposure. The 2021 Fire Design Specification for Wood Construction (FDS) contains these provisions, and also provides calculation procedures to address the added fire resistance and thermal benefits of protection provided by additional wood cover, gypsum panel products, and insulation. The additional calculation provisions have been developed to provide standardized methods of calculating thermal separation and burn-through requirements as required in ASTM E119 and as provided in AWC\u2019s Technical Report 10: Calculating the Fire Resistance of Exposed and Protected Wood Members (TR10).<\/p>\n
PDF Pages<\/th>\n | PDF Title<\/th>\n<\/tr>\n | ||||||
---|---|---|---|---|---|---|---|
1<\/td>\n | Cover <\/td>\n<\/tr>\n | ||||||
3<\/td>\n | FOREWORD <\/td>\n<\/tr>\n | ||||||
10<\/td>\n | CHAPTER 1: GENERAL REQUIREMENTS FOR FIRE DESIGN 1.1 General 1.2 Terminology <\/td>\n<\/tr>\n | ||||||
15<\/td>\n | 1.3 Notation <\/td>\n<\/tr>\n | ||||||
18<\/td>\n | 1.5 Heavy Timber <\/td>\n<\/tr>\n | ||||||
21<\/td>\n | 1.6 Material Combustibility <\/td>\n<\/tr>\n | ||||||
22<\/td>\n | 1.7 Fire-Resistance-Rated Wood Members and Assemblies <\/td>\n<\/tr>\n | ||||||
26<\/td>\n | CHAPTER 2: IGNITION AND FLAMMABILITY 2.1 General 2.2 Ignition Resistance 2.3 Flame Spread Performance of Wood Products <\/td>\n<\/tr>\n | ||||||
27<\/td>\n | 2.4 Vertical and Lateral Flame Propagation <\/td>\n<\/tr>\n | ||||||
28<\/td>\n | 2.5 Firestopping, Fireblocking and Draftstopping <\/td>\n<\/tr>\n | ||||||
33<\/td>\n | CHAPTER 3: FIRE RESISTANCE 3.1 General <\/td>\n<\/tr>\n | ||||||
34<\/td>\n | 3.2 Calculation of Structural Fire Resistance of Exposed Wood Members <\/td>\n<\/tr>\n | ||||||
39<\/td>\n | 3.3 Protection of Structural Wood Members and Wood Assemblies <\/td>\n<\/tr>\n | ||||||
42<\/td>\n | 3.4 Calculation of Structural Fire Resistance Time of Protected Wood Members and Wood Assemblies 3.5 Calculation of Thermal Separation Time <\/td>\n<\/tr>\n | ||||||
43<\/td>\n | 3.6 Calculation of Burn-Through Time <\/td>\n<\/tr>\n | ||||||
44<\/td>\n | 3.7 Tested Fire-resistance-rated Wood Assemblies 3.8 Component Additive Method for Wood Assemblies <\/td>\n<\/tr>\n | ||||||
50<\/td>\n | 3.9 Design of Protected Wood Connections <\/td>\n<\/tr>\n | ||||||
52<\/td>\n | REFERENCES <\/td>\n<\/tr>\n | ||||||
55<\/td>\n | COMMENTARY <\/td>\n<\/tr>\n | ||||||
56<\/td>\n | FDS Commentary: Chapter C1 C1.1 General C1.2 Terminology <\/td>\n<\/tr>\n | ||||||
57<\/td>\n | C1.3 Notation <\/td>\n<\/tr>\n | ||||||
58<\/td>\n | C1.4 Materials Standards C1.5 Heavy Timber C1.6 Material Combustibility <\/td>\n<\/tr>\n | ||||||
59<\/td>\n | C1.7 Fire-Resistance-Rated Wood Members and Assemblies <\/td>\n<\/tr>\n | ||||||
63<\/td>\n | CHAPTER C2: IGNITION AND FLAMMABILITY C2.1 General C2.2 Ignition Resistance C2.3 Flame Spread Performance of Wood Products <\/td>\n<\/tr>\n | ||||||
65<\/td>\n | C2.4 Vertical and Lateral Flame Propagation C2.5 Firestopping, Fireblocking and Draftstopping <\/td>\n<\/tr>\n | ||||||
67<\/td>\n | CHAPTER C3: FIRE RESISTANCE C3.1 General <\/td>\n<\/tr>\n | ||||||
69<\/td>\n | C3.2 <\/td>\n<\/tr>\n | ||||||
74<\/td>\n | C3.3 Protection of Structural Wood Members and Wood Assemblies <\/td>\n<\/tr>\n | ||||||
78<\/td>\n | C3.4 Calculation of Structural Fire Resistance Time of Protected Wood Members and Wood Assemblies <\/td>\n<\/tr>\n | ||||||
79<\/td>\n | C3.5 Calculation of Thermal Separation Time <\/td>\n<\/tr>\n | ||||||
80<\/td>\n | C3.6 Calculation of Burn-Through Time C3.7 Tested Fire-resistance-rated Wood Assemblies <\/td>\n<\/tr>\n | ||||||
81<\/td>\n | C3.8 Component Additive Method for Wood Assemblies <\/td>\n<\/tr>\n | ||||||
83<\/td>\n | C3.9 Design of Protected Wood Connections <\/td>\n<\/tr>\n | ||||||
85<\/td>\n | COMMENTARY REFERENCES <\/td>\n<\/tr>\n<\/table>\n","protected":false},"excerpt":{"rendered":" Fire Design Specification for Wood Construction (FDS)<\/b><\/p>\n |