{"id":408846,"date":"2024-10-20T05:32:44","date_gmt":"2024-10-20T05:32:44","guid":{"rendered":"https:\/\/pdfstandards.shop\/product\/uncategorized\/bsi-22-30405472-dc-2022\/"},"modified":"2024-10-26T10:07:53","modified_gmt":"2024-10-26T10:07:53","slug":"bsi-22-30405472-dc-2022","status":"publish","type":"product","link":"https:\/\/pdfstandards.shop\/product\/publishers\/bsi\/bsi-22-30405472-dc-2022\/","title":{"rendered":"BSI 22\/30405472 DC 2022"},"content":{"rendered":"
PDF Pages<\/th>\n | PDF Title<\/th>\n<\/tr>\n | ||||||
---|---|---|---|---|---|---|---|
8<\/td>\n | Foreword <\/td>\n<\/tr>\n | ||||||
9<\/td>\n | Introduction <\/td>\n<\/tr>\n | ||||||
11<\/td>\n | 1 Scope 2 Normative references 3 Terms and definitions <\/td>\n<\/tr>\n | ||||||
13<\/td>\n | 4 General requirements 4.1 Compliance 4.2 Response threshold value of detectors using scattered or transmitted light 4.3 Individual alarm indication 4.4 Connection of ancillary devices 4.5 Monitoring of detachable detectors <\/td>\n<\/tr>\n | ||||||
14<\/td>\n | 4.6 Manufacturer’s adjustments 4.7 On-site adjustment of response behaviour 4.8 Protection against the ingress of foreign bodies 4.8.1 Closed detectors 4.8.2 Open detectors 4.9 Response to slowly developing fires <\/td>\n<\/tr>\n | ||||||
15<\/td>\n | 4.10 Requirements for software-controlled detectors 4.10.1 General 4.10.2 Software design 4.10.3 Storage of programs and data 5 Tests 5.1 General 5.1.1 Atmospheric conditions for tests 5.1.2 Operating conditions for tests <\/td>\n<\/tr>\n | ||||||
16<\/td>\n | 5.1.3 Mounting arrangements 5.1.4 Tolerances 5.1.5 Measurement of response threshold value <\/td>\n<\/tr>\n | ||||||
17<\/td>\n | 5.1.6 Provision for tests 5.1.7 Test schedule <\/td>\n<\/tr>\n | ||||||
18<\/td>\n | 5.1.8 Test report 5.2 Repeatability 5.2.1 Object of test 5.2.2 Test procedure 5.2.3 Requirements 5.3 Directional dependence 5.3.1 Object of test 5.3.2 Test procedure 5.3.3 Requirements <\/td>\n<\/tr>\n | ||||||
19<\/td>\n | 5.4 Reproducibility 5.4.1 Object of test 5.4.2 Test procedure 5.4.3 Requirements 5.5 Variation in supply parameters 5.5.1 Object of test 5.5.2 Test procedure 5.5.3 Requirements <\/td>\n<\/tr>\n | ||||||
20<\/td>\n | 5.6 Air movement 5.6.1 Object of test 5.6.2 Test procedure 5.6.3 Requirements 5.7 Dazzling 5.7.1 Object of test <\/td>\n<\/tr>\n | ||||||
21<\/td>\n | 5.7.2 Test procedure 5.7.3 Requirements 5.8 Additional tests for open detectors 5.8.1 Object of the test 5.8.2 Test procedure <\/td>\n<\/tr>\n | ||||||
22<\/td>\n | 5.9 Dry heat (operational) 5.9.1 Object of test 5.9.2 Test procedure 5.9.3 Requirements 5.10 Cold (operational) 5.10.1 Object of test <\/td>\n<\/tr>\n | ||||||
23<\/td>\n | 5.10.2 Test procedure 5.10.3 Requirements 5.11 Damp heat, steady state (operational) 5.11.1 Object of test 5.11.2 Test procedure <\/td>\n<\/tr>\n | ||||||
24<\/td>\n | 5.11.3 Requirements 5.12 Damp heat, steady state (endurance) 5.12.1 Object of test 5.12.2 Test procedure <\/td>\n<\/tr>\n | ||||||
25<\/td>\n | 5.12.3 Requirements 5.13 Sulfur dioxide (SO2) corrosion (endurance) 5.13.1 Object of test 5.13.2 Test procedure <\/td>\n<\/tr>\n | ||||||
26<\/td>\n | 5.13.3 Requirements 5.14 Shock (operational) 5.14.1 Object of test 5.14.2 Test procedure <\/td>\n<\/tr>\n | ||||||
27<\/td>\n | 5.14.3 Requirements 5.15 Impact (operational) 5.15.1 Object of test 5.15.2 Test procedure 5.15.3 Requirements <\/td>\n<\/tr>\n | ||||||
28<\/td>\n | 5.16 Vibration, sinusoidal, (operational) 5.16.1 Object of test 5.16.2 Test procedure <\/td>\n<\/tr>\n | ||||||
29<\/td>\n | 5.16.3 Requirements 5.17 Vibration, sinusoidal (endurance) 5.17.1 Object of test 5.17.2 Test procedure 5.17.3 Requirements <\/td>\n<\/tr>\n | ||||||
30<\/td>\n | 5.18 Electromagnetic compatibility (EMC) immunity tests (operational) 5.19 Fire sensitivity 5.19.1 Object of test 5.19.2 Test procedure <\/td>\n<\/tr>\n | ||||||
32<\/td>\n | 5.19.3 Requirements 6 Test report 7 Marking <\/td>\n<\/tr>\n | ||||||
33<\/td>\n | 8 Data 8.1 Hardware documentation 8.2 Software documentation <\/td>\n<\/tr>\n | ||||||
35<\/td>\n | Annex\u20acA (normative) Smoke tunnel for response threshold value measurements <\/td>\n<\/tr>\n | ||||||
36<\/td>\n | Annex\u20acB (normative) Test aerosol for response threshold value measurements <\/td>\n<\/tr>\n | ||||||
37<\/td>\n | Annex\u20acC (normative) Smoke-measuring instruments <\/td>\n<\/tr>\n | ||||||
41<\/td>\n | Annex\u20acD (normative) Apparatus for dazzling test <\/td>\n<\/tr>\n | ||||||
42<\/td>\n | Annex\u20acE (normative) Apparatus for impact test <\/td>\n<\/tr>\n | ||||||
44<\/td>\n | Annex\u20acF (normative) Fire test room <\/td>\n<\/tr>\n | ||||||
46<\/td>\n | Annex\u20acG (normative) Smouldering (pyrolysis) wood fire (TF2) <\/td>\n<\/tr>\n | ||||||
49<\/td>\n | Annex\u20acH (normative) Glowing smouldering cotton fire (TF3) <\/td>\n<\/tr>\n | ||||||
52<\/td>\n | Annex\u20acI (normative) Flaming plastics (polyurethane) fire (TF4) <\/td>\n<\/tr>\n | ||||||
55<\/td>\n | Annex\u20acJ (normative) Flaming liquid (n-heptane) fire (TF5) <\/td>\n<\/tr>\n | ||||||
58<\/td>\n | Annex\u20acK (informative) Information concerning the construction of the smoke tunnel <\/td>\n<\/tr>\n | ||||||
61<\/td>\n | Annex\u20acL (informative) Compensation for detector drift <\/td>\n<\/tr>\n | ||||||
65<\/td>\n | Annex\u20acM (informative) Information concerning the construction of the measuring ionization chamber <\/td>\n<\/tr>\n | ||||||
67<\/td>\n | Annex\u20acN (normative) Apparatus for open detector static object test <\/td>\n<\/tr>\n | ||||||
68<\/td>\n | Annex\u20acO (normative) Apparatus for testing the protection against the effect of moving objects <\/td>\n<\/tr>\n | ||||||
70<\/td>\n | Bibliography <\/td>\n<\/tr>\n<\/table>\n","protected":false},"excerpt":{"rendered":" Fire detection and alarm systems – Part 7. Point-type smoke detectors using scattered light, transmitted light or ionization<\/b><\/p>\n |