{"id":434321,"date":"2024-10-20T07:43:29","date_gmt":"2024-10-20T07:43:29","guid":{"rendered":"https:\/\/pdfstandards.shop\/product\/uncategorized\/bs-1363-12023\/"},"modified":"2024-10-26T14:39:36","modified_gmt":"2024-10-26T14:39:36","slug":"bs-1363-12023","status":"publish","type":"product","link":"https:\/\/pdfstandards.shop\/product\/publishers\/bsi\/bs-1363-12023\/","title":{"rendered":"BS 1363-1:2023"},"content":{"rendered":"
PDF Pages<\/th>\n | PDF Title<\/th>\n<\/tr>\n | ||||||
---|---|---|---|---|---|---|---|
6<\/td>\n | Foreword <\/td>\n<\/tr>\n | ||||||
9<\/td>\n | 1 Scope 2 Normative references <\/td>\n<\/tr>\n | ||||||
11<\/td>\n | 3 Terms and definitions <\/td>\n<\/tr>\n | ||||||
14<\/td>\n | 4 Conditions of use <\/td>\n<\/tr>\n | ||||||
15<\/td>\n | 5 General 6 General conditions for type testing <\/td>\n<\/tr>\n | ||||||
16<\/td>\n | Table 1 \u2014 Schedule of tests <\/td>\n<\/tr>\n | ||||||
17<\/td>\n | Figure 5 \u2014 Gauge for plug pins <\/td>\n<\/tr>\n | ||||||
18<\/td>\n | 7 Classification and rating 7.1 Classification 7.2 Rating Table 2 \u2014 Rated current and maximum fuse rating in normal use, and load for flexing and cable grip tests related to size of flexible cable <\/td>\n<\/tr>\n | ||||||
19<\/td>\n | 8 Marking and labelling <\/td>\n<\/tr>\n | ||||||
20<\/td>\n | 9 Clearances, creepage distances and solid insulation 9.1 Clearances <\/td>\n<\/tr>\n | ||||||
21<\/td>\n | Table 3 \u2014 Minimum clearances for basic insulation <\/td>\n<\/tr>\n | ||||||
22<\/td>\n | 9.2 Creepage distances <\/td>\n<\/tr>\n | ||||||
23<\/td>\n | Table 4 \u2014 Minimum creepage distances (mm) for basic insulation 9.3 Solid insulation Table 5 \u2014 Withstand voltages for insulation types 9.4 Requirements for printed wiring boards and equivalent construction <\/td>\n<\/tr>\n | ||||||
24<\/td>\n | 10 Accessibility of live parts <\/td>\n<\/tr>\n | ||||||
25<\/td>\n | Figure 2a) \u2014 Apparatus for mechanical strength test on resilient covers <\/td>\n<\/tr>\n | ||||||
26<\/td>\n | Figure 2b) \u2014 Hardwood block for Figure 2a) 11 Provision for earthing <\/td>\n<\/tr>\n | ||||||
27<\/td>\n | Table 6 \u2014 Torque values for screws and nuts 12 Terminals and terminations <\/td>\n<\/tr>\n | ||||||
30<\/td>\n | 13 Construction of plugs <\/td>\n<\/tr>\n | ||||||
31<\/td>\n | Figure 4a) \u2014 Dimensions and disposition of pins <\/td>\n<\/tr>\n | ||||||
33<\/td>\n | Figure 4b) \u2014 ISOD dimensions <\/td>\n<\/tr>\n | ||||||
36<\/td>\n | Figure 6 \u2014 Apparatus for testing plug cover fixing screws <\/td>\n<\/tr>\n | ||||||
37<\/td>\n | Figure 1 \u2014 Test pin <\/td>\n<\/tr>\n | ||||||
38<\/td>\n | Figure 32a) \u2014 Apparatus for tests on plug pins: A plug pin under test <\/td>\n<\/tr>\n | ||||||
39<\/td>\n | Figure 32b) \u2014 Apparatus for tests on plug pins: Details of anvils <\/td>\n<\/tr>\n | ||||||
41<\/td>\n | Figure 33 \u2014 Apparatus for torsion test on pins <\/td>\n<\/tr>\n | ||||||
42<\/td>\n | Figure 7 \u2014 Mounting plate <\/td>\n<\/tr>\n | ||||||
43<\/td>\n | Figure 8 \u2014 Plug pin deflection test apparatus for resilient plugs <\/td>\n<\/tr>\n | ||||||
45<\/td>\n | Figure 9 \u2014 Apparatus for abrasion test on insulating sleeves of plug pins <\/td>\n<\/tr>\n | ||||||
46<\/td>\n | Figure 10 \u2014 Apparatus for pressure test at high temperature <\/td>\n<\/tr>\n | ||||||
47<\/td>\n | Table 7 \u2014 Actuator test force <\/td>\n<\/tr>\n | ||||||
48<\/td>\n | 14 (Not used) 15 Resistance to ageing and to humidity 15.1 Resistance to ageing 15.2 Resistance to humidity <\/td>\n<\/tr>\n | ||||||
49<\/td>\n | 16 Insulation resistance and electric strength <\/td>\n<\/tr>\n | ||||||
50<\/td>\n | 17 Temperature rise <\/td>\n<\/tr>\n | ||||||
51<\/td>\n | Figure 17a) \u2014 Test apparatus for temperature rise test <\/td>\n<\/tr>\n | ||||||
53<\/td>\n | Figure 17b) \u2014 Dummy front plate for temperature rise <\/td>\n<\/tr>\n | ||||||
55<\/td>\n | Table 8 \u2014 Permitted temperature rises 18 Breaking capacity of switches incorporated in fused plugs 19 Normal operation of switches 20 Connection of flexible cables and cable anchorage <\/td>\n<\/tr>\n | ||||||
56<\/td>\n | Figure 18 \u2014 Apparatus for flexing test <\/td>\n<\/tr>\n | ||||||
59<\/td>\n | Table 9 \u2014 Connection of flexible cables 21 Mechanical strength Figure 19 \u2014 Solid link for test on fuse clips <\/td>\n<\/tr>\n | ||||||
60<\/td>\n | Figure 20 \u2014 Tumbling barrel <\/td>\n<\/tr>\n | ||||||
61<\/td>\n | 22 Screws, current-carrying parts and connections <\/td>\n<\/tr>\n | ||||||
62<\/td>\n | 23 Resistance to heat <\/td>\n<\/tr>\n | ||||||
63<\/td>\n | Figure 23 \u2014 Apparatus for pressure test <\/td>\n<\/tr>\n | ||||||
64<\/td>\n | 24 Resistance to abnormal heat and fire 24.1 General 24.2 Glow-wire test <\/td>\n<\/tr>\n | ||||||
65<\/td>\n | Table 10 \u2014 Application of glow-wire test 25 Resistance to excessive residual stresses and to rusting <\/td>\n<\/tr>\n | ||||||
66<\/td>\n | 26 Electrical and thermal stress of clamp type (screwless) terminals 27 Overload tests <\/td>\n<\/tr>\n | ||||||
67<\/td>\n | 28 Cyclic loading test 28.1 Requirement 28.2 Testing <\/td>\n<\/tr>\n | ||||||
68<\/td>\n | Annex A (normative)\u2002 Requirements for incorporated electronic components <\/td>\n<\/tr>\n | ||||||
70<\/td>\n | Annex B (informative)\u2002 Recommendations for products that incorporate BS 1363\u20111 plug pins Table B.1 \u2014 List of clauses <\/td>\n<\/tr>\n | ||||||
71<\/td>\n | Annex C (normative)\u2002 Pollution degree <\/td>\n<\/tr>\n | ||||||
72<\/td>\n | Annex D (normative)\u2002 Relation between rated impulse withstand voltage, rated voltage and Overvoltage Category Table D.1 \u2014 Rated impulse withstand voltage for plugs energized directly from the low voltage mains Annex E (normative)\u2002 Impulse voltage test <\/td>\n<\/tr>\n | ||||||
73<\/td>\n | Table E.1 \u2014 Test voltages for verifying clearances at sea level Annex F (normative)\u2002 Measurement of clearance and creepage distances Table F.1 \u2014 Minimum values of width X <\/td>\n<\/tr>\n | ||||||
74<\/td>\n | Figure F.1 \u2014 Example 1 Figure F.2 \u2014 Example 2 Figure F.3 \u2014 Example 3 <\/td>\n<\/tr>\n | ||||||
75<\/td>\n | Figure F.4 \u2014 Example 4 Figure F.5 \u2014 Example 5 Figure F.6 \u2014 Example 6 <\/td>\n<\/tr>\n | ||||||
76<\/td>\n | Figure F.7 \u2014 Example 7 Figure F.8 \u2014 Example 8 Figure F.9 \u2014 Example 9 <\/td>\n<\/tr>\n | ||||||
77<\/td>\n | Figure F.10 \u2014 Example 10 Figure F.11 \u2014 Example 11 Annex G (informative)\u2002 Dimensions for plug profiles <\/td>\n<\/tr>\n | ||||||
78<\/td>\n | Figure G.1 \u2014 Normal plug profile Figure G.2 \u2014 Compact plug profile <\/td>\n<\/tr>\n | ||||||
79<\/td>\n | Annex H (normative)\u2002 The construction and calibration of a calibrated link Figure 28 \u2014 Calibrated link <\/td>\n<\/tr>\n | ||||||
82<\/td>\n | Figure 29 \u2014 Calibration jig for calibrated link <\/td>\n<\/tr>\n | ||||||
83<\/td>\n | Annex I (normative)\u2002 Determination of the Comparative Tracking Index and Proof Tracking Index Annex J (informative)\u2002 Annex identification migration from 2016 edition to 2023 edition <\/td>\n<\/tr>\n | ||||||
84<\/td>\n | Table J.1 \u2014 BS 1363 annex identification migration from 2016 to 2023 <\/td>\n<\/tr>\n | ||||||