{"id":435795,"date":"2024-10-20T07:51:30","date_gmt":"2024-10-20T07:51:30","guid":{"rendered":"https:\/\/pdfstandards.shop\/product\/uncategorized\/bsi-23-30476453-dc-2023\/"},"modified":"2024-10-26T14:52:57","modified_gmt":"2024-10-26T14:52:57","slug":"bsi-23-30476453-dc-2023","status":"publish","type":"product","link":"https:\/\/pdfstandards.shop\/product\/publishers\/bsi\/bsi-23-30476453-dc-2023\/","title":{"rendered":"BSI 23\/30476453 DC 2023"},"content":{"rendered":"

PDF Catalog<\/h4>\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n
PDF Pages<\/th>\nPDF Title<\/th>\n<\/tr>\n
9<\/td>\n1 Scope <\/td>\n<\/tr>\n
10<\/td>\n2 Normative references <\/td>\n<\/tr>\n
11<\/td>\n3 Terms, definitions and abbreviations
3.1 Terms and definitions
3.1.1 System
3.1.2 Connection <\/td>\n<\/tr>\n
13<\/td>\n3.1.3 Electrical <\/td>\n<\/tr>\n
15<\/td>\n3.2 Abbreviations <\/td>\n<\/tr>\n
16<\/td>\n4 System overview
4.1 Introduction
4.1.1 General
4.1.2 Three-phase shore power supply <\/td>\n<\/tr>\n
17<\/td>\n4.1.3 Safety Extra Low Voltage (SELV) DC shore power supply
4.2 Protective devices
4.2.1 General
4.2.2 Shore side protective devices
4.2.3 Rolling stock protective devices <\/td>\n<\/tr>\n
18<\/td>\n4.2.4 Rail bonding options and PE
4.2.4.1 Shore side
4.2.4.2 Rolling stock side
4.3 Control and monitoring circuitry
4.3.1 Sequence of operation
4.3.1.1 Preparation
4.3.1.2 Connecting to shore supply <\/td>\n<\/tr>\n
19<\/td>\n4.3.1.3 Energized state
4.3.1.4 Fault occurrence
4.3.1.5 De-energizing and disconnecting
4.3.1.6 Feedback <\/td>\n<\/tr>\n
20<\/td>\n4.4 Connection diagrams 63\/125A <\/td>\n<\/tr>\n
22<\/td>\n4.5 Connection diagrams 600A
5 General requirements
5.1 Alternative implementations <\/td>\n<\/tr>\n
23<\/td>\n5.2 Shore supply system power ratings
5.2.1 Three-phase requirements
5.2.2 Control loop SELV system requirements
5.3 Interaction between rolling stock and shore supply
5.3.1 Shore supply IT floating (63A\/125A)
5.3.2 No connection between shore MEB (PE) and rolling stock PE (63A\/125A) <\/td>\n<\/tr>\n
24<\/td>\n5.3.3 Clockwise rotation field
5.3.4 Use of neutral (63A\/125A)
5.3.5 Use of neutral (600A) <\/td>\n<\/tr>\n
25<\/td>\n5.3.6 Prevent movement of the rolling stock
5.3.7 Rolling stock inrush current limitation
5.3.8 Exclusive train line supply modes
5.3.9 Shore supply activation when TCMS is unavailable (optional)
5.3.10 Flat Battery Start (optional)
5.3.11 Location of shore supply socket on Rolling Stock
5.4 Electrical safety
5.4.1 Basic safety requirements <\/td>\n<\/tr>\n
26<\/td>\n5.4.2 Temporary outage of power grid
5.4.3 Insulation safety
5.4.4 Touch safety <\/td>\n<\/tr>\n
27<\/td>\n5.4.5 Overload and short circuit protection
5.4.5.1 General
5.4.5.2 Shore overload and short circuit protection requirements
5.4.5.3 Rolling stock overload and short circuit protection requirements
5.4.6 Three-phase monitoring device <\/td>\n<\/tr>\n
28<\/td>\n5.4.7 Isolation contactor
5.4.8 Earth fault monitoring device
5.4.9 Emergency cut-off switch
5.4.10 Bonding of connector housings
5.4.10.1 63A\/125A system <\/td>\n<\/tr>\n
29<\/td>\n5.4.10.2 600A system
5.5 Requirements for the shore supply transformer
5.5.1 63A or 125A shore supply
5.5.1.1 General
5.5.1.2 Isolation voltage
5.5.1.3 Secondary voltage Us
5.5.1.4 Capacitive current <\/td>\n<\/tr>\n
30<\/td>\n5.6 Galvanic isolation
5.7 Electrical characteristics of the shore supply voltage
5.7.1 General
5.7.2 Frequency
5.7.3 Voltage requirements <\/td>\n<\/tr>\n
31<\/td>\n5.7.4 Distortion requirements
5.7.5 Current unbalance
5.8 Infrastructure of the shore supply
5.8.1 Socket system
5.8.1.1 General
5.8.1.2 A fixed socket and a shore supply cable with two free connectors
5.8.1.3 A fixed shore supply cable with one free connector
5.8.2 Stowage of connector or shore supply cables
5.8.3 Shore supply cables
6 Connector requirements
6.1 General
6.1.1 Voltage ratings <\/td>\n<\/tr>\n
32<\/td>\n6.1.2 Current rating main contacts
6.1.3 Current rating for the pilot and coding contacts
6.1.3.1 General
6.1.3.2 Connector layouts 63A\/125A connectors
6.1.3.3 600A connectors
6.1.3.4 Pilot contacts
6.1.3.5 Coding contacts <\/td>\n<\/tr>\n
33<\/td>\n6.1.4 Connector dimensions
6.1.5 Gender of the connectors
6.1.6 Accepted cables <\/td>\n<\/tr>\n
34<\/td>\n6.1.7 Contact design
6.1.7.1 Male contact
6.1.7.2 Female contact <\/td>\n<\/tr>\n
35<\/td>\n6.1.8 Contact resistance of wired contact pair by contact type
6.1.9 Wired contact voltage drop linked to the cable section
6.1.10 Environmental requirements
6.1.11 Single person operation <\/td>\n<\/tr>\n
36<\/td>\n6.2 Marking and identification
6.2.1 Identification
6.2.2 Marking
6.3 Scoop proof
6.4 Connector IP requirements
6.4.1 63A\/125A system
6.4.1.1 Fixed connector requirements
6.4.1.2 Cable connector requirements <\/td>\n<\/tr>\n
37<\/td>\n6.4.2 600A system
6.5 Terminations and connection methods
6.5.1 Crimped connections
6.5.2 Soldered connections
6.5.3 Tooling
6.6 Resistance to ageing
6.7 Mechanical lock
6.7.1 63A\/125A system
6.7.2 600A system <\/td>\n<\/tr>\n
38<\/td>\n6.8 Mechanical and electrical durability
6.9 Dielectric strength
6.10 Harness or assembly strain relief
6.11 Mechanical strength
6.11.1 Insert retention in the shell
6.11.2 Retention of the contacts within insert
6.11.3 Durability
6.11.4 Bending moment withstand
6.12 Vibration and shock
6.13 Insulation coordination
6.14 Temperature classes <\/td>\n<\/tr>\n
39<\/td>\n6.15 Temperature rise
6.16 Protection against corrosion
6.17 Fire behaviour of materials and components
6.18 Resistance to chemically active substances and to contaminating fluids
6.19 Resistance to ozone
6.20 Resistance to UV radiation
6.21 Connector material
6.22 Protective cover <\/td>\n<\/tr>\n
40<\/td>\n7 Tests
7.1 Introduction
7.1.1 General
7.1.2 Preconditioning and preparation
7.1.3 Test conditions <\/td>\n<\/tr>\n
41<\/td>\n7.2 Test schedule
7.2.1 Test conditions for Group A \u2014 Mechanical
7.2.1.1 General
7.2.1.2 Test phase A1 <\/td>\n<\/tr>\n
42<\/td>\n7.2.1.3 Test phase A6
7.2.1.4 Test phase A7
7.2.2 Test conditions for Group B \u2013 Service life
7.2.2.1 Test phase B1
7.2.2.2 Test phase B2\u00a0\u2014 Requirement for (visual) examination <\/td>\n<\/tr>\n
43<\/td>\n7.2.3 Test conditions for Group C \u2014 Thermal
7.2.4 Test conditions for Group D – Climatic
7.2.4.1 Test phase D2
7.2.4.2 Test phase D3
7.2.4.3 Test phase D6 <\/td>\n<\/tr>\n
44<\/td>\n7.2.5 Test conditions for Group E \u2013 Degree of protection
7.2.5.1 Test phase E1
7.2.5.2 Test phase E2
7.2.6 Test conditions for Group F\u00a0\u2014 Vibration and shock <\/td>\n<\/tr>\n
45<\/td>\n7.2.7 Test conditions for Group G \u2014 Resistance to fluid
7.3 Tests on raw materials
7.4 Protection against electric shock
7.5 Temperature rise <\/td>\n<\/tr>\n
46<\/td>\n7.6 Mechanical operation
7.6.1 General
7.6.2 Test conditions
7.7 Measurement of contact resistance of wired contact pair
7.8 Drop test for free connector <\/td>\n<\/tr>\n
47<\/td>\n7.9 Measurement of clearances and creepage
7.10 Dielectric strength
7.11 Resistance between earthing conductor of the free connector and the shell of the fixed connector
7.12 Corrosion test
7.13 Contact retention <\/td>\n<\/tr>\n
48<\/td>\nAnnex\u00a0A (normative) 63A\/125A Connector design
A.1 Fixed connector male
A.1.1 Arrangement of contacts <\/td>\n<\/tr>\n
50<\/td>\nA.1.2 Locking mechanism <\/td>\n<\/tr>\n
51<\/td>\nA.1.3 Lid opening mechanism <\/td>\n<\/tr>\n
52<\/td>\nA.1.4 Dimensions of power pins <\/td>\n<\/tr>\n
54<\/td>\nA.1.5 Dimensions of pilot and coding pins <\/td>\n<\/tr>\n
56<\/td>\nA.2 Fixed connector female
A.2.1 Contact arrangements <\/td>\n<\/tr>\n
57<\/td>\nA.2.2 Power sockets <\/td>\n<\/tr>\n
59<\/td>\nA.2.3 Pilot and coding socket contacts <\/td>\n<\/tr>\n
60<\/td>\nA.2.4 Dimensions of protective cover <\/td>\n<\/tr>\n
61<\/td>\nA.3 Free connector female
A.3.1 General <\/td>\n<\/tr>\n
62<\/td>\nA.3.2 Arrangement of contacts and locking pin <\/td>\n<\/tr>\n
64<\/td>\nA.3.3 Dimensions of power socket contacts <\/td>\n<\/tr>\n
65<\/td>\nA.3.4 Dimensions of pilot and coding contacts <\/td>\n<\/tr>\n
66<\/td>\nA.4 Free connector male
A.4.1 Arrangement of contacts <\/td>\n<\/tr>\n
67<\/td>\nA.4.2 Dimensions of power pin contacts <\/td>\n<\/tr>\n
68<\/td>\nA.4.3 Dimensions of pilot and coding pin contacts <\/td>\n<\/tr>\n
69<\/td>\nAnnex\u00a0B (normative)600A connector design
B.1 Fixed connector female
B.1.1 General <\/td>\n<\/tr>\n
72<\/td>\nB.1.2 Arrangement of contacts <\/td>\n<\/tr>\n
73<\/td>\nB.1.3 Locking mechanism <\/td>\n<\/tr>\n
74<\/td>\nB.1.4 Dimensions of contacts
B.1.4.1 Dimensions of power contacts <\/td>\n<\/tr>\n
75<\/td>\nB.1.4.2 Pilot and coding contacts
B.2 Free connector male
B.2.1 General <\/td>\n<\/tr>\n
77<\/td>\nB.2.2 Dimensions for locking arrangement <\/td>\n<\/tr>\n
79<\/td>\nB.2.3 Dimensions of power contacts <\/td>\n<\/tr>\n
80<\/td>\nB.2.4 Dimensions of pilot and coding contacts <\/td>\n<\/tr>\n
82<\/td>\nAnnex\u00a0C (informative)Explanation about some protection features
C.1 General overview <\/td>\n<\/tr>\n
83<\/td>\nC.2 Overload and short circuit protection <\/td>\n<\/tr>\n
84<\/td>\nC.3 Protection against direct contact on shore supply side
C.4 Why a single secondary winding per shore supply connector? <\/td>\n<\/tr>\n
85<\/td>\nC.5 Selectivity with individual socket protection on Rolling Stock <\/td>\n<\/tr>\n
86<\/td>\nC.6 Inrush and leakage current <\/td>\n<\/tr>\n
88<\/td>\nAnnex\u00a0ZZ (informative)Relationship between this European Standard and the essential requirements of EU Directive (EU) 2016\/797 aimed to be covered <\/td>\n<\/tr>\n<\/table>\n","protected":false},"excerpt":{"rendered":"

BS EN 50546. Railway applications. Rolling Stock. Three-phase shore (external) supply system for rail vehicles and its connectors<\/b><\/p>\n\n\n\n\n
Published By<\/td>\nPublication Date<\/td>\nNumber of Pages<\/td>\n<\/tr>\n
BSI<\/b><\/a><\/td>\n2023<\/td>\n90<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n","protected":false},"featured_media":435802,"template":"","meta":{"rank_math_lock_modified_date":false,"ep_exclude_from_search":false},"product_cat":[775,2641],"product_tag":[],"class_list":{"0":"post-435795","1":"product","2":"type-product","3":"status-publish","4":"has-post-thumbnail","6":"product_cat-45-060-01","7":"product_cat-bsi","9":"first","10":"instock","11":"sold-individually","12":"shipping-taxable","13":"purchasable","14":"product-type-simple"},"_links":{"self":[{"href":"https:\/\/pdfstandards.shop\/wp-json\/wp\/v2\/product\/435795","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/pdfstandards.shop\/wp-json\/wp\/v2\/product"}],"about":[{"href":"https:\/\/pdfstandards.shop\/wp-json\/wp\/v2\/types\/product"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/pdfstandards.shop\/wp-json\/wp\/v2\/media\/435802"}],"wp:attachment":[{"href":"https:\/\/pdfstandards.shop\/wp-json\/wp\/v2\/media?parent=435795"}],"wp:term":[{"taxonomy":"product_cat","embeddable":true,"href":"https:\/\/pdfstandards.shop\/wp-json\/wp\/v2\/product_cat?post=435795"},{"taxonomy":"product_tag","embeddable":true,"href":"https:\/\/pdfstandards.shop\/wp-json\/wp\/v2\/product_tag?post=435795"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}